Test report_DSC

FCC ID: 2AAZPFAN55T

Test Report

Download: PDF
FCCID_2887117

                                                                               Report No.: ATE20160089
                                                                                            Page 1 of 28




                             APPLICATION CERTIFICATION
                                         On Behalf of
                      Carewell Electric Technology (Zhongshan) Co., Ltd.

                                     REMOTE CONTROL
                                     Model No.: FAN-55T

                                    FCC ID: 2AAZPFAN55T




            Prepared for        :   Carewell Electric Technology (Zhongshan) Co., Ltd.
            Address             :   Torch Development Zone, No.2, Ouya Road, Zhongshan,
                                    Guangdong, China

            Prepared by         :   ACCURATE TECHNOLOGY CO., LTD
            Address             :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                    Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                    P.R. China

                                    Tel: (0755) 26503290
                                    Fax: (0755) 26503396




            Report Number       :   ATE20160089
            Date of Test        :   Jan 15, 2016-Jan 22, 2016
            Date of Report      :   Jan 22, 2016




FCC ID: 2AAZPFAN55T                                                        ACCURATE TECHNOLOGY CO., LTD


                                                                                                                                Report No.: ATE20160089
                                                                                                                                             Page 2 of 28



                                                         TABLE OF CONTENTS

     Description
     Page


     Test Report Certification
    1.      GENERAL INFORMATION .......................................................................................................... 4
         1.1.     Description of Device (EUT) .................................................................................................................... 4
         1.2.     Description of Test Facility ...................................................................................................................... 5
         1.3.     Measurement Uncertainty ......................................................................................................................... 5
    2.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 6
    3.      SUMMARY OF TEST RESULTS................................................................................................... 7
    4.      THE FIELD STRENGTH OF RADIATION EMISSION ............................................................ 8
         4.1.     Block Diagram of Test Setup.................................................................................................................... 8
         4.2.     The Field Strength of Radiation Emission Measurement Limits .............................................................. 9
         4.3.     Configuration of EUT on Measurement ................................................................................................... 9
         4.4.     Operating Condition of EUT .................................................................................................................... 9
         4.5.     Test Procedure ........................................................................................................................................ 10
         4.6.     The Field Strength of Radiation Emission Measurement Results .......................................................... 11
    5.      20DB OCCUPIED BANDWIDTH ................................................................................................ 13
         5.1.     Block Diagram of Test Setup.................................................................................................................. 13
         5.2.     The Bandwidth of Emission Limit According To FCC Part 15 Section 15.231(c) ................................ 13
         5.3.     EUT Configuration on Measurement ..................................................................................................... 14
         5.4.     Operating Condition of EUT .................................................................................................................. 14
         5.5.     Test Procedure ........................................................................................................................................ 14
         5.6.     Measurement Result ............................................................................................................................... 14
    6.      RELEASE TIME MEASUREMENT............................................................................................ 15
         6.1.     Block Diagram of Test Setup.................................................................................................................. 15
         6.2.     Release Time Measurement According To FCC Part 15 Section 15.231(a) .......................................... 15
         6.3.     EUT Configuration on Measurement ..................................................................................................... 16
         6.4.     Operating Condition of EUT .................................................................................................................. 16
         6.5.     Test Procedure ........................................................................................................................................ 16
         6.6.     Measurement Result ............................................................................................................................... 16
    7.      AVERAGE FACTOR MEASUREMENT .................................................................................... 17
         7.1.     Block Diagram of Test Setup.................................................................................................................. 17
         7.2.     Average factor Measurement according to ANSI C63.10-2013 ............................................................. 17
         7.3.     EUT Configuration on Measurement ..................................................................................................... 18
         7.4.     Operating Condition of EUT .................................................................................................................. 18
         7.5.     Test Procedure ........................................................................................................................................ 18
         7.6.     Measurement Result ............................................................................................................................... 18
    8.      ANTENNA REQUIREMENT........................................................................................................ 19
         8.1.     The Requirement .................................................................................................................................... 19
         8.2.     Antenna Construction ............................................................................................................................. 19




FCC ID: 2AAZPFAN55T                                                                                                      ACCURATE TECHNOLOGY CO., LTD


                                                                                  Report No.: ATE20160089
                                                                                               Page 3 of 28




                                     Test Report Certification

             Applicant          :   Carewell Electric Technology (Zhongshan) Co., Ltd.
             Manufacturer       :   Carewell Electric Technology (Zhongshan) Co., Ltd.
             EUT Description    :   REMOTE CONTROL
                                     (A) MODEL NO.: FAN-55T
                                     (B) SERIAL NO.: N/A
                                     (C) POWER SUPPLY: DC 12V (Battery)

             Measurement Procedure Used:

             FCC Rules and Regulations Part 15 Subpart C Section 15.231a
             ANSI C63.10-2013

             The device described above is tested by ACCURATE TECHNOLOGY CO., LTD to
             determine the maximum emission levels emanating from the device. The maximum emission
             levels are compared to the FCC Part 15 Subpart C Section 15.231a. The measurement results
             are contained in this test report and ACCURATE TECHNOLOGY CO., LTD is assumed full
             responsibility for the accuracy and completeness of these measurements. Also, this report
             shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC
             requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of ACCURATE TECHNOLOGY CO., LTD.


             Date of Test :                            Jan 15, 2016-Jan 22, 2016
             Date of Report :                                Jan 22, 2016


             Prepared by :
                                                          (Tim.zhang, Engineer)




             Approved & Authorized Signer :
                                                          ( Sean Liu, Manager)




FCC ID: 2AAZPFAN55T                                                          ACCURATE TECHNOLOGY CO., LTD


                                                                            Report No.: ATE20160089
                                                                                         Page 4 of 28




         1. GENERAL INFORMATION


                1.1.Description of Device (EUT)
                      EUT               : REMOTE CONTROL

                      Model Number      : FAN-55T

                      Power Supply      : DC 12V (powered by battery)

                      Modulation:       : ASK

                      Operation Frequency : 315MHz

                      Applicant         : Carewell Electric Technology (Zhongshan) Co., Ltd.
                      Address           : Torch Development Zone, No.2, Ouya Road, Zhongshan,
                                          Guangdong, China

                      Manufacturer      : Carewell Electric Technology (Zhongshan) Co., Ltd.
                      Address           : Torch Development Zone, No.2, Ouya Road, Zhongshan,
                                          Guangdong, China

                      Date of sample    : Jan 15, 2016
                      received
                      Date of Test      : Jan 15, 2016-Jan 22, 2016




FCC ID: 2AAZPFAN55T                                                     ACCURATE TECHNOLOGY CO., LTD


                                                                                     Report No.: ATE20160089
                                                                                                  Page 5 of 28




                1.2.Description of Test Facility
                      EMC Lab                :   Accredited by TUV Rheinland Shenzhen

                                                 Listed by FCC
                                                 The Registration Number is 752051

                                                 Listed by Industry Canada
                                                 The Registration Number is 5077A-2

                                                 Accredited by China National Accreditation Committee
                                                 for Laboratories
                                                 The Certificate Registration Number is L3193

                      Name of Firm           :   ACCURATE TECHNOLOGY CO., LTD
                      Site Location          :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                                 Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                                 P.R. China


                1.3.Measurement Uncertainty
                      Conducted Emission Expanded Uncertainty    =   2.23dB, k=2

                      Radiated emission expanded uncertainty     =   3.08dB, k=2
                      (9kHz-30MHz)

                      Radiated emission expanded uncertainty     =   4.42dB, k=2
                      (30MHz-1000MHz)

                      Radiated emission expanded uncertainty     =   4.06dB, k=2
                      (Above 1GHz)




FCC ID: 2AAZPFAN55T                                                           ACCURATE TECHNOLOGY CO., LTD


                                                                          Report No.: ATE20160089
                                                                                       Page 6 of 28




         2. MEASURING DEVICE AND TEST EQUIPMENT
               Table 1: List of Test and Measurement Equipment
 Kind of equipment Manufacturer         Type          S/N          Calibrated dates Cal. Interval
 EMI Test Receiver Rohde&Schwarz        ESCS30        100307       Jan. 09, 2016      One Year
 EMI Test Receiver Rohde&Schwarz        ESPI3         101526/003   Jan. 09, 2016      One Year
 Spectrum Analyzer Agilent              E7405A        MY45115511   Jan. 09, 2016      One Year
 Pre-Amplifier        Rohde&Schwarz     CBLU118354 3791            Jan. 09, 2016      One Year
                                        0-01
 Loop Antenna         Schwarzbeck       FMZB1516   1516131         Jan. 14, 2016      One Year
 Bilog Antenna        Schwarzbeck       VULB9163      9163-323     Jan. 14, 2016      One Year
 Horn Antenna         Schwarzbeck       BBHA9120D     9120D-655    Jan. 14, 2016      One Year
 Horn Antenna         Schwarzbeck       BBHA9120D     9120D-1067   Jan. 14, 2016      One Year
 LISN                 Rohde&Schwarz     ESH3-Z5       100305       Jan. 09, 2016      One Year
 LISN                 Schwarzbeck       NSLK8126      8126431      Jan. 09, 2016      One Year
 Highpass Filter    Wainwright          WHKX3.6/18 N/A             Jan. 09, 2016      One Year
                    Instruments         G-10SS
 Band Reject Filter Wainwright          WRCG2400/2 N/A             Jan. 09, 2016      One Year
                    Instruments         485-2375/2510
                                        -60/11SS




FCC ID: 2AAZPFAN55T                                                  ACCURATE TECHNOLOGY CO., LTD


                                                                                    Report No.: ATE20160089
                                                                                                 Page 7 of 28




         3. SUMMARY OF TEST RESULTS

               FCC Rules                Description of Test       Result
               Section 15.207           Conducted Emission        N/A
               Section 15.231(b)        Radiated Emission         Compliant
               Section 15.231(c)        20dB Bandwidth            Compliant
               Section 15.231(a)(1)     Release Time        Compliant
                                        Measurement
               Section 15.203           Antenna Requirement Compliant
              The product is a manually operated transmitter.
              Section 15.231 (a) (2), (3), (4) and (5) are not applicable.

              All normal using modes of the normal function were tested but only the worst test data of the
              worst mode is recorded by this report.




FCC ID: 2AAZPFAN55T                                                            ACCURATE TECHNOLOGY CO., LTD


                                                                                   Report No.: ATE20160089
                                                                                                Page 8 of 28




         4. THE FIELD STRENGTH OF RADIATION EMISSION


                4.1.Block Diagram of Test Setup
                          4.1.1.Block diagram of connection between the EUT and simulators

                                                EUT

                                     (EUT: REMOTE CONTROL)

                          4.1.2.Semi-Anechoic Chamber Test Setup Diagram

                                   ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

                                                   3 METERS




                                                                           EUT

                      Cable
                                                                                     0.8 METER



                                    GROUND PLANE

                                     (EUT: REMOTE CONTROL)




FCC ID: 2AAZPFAN55T                                                            ACCURATE TECHNOLOGY CO., LTD


                                                                                     Report No.: ATE20160089
                                                                                                  Page 9 of 28




                4.2.The Field Strength of Radiation Emission Measurement Limits
                        4.2.1. Radiation Emission Measurement Limits According to FCC Part 15 Section
                               15.231(b)

                             Frequency Range of            Field Strength of          Field Strength of
                                                         Fundamental Emission        Spurious Emission
                                Fundamental                   [Average]                  [Average]
                                   [MHz]                        [μV/m]                     [μV/m]
                                40.66-40.70                      2250                       225
                                   70-130                        1250                       125
                                  130-174                     1250-3750                   125-375
                                  174-260                        3750                       375
                                  260-470                    3750-12500                  375-1250
                                Above 470                       12500                      1250
                        Where F is the frequency in MHz, the formulas for calculating the maximum
                        permitted fundamental field strengths are as follows: for the band 130-174 MHz,
                        uV/m at 3 meters = 56.81818(F) - 6136.3636; for the band 260-470 MHz, uV/m at
                        3 meters = 41.6667(F) - 7083.3333. The maximum permitted unwanted emission
                        level is 20 dB below the maximum permitted fundamental level.
                        4.2.2. Restricted Band Radiation Emission Measurement Limits According to FCC
                               part 15 Section 15.205 and Section15.209.


                4.3.Configuration of EUT on Measurement
                      The following equipment is installed on Radiated Emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to
                      maximize its emission characteristics in normal application.
                        4.3.1. REMOTE CONTROL (EUT)
                             Model Number         :   FAN-55T
                             Serial Number        :   N/A
                             Manufacturer         :   Carewell Electric Technology (Zhongshan) Co., Ltd.



                4.4.Operating Condition of EUT
                        4.4.1.Setup the EUT and simulator as shown as Section 4.1.

                        4.4.2.Turn on the power of all equipment.

                        4.4.3. Let the EUT work in TX mode measure it.




FCC ID: 2AAZPFAN55T                                                              ACCURATE TECHNOLOGY CO., LTD


                                                                                   Report No.: ATE20160089
                                                                                              Page 10 of 28




                4.5.Test Procedure
                      The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                      ground(Below 1GHz). The EUT and its simulators are placed on a turntable, which is
                      1.5 meter high above ground(Above 1GHz). The turntable can rotate 360 degrees to
                      determine the position of the maximum emission level. EUT is set 3.0 meters away
                      from the receiving antenna, which is mounted on an antenna tower. The antenna can be
                      moved up and down between 1.0 meter and 4 meters to find out the maximum
                      emission level. Broadband antenna (calibrated bi-log antenna) is used as receiving
                      antenna. Both horizontal and vertical polarizations of the antenna are set on
                      measurement. In order to find the maximum emission levels, all of the EUT location
                      must be manipulated according to ANSI C63.10:2013 on radiated emission
                      measurement. The EUT was tested in 3 orthogonal planes.

                      The bandwidth of test receiver is set at 120 kHz in 30-1000 MHz, and 1 MHz in
                      1000-4000 MHz.

                      The frequency range from 30 MHz to 4000 MHz is checked.




FCC ID: 2AAZPFAN55T                                                            ACCURATE TECHNOLOGY CO., LTD


                                                                                      Report No.: ATE20160089
                                                                                                 Page 11 of 28




                4.6.The Field Strength of Radiation Emission Measurement Results
                       PASS.

                       The frequency range 30MHz to 4000MHz is investigated.

EUT:                  REMOTE CONTROL
Model No.:            FAN-55T                           Power Supply:       DC 12V
Test Mode:            TX                                Test Engineer:      Star

Frequency     Reading       Factor    Average   Result(dBμV/m)   Limit(dBμV/m)      Margin(dB)       Polarization
 (MHz)       (dBμV/m)        Corr.    Factor
                PEAK           (dB)    (dB)      AV     PEAK      AV     PEAK       AV      PEAK
   315         90.48        -11.24    -13.23    66.01    79.24   75.62   95.62     -9.61    -16.38
   630         62.98        -6.36     -13.23    43.39    56.62   55.62   75.62    -12.23    -19.00
   945         45.02        -2.78     -13.23    29.01    42.24   55.62   75.62    -26.61    -33.38   Horizontal
  1260         64.98        -12.28    -13.23    39.47    52.70   55.62   75.62    -16.18    -22.92
  1890         61.81        -9.68     -13.23    38.90    52.13   55.62   75.62    -16.72    -23.49
   315         91.96        -11.24    -13.23    67.49    80.72   75.62   95.62     -8.13    -14.90
   630         61.00        -6.36     -13.23    41.41    54.64   55.62   75.62    -14.21    -20.98
   945         47.50        -2.78     -13.23    31.49    44.72   55.62   75.62    -24.13    -30.90    Vertical
  1260         64.39        -12.28    -13.23    38.88    52.11   55.62   75.62    -16.74    -23.51
  1890         60.42        -9.68     -13.23    37.51    50.74   55.62   75.62    -18.11    -24.88
Note:
1. Emissions attenuated more than 20 dB below the permissible value are not reported.
2. The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss,
   and subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is
   as follows:
  Result = Reading + Corrected Factor
  Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain
3. FCC Limit for Average Measurement = 41.6667(315)-7083.3333 = 6041.6772 μV/m =75.62 μV/m
4. The spectral diagrams in appendix I display the measurement of peak values.
5. Average value= PK value + Average Factor (duty factor)
6. If the peak-detected amplitude can be shown to comply with the average limit, then it is not necessary to
perform a separate average measurement.
7. The EUT is tested radiation emission in three axes(X,Y,Z). The worst emissions are reported in three
axes.


FCC ID: 2AAZPFAN55T                                                               ACCURATE TECHNOLOGY CO., LTD


                                                 Report No.: ATE20160089
                                                            Page 12 of 28

8. Pulse Desensitization Correction Factor
  Pulse Width (PW) = 0.46377ms
  2/PW = 2/0.42ms = 4.76kHz
  RBW (100 kHz) > 2/PW (4.76 kHz)
  Therefore PDCF is not needed




FCC ID: 2AAZPFAN55T                          ACCURATE TECHNOLOGY CO., LTD


                                                                                   Report No.: ATE20160089
                                                                                              Page 13 of 28




         5. 20DB OCCUPIED BANDWIDTH


                5.1.Block Diagram of Test Setup
                          5.1.1.Block diagram of connection between the EUT and simulators

                                                EUT

                                     (EUT: REMOTE CONTROL)

                          5.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                   3 METERS




                                                                           EUT

                      Cable
                                                                                     0.8 METER



                                    GROUND PLANE

                                    (EUT: REMOTE CONTROL)


                5.2.The Bandwidth of Emission Limit According To FCC Part 15 Section

                       15.231(c)
                       The bandwidth of emission shall be no wider than 0.25% of the center frequency.
                       Therefore, the bandwidth of the emission limit is 315 MHz×0.25% = 787.5 kHz.
                       Bandwidth is determined at the two points 20 dB down from the top of modulated
                       carrier.




FCC ID: 2AAZPFAN55T                                                            ACCURATE TECHNOLOGY CO., LTD


                                                                                      Report No.: ATE20160089
                                                                                                 Page 14 of 28




                5.3.EUT Configuration on Measurement
                      The following equipment are installed on the bandwidth of emission Measurement to
                      meet the commission requirements and operating regulations in a manner which tends
                      to maximize its emission characteristics in normal application.
                         5.3.1.REMOTE CONTROL (EUT)
                              Model Number      :   FAN-55T
                              Serial Number     :   N/A
                              Manufacturer      :   Carewell Electric Technology (Zhongshan) Co., Ltd.




                5.4.Operating Condition of EUT
                         5.4.1.Setup the EUT and simulator as shown as Section 5.1.

                         5.4.2.Turn on the power of all equipment.

                         5.4.3.Let the EUT work in TX mode measure it.


                5.5.Test Procedure
                         5.5.1. Set SPA Center Frequency = Fundamental frequency, RBW = 10 kHz, VBW
                                = 30 kHz, Span = 1MHz.

                         5.5.2.Set SPA Max hold, Mark peak, -20 dB.


                5.6.Measurement Result

                      The EUT does meet the FCC requirement.

                      -20 dB bandwidth =50 kHz <787.5 kHz.

                      The spectral diagrams in appendix I.




FCC ID: 2AAZPFAN55T                                                              ACCURATE TECHNOLOGY CO., LTD


                                                                                     Report No.: ATE20160089
                                                                                                Page 15 of 28




         6. RELEASE TIME MEASUREMENT


                6.1.Block Diagram of Test Setup
                          6.1.1.Block diagram of connection between the EUT and simulators

                                                 EUT

                                     (EUT: REMOTE CONTROL)

                          6.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                    3 METERS




                                                                            EUT

                      Cable
                                                                                       0.8 METER



                                    GROUND PLANE

                                     (EUT: REMOTE CONTROL)


                6.2.Release Time Measurement According To FCC Part 15 Section 15.231(a)
                       Section 15.231(a) (1) A manually operated transmitter shall employ a switch that will
                       automatically deactivate the transmitter within not more than 5 seconds of being
                       released.




FCC ID: 2AAZPFAN55T                                                             ACCURATE TECHNOLOGY CO., LTD


                                                                                      Report No.: ATE20160089
                                                                                                 Page 16 of 28




                6.3.EUT Configuration on Measurement
                      The following equipment are installed on Release Time Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to
                      maximize its emission characteristics in normal application.
                         6.3.1. REMOTE CONTROL (EUT)
                              Model Number      :   FAN-55T
                              Serial Number     :   N/A
                              Manufacturer      :   Carewell Electric Technology (Zhongshan) Co., Ltd.




                6.4.Operating Condition of EUT
                         6.4.1.Setup the EUT and simulator as shown as Section 6.1.

                         6.4.2.Turn on the power of all equipment.

                         6.4.3.Let the EUT work in TX mode measure it.


                6.5.Test Procedure
                         6.5.1. Set SPA Center Frequency = Fundamental frequency, RBW = 100 kHz, VBW
                                = 300 kHz, Span = 0 Hz. Sweep time = 10 s.

                         6.5.2.Set EUT as normal operation and press Transmitter button.

                         6.5.3.Set SPA View. Delta Mark time.


                6.6. Measurement Result

                      The release time less than 5 seconds.


                      Release Time = 2.79s

                      The spectral diagrams in appendix I.




FCC ID: 2AAZPFAN55T                                                              ACCURATE TECHNOLOGY CO., LTD


                                                                                     Report No.: ATE20160089
                                                                                                Page 17 of 28




         7. AVERAGE FACTOR MEASUREMENT


                7.1.Block Diagram of Test Setup
                          7.1.1.Block diagram of connection between the EUT and simulators

                                               EUT

                                   (EUT: REMOTE CONTROL)

                          7.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                    3 METERS




                                                                             EUT

                      Cable
                                                                                       0.8 METER


                                     GROUND PLANE


                7.2.Average factor Measurement according to ANSI C63.10-2013
                  ANSI C63.10-2013 Section 7.5 Unless otherwise specified, when the radiated emission
                  limits are expressed in terms of the average value of the emission, and pulsed operation is
                  employed, the measurement field strength shall be determined by averaging over one
                  complete pulse train, including blanking intervals, as long as the pulse train does not
                  exceed 0.1 s (100 ms). In cases where the pulse train exceeds 0.1 s, the measured field
                  strength shall be determined during a 0.1 s interval.64 The following procedure is an
                  example of how the average value may be determined. The average field strength may be
                  found by measuring the peak pulse amplitude (in log equivalent units) and determining
                  the duty cycle correction factor (in dB) associated with the pulse modulation as shown in
                  Equation (10):
                  Average factor in dB = 20 log (duty cycle)

FCC ID: 2AAZPFAN55T                                                              ACCURATE TECHNOLOGY CO., LTD


                                                                                      Report No.: ATE20160089
                                                                                                 Page 18 of 28




                7.3.EUT Configuration on Measurement
                      The following equipment are installed on average factor Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to
                      maximize its emission characteristics in normal application.
                         7.3.1. REMOTE CONTROL
                              Model Number      :   FAN-55T
                              Serial Number     :   N/A
                              Manufacturer      :   Carewell Electric Technology (Zhongshan) Co., Ltd.


                7.4.Operating Condition of EUT
                         7.4.1.Setup the EUT and simulator as shown as Section 7.1.

                         7.4.2.Turn on the power of all equipment.

                         7.4.3.Let the EUT work in TX mode measure it.


                7.5.Test Procedure
                         7.5.1.The time period over which the duty cycle is measured is 100 milliseconds, or
                               the repetition cycle, whichever is a shorter time frame. The worst case
                               (highest percentage on) duty cycle is used for the calculation.

                         7.5.2.Set SPA Center Frequency = Fundamental frequency, RBW = 100 kHz, VBW
                               = 300 kHz, Span = 0 Hz.

                         7.5.3.Set EUT as normal operation.

                         7.5.4.Set SPA View. Delta Mark time.


                7.6. Measurement Result
                      The duty cycle is simply the on time divided by the period:

                      The duration of one cycle = 24.6ms

                      Effective period of the cycle = (0.74×1) + (0.42×11)ms =5.36 ms

                      DC =5.36ms/24.6ms=0.218

                      Therefore, the average factor is found by 20log0.218= -13.23dB

                      The spectral diagrams in appendix I.

FCC ID: 2AAZPFAN55T                                                              ACCURATE TECHNOLOGY CO., LTD


                                                                                       Report No.: ATE20160089
                                                                                                  Page 19 of 28




          8. ANTENNA REQUIREMENT


                8.1.The Requirement
                      According to Section 15.203, an intentional radiator shall be designed to ensure that no
                      antenna other than that furnished by the responsible party shall be used with the device.


                8.2.Antenna Construction
                      Device is equipped with permanent attached antenna, which isn’t displaced by other
                      antenna. The Antenna gain of EUT is 0dBi. Therefore, the equipment complies with the
                      antenna requirement of Section 15.203.




                                       Antenna




FCC ID: 2AAZPFAN55T                                                                ACCURATE TECHNOLOGY CO., LTD


                                          Report No.: ATE20160089
                                                     Page 20 of 28




                      APPENDIX I
                      (Test Curves)




FCC ID: 2AAZPFAN55T                   ACCURATE TECHNOLOGY CO., LTD


Qu.w

                              0               ACCURATE TECHNOLOGY CO., LTD.                                                       Site: 2# Chamber

 AT c                                         F1,Bldg.A,Changyuan New Material Port Keyuan Rd,                          Tel:+86—0755—26503290
                                              Science & Industry Park,Nanshan Shenzhen,P.R.China                        Fax:+86—0755—26503396
Job No.:         star2015 #1014                                                         Polarization:          Horizontal
Standard: FCC Class B 3M Radiated                                                       Power Source:              DC 12V
Test item:             Radiation Test                                                   Date: 16/01/16/
Temp.( C)Hum.(%) 23 C/48 %                                                              Time: 9/13/28
EUT:                  REMOTE CONRTOL                                                    Engineer Signature:
Mode:            TX                                                                     Distance:       3m
Model:           FAN—55T
Manufacturer: Carewell
Note:          Report NO.:ATE20160089



       100.0         dBu¥/m
                                                                                                                        fimit1:

       90


       80


       70


       60


       50


       40


       30


       20


       10

       0.0                        :      ;      ‘     ;      ‘                                 }          ;         t       ;      j   ;
            30.000       40       50     60     *U   .Sl:l   ‘                         300     4‘00      f‘ll]l]   éUU      iflU    ‘ 1UbU.U MHz


                 Freq.                Reading        Factor      Result   Limit   |Margin             Height       Degree
 No:            (MHz)    (dBuvim)                     (dB) (dBuV/im) (dBuvim)| (dBy P49| (em)                      (gea)           Reme
1               315.0806) 9048                       1124    7924      95.62 16.38| peak
3               630 i612) 6298                       —636    5662      7562 |19.00| peak
3               g4s2418] 4502                        278     4224      7562 3338) peak


@i—‘                                  ACCURATE TECHNOLOGY CO., LTD.                                                             Site: 2# Chamber
                                        F1,Bldg.A, Changyuan New Material Port Keyuan Rd,                             Tel:+86—0755—26503290
                                        Science & Industry Park, Nanshan Shenzhen,P.R.China                           Fax:+86—0755—26503396
Job No.:       star2015 #1015                                                           Polarization:         Vertical
Standard: FCC Class B 3M Radiated                                                       Power Source:          DC 12V
Test item:         Radiation Test                                                       Date: 16/01/167
Temp.(        C)Hum.(%) 23          C/48 %                                          Time: 9/17/21
EUT:               REMOTE CONRTOL                                                       Engineer Signature:
Mode:          TX                                                                       Distance:       3m
Model:         FAN—55T
Manufacturer: Carewell
Note:        Report NO.:ATE20160089



     100.0     dBu¥/m
                                                                                                                      limit1:         —

     90


     80


     70


     60


     50
     40


     30


     20


     10


     0.0                   [             10            |                                       [        |        1J        P     1     i
          30.000     40    50     0      70   80                                   300         400      500     600       700        1000.0 MHz


               Freq.           Reading        Factor        Result    Limit   |Margin                Height     Degree
NO            (MHz)        (dBuv/im)           (d8)        (dBuVim) (dBuVvim)| (ag) PS°" (em)                   (dea.)           ROm#K
1              315.0806         91.96         —11.24        80.72    95.62     14.90|      peak
2              630.1612         61.00         —6.36         54.64    75.62    20.98|       peak
3              945.2418)        47.50         —2.78         44.72    75.62     30.90|      peak


(um


                          8            ACCURATE TECHNOLOGY CO., LTD.                                                            Site: 2# Chember
    A              c                     F1,Bldg,A,Changyuan New Material Port Keyuan Rd,                             Tef:r88.0705—20003000
                                         Science & Industry Park,Nanshan Shenzhen,P.R.China                            Fax:+86—0755—26503396
Job No.:         star2015 #1013                                                              Polarization:        Horizontal
Standard: FCC Class B 3M Radiated                                                            Power Source:         DC 12V
Test item:         Radiation Test                                                            Date: 16/01/16/
Temp.(         C)Hum.(%) 23            C/48 %                                                Time: 9/09/37
EUT:              REMOTE CONRTOL                                                             Engineer Signature:
Mode:            TX                                                                          Distance:       3m
Model:           FAN—55T
Manufacturer: Carewell
Note:          Report NO.:ATE20160089



      90.0       dBu¥/m
                                                                                                                      limit1:       —

      80


      70


      UH.     |[eommrevcarmrrrarererenronevevranreeperrectenraceys z       Pferermmcepmmmmemzcens reopmeaireemenne              appaven


      50



      40



      30



      20



      10


      0.0
            1000.000                                                   —                                   3000                   4000.0 MHz


                 Freq.         Reading         Factor         Result         Limit    [Margin            Height    Degree
No:             (MHz)     (dBuvim)              (d8) (dBuV¥im) (dBuvim)| (aB) |P4°" (em)                            (dea)        R®ma*
                 1260.322] 6498                1228    5270      7502 22.92| peak
3                1890.365] 61.81               —d68    5213      7562 23.49) peak
3               2520.645| 5809                 722     5087      7562 24.75| peak


(u.w


                        ®         ACCURATE TECHNOLOGY CO., LTD.                                          Site: 2# Chamber
 AT c                              F1,Bidg.A,Changyuan New Material Port Keyuan Rd,                  Tel:+86—0755—26503290
                                   Science & Industry Park,Nanshan Shenzhen,P.R.China                Fax:+86—0755—26503396
Job No.:       star2015 #1012                                              Polarization:        Vertical
Standard: FCC Class B 3M Radiated                                          Power Source:         DC 12V
Test item:       Radiation Test                                            Date: 16/01/16/
Temp.(       C)Hum.(%) 23         C/48 %                                   Time: 9/05/04
EUT:            REMOTE CONRTOL                                             Engineer Signature:
Mode:          TX                                                          Distance:       3m
Model:         FAN—55T
Manufacturer: Carewell
Note:        Report NO.:ATE20160089



     90.0      dBuV/m
                                                                                                    limit1:      —

     80


     70


     60


     50


     40



     30



     20



     10



     0.0
          1000.000                                                                       3000                  4000.0 MHz


               Freq.        Reading    Factor    Result      Limit   |Margin           Height    Degree
No            (MHz)     (dBuvim)         (dB) (dBuV/im) (dBuvim)| (dB) P49 (em)                   (ea)        Rema"k
               1260322 6430            41228    5211      7562 2351| peak
               i8Go365s] 6042           —9.68   5074      7562 24.88| peak
              2205.564| 5674            —818    4856      7562 27.06) peak


                                                                                                        Report No.: ATE20160089
                                                                                                                   Page 25 of 28




                                                                      * RBW 10 kHz   Marker 1 [T1 ]
                                                                      * VBW 30 kHz               5.35 dBm
                          Ref   15 dBm           Att     50 dB         SWT 10 ms        315.012000000 MHz

                                                                                     ndB [T1]   20.00   dB
                          10                                                         BW 50.000000000    kHz
                                                                  1
                                                                                     Temp 1 [T1 ndB]          A

                                                                                               -14.41   dBm
                  1 PK    0
                                                                                        314.988000000   MHz
                  MAXH
                                                                                     Temp 2 [T1 ndB]
                          -10                                                                  -15.01   dBm
                                                                 T1    T2               315.038000000   MHz

                          -20



                          -30



                          -40



                          -50



                          -60



                          -70



                          -80


                          Center 315 MHz                     100 kHz/                          Span 1 MHz



                  Date:         16.JAN.2016   10:06:45




FCC ID: 2AAZPFAN55T                                                                             ACCURATE TECHNOLOGY CO., LTD


                                                                                                   Report No.: ATE20160089
                                                                                                              Page 26 of 28




                                                                    RBW 100 kHz    Delta 2 [T1 ]
                                                                   * VBW 300 kHz               1.07 dB
                          Ref   15 dBm           Att     50 dB      SWT 10 s               2.790000 s

                                                                                   Marker 1 [T1 ]
                          10                                                                 -46.15 dBm
                                                                                           3.420000 s     A
                                                                                                          SGL
                  1 PK    0
                  MAXH

                          -10



                          -20



                          -30



                          -40
                                                   1                      2


                          -50



                          -60



                          -70



                          -80


                          Center 315 MHz                         1 s/



                  Date:         22.JAN.2016   10:53:14



Release Time = 2.79s




FCC ID: 2AAZPFAN55T                                                                           ACCURATE TECHNOLOGY CO., LTD


                                                                                                     Report No.: ATE20160089
                                                                                                                Page 27 of 28




The graph shows the pattern of coding during the signal transmission.
The duration of one cycle = 24.6 ms.

                                                    RBW 100 kHz    Marker 1 [T1 ]
                                                   * VBW 300 kHz             -38.60 dBm
        Ref   30 dBm            Att     60 dB       SWT 100 ms            20.800000 ms
        30                                                         Delta 2 [T1 ]
                                                                               0.07   dB
                                                                          13.400000   ms   A
        20
                                                                   Delta 3 [T1 ]           SGL
1 PK
                                                                              -2.35   dB
MAXH
        10                                                                24.600000   ms


        0



        -10



        -20



        -30

                         1        2
                                            3
        -40



        -50



        -60


        -70

        Center 315 MHz                          10 ms/



Date:         16.JAN.2016    10:15:10




FCC ID: 2AAZPFAN55T                                                                              ACCURATE TECHNOLOGY CO., LTD


                                                                                                      Report No.: ATE20160089
                                                                                                                 Page 28 of 28


        DELTA MARKER 2                                RBW 100 kHz    Delta 2 [T1 ]
          740 µs                                     * VBW 300 kHz               0.74 dB
        Ref 15 dBm                 Att     50 dB      SWT 10 ms            740.000000 µs

                                                                     Marker 1 [T1 ]
        10                                                                     -53.03 dBm
                                                                             1.760000 ms    A
                                                                                            SGL
1 PK    0
MAXH

        -10



        -20



        -30



        -40



        -50          1      2



        -60



        -70



        -80


        Center 315 MHz                             1 ms/



Date:         16.JAN.2016       10:16:16



The graph shows the duration of ‘on’ signal. From marker 1 to marker 2, duration is 0.74ms.
        MARKER 1                                      RBW 100 kHz    Marker 1 [T1 ]
          3.1 ms                                     * VBW 300 kHz             -52.36 dBm
        Ref 15 dBm                 Att     50 dB      SWT 10 ms              3.100000 ms

                                                                     Delta 2 [T1 ]
        10                                                                      -0.78 dB
                                                                           420.000000 µs    A
                                                                                            SGL
1 PK    0
MAXH

        -10



        -20



        -30



        -40



        -50                        1   2


        -60



        -70



        -80


        Center 315 MHz                             1 ms/



Date:         16.JAN.2016       10:16:35



The graph shows the duration of ‘on’ signal. From marker 1 to marker 2, duration is 0.42ms.



FCC ID: 2AAZPFAN55T                                                                               ACCURATE TECHNOLOGY CO., LTD



Document Created: 2016-01-27 10:26:26
Document Modified: 2016-01-27 10:26:26

© 2024 FCC.report