RF test report

FCC ID: 2AAZPFAN53T

Test Report

Download: PDF
FCCID_2121828

                                                                                                   Page 1 of 29




                             APPLICATION CERTIFICATION
                                         On Behalf of
                      Carewell Electric Technology (Zhongshan) Co., Ltd.

                                     REMOTE CONTROL
                                     Model No.:FAN-53T

                                    FCC ID: 2AAZPFAN53T




            Prepared for        :   Carewell Electric Technology (Zhongshan) Co., Ltd.
            Address             :   Torch Development Zone, No.2, Ouya Road, Zhongshan,
                                    Guangdong,China

            Prepared by         :   ACCURATE TECHNOLOGY CO., LTD
            Address             :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                    Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                    P.R. China

                                    Tel: (0755) 26503290
                                    Fax: (0755) 26503396




            Report Number       :   ATE20132396
            Date of Test        :   Nov 08-15, 2013
            Date of Report      :   Nov 15, 2013




FCC ID: 2AAZPFAN53T                                        ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                                                                    Page 2 of 29




                                                         TABLE OF CONTENTS

     Description
     Page


     Test Report Certification
    1.      GENERAL INFORMATION .......................................................................................................... 4
         1.1.     Description of Device (EUT)....................................................................................................................4
         1.2.     Description of Test Facility ......................................................................................................................5
         1.3.     Measurement Uncertainty.........................................................................................................................5
    2.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 6
    3.      SUMMARY OF TEST RESULTS................................................................................................... 7
    4.      THE FIELD STRENGTH OF RADIATION EMISSION ............................................................ 8
         4.1.     Block Diagram of Test Setup....................................................................................................................8
         4.2.     The Field Strength of Radiation Emission Measurement Limits..............................................................9
         4.3.     Configuration of EUT on Measurement ...................................................................................................9
         4.4.     Operating Condition of EUT ....................................................................................................................9
         4.5.     Test Procedure ........................................................................................................................................10
         4.6.     The Field Strength of Radiation Emission Measurement Results ..........................................................11
    5.      20DB OCCUPIED BANDWIDTH ................................................................................................ 13
         5.1.     Block Diagram of Test Setup..................................................................................................................13
         5.2.     The Bandwidth of Emission Limit According To FCC Part 15 Section 15.231(c) ................................13
         5.3.     EUT Configuration on Measurement .....................................................................................................14
         5.4.     Operating Condition of EUT ..................................................................................................................14
         5.5.     Test Procedure ........................................................................................................................................14
         5.6.     Measurement Result ...............................................................................................................................14
    6.      RELEASE TIME MEASUREMENT............................................................................................ 15
         6.1.     Block Diagram of Test Setup..................................................................................................................15
         6.2.     Release Time Measurement According To FCC Part 15 Section 15.231(a) ..........................................15
         6.3.     EUT Configuration on Measurement .....................................................................................................16
         6.4.     Operating Condition of EUT ..................................................................................................................16
         6.5.     Test Procedure ........................................................................................................................................16
         6.6.     Measurement Result ...............................................................................................................................16
    7.      AVERAGE FACTOR MEASUREMENT .................................................................................... 17
         7.1.     Block Diagram of Test Setup..................................................................................................................17
         7.2.     Average factor Measurement according to ANSI C63.4-2009...............................................................17
         7.3.     EUT Configuration on Measurement .....................................................................................................18
         7.4.     Operating Condition of EUT ..................................................................................................................18
         7.5.     Test Procedure ........................................................................................................................................18
         7.6.     Measurement Result ...............................................................................................................................18
    8.      ANTENNA REQUIREMENT........................................................................................................ 19
         8.1.     The Requirement ....................................................................................................................................19
         8.2.     Antenna Construction .............................................................................................................................19




FCC ID: 2AAZPFAN53T                                                                    ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                 Page 3 of 29




                                     Test Report Certification

             Applicant          :   Carewell Electric Technology (Zhongshan) Co., Ltd.
             Manufacturer       :   Carewell Electric Technology (Zhongshan) Co., Ltd.
             EUT Description    :   REMOTE CONTROL
                                     (A) MODEL NO.:FAN-53T
                                     (B) SERIAL NO.: N/A
                                     (C) POWER SUPPLY: DC 9V (Battery 1x)

             Measurement Procedure Used:

             FCC Rules and Regulations Part 15 Subpart C Section 15.231a
             ANSI C63.4-2009

             The device described above is tested by ACCURATE TECHNOLOGY CO., LTD to
             determine the maximum emission levels emanating from the device. The maximum emission
             levels are compared to the FCC Part 15 Subpart C Section 15.231a. The measurement results
             are contained in this test report and ACCURATE TECHNOLOGY CO., LTD is assumed full
             responsibility for the accuracy and completeness of these measurements. Also, this report
             shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC
             requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of ACCURATE TECHNOLOGY CO., LTD.

             Date of Test :                                       Nov 08-15, 2013


             Prepared by :



                                                                     (Engineer)


             Approved & Authorized Signer :



                                                                     (Manager)




FCC ID: 2AAZPFAN53T                                      ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                 Page 4 of 29




         1. GENERAL INFORMATION


                1.1.Description of Device (EUT)
                      EUT               : REMOTE CONTROL
                      Model Number      : FAN-53T

                      Power Supply      : DC 9V (battery 1x)

                      Modulation:       : ASK

                      Operation Frequency : 303.9MHz

                      Applicant         : Carewell Electric Technology (Zhongshan) Co., Ltd.
                      Address           : Torch Development Zone, No.2, Ouya Road,
                                          Zhongshan,Guangdong,China

                      Manufacturer      : Carewell Electric Technology (Zhongshan) Co., Ltd.
                      Address           : Torch Development Zone, No.2, Ouya Road,
                                          Zhongshan,Guangdong,China

                      Date of sample    : Nov 08, 2013
                      received
                      Date of Test      : Nov 08-15, 2013




FCC ID: 2AAZPFAN53T                                      ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                   Page 5 of 29




                1.2.Description of Test Facility
                      EMC Lab                :   Accredited by TUV Rheinland Shenzhen

                                                 Listed by FCC
                                                 The Registration Number is 752051

                                                 Listed by Industry Canada
                                                 The Registration Number is 5077A-2

                                                 Accredited by China National Accreditation Committee
                                                 for Laboratories
                                                 The Certificate Registration Number is L3193

                      Name of Firm           :   ACCURATE TECHNOLOGY CO., LTD
                      Site Location          :   F1, Bldg. A, Changyuan New Material Port, Keyuan Rd.
                                                 Science & Industry Park, Nanshan, Shenzhen, Guangdong
                                                 P.R. China


                1.3.Measurement Uncertainty
                      Conducted Emission Expanded Uncertainty    =    2.23dB, k=2

                      Radiated emission expanded uncertainty     =    3.08dB, k=2
                      (9kHz-30MHz)

                      Radiated emission expanded uncertainty     =    4.42dB, k=2
                      (30MHz-1000MHz)

                      Radiated emission expanded uncertainty     =    4.06dB, k=2
                      (Above 1GHz)




FCC ID: 2AAZPFAN53T                                        ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                              Page 6 of 29




          2. MEASURING DEVICE AND TEST EQUIPMENT
                Table 1: List of Test and Measurement Equipment
Kind of equipment Manufacturer         Type          S/N              Calibrated date     Calibrated until
EMI Test Receiver Rohde&Schwarz        ESCS30        100307           Jan. 12, 2013       Jan. 11, 2014
EMI Test Receiver Rohde&Schwarz        ESPI3         101526/003       Jan. 12, 2013       Jan. 11, 2014
Spectrum Analyzer Agilent              E7405A        MY45115511       Jan. 12, 2013       Jan. 11, 2014
Pre-Amplifier          Rohde&Schwarz   CBLU118354 3791                Jan. 12, 2013       Jan. 11, 2014
                                       0-01
Loop Antenna           Schwarzbeck     FMZB1516   1516131             Feb. 06, 2013       Feb. 05, 2014
Bilog Antenna          Schwarzbeck     VULB9163      9163-323         Feb. 06, 2013       Feb. 05, 2014
Horn Antenna           Schwarzbeck     BBHA9120D     9120D-655        Feb. 06, 2013       Feb. 05, 2014
Horn Antenna           Schwarzbeck     BBHA9170      9170-359         Feb. 06, 2013       Feb. 05, 2014
LISN                   Rohde&Schwarz   ESH3-Z5       100305           Jan. 12, 2013       Jan. 11, 2014
LISN                   Schwarzbeck     NSLK8126      8126431          Jan. 12, 2013       Jan. 11, 2014




 FCC ID: 2AAZPFAN53T                                  ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                   Page 7 of 29




         3. SUMMARY OF TEST RESULTS

               FCC Rules               Description of Test     Result
               Section 15.207          Conducted Emission      N/A
               Section 15.231(b)       Radiated Emission       Compliant
               Section 15.231(c)       20dB Bandwidth          Compliant
               Section 15.231(a)(1)    Release Time        Compliant
                                       Measurement
               Section 15.203          Antenna Requirement Compliant
              The product is a manually operated REMOTE CONTROL transmitter.
              Section 15.231 (a) (2), (3), (4) and (5) are not applicable.

              All normal using modes of the normal function were tested but only the worst test data of the
              worst mode is recorded by this report.




FCC ID: 2AAZPFAN53T                                        ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                   Page 8 of 29




         4. THE FIELD STRENGTH OF RADIATION EMISSION


                4.1.Block Diagram of Test Setup
                          4.1.1.Block diagram of connection between the EUT and simulators

                                                EUT

                                     (EUT: REMOTE CONTROL)

                          4.1.2.Semi-Anechoic Chamber Test Setup Diagram

                                   ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

                                                   3 METERS




                                                                             EUT

                      Cable
                                                                                        0.8 METER



                                    GROUND PLANE

                                     (EUT: REMOTE CONTROL)




FCC ID: 2AAZPFAN53T                                        ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                        Page 9 of 29




                4.2.The Field Strength of Radiation Emission Measurement Limits
                        4.2.1. Radiation Emission Measurement Limits According to FCC Part 15 Section
                               15.231(b)

                             Frequency Range of            Field Strength of             Field Strength of
                                                         Fundamental Emission           Spurious Emission
                                Fundamental                   [Average]                     [Average]
                                   [MHz]                        [V/m]                        [V/m]
                                40.66-40.70                       2250                          225
                                   70-130                         1250                          125
                                  130-174                      1250-3750                      125-375
                                  174-260                         3750                          375
                                  260-470                     3750-12500                     375-1250
                                Above 470                        12500                         1250
                        Where F is the frequency in MHz, the formulas for calculating the maximum
                        permitted fundamental field strengths are as follows: for the band 130-174 MHz,
                        uV/m at 3 meters = 56.81818(F) - 6136.3636; for the band 260-470 MHz, uV/m at
                        3 meters = 41.6667(F) - 7083.3333. The maximum permitted unwanted emission
                        level is 20 dB below the maximum permitted fundamental level.
                        4.2.2. Restricted Band Radiation Emission Measurement Limits According to FCC
                               part 15 Section 15.205 and Section15.209.


                4.3.Configuration of EUT on Measurement
                      The following equipment is installed on Radiated Emission Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to
                      maximize its emission characteristics in normal application.
                        4.3.1. REMOTE CONTROL (EUT)
                             Model Number         :   FAN-53T
                             Serial Number        :   N/A
                             Manufacturer         :   Carewell Electric Technology (Zhongshan) Co., Ltd.




                4.4.Operating Condition of EUT
                        4.4.1.Setup the EUT and simulator as shown as Section 4.1.

                        4.4.2.Turn on the power of all equipment.

                        4.4.3. Let the EUT work in TX mode measure it.




FCC ID: 2AAZPFAN53T                                           ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                   Page 10 of 29




                4.5.Test Procedure
                      The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                      ground. The turntable can rotate 360 degrees to determine the position of the
                      maximum emission level. EUT is set 3.0 meters away from the receiving antenna,
                      which is mounted on an antenna tower. The antenna can be moved up and down
                      between 1.0 meter and 4 meters to find out the maximum emission level. Broadband
                      antenna (calibrated bi-log antenna) is used as receiving antenna. Both horizontal and
                      vertical polarizations of the antenna are set on measurement. In order to find the
                      maximum emission levels, all of the EUT location must be manipulated according to
                      ANSI C63.4 on radiated emission measurement. The EUT was tested in 3 orthogonal
                      planes.

                      The bandwidth of test receiver is set at 120 kHz in 30-1000 MHz, and 1 MHz in
                      1000-4000 MHz.

                      The frequency range from 30 MHz to 4000 MHz is checked.




FCC ID: 2AAZPFAN53T                                         ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                        Page 11 of 29




                 4.6.The Field Strength of Radiation Emission Measurement Results
                         PASS.

                         The frequency range 30MHz to 4000MHz is investigated.

Date of Test:         Nov 14, 2013                        Temperature:         25oC
EUT:                  REMOTE CONTROL                      Humidity:            50%
Model No.:            FAN-53T                             Power Supply:        DC 9V
Test Mode:            TX                                  Test Engineer:       Ricky

Frequency       Reading       Factor    Average   Result(dBV/m)   Limit(dBV/m)       Margin(dB)        Polarization
 (MHz)       (dBV/m)          Corr.    Factor
                 PEAK            (dB)    (dB)      AV     PEAK      AV     PEAK        AV      PEAK
 303.90          70.04        -9.24     -12.14    48.66    60.80    74.9    94.9     -26.24    -34.10
 607.80          46.55        -2.85     -12.14    31.56   43.70     54.9    74.9     -23.34    -31.20
 2127.30         52.19        -8.46     -12.14    31.59   43.73     54.9    74.9     -23.31    -31.17     Horizontal
 3039.00         51.46        -4.88     -12.14    34.44   46.58     54.9    74.9     -20.46    -28.32
 3646.80         48.17        -2.72     -12.14    33.31   45.45     54.9    74.9     -21.59    -29.45
 303.90          64.6         -9.24     -12.14    43.22    55.36    74.9    94.9     -31.68    -39.54
 607.80          45.84        -2.85     -12.14    30.85    42.99    54.9    74.9     -24.05    -31.91
 1823.40         55.58        -9.89     -12.14    33.55    45.69    54.9    74.9     -21.35    -29.21      Vertical
 2127.30         52.60        -8.46     -12.14    32.00    44.14    54.9    74.9     -22.90    -30.76
 3039.00         54.65        -4.88     -12.14    34.63    46.77    54.9    74.9     -20.27    -28.13
Note:
1. Emissions attenuated more than 20 dB below the permissible value are not reported.
2. *: Denotes restricted band of operation.
  Measurements were made using a peak detector. Any emission falling within the restricted bands of FCC
  Part 15 Section 15.205 were compliance with the emission limit of FCC Part 15 Section 15.209.
3. The field strength is calculated by adding the antenna factor, high pass filter loss(if used) and cable loss,
   and subtracting the amplifier gain(if any)from the measured reading. The basic equation calculation is
   as follows:
  Result = Reading + Corrected Factor
  Where Corrected Factor = Antenna Factor + Cable Loss + High Pass Filter Loss – Amplifier Gain
4. FCC Limit for Average Measurement = 41.6667(303.9)-7083.3333 = 10996.79246 V/m =74.9 V/m
5. The spectral diagrams in appendix I display the measurement of peak values.
6. Average value= PK value + Average Factor (duty factor)
7. Pulse Desensitization Correction Factor
  Pulse Width (PW) = 5.34ms
FCC ID: 2AAZPFAN53T                                            ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                            Page 12 of 29


  1/PW = 1/5.34ms = 0.187kHz
  RBW (100 kHz) > 1/PW (0.187 kHz)
  Therefore PDCF is not needed




FCC ID: 2AAZPFAN53T                  ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                  Page 13 of 29




         5. 20DB OCCUPIED BANDWIDTH


                5.1.Block Diagram of Test Setup
                          5.1.1.Block diagram of connection between the EUT and simulators

                                                EUT

                                     (EUT: REMOTE CONTROL)

                          5.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                   3 METERS




                                                                            EUT

                      Cable
                                                                                        0.8 METER



                                    GROUND PLANE

                                    (EUT: REMOTE CONTROL)


                5.2.The Bandwidth of Emission Limit According To FCC Part 15 Section

                       15.231(c)
                       The bandwidth of emission shall be no wider than 0.25% of the center frequency.
                       Therefore, the bandwidth of the emission limit is 433.92 MHz×0.25% = 1.0848 MHz.
                       Bandwidth is determined at the two points 20 dB down from the top of modulated
                       carrier.




FCC ID: 2AAZPFAN53T                                        ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                    Page 14 of 29




                5.3.EUT Configuration on Measurement
                      The following equipment are installed on the bandwidth of emission Measurement to
                      meet the commission requirements and operating regulations in a manner which tends
                      to maximize its emission characteristics in normal application.
                         5.3.1.REMOTE CONTROL (EUT)
                              Model Number      :   FAN-53T
                              Serial Number     :   N/A
                              Manufacturer      :   Carewell Electric Technology (Zhongshan) Co., Ltd.




                5.4.Operating Condition of EUT
                         5.4.1.Setup the EUT and simulator as shown as Section 5.1.

                         5.4.2.Turn on the power of all equipment.

                         5.4.3.Let the EUT work in TX mode measure it.


                5.5.Test Procedure
                         5.5.1. Set SPA Center Frequency = Fundamental frequency, RBW = 10 kHz, VBW
                                = 30 kHz, Span = 500 kHz.

                         5.5.2.Set SPA Max hold, Mark peak, -20 dB.


                5.6.Measurement Result

                      The EUT does meet the FCC requirement.


                      -20 dB bandwidth = 53.0 kHz <759.75KHz.

                      The spectral diagrams in appendix I.




FCC ID: 2AAZPFAN53T                                          ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                   Page 15 of 29




         6. RELEASE TIME MEASUREMENT


                6.1.Block Diagram of Test Setup
                          6.1.1.Block diagram of connection between the EUT and simulators

                                                 EUT

                                     (EUT: REMOTE CONTROL)

                          6.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                    3 METERS




                                                                             EUT

                      Cable
                                                                                         0.8 METER



                                    GROUND PLANE

                                     (EUT: REMOTE CONTROL)


                6.2.Release Time Measurement According To FCC Part 15 Section 15.231(a)
                       Section 15.231(a) (1) A manually operated transmitter shall employ a switch that will
                       automatically deactivate the transmitter within not more than 5 seconds of being
                       released.




FCC ID: 2AAZPFAN53T                                         ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                     Page 16 of 29




                6.3.EUT Configuration on Measurement
                      The following equipment are installed on Release Time Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to
                      maximize its emission characteristics in normal application.
                         6.3.1. REMOTE CONTROL (EUT)
                              Model Number      :   FAN-53T
                              Serial Number     :   N/A
                              Manufacturer      :   Carewell Electric Technology (Zhongshan) Co., Ltd.




                6.4.Operating Condition of EUT
                         6.4.1.Setup the EUT and simulator as shown as Section 6.1.

                         6.4.2.Turn on the power of all equipment.

                         6.4.3.Let the EUT work in TX mode measure it.


                6.5.Test Procedure
                         6.5.1. Set SPA Center Frequency = Fundamental frequency, RBW = 100 kHz, VBW
                                = 300 kHz, Span = 0 Hz. Sweep time = 10 s.

                         6.5.2.Set EUT as normal operation and press Transmitter button.

                         6.5.3.Set SPA View. Delta Mark time.


                6.6. Measurement Result

                      The release time less than 5 seconds.


                      Release Time = 2.68s

                      The spectral diagrams in appendix I.




FCC ID: 2AAZPFAN53T                                           ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                       Page 17 of 29




         7. AVERAGE FACTOR MEASUREMENT


                7.1.Block Diagram of Test Setup
                          7.1.1.Block diagram of connection between the EUT and simulators

                                                 EUT

                                  (EUT: REMOTE CONTROL)

                          7.1.2.Semi-Anechoic Chamber Test Setup Diagram


                                     ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS


                                                      3 METERS




                                                                                 EUT

                      Cable
                                                                                            0.8 METER


                                     GROUND PLANE
                                  (EUT: REMOTE CONTROL)


                7.2.Average factor Measurement according to ANSI C63.4-2009
                 ANSI C63.4-2009 Section 13.4.2 Devices transmitting pulsed emissions and subject to a
                 limit requiring an average detector function for radiated emissions shall initially be
                 measured with an instrument that uses a peak detector. A radiated emission measured
                 with a peak detector may then be corrected to a true average using the appropriate factor
                 for emission duty cycle. This correction factor relates the measured peak level to the
                 average limit and is derived by averaging absolute field strength over one complete pulse
                 train that is 0.1 s, or less, in length. If the pulse train is longer than 0.1 s, the average shall
                 be determined from the average absolute field strength during the 0.1 s interval in which
                 the field strength is at a maximum.
                 Average factor in dB = 20 log (duty cycle)



FCC ID: 2AAZPFAN53T                                            ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                     Page 18 of 29




                7.3.EUT Configuration on Measurement
                      The following equipment are installed on average factor Measurement to meet the
                      commission requirements and operating regulations in a manner which tends to
                      maximize its emission characteristics in normal application.
                         7.3.1. REMOTE CONTROL (EUT)
                              Model Number      :   FAN-53T
                              Serial Number     :   N/A
                              Manufacturer      :   Carewell Electric Technology (Zhongshan) Co., Ltd.




                7.4.Operating Condition of EUT
                         7.4.1.Setup the EUT and simulator as shown as Section 7.1.

                         7.4.2.Turn on the power of all equipment.

                         7.4.3.Let the EUT work in TX mode measure it.


                7.5.Test Procedure
                         7.5.1.The time period over which the duty cycle is measured is 100 milliseconds, or
                               the repetition cycle, whichever is a shorter time frame. The worst case
                               (highest percentage on) duty cycle is used for the calculation.

                         7.5.2.Set SPA Center Frequency = Fundamental frequency, RBW = 100 kHz, VBW
                               = 300 kHz, Span = 0 Hz.

                         7.5.3.Set EUT as normal operation.

                         7.5.4.Set SPA View. Delta Mark time.


                7.6. Measurement Result

                      The duty cycle is simply the on time divided by the period:

                      The duration of one cycle = 21.60 ms

                      Effective period of the cycle = (0.36×11) + (0.69×2)ms=5.34 ms

                      DC = 5.34ms/21.60ms=0.247

                      Therefore, the average factor is found by 20log0.247=-12.14dB

                      The spectral diagrams in appendix I.

FCC ID: 2AAZPFAN53T                                           ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                     Page 19 of 29




          8. ANTENNA REQUIREMENT


                8.1.The Requirement
                      According to Section 15.203, an intentional radiator shall be designed to ensure that no
                      antenna other than that furnished by the responsible party shall be used with the device.


                8.2.Antenna Construction
                      Device is equipped with unique antenna, which isn’t displaced by other antenna.
                      Therefore, the equipment complies with the antenna requirement of Section 15.203.




                                           Antenna




FCC ID: 2AAZPFAN53T                                           ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                     Page 20 of 29




                      APPENDIX I
                      (Test Curves)




FCC ID: 2AAZPFAN53T           ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                          ACCURATE TECHNOLOGY CO., LTD.                                                       Site: 2# Chamber
                                          F1,Bidg.A, Changyuan New Material Port Keyuan Rd,                         Tel:+86—0755—26503290
@E)                                       Science & Industry Park,Nanshan Shenzhen,P.R.China                        Fax: +86—0755—26503396
Job No.:         RUCKY #538                                                             Polarization:          Horizontal
Standard: FCC Class B 3M Radiated                                                       Power Source:            DC 9V
Test item:           Radiation Test                                                     Date: 13/11/14/
Temp.( C)Hum.(%) 23 C/48%                                                               Time: 8/46/38
EUT:                 REMOTE CONTROL                                                     Engineer Signature:              Ricky
Mode:            Operation                                                              Distance:      3m
Model:           FAN—53T
Manufacturer: Carewell
Note:          Report No.:ATE20132396



      70.0      dBw/m
                                                                                                                    limitt




      a0




      10

      0.0                             I    I    I                                   i                                     I        1
            30.000     40    50     co     70   to                                  300         400       500—    600     700.   1000.0 WHz


                 Freq.        Reading           Factor      Result    Limit   [Margin                 Height     Degree
Ns:             (MHz)        (dBuVim)               (d8)   (dBuVim) (dBuVim) (4B) |P"°C°| (em)                   (dea)         °m
1                303.9000|        70.04             —824    6080      46.00    14.80] peak
2                6o7.8000|        4655              285     4370      46.00    230| peak


                            ®               ACCURATE TECHNOLOGY CO., LTD.                                                          Site: 2# Chamber
                                            F1,Bidg.A,Changyuan New Material Port Keyuan Rd,                                 Tel:+86—0755—26503290
                                            Science & Industry Park,Nanshan Shenzhen,P.R.China                               Fax:+86—0755—26503396
Job No.:        RUCKY #539                                                                     Polarization:         Vertical
Standard: FCC Class B 3M Radiated                                                              Power Source:           DC 9V
Test item:          Radiation Test                                                             Date: 13/11/14/
Temp.( C)‘Hum.(%) 23 C/48%                                                                     Time: 8/47/01
EUT:                REMOTE CONTROL                                                             Engineer Signature:              Ricky
Mode:           Operation                                                                      Distance:      3m
Model:              FAN—53T
Manufacturer: Carewell
Note:         Report No.:ATE20132396



      70.0     dBw¥/m
                                                                                                                             limitt:      —

      so


      so


      «0


      30


      20


      10

      0.0               I       I       1     I     I                                      i                             i                 I
           30.000      40       50     co     70|   80                                  300           400       500—    600      700     1000.0 MHiz


                Freq.               Reading         Factor       Result   Limit   |Margin                   Height     Degree
No.            (MHz)            (dBuVim)                (d8B)   (dBuVim) (dBuvim)| (4B) P"°C° (em)                     (ea)            R°me*
1               303.7400|            6460           924          5536     46.00    936            peak
2               6074800|             4584           285          4299     46.00    —301|          peak


                         ®          ACCURATE TECHNOLOGY CO., LTD.                                         Site: 2# Chamber
                                    F1,Bidg.A,Changyuan New Material Port Keyuan Rd,                Tel:+86—0755—26503290
                                    Science & Industry Park,Nanshan Shenzhen,P.R.China              Fax:+86—0755—26503396
Job No.:         RUCKY #535                                                Polarization:       Vertical
Standard: FCC Class B 3M Radiated                                          Power Source:          DC 9V
Test item:         Radiation Test                                          Date: 13/11/14/
Temp.( C)/Hum.(%) 23 C/48%                                                 Time: 841/22
EUT:              REMOTE CONTROL                                           Engineer Signature:         Ricky
Mode:            Operation                                                 Distance:     3m
Model:           FAN—S53T
Manufacturer: Carewell
Note:          Report No.:ATE20132396



      70.0      dBuV/m
                                                                                                    limitt:     —

      so


      so


      a0


      30


      20




      0.0                                                                                  i
            1000.000                                                                       3000                4000.0. MHz



 No             firey        Geavid @6)"_| «aBuvim casuu| Ne| Cerecer| NEB)! CS| remer
1                1823400]     s558  980 4569        54.00 —8.31| peak
2               2127300|      5260| 646 4414        5400 986| peak
3                3030.000|    S165s 486 4677        54.00 723] peak


                        ®          ACCURATE TECHNOLOGY CO., LTD.                                             Site: 2# Chamber
                                     F1,Bidg.A,Changyuan New Material Port Keyuan Rd,                  Tel:+86—0755—28503290
                                     Science & Industry Park,Nanshan Shenzhen,P.R.China                Fax:+86—0755—26503396
Job No.:        RUCKY #536                                                   Polarization:        Vertical
Standard: FCC Class B 3M Radiated                                            Power Source:          DC 9V
Test item:        Radiation Test                                             Date: 13/11/14/
Temp.( C)Hum.(%) 23 C/48%                                                    Time: 8142720
EUT:             REMOTE CONTROL                                              Engineer Signature:            Ricky
Mode:           Operation                                                    Distance:       3m
Model:          FAN—53T
Manufacturer: Carewell
Note:         Report No.:ATE20132396



     70.0      dBu¥/m
                                                                                                       limit1:



     co




     5o




     40




     30




     20




     10



     0.0                                                                                     i

           1000.000                                                                          3000                   4000.0° MHz


                Freq.       Reading      Factor    Result      Limit   |Margin           Height     Degree
NS             (MHz)        (dBuVim)      (d8)    (dBuVim) (dBuvim)| (dB) P49| (em)                 (aea)        R®m=*
1               2127.300|    5219         —646     4373        54.00   |—10.27| peak
7               3030.000|    5146         488      46586       54.00    742| peak
3               3646.800|    48617        272      4545        54.00    855| peak


                                                                                                             Page 25 of 29




                                                             * RBW 10 kHz   Delta 1 [T1 ]
                                                             * VBW 30 kHz               0.68 dB
              Ref    90 dBµV             * Att   10 dB       * SWT 5 ms         53.000000000 kHz
              90    Offset    1 dB                                          Marker 1 [T1 ]
                                                                                      50.42 dBµV
                                                                               303.907000000 MHz      A
              80

       1 PK
       MAXH            D1 71.03 dBµV
              70
                                                                                                     LVL


              60

                                                     1         1
              50             D2 51.03 dBµV



              40

                                                                                                     3DB
              30



              20



              10



              0
                                                               F2
                                                    F1
              -10

              Center 303.934 MHz                         50 kHz/                      Span 500 kHz




      Date: 14.NOV.2013              08:50:47




FCC ID: 2AAZPFAN53T                                                   ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                       Page 26 of 29




                                                       RBW 100 kHz        Delta 1 [T1 ]
                                                      * VBW 300 kHz                   1.63 dB
              Ref   87 dBµV           Att   10 dB      SWT 10 s                   2.680000 s

                                                                          Marker 1 [T1 ]
              80                                                                    24.70 dBµV
                                                                                  4.380000 s      A
                                                                                                 SGL
       1 PK
              70
       MAXH


              60



              50



              40



              30                                                                                 3DB
                                                                      1
                                               1


              20



              10



              0



              -10

              Center 303.9 MHz                      1 s/




      Date: 14.NOV.2013          08:33:20



Release Time = 2.68s




FCC ID: 2AAZPFAN53T                                           ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                           Page 27 of 29




                                                     RBW 100 kHz     Delta 1 [T1 ]
                                                    * VBW 300 kHz                0.43 dB
        Ref   100 dBµV           * Att   10 dB       SWT 100 ms             21.600000 ms
        100 Offset    1 dB                                           Marker 1 [T1 ]
                                                                               26.40 dBµV
                                                                            45.400000 ms     A
        90
                                                                                            SGL
 1 PK
 MAXH
        80
                                                                                            LVL


        70



        60



        50

                                                                                            3DB
        40



        30                                   1                 1


        20



        10


        0

        Center 303.9 MHz                         10 ms/




 Date: 15.NOV.2013           08:52:39




The graph shows the pattern of coding during the signal transmission.
The duration of one cycle = 21.60 ms.




FCC ID: 2AAZPFAN53T                                                 ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                       Page 28 of 29




                                                 RBW 100 kHz    Marker 1 [T1 ]
                                                * VBW 300 kHz             20.41 dBµV
       Ref   87 dBµV           Att   10 dB       SWT 15 ms              8.910000 ms

                                                                Delta 1 [T1 ]
       80                                                                   0.62 dB
                                                                      690.000000 µs     A
                                                                                       SGL
1 PK
       70
MAXH


       60



       50



       40



       30                                                                              3DB


                                                       1   1
       20



       10



       0



       -10

       Center 303.9 MHz                      1.5 ms/




Date: 14.NOV.2013         08:22:16




The graph shows the duration of ‘on’ signal. From marker 1 to marker 2, duration is 0.69ms.




FCC ID: 2AAZPFAN53T                                             ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396


                                                                                                           Page 29 of 29




                                                      RBW 100 kHz   Delta 1 [T1 ]
                                                  * VBW 300 kHz                -3.73 dB
       Ref   87 dBµV           Att   10 dB            SWT 15 ms           360.000000 µs

                                                                    Marker 1 [T1 ]
       80                                                                     19.91 dBµV
                                                                            7.470000 ms     A
                                                                                           SGL
1 PK
       70
MAXH


       60



       50



       40



       30                                                                                  3DB


                                              1
       20                                         1


       10



       0



       -10

       Center 303.9 MHz                      1.5 ms/




Date: 14.NOV.2013         08:23:11




The graph shows the duration of ‘on’ signal. From marker 1 to marker 2, duration is 0.36 ms.




FCC ID: 2AAZPFAN53T                                                 ACCURATE TECHNOLOGY CO., LTD REPORT NO. ATE20132396



Document Created: 2019-09-24 18:51:52
Document Modified: 2019-09-24 18:51:52

© 2024 FCC.report