Part 15B Test Report

FCC ID: 2AAV8QH-9826A

Test Report

Download: PDF
FCCID_2765171

                FCC Test Report
        FCC ID:2AAV8QH-9826A

               Product: Main unit(receiver)
           Trade Name: QUHWA
           Model Name: QH-9826A
           Serial Model: N/A
            Report No.: NTEK-2015NT0813492F




                           Prepared for

          SHENZHEN QIAOHUA INDUSTRIES LIMITED
Qiaohua Industrial Zone, Luo Tian Forestry Center, Song Gang Town,
      Bao An District, Shenzhen, Guangdong, 518105 China


                           Prepared by

            Shenzhen NTEK Testing Technology Co., Ltd.
1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street,
                   Bao’an District, Shenzhen P.R. China
           Tel.: +86-0755-61156588 Fax.: +86-0755-61156599
                        Website: www.ntek.org.cn


                                                                Page 2 of 19        Report No.: NTEK-2015NT0813492F



                                         TEST RESULT CERTIFICATION

Applicant’s name ................. : SHENZHEN QIAOHUA INDUSTRIES LIMITED
Address ................................. : Qiaohua Industrial Zone, Luo Tian Forestry Center, Song Gang
                                            Town, Bao An District, Shenzhen, Guangdong, 518105 China
Manufacture's Name ............ : SHENZHEN QIAOHUA INDUSTRIES LIMITED
Address ................................. : Qiaohua Industrial Zone, Luo Tian Forestry Center, Song Gang
                                            Town, Bao An District, Shenzhen, Guangdong, 518105 China
Product description
Product name ........................... : Main unit(receiver)
Model and/or type reference : QH-9826A
                                          FCC Part15B:01 Oct.2014
Standards ............................. :
                                          ANSI C63.4:2014
This device described above has been tested by NTEK, and the test results show that the
equipment under test (EUT) is in compliance with Part 15 of FCC Rules. And it is applicable only to
the tested sample identified in the report.
This report shall not be reproduced except in full, without the written approval of NTEK, this
document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of
the document.
Date of Test ............................................ :
Date (s) of performance of tests ............. :                13 Aug. 2015 ~25 Aug. 2015
Date of Issue ........................................... :     25 Aug. 2015
Test Result ............................................... :   Pass



                          Testing Engineer                  :

                                                                               (Allen Liu)


                          Technical Manager                 :

                                                                               (Brown Lu)


                          Authorized Signatory :

                                                                               (Sam Chen)


                                Page 3 of 19   Report No.: NTEK-2015NT0813492F




                        Table of Contents                            Page


1 . TEST SUMMARY                                                            4
  1.1 TEST FACILITY                                                         5
  1.2 MEASUREMENT UNCERTAINTY                                               5
2 . GENERAL INFORMATION                                                     6
  2.1 GENERAL DESCRIPTION OF EUT                                            6
  2.2 DESCRIPTION OF TEST SETUP                                             8
  2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL                        9
  2.4 MEASUREMENT INSTRUMENTS LIST                                       10
3 . EMC EMISSION TEST                                                    11
  3.1 CONDUCTED EMISSION MEASUREMENT                                     11
     3.1.1 POWER LINE CONDUCTED EMISSION                                 11
     3.1.2 TEST PROCEDURE                                                12
     3.1.3 TEST SETUP                                                    12
     3.1.4 EUT OPERATING CONDITIONS                                      12
     3.1.5 TEST RESULTS                                                  13
  3.2 RADIATED EMISSION MEASUREMENT                                      14
     3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT                       14
     3.2.2 TEST PROCEDURE                                                14
     3.2.3 TEST SETUP                                                    15
     3.2.4 TEST RESULTS                                                  16
     3.2.5 TEST RESULTS(1000~12400MHz)                                   18
4 . EUT TEST PHOTO                                                      19


                                           Page 4 of 19       Report No.: NTEK-2015NT0813492F


1. TEST SUMMARY

Test procedures according to the technical standards:
                                         EMC Emission

          Standard                      Test Item               Limit       Judgment   Remark

                                  Conducted Emission           Class B         N/A
     FCC Part15B:2014
     ANSI C63.4: 2014
                                   Radiated Emission           Class B        PASS
NOTE:
    (1) ’N/A’ denotes test is not applicable in this Test Report
    (2) For client’s request and manual description, the test will not be executed.


                                          Page 5 of 19       Report No.: NTEK-2015NT0813492F


1.1 TEST FACILITY
   NTEK Testing Technology Co., Ltd
   Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
  Shenzhen P.R. China.
   FCC Registration Number:238937; IC Registration Number:9270A-1
   CNAS Registration Number:L5516
1.2 MEASUREMENT UNCERTAINTY
  The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
  standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
  approximately 95 %.

  A. Conducted Measurement :

     Test Site Method        Measurement Frequency Range         U,(dB)          NOTE
     NTEKC01 ANSI                 150 KHz ~ 30MHz                 3.2

  B. Radiated Measurement :

     Test Site Method        Measurement Frequency Range         U,(dB)          NOTE
     NTEKA01 ANSI                 30MHz ~ 1000MHz                 4.7
                                   1GHz ~12.4GHz                  5.0


                                             Page 6 of 19    Report No.: NTEK-2015NT0813492F


2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT




 Equipment             Main unit(receiver)
 Model Name            QH-9826A
 Additional Model
                       N/A
 Number(s)
 Model Difference      N/A

                        The EUT is a Main unit(receiver) .


 Product Description    Operation Frequency:         433.92MHz
                        Modulation Type:             ASK


 Power Source          DC Voltage
 Adapter               N/A
 Battery               1.5V*3 cell ”AAA” alkaline battery


                                             Page 7 of 19        Report No.: NTEK-2015NT0813492F

2.1.1 DESCRIPTION OF TEST MODES

    To investigate the maximum EMI emission characteristics generates from EUT, the test
    system was pre-scanning tested base on the consideration of following EUT operation
    mode or test configuration mode which possible have effect on EMI emission level.
    Each of these EUT operation mode(s) or test configuration mode(s) mentioned above
    was evaluated respectively.

              Pretest Mode                              Description
                 Mode 1                           normal working Mode



                                       For Radiated Test
             Final Test Mode                           Description
                 Mode 1                            normal working Mode
    Note: Final Test Mode: Through Pre-scan, find the mode 1 is the worse case.
    Only the worst case mode is recorded in the report.


                                Page 8 of 19   Report No.: NTEK-2015NT0813492F


2.2 DESCRIPTION OF TEST SETUP




                                    E-1
                                    EUT


                                              Page 9 of 19      Report No.: NTEK-2015NT0813492F


2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL

The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

Item         Equipment               Brand          Model/Type No.       Series No.       Note
 E-1     Main unit(receiver)       QUHWA              QH-9826A              N/A            EUT




Item        Shielded Type      Ferrite Core      Length                      Note




 Note:
  (1)      The support equipment was authorized by Declaration of Confirmation.
  (2)      For detachable type I/O cable should be specified the length in cm in『Length』column.
  (3)      “YES” means “shielded” “with core”; “NO” means “unshielded” “without core”.


                                             Page 10 of 19      Report No.: NTEK-2015NT0813492F


2.4 MEASUREMENT INSTRUMENTS LIST

2.4.1 CONDUCTED TEST SITE
                                                                                                    Calibra
         Kind of
 Item             Manufacturer      Type No.       Serial No.   Last calibration Calibrated until    tion
        Equipment
                                                                                                    period
  1       LISN         R&S          ENV216           101313      Jul. 06, 2015    Jul. 05, 2016     1 year
                   SCHWARZBE
  2       LISN                     NNLK 8129        8129245     Dec. 25, 2014 Dec. 24, 2015 1 year
                      CK
          Pulse    SCHWARZBE
  3                               VTSD 9561F          9716      Dec. 25, 2014 Dec. 24, 2015 1 year
          Limiter     CK
                    ANRITSU
  4     50Ω Switch                  MP59B         6200983704     Jul. 06, 2015    Jul. 05, 2016     1 year
                     CORP
  5     Test Cable     N/A            C01             N/A        Jul. 06, 2015    Jul. 05, 2016     1 year
  6     Test Cable     N/A            C02             N/A        Jul. 06, 2015    Jul. 05, 2016     1 year
  7     Test Cable     N/A            C03             N/A        Jul. 06, 2015    Jul. 05, 2016     1 year
        EMI Test
  8                    R&S           ESCI            101160      Jul. 06, 2015    Jul. 05, 2016     1 year
        Receiver
         Passive
  9      Voltage     ESH2-Z3         R&S             100196      Jul. 06, 2015    Jul. 05, 2016     1 year
          Probe
        Absorbing
 10                    R&S          MDS-21           100423      Jul. 08, 2015    Jul. 07, 2016     1 year
         Clamp

2.4.2 RADIATED TEST SITE
                                                                                                    Calibra
         Kind of
 Item             Manufacturer      Type No.       Serial No.   Last calibration Calibrated until    tion
        Equipment
                                                                                                    period
          Bilog
  1                   TESEQ        CBL6111D          31216       Jul. 06, 2015    Jul. 05, 2016     1 year
         Antenna
  2     Test Cable     N/A           R-01             N/A       Dec. 25, 2014 Dec. 24, 2015 1 year
  3     Test Cable     N/A           R-02             N/A       Dec. 25, 2014 Dec. 24, 2015 1 year
         EMI Test
  4                    R&S          ESCI-7           101318      Jul. 06, 2015    Jul. 05, 2016     1 year
         Receiver
         Antenna
  5                     EM         SC100_1            N/A            N/A               N/A           N/A
          Mast
  6     Turn Table      EM          SC100            060531          N/A               N/A           N/A
  7     50Ω Switch Anritsu Corp     MP59B         6200983705     Jul. 06, 2015    Jul. 05, 2016     1 year
        Spectrum
  8                   Aglient       E4407B        MY45108040     Jul. 06, 2015    Jul. 05, 2016     1 year
        Analyzer
          Horn
  9                     EM        EM-AH-10180     2011071402     Jul. 06, 2015    Jul. 05, 2016     1 year
        Antenna
 10      Amplifier      EM         EM-30180          060538      Jul. 06, 2015    Jul. 05, 2016     1 year
          Loop
 11                    ARA        PLA-1030/B          1029       Jul. 06, 2015    Jul. 05, 2016     1 year
         Antenna


                                             Page 11 of 19    Report No.: NTEK-2015NT0813492F


3. EMC EMISSION TEST

3.1 CONDUCTED EMISSION MEASUREMENT

3.1.1 POWER LINE CONDUCTED EMISSION (Frequency Range 150KHz-30MHz)

                                    Class A (dBuV)                   Class B (dBuV)
   FREQUENCY (MHz)
                               Quasi-peak       Average      Quasi-peak         Average
         0.15 -0.5                79.00              66.00    66 - 56 *         56 - 46 *
         0.50 -5.0                73.00              60.00     56.00             46.00
        5.0 -30.0                73.00           60.00     60.00              50.00
       Note:
         (1) The tighter limit applies at the band edges.
         (2) The limit of " * " marked band means the limitation decreases linearly with the
             logarithm of the frequency in the range.



The following table is the setting of the receiver
               Receiver Parameters                                  Setting
                    Attenuation                                      10 dB
                 Start Frequency                                   0.15 MHz
                 Stop Frequency                                     30 MHz
                   IF Bandwidth                                      9 kHz


                                           Page 12 of 19       Report No.: NTEK-2015NT0813492F


3.1.2 TEST PROCEDURE
 a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.


3.1.3 TEST SETUP




3.1.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.


                                       Page 13 of 19     Report No.: NTEK-2015NT0813492F


3.1.5 TEST RESULTS


EUT:             Main unit(receiver)           Model Name. :      QH-9826A
Temperature:     26 ℃                          Relative Humidity: 54%
Pressure:        1010hPa                       Test Date :        N/A
Test Mode:       N/A                           Phase :            N/A
Test Voltage :   N/A


                                         Page 14 of 19        Report No.: NTEK-2015NT0813492F



3.2 RADIATED EMISSION MEASUREMENT

3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

                                   Class A (at 10m)                    Class B (at 3m)
  FREQUENCY (MHz)
                                       dBuV/m                             dBuV/m
        30 ~ 88                          39.0                               40.0
        88 ~ 216                         43.5                               43.5
       216 ~ 960                         46.5                               46.0
       Above 960                         49.5                               54.0

     Notes:
        (1) The limit for radiated test was performed according to as following:
            FCC PART 15B /ICES-003.
        (2) The tighter limit applies at the band edges.
        (3) Emission level (dBuV/m)=20log Emission level (uV/m).


3.2.2 TEST PROCEDURE
   Test Arrangement for Radiated Emissions up to 1 GHz
  a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an
      accredited test facility. The table was rotated 360 degrees to determine the position of the
      highest radiation.
  b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
      on the top of a variable-height antenna tower.
  c. The antenna is a broadband antenna, and its height is varied from one meter to four meters
     above the ground to determine the maximum value of the field strength. Both horizontal and
     vertical polarizations of the antenna are set to make the measurement.
  d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
     was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0
     degrees to 360 degrees to find the maximum reading.

  Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz
   for quasi-peak detection (QP) at frequency below 1GHz.
   Test Arrangement for Radiated Emissions above 1 GHz.

  a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an
     accredited chamber room. The table was rotated 360 degrees to determine the position of the
     highest radiation.
  b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
     on the top of a variable-height antenna tower.
  c. The height of antenna can be varied from one meter to four meters, the height of adjustment
     depends on the EUT height and the antenna 3dB beamwidth both, to detect the maximum
     value of the field strength.Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
  d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
     was tuned to heights and the rotatable table was turned from 0 degrees to 360 degrees to find
     the maximum reading.


                                          Page 15 of 19        Report No.: NTEK-2015NT0813492F

   Note:For the hand-held device, the EUT should be measured for all 3 axes and only the worst
      case is recorded in the report
During the radiated emission test, the Spectrum Analyzer was set with the following configurations:

      Frequency Band
                              Function        Resolution bandwidth       Video Bandwidth
           (MHz)
         30 to 1000              QP                  120 kHz                 300 kHz

                                Peak                  1 MHz                   1 MHz
        Above 1000
                                Peak                  1 MHz                   10 Hz

 3.2.3 TEST SETUP
 For Radiated Emission 30~1000MHz




 (B) Radiated Emission Test Set-Up Frequency Above 1GHz


                                          Page 16 of 19        Report No.: NTEK-2015NT0813492F


 3.2.4 TEST RESULTS

TEST RESULTS (30~1000 MHz)
 EUT:           Main unit(receiver)                  Model Name :       QH-9826A
 Temperature:   24 ℃                                 Relative Humidity: 54%
 Pressure:      1010 hPa                             Test Date :        2015-08-18
 Test Mode :    Mode 1                               Polarization :     Horizontal
 Test Power :   DC 4.5V


         Freq.     Reading       Factor    Measurement          Limit       Over
                                                                                     Remark
        (MHz)      (dBuV)        (dBuV)      (dBuV)            (dBuV)        (dB)
       32.2924      5.10         18.66        23.76            40.00       -16.24     QP
        66.266      7.44          6.58        14.02            40.00       -25.98     QP
        95.427      5.45         10.12        15.57            43.50       -27.93     QP
      152.1297      6.19         11.77        17.96            43.50       -25.54     QP
      332.5187      6.32         13.72        20.04            46.00       -25.96     QP
      435.5898      7.83         15.35        23.18            46.00       -22.82     QP
 Remark:
 Factor = Antenna Factor + Cable Loss - Amplifier.


                                         Page 17 of 19        Report No.: NTEK-2015NT0813492F


EUT:              Main unit(receiver)               Model Name :       QH-9826A
Temperature:      24 ℃                              Relative Humidity: 54%
Pressure:         1010 hPa                          Test Date :        2015-08-18
Test Mode :       Mode 1                            Polarization :     Vertical
Test Power :      DC 4.5V

        Freq.     Reading       Factor    Measurement          Limit       Over
                                                                                    Remark
       (MHz)      (dBuV)        (dBuV)      (dBuV)            (dBuV)        (dB)
      31.6202      6.89         18.99        25.88            40.00       -14.12     QP
      66.4989      9.03          6.79        15.82            40.00       -24.18     QP
     101.2883      6.74         10.26        17.00            43.50       -26.50     QP
     162.0414      9.04         11.56        20.60            43.50       -22.90     QP
     434.0649      8.21         15.21        23.42            46.00       -22.58     QP
     734.4913      8.05         21.88        29.93            46.00       -16.07     QP
Remark:

Factor = Antenna Factor + Cable Loss - Amplifier.


                                       Page 18 of 19         Report No.: NTEK-2015NT0813492F


3.2.5 TEST RESULTS(1000~12400MHz)

                                                  Emission
          Frequency   Meter Reading   Factor                     Limits   Margin
  Polar                                            Level
                                                                                    Remark
  (H/V)
            (MHz)         (dBm)        (dB)        (dBm)         (dBm)      (dB)
    V     1340.332       58.84       -12.78       46.06        74.00       -27.94    peak
    V     1340.332       46.36       -12.78       33.58        54.00       -20.42    AVG
    V     1587.100       62.11       -11.97       50.14        74.00       -23.86    peak
    V     1587.100       52.99       -11.97       41.02        54.00       -12.98    AVG
    V     2123.821       59.72        -8.28       51.44        74.00       -22.56    peak
    V     2123.821       48.86        -8.28       40.58        54.00       -13.42    AVG
    H      1197.525      62.77       -12.45       50.32        74.00       -23.68    peak
    H      1197.525      52.47       -12.45       40.02        54.00       -13.98    AVG
    H     1796.491       61.58       -10.87       50.71        74.00       -23.29    peak
    H     1796.491       50.12       -10.87       39.25        54.00       -14.75    AVG
    H     2427.350       56.05        -9.17       46.88        74.00       -27.12    peak
    H     2427.350       44.53        -9.17       35.36        54.00       -18.64    AVG
  Remark:
  Absolute Level= ReadingLevel+ Factor, Margin= Absolute Level - Limit


                           Page 19 of 19    Report No.: NTEK-2015NT0813492F