RF Test Report

FCC ID: 2AAV8QH9826A

Test Report

Download: PDF
FCCID_2758209

     FCC RADIO TEST REPORT
          FCC ID:2AAV8QH9826A

               Product: PIR sensor
           Trade Name: QUHWA
          Model Name: QH-9826A-PIR
          Serial Model: N/A
            Report No.: NTEK- 2015NT0813491F




                         Prepared for
          SHENZHEN QIAOHUA INDUSTRIES LIMITED
Qiaohua Industrial Zone, Luo Tian Forestry Center, Song Gang Town,
      Bao An District, Shenzhen, Guangdong, 518105 China




                         Prepared by
            Shenzhen NTEK Testing Technology Co., Ltd.
1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street
                  Bao’an District, Shenzhen P.R. China
          Tel.: +86-0755-61156588 Fax.: +86-0755-61156599
                        Website:www.ntek.org.cn


                                                           Page 2 of 26            Report No.:NTEK-2015NT0813491F



                                             TEST RESULT CERTIFICATION

    Applicant’s name ................. : SHENZHEN QIAOHUA INDUSTRIES LIMITED
    Address ................................. : Qiaohua Industrial Zone, Luo Tian Forestry Center, Song Gang
                                                Town, Bao An District, Shenzhen, Guangdong, 518105 China
    Manufacture's Name ............ : SHENZHEN QIAOHUA INDUSTRIES LIMITED
    Address ................................. : Qiaohua Industrial Zone, Luo Tian Forestry Center, Song Gang
                                                Town, Bao An District, Shenzhen, Guangdong, 518105 China
    Product description
    Product name ........................... : PIR sensor
    Model and/or type reference : QH-9826A-PIR
    Serial Model:                                    N/A
    Standards ............................. : FCC Part15.231               01 Oct. 2014

    Test procedure .............................. ANSI C63.10-2013
    This device described above has been tested by NTEK, and the test results show that the
    equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only
    to the tested sample identified in the report.
    This report shall not be reproduced except in full, without the written approval of NTEK, this
    document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of
    the document.
    Date of Test ............................................ :
    Date (s) of performance of tests ............. :                13 Aug. 2015 ~25 Aug. 2015
    Date of Issue ........................................... :     25 Aug. 2015
    Test Result ............................................... :   Pass



                              Testing Engineer                  :

                                                                                (Allen Liu)


                              Technical Manager                 :

                                                                               (Brown Lu)


                              Authorized Signatory :

                                                                               (Sam Chen)




`


                                 Page 3 of 26      Report No.:NTEK-2015NT0813491F




                               Table of Contents                        Page


    1 . SUMMARY OF TEST RESULTS                                                4
      1.1 TEST FACILITY                                                        5
      1.2 MEASUREMENT UNCERTAINTY                                              5
    2 . GENERAL INFORMATION                                                    6
      2.1 GENERAL DESCRIPTION OF EUT                                           6
      2.2 DESCRIPTION OF TEST MODES                                            7
      2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED              8
      2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)                         9
      2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS                                10
    3 . ANTENNA REQUIREMENT                                                 11
      3.1 STANDARD REQUIREMENT                                              11
      3.2 EUT ANTENNA                                                       11
    4 . EMC EMISSION TEST                                                  12
      4.1     CONDUCTED EMISSION MEASUREMENT                                12
            4.1.1 POWER LINE CONDUCTED EMISSION LIMITS                      12
            4.1.2 TEST PROCEDURE                                            13
            4.1.3 DEVIATION FROM TEST STANDARD                              13
            4.1.4 TEST SETUP                                                13
      4.2 RADIATED EMISSION MEASUREMENT                                     15
         4.2.1 RADIATED EMISSION LIMITS                                     15
         4.2.2 TEST PROCEDURE                                               16
         4.2.3 DEVIATION FROM TEST STANDARD                                 16
         4.2.4 TEST SETUP                                                   17
         4.2.5 TEST RESULTS (BELOW 30MHZ)                                   19
         4.2.6 TEST RESULTS (BETWEEN 30 – 4000 MHZ)                         20
         4.2.7 DUTY CYCLE                                                   21
    5 . BANDWIDTH TEST                                                     23
            5.1 TEST PROCEDURE                                              23
            5.2 DEVIATION FROM STANDARD                                     23
            5.3 TEST SETUP                                                  23
            5.4 TEST RESULTS                                                24
    6 . TRANSMITTER TIMEOUT                                                25
            6.1 REQUIREMENTS                                                25
    7 . EUT TEST PHOTO                                                     26
     APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS




`


                                         Page 4 of 26           Report No.:NTEK-2015NT0813491F


    1. SUMMARY OF TEST RESULTS

    Test procedures according to the technical standards:
                                    FCC Part15, Subpart C (15.231)
        Standard
                                       Test Item                      Judgment        Remark
         Section
         15.207                  Conducted Emission                     N/A

         15.203                  Antenna Requirement                    Pass

         15.231              Radiated Spurious Emission                 Pass

         15.231                  Occupied Bandwidth                     Pass

         15.231                   Transmitter Timeout                   Pass


    NOTE:
    (1) ” N/A” denotes test is not applicable in this Test Report.




`


                                        Page 5 of 26           Report No.:NTEK-2015NT0813491F


    1.1 TEST FACILITY
       NTEK Testing Technology Co., Ltd
       Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
      Shenzhen P.R. China.
       FCC Registration No.:238937; IC Registration No.:9270A-1
       CNAS Registration No.:L5516
    1.2 MEASUREMENT UNCERTAINTY
      The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
      standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
      approximately 95 %。

                 No.      Item                                  Uncertainty
                 1        Conducted Emission Test               ±1.38dB
                 2        RF power,conducted                    ±0.16dB
                 3        Spurious emissions,conducted          ±0.21dB
                 4        All emissions,radiated(<1G)           ±4.68dB
                 5        All emissions,radiated(>1G)           ±4.89dB
                 6        Temperature                           ±0.5°C
                 7        Humidity                              ±2%




`


                                          Page 6 of 26           Report No.:NTEK-2015NT0813491F


    2. GENERAL INFORMATION

    2.1 GENERAL DESCRIPTION OF EUT



              Equipment                   PIR sensor
              Trade Name                  QUHWA
              Model Name                  QH-9826A-PIR
              Serial Model                N/A
              Model Difference            N/A
                                          The EUT is a PIR sensor

                                          Operation Frequency:    433.92MHz
                                          Modulation Type:        ASK
                                          Number Of Channel       1CH.
              Product Description
                                          Antenna Designation:    PCB Antenna
                                          Antenna Gain(Peak)      1.0 dBi



              Channel List                Refer to below
              Adapter                     N/A
              Battery                     1.5V*3 cell ”AAA” alkaline battery




    Note:
        1. For a more detailed features description, please refer to the manufacturer’s specifications
           or the User's Manual.

        2.
             Table for Filed Antenna
              Ant
                     Brand       Model Name       Antenna Type     Connector Gain (dBi)    NOTE
               .
              1         N/A         N/A           PCB Antenna         N/A       1.0       Antenna




`


                                     Page 7 of 26            Report No.:NTEK-2015NT0813491F


    2.2 DESCRIPTION OF TEST MODES

      To investigate the maximum EMI emission characteristics generates from EUT, the test system
      was pre-scanning tested base on the consideration of following EUT operation mode or test
      configuration mode which possible have effect on EMI emission level. Each of these EUT
      operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

          Pretest Mode                              Description
             Mode 1                                     TX




                                  For Radiated Emission

         Final Test Mode                            Description
             Mode 1                                     TX




`


                                      Page 8 of 26    Report No.:NTEK-2015NT0813491F


    2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED


    Radiated Spurious Emission Test




                                                E-1
                                                EUT




`


                                        Page 9 of 26             Report No.:NTEK-2015NT0813491F


    2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)

    The EUT has been tested as an independent unit together with other necessary accessories or
    support units. The following support units or accessories were used to form a representative test
    configuration during the tests.

    Item     Equipment            Brand            Model/Type No.      Series No.          Note
    E-1      PIR sensor          QUHWA             QH-9826A-PIR           N/A              EUT




    Item       Shielded Type        Ferrite Core        Length                      Note




     Note:
      (1)    The support equipment was authorized by Declaration of Confirmation.
      (2)    For detachable type I/O cable should be specified the length in cm in『Length』column.




`


                                        Page 10 of 26            Report No.:NTEK-2015NT0813491F

    2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS

    Radiation Test equipment
             Kind of                                                 Last       Calibrated Calibratio
    Item                Manufacturer    Type No.    Serial No.
           Equipment                                              calibration     until    n period
           Spectrum                                 MY4510804
      1                   Agilent       E4407B                2015.07.06 2016.07.05          1 year
            Analyzer                                    0
      2 Test Receiver      R&S           ESPI        101318   2015.06.07 2016.06.06          1 year
     3    Bilog Antenna   TESEQ     CBL6111D     31216   2015.07.06 2016.07.05               1 year
           50Ω Coaxial                        620026441
     4                    Anritsu    MP59B               2015.06.07 2016.06.06               1 year
              Switch                               6
            Spectrum
     5                  ADVANTEST     R3132   150900201 2015.06.07 2016.06.06                1 year
             Analyzer
                                    EM-AH-101
     6    Horn Antenna      EM                2011071402 2015.07.06 2016.07.05               1 year
                                       80
     7       Horn Ant   Schwarzbeck BBHA 9170 9170-181 2015.07.06 2016.07.05                 1 year
     8      Amplifier       EM         EM-30180      060538      2014.12.22 2015.12.21       1 year
     9    Loop Antenna      ARA        PLA-1030/B       1029     2015.06.08 2016.06.07       1 year
     10   Power Meter       R&S          NRVS         100696   2015.07.06 2016.07.05         1 year
            Power                                   0395.1619.
     11                     R&S         URV5-Z4                2015.07.06 2016.07.05         1 year
            Sensor                                      05

    Conduction Test equipment
             Kind of     Manufactu                                  Last     Calibrated Calibratio
    Item                                Type No.    Serial No.
           Equipment         rer                                 calibration   until    n period
      1  Test Receiver      R&S          ESCI        101160      2015.06.06 2016.06.05 1 year
     2         LISN          R&S        ENV216       101313      2015.08.24 2016.08.23       1 year
     3         LISN         EMCO         3816/2     00042990 2015.08.24 2016.08.23           1 year
            50Ω Coaxial                             620026441
     4                      Anritsu     MP59B                 2015.06.07 2016.06.06          1 year
              Switch                                    7
     5    Passive Voltage
                             R&S        ESH2-Z3      100196      2015.06.07 2016.06.06       1 year
              Probe
     6    Absorbing clamp    R&S        MOS-21       100423      2015.06.08 2016.06.07       1 year

     2         LISN          R&S        ENV216       101313      2014.08.24 2015.08.23       1 year
     3         LISN         EMCO         3816/2     00042990     2014.08.24 2015.08.23       1 year




`


                                         Page 11 of 26           Report No.:NTEK-2015NT0813491F


    3. ANTENNA REQUIREMENT


    3.1 STANDARD REQUIREMENT

       15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall
        be designed to ensure that no antenna other than that furnished by the responsible party
       shall be used with the device.

    3.2 EUT ANTENNA

    The EUT antenna is permanent attached antenna. It comply with the standard requirement.




`


                                          Page 12 of 26         Report No.:NTEK-2015NT0813491F


    4. EMC EMISSION TEST

    4.1 CONDUCTED EMISSION MEASUREMENT

    4.1.1 POWER LINE CONDUCTED EMISSION Limits               (Frequency Range 150KHz-30MHz)

                                       Class A (dBuV)            Class B (dBuV)
       FREQUENCY (MHz)                                                                   Standard
                                  Quasi-peak       Average   Quasi-peak      Average
             0.15 -0.5                                        66 - 56 *      56 - 46 *   CISPR
             0.50 -5.0                                         56.00          46.00      CISPR
             5.0 -30.0                                         60.00          50.00      CISPR


             0.15 -0.5                                        66 - 56 *      56 - 46 *   LP002.
             0.50 -5.0                                         56.00          46.00      LP002.
            5.0 -30.0                                         60.00      50.00       LP002.
           Note:
             (1) The tighter limit applies at the band edges.
             (2) The limit of " * " marked band means the limitation decreases linearly with the
                 logarithm of the frequency in the range.


    The following table is the setting of the receiver
                 Receiver Parameters                                       Setting
                       Attenuation                                          10 dB
                     Start Frequency                                      0.15 MHz
                     Stop Frequency                                        30 MHz
                      IF Bandwidth                                          9 kHz




`


                                               Page 13 of 26               Report No.:NTEK-2015NT0813491F



    4.1.2 TEST PROCEDURE
     a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
        to the power mains through a line impedance stabilization network (LISN). All other support
        equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
        impedance for the measuring instrument.
     b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
        and forth in the center forming a bundle 30 to 40 cm long.
     c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
        cable may be terminated, if required, using the correct terminating impedance. The overall
        length shall not exceed 1 m.
     d. LISN at least 80 cm from nearest part of EUT chassis.
     e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
    4.1.3 DEVIATION FROM TEST STANDARD
    No deviation


    4.1.4 TEST SETUP
                            V e r tic a l R e fe r e n c e
                            G r o u n d P la n e                                                T e s t R e c e iv e r


                            EUT
           40cm




                                                             80cm
           L IS N




                                                                           H o r iz o n ta l R e f e r e n c e
                                                                            G r o u n d P la n e

             N o te : 1 .S u p p o r t u n its w e r e c o n n e c te d to s e c o n d L IS N .
                      2 .B o t h o f L IS N s ( A M N ) a r e 8 0 c m fr o m E U T a n d a t le a s t 8 0
                         f r o m o th e r u n its a n d o t h e r m e ta l p la n e s




`


                                  Page 14 of 26        Report No.:NTEK-2015NT0813491F


    4.1.5 TEST RESULT

    EUT:             PIR sensor               Model Name. :      QH-9826A-PIR
    Temperature:     26 ℃                     Relative Humidity: 54%
    Pressure:        1010hPa                  Phase :            N/A
    Test Voltage :   N/A                      Test Mode:         N/A




`


                                        Page 15 of 26              Report No.:NTEK-2015NT0813491F


    4.2 RADIATED EMISSION MEASUREMENT

    4.2.1 Radiated Emission Limits     ( FCC 15.209 )
          Frequencies              Field Strength                     Measurement Distance
              (MHz)              (micorvolts/meter)                        (meters)

          0.009~0.490                     2400/F(KHz)                           300
          0.490~1.705                    24000/F(KHz)                           30
           1.705~30.0                           30                              30
              30~88                            100                               3
             88~216                            150                               3
            216~960                            200                               3
           Above 960                           500                               3
          Note:
             (1) The tighter limit applies at the band edges.
             (2) Emission level (dBuV/m)=20log Emission level (uV/m).


         LIMITS OF RADIATED EMISSION MEASUREMENT ( FCC 15.231)
                                            Field Strength of          Field Strength of Unwanted
          Fundamental Frequency
                                            fundamental                Emissions
                       (MHz)
                                            (microvolts/meter)         (microvolts/meter)
                40.66 - 40.70                       2250.00                        225.00
                  70 - 130                          1250.00                        125.00
                  130 - 174                    1,250 to 3,750 **               125 to 375 **
                  174 - 260                         3750.00                        375.00
                  260 - 470                   3,750 to 12,500 **              375 to 1,250 **
                 Above 470                         12500.00                        1250.00
         Notes:
            (1) ** linear interpolations
                [Where F is the frequency in MHz, the formulas for calculating the maximum
                permitted fundamental field strengths are as follows: for the band 130-174 MHz,
                uV/m at 3 meters = 56.81818(F) - 6136.3636; for the band 260-470 MHz, uV/m at 3
                meters = 41.6667(F) - 7083.3333. The maximum permitted unwanted emission level
                is 20 dB below the maximum permitted fundamental level.]
                The limits on the field strength of the spurious emissions in the above table are based
                on the fundamental frequency of the intentional radiator. Spurious emissions shall be
                attenuated to the average (or, alternatively, CISPR quasi-peak) limits shown in this
                table or to the general limits shown in 93 Section 15.209, whichever limit permits a
                higher field strength.




`


                                        Page 16 of 26          Report No.:NTEK-2015NT0813491F


     Spectrum Parameter                        Setting
     Attenuation                               Auto
     Start Frequency                           1000 MHz
     Stop Frequency                            10th carrier harmonic
     RB / VB (emission in restricted band)     1MHz / 1MHz for Peak

     Receiver Parameter                        Setting
     Attenuation                               Auto
     Start ~ Stop Frequency                    9kHz~150kHz / RB 200Hz for QP
     Start ~ Stop Frequency                    150kHz~30MHz / RB 9kHz for QP
     Start ~ Stop Frequency                    30MHz~1000MHz / RB 120kHz for QP

    4.2.2 TEST PROCEDURE
     a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
         For frequencies above 1GHz, any suitable measuring distance may be used.
     b. The EUT was placed on the top of a rotating table 0.8 m for below 1GHz and 1.5m for above
         1GHz the ground at a 3 meter open area test site. The table was rotated 360 degrees to
         determine the position of the highest radiation.
     c. The height of the equipment or of the substitution antenna shall be 0.8 m for below 1GHz and
         1.5m for above 1GHz; the height of the test antenna shall vary between 1 m to 4 m. Both
         horizontal and vertical polarizations of the antenna are set to make the measurement.
     d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
         mode pre-scanning the measurement frequency range. Significant peaks are then marked and
         then Quasi Peak detector mode re-measured.
     e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
         EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
         performed.
      f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
         Note:
         Both horizontal and vertical antenna polarities were tested
         and performed pretest to three orthogonal axis. The worst case emissions were reported

    4.2.3 DEVIATION FROM TEST STANDARD
    No deviation




`


                                  Page 17 of 26          Report No.:NTEK-2015NT0813491F



    4.2.4 TEST SETUP

    (A)Radiated Emission Test-Up Frequency Below 30MHz




    (B)Radiated Emission Test-Up Frequency 30MHz~1GHz




`


                                  Page 18 of 26         Report No.:NTEK-2015NT0813491F

    (C)Radiated Emission Test-Up Frequency Above 1GHz




`


                                        Page 19 of 26             Report No.:NTEK-2015NT0813491F


    4.2.5 TEST RESULTS (BELOW 30MHz)



     EUT:              PIR sensor                      Model Name. :             QH-9826A-PIR
     Temperature:      20 ℃                            Relative Humidtity:       48%
     Pressure:         1010 hPa                        Test Voltage :            N/A
     Test Mode :       TX                              Polarization :            --



             Freq.           Reading             Limit                  Margin          State
             (MHz)           (dBuV/m)          (dBuV/m)                  (dB)            P/F
               --                --               --                      --             N/A
               --                --               --                      --             N/A


    NOTE:

    The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor =40 log (specific distance/test distance)(dB);
    Limit line = specific limits(dBuv) + distance extrapolation factor.




`


                                         Page 20 of 26            Report No.:NTEK-2015NT0813491F


     4.2.6 TEST RESULTS (BETWEEN 30 – 4000 MHZ)

     EUT:              PIR sensor                        Model Name :       QH-9826A-PIR
     Temperature:      20 ℃                              Relative Humidity: 48%
     Pressure:         1010 hPa                          Test Voltage :     DC 4.5V
     Test Mode :       TX                                Polarization :     Horizontal

                        Average          Field          Field
       Frequency                                                     Limit(PK)    Limit(AV)
                         Factor        Strength       Strength
                                                                                               State
                                       dBuV/m         dBuV/m
           MHz             dB                                         dBuV/m       dBuV/m
                                         (PK)           (AV)
          433.92          -6.82          86.82            80.0         100.82       80.82       pass
          867.84          -6.82          44.17            37.35        80.83        60.83       pass
         1301.76          -6.82          48.98            42.16        80.83        60.83       pass
         1735.68          -6.82          35.98            29.16        80.83        60.83       pass


     EUT:              PIR sensor                        Model Name :       QH-9826A-PIR
     Temperature:      20 ℃                              Relative Humidity: 48%
     Pressure:         1010 hPa                          Test Voltage :     DC 4.5V
     Test Mode :       TX                                Polarization :     Vertical

                        Average          Field          Field
       Frequency                                                     Limit(PK)    Limit(AV)
                         Factor        Strength       Strength
                                                                                               State
                                       dBuV/m         dBuV/m
           MHz             dB                                         dBuV/m       dBuV/m
                                         (PK)           (AV)
          433.92          -6.82          80.25            73.43        100.82       80.82       pass
          867.84          -6.82          46.16            39.34        80.83        60.83       pass
         1301.76          -6.82          42.09            35.27        80.83        60.83       pass
         1735.68          -6.82          33.82            27.00        80.83        60.83       pass


    Note: 1. EUT Pre-scan X/Y/Z orientation, only worst case is presented in the report(Z orientation).
           2. *Calculate Average value based on Duty Cycle correction factor:
            Duty Cycle=Ton/(Ton+Toff)= (1.133ms×10+0.4 ms×8)/31.47ms =0.45=45%
            Duty Cycle factor=20lg(Duty Cycle)=20lg(0.45)= -6.82dB
            Average=Peak+ Duty Cycle factor
            2. Pulse Desensitization Correction Factor
            Pulse Width(PW)=14.53ms
            2/PW=2/14.4027ms=0.13kHz
            RBW(100kHz)>2/PW (0.13KHz)
            Therefore PDCF is not needed




`


                                          Page 21 of 26           Report No.:NTEK-2015NT0813491F



     4.2.7 Duty Cycle
    The duty cycle is simply the on time divided by the period:
    The duration of one cycle = 31.47ms
    Effective period of the cycle = 1.133ms×10+0.4ms×8=14.53ms
    Duty Cycle = 13.653ms/31.47ms =0.45

                                        The duration of one cycle




`


    Page 22 of 26   Report No.:NTEK-2015NT0813491F




`


                                       Page 23 of 26           Report No.:NTEK-2015NT0813491F


    5. BANDWIDTH TEST


    5.1 TEST PROCEDURE

    The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
    operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
    emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
    points 20 dB down from the modulated carrier.
    Limit: 433.92MHz*0.25%=1084.8KHz


    5.2 DEVIATION FROM STANDARD

    No deviation.

    5.3 TEST SETUP




`


                                    Page 24 of 26          Report No.:NTEK-2015NT0813491F


    5.4 TEST RESULTS

    EUT:           PIR sensor                   Model Name :       QH-9826A-PIR
    Temperature:   26 ℃                         Relative Humidity: 53%
    Pressure:      1020 hPa                     Test Power :       DC 4.5V
    Test Mode :    TX CH 1


                                Frequency           20 dBc Bandwidth         Limit
        Test Channel
                                  (MHz)                  (kHz)               (kHz)
           CH01                   433.92                178.461             1084.8




`


                                        Page 25 of 26            Report No.:NTEK-2015NT0813491F


    6. TRANSMITTER TIMEOUT

    6.1 REQUIREMENTS


     1 A manually operated transmitter shall employ a switch that will automatically deactivate the
       transmitter within not more than 5 seconds of being released.
       Result: The EUT does not have a automatically activated transmitter .

     2 A transmitter activated automatically shall cease transmission within 5 seconds after
       activation.
       Result: The EUT has a automatically activated transmitter, please refer to below detail data.

     3 Periodic transmissions at regular predetermined intervals are not permitted. However, polling
       or supervision transmissions, including data, to determine system integrity of transmitters used
       in security or safety applications are allowed if the total duration of transmissions does not
       exceed more than two seconds per hour for each transmitter. There is no limit on the number
       of individual transmissions, provided the total transmission time does not exceed two seconds
       per hour
       Result:The EUT does not employ periodic transmission.
     4 Intentional radiators which are employed for radio control purposes during emergencies
       involving fire, security, and safety of life, when activated to signal an alarm, may operate
       during the pendency of the alarm condition.
       Result:The section is not applicable to EUT.

                                                Test data




            THE DURATION OF
                                                  LIMIT                      RESULT
           EACH TRANSMISSION

                     1.6s                          <5s                         PASS




`


                            Page 26 of 26     Report No.:NTEK-2015NT0813491F


    7. EUT TEST PHOTO

                        Radiated Measurement Photos




`



Document Created: 2015-09-22 08:58:00
Document Modified: 2015-09-22 08:58:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC