EMC report

FCC ID: 2AAPKDC-0553

Test Report

Download: PDF
FCCID_2495280

EMC TEST
REPORT
Report No.: 14070653-FCC-E1
Supersede Report No.: N/A
Applicant              SHENZHEN KINGSUN ENTERPRISES Co.,Ltd
Product Name           Bluetooth Remote shutter speaker
Model No.              DC-0553
Test Standard          FCC Part 15 Subpart B Class B:2014, ANSI C63.4: 2009
Test Date              December 11, 2014
Issue Date             December 22, 2014
Test Result               Pass       Fail
Equipment complied with the specification
Equipment did not comply with the specification




            LiLi Xia                          Alex Liu
       Test Engineer                        Checked By

                         This test report may be reproduced in full only
    Test result presented in this test report is applicable to the tested sample only


                                            Issued by:
                        SIEMIC (SHENZHEN-CHINA) LABORATORIES
                       Zone A, Floor 1, Building 2 Wan Ye Long Technology Park
       South Side of Zhoushi Road, Bao’ an District, Shenzhen, Guangdong China 518108
                   Phone: +86 0755 2601 4629801 Email: China@siemic.com.cn


                                          Test Report       14070653-FCC-E1
                                          Page              2 of 24




                             Laboratories Introduction

SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one
of the leading independent testing and certification facilities providing customers with one-stop
shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance
management throughout a project. Our extensive experience with China, Asia Pacific, North
America, European, and International compliance requirements, assures the fastest, most cost
effective way to attain regulatory compliance for the global markets.


                       Accreditations for Conformity Assessment
            Country/Region                                            Scope
                   USA                            EMC, RF/Wireless, SAR, Telecom
                 Canada                           EMC, RF/Wireless, SAR, Telecom
                  Taiwan                           EMC, RF, Telecom, SAR, Safety
               Hong Kong                                RF/Wireless, SAR, Telecom
                 Australia                         EMC, RF, Telecom, SAR, Safety
                  Korea                          EMI, EMS, RF, SAR, Telecom, Safety
                  Japan                            EMI, RF/Wireless, SAR, Telecom
                Singapore                                EMC, RF, SAR, Telecom
                  Europe                           EMC, RF, SAR, Telecom, Safety


                                      Test Report   14070653-FCC-E1
                                      Page          3 of 24




This page has been left blank intentionally.


                                                                     Test Report               14070653-FCC-E1
                                                                     Page                      4 of 24




CONTENTS

1.     REPORT REVISION HISTORY ............................................................................................................................ 5

2.     CUSTOMER INFORMATION ................................................................................................................................ 5

3.     TEST SITE INFORMATION ................................................................................................................................... 5

4.     EQUIPMENT UNDER TEST (EUT) INFORMATION ......................................................................................... 6

5.     TEST SUMMARY .................................................................................................................................................... 7

6.     MEASUREMENTS, EXAMINATION AND DERIVED RESULTS ..................................................................... 8

6.1 AC POWER LINE CONDUCTED EMISSIONS ..................................................................................................... 8

6.2 RADIATED EMISSIONS ......................................................................................................................................... 12

ANNEX A. TEST INSTRUMENT................................................................................................................................. 15

ANNEX B. EUT AND TEST SETUP PHOTOGRAPHS ........................................................................................... 16

ANNEX C. TEST SETUP AND SUPPORTING EQUIPMENT................................................................................ 20

ANNEX D. USER MANUAL / BLOCK DIAGRAM / SCHEMATICS / PARTLIST .................................................. 23

ANNEX E. DECLARATION OF SIMILARITY ............................................................................................................ 24


                                             Test Report    14070653-FCC-E1
                                             Page           5 of 24




1. Report Revision History

         Report No.              Report Version               Description                Issue Date
     14070653-FCC-E1                  NONE                      Original             December 22, 2014




2. Customer information


Applicant Name          SHENZHEN KINGSUN ENTERPRISES Co.,Ltd
Applicant Add           25/F, CEC Information Building, Xinwen Rd., Shenzhen, Guangdong, China
Manufacturer            Shenzhen E-Ran Technology Co.,Ltd.
Manufacturer Add        6 Floor, Block A Xiangjiang Industrial Park, Songbai Road, Shiyan Town, Baoan
                        District, Shenzhen



3. Test site information
 Lab performing tests       SIEMIC (Shenzhen-China) LABORATORIES
                            Zone A, Floor 1, Building 2 Wan Ye Long Technology Park
 Lab Address                South Side of Zhoushi Road, Bao’ an District, Shenzhen, Guangdong
                            China 518108
 FCC Test Site No.          718246
 IC Test Site No.           4842E-1
 Test Software              Labview of SIEMIC version 2.0


                                           Test Report   14070653-FCC-E1
                                           Page          6 of 24




 4. Equipment under Test (EUT) Information
Description of EUT:             Bluetooth Remote shutter speaker



Main Model:                     DC-0553


Serial Model:                   ER-BT30


Date EUT received:              December 02, 2014


Test Date(s):                   December 11, 2014


Equipment Category:             JBP


Antenna Gain:                   Bluetooth: 0.9 dBi


Type of Modulation:             Bluetooth: GFSK, π /4DQPSK, 8DPSK



RF Operating Frequency (ies):   Bluetooth: 2402-2480 MHz



Number of Channels:             Bluetooth: 79CH


Port:                           USB Port


                                Battery:
                                Model: 502026
Input Power:
                                Spec: 3.7V 180mAh
                                USB Power Supply: 5V


Trade Name :                    N/A


GPRS/EGPRS Multi-slot class     N/A


FCC ID:                         2AAPKDC-0553


                                          Test Report     14070653-FCC-E1
                                          Page            7 of 24




 5. Test Summary

The product was tested in accordance with the following specifications.
All testing has been performed according to below product classification:


         FCC Rules                               Description of Test                    Result
 §15.107; ANSI C63.4: 2009     AC Power Line Conducted Emissions                     Compliance
 §15.109; ANSI C63.4: 2009     Radiated Emissions                                    Compliance


Measurement Uncertainty

                                            Emissions
         Test Item                                Description                       Uncertainty
                              Confidence level of approximately 95% (in the case
  Band Edge and Radiated
                                where distributions are normal), with a coverage   +5.6dB/-4.5dB
    Spurious Emissions
                                  factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)


                                             Test Report           14070653-FCC-E1
                                             Page                  8 of 24




 6. Measurements, Examination And Derived Results

6.1 AC Power Line Conducted Emissions

Temperature                                                19oC
Relative Humidity                                          59%
Atmospheric Pressure                                       1009mbar
Test date :                                                December 11, 2014
Tested By :                                                LiLi Xia


Requirement(s):

Spec              Item    Requirement                                                            Applicable
                          For Low-power radio-frequency devices that is designed to be
                          connected to the public utility (AC) power line, the radio frequency
                          voltage that is conducted back onto the AC power line on any
                          frequency or frequencies, within the band 150 kHz to 30 MHz, shall
                          not exceed the limits in the following table, as measured using a 50
47CFR§15.                 [mu] H/50 ohms line impedance stabilization network (LISN). The
                    a)
     107                  lower limit applies at the boundary between the frequencies ranges.
                            Frequency ranges                          Limit (dBµV)
                                  (MHz)                      QP                      Average
                                0.15 ~ 0.5                 66 – 56                   56 – 46
                                  0.5 ~ 5                     56                       46
                                  5 ~ 30                      60                       50




Test Setup




                  1. The EUT and supporting equipment were set up in accordance with the requirements of
                     the standard on top of a 1.5m x 1m x 0.8m high, non-metallic table.
 Procedure
                  2. The power supply for the EUT was fed through a 50W/50mH EUT LISN, connected to
                     filtered mains.


                                          Test Report     14070653-FCC-E1
                                          Page            9 of 24


            3. The RF OUT of the EUT LISN was connected to the EMI test receiver via a low-loss
                  coaxial cable.
            4. All other supporting equipment were powered separately from another main supply.
            5. The EUT was switched on and allowed to warm up to its normal operating condition.
            6. A scan was made on the NEUTRAL line (for AC mains) or Earth line (for DC power)
                  over the required frequency range using an EMI test receiver.
            7. High peaks, relative to the limit line, The EMI test receiver was then tuned to the
                  selected frequencies and the necessary measurements made with a receiver bandwidth
                  setting of 10 kHz.
            8. Step 7 was then repeated for the LIVE line (for AC mains) or DC line (for DC power).

  Remark

   Result      Pass                    Fail



Test Data   Yes                          N/A

Test Plot   Yes (See below)              N/A


                                                        Test Report      1orosss—rec—e1
                                                        Page             100r24



[Test Mode:                    Transmitting Mode


                                        Peak Detector             Quast Peak Limi
                                        Average Detector          Average timit
                      se
                      ao—
     dentituaeC aun




                      1n0—

                        o is                            1 ho                              fo‘mo         slo
                                                               Tremeney Oto

     Tost Data
                                            Phase Line Plot at 120Vac, 60Hz

     Frequency                  :::z'       Umit         Margin       Averge      Limkk    Margin   Factors
             (Wia               gBm       (Waao           B           (Bun        t          «B      B

                  ara           «074       seo           —1s2s        s1«         4800     1560     1076
                  326           3502       seo           2018         252         4800     2077     1067
                  cce           40.38      seo           —1se2        sns         4800     1562     101
                  446           s260       seo           2331         2200        4800     2ase     10.00
                  azo           a7.ge      seo           —18e4        2572        4800     1928     109«
                  422           ce.or      seo           —im0e        2re7        4800     1862     105


   .
SsIEMIC                                    Texremn          romeasrecs
cwomresmea.comncar                          Page            11 or2e



[Test Mode:          Transmitting Mode


                              PeakcDetector           Quasi Peak Limit
                              Average Detector        Average Limit
         se
         so
         me—
         so 0



       fmo
        mo—
        100—

              o is                         1 ho                                 fo‘mo        slo
                                                   Tremeey Oto

     Tost Data
                                Phase Neutral Plot at 120Vac, 60Hz

     Frequensy        °425       Limik      Margn      Average           Limk     Margh   Factors
       (Wio)         ;;:C)      ad           @3         ad            CBm          (B)     @3
        a5o           as.so      seo        2041        2468          4800       2132     |_i0.m
        a2e           ce.2r      seoo       1773        2624          4800       —1a7e    |_10.7
        202           caee       seoo       2217        2249          4800       —2a51    10.63
        ais           40.19      seo        2521        20.00         seco       —as i    12.40
        ace           anre       seo        2427        2122          «800       2478     |_10.81
        130           c0.52      seo        2548        19.70         4800       —2s30    |_10.32


                                                 Test Report          14070653-FCC-E1
                                                 Page                 12 of 24




6.2 Radiated Emissions

Temperature                                                    19oC
Relative Humidity                                              59%
Atmospheric Pressure                                           1009mbar
Test date :                                                    December 11, 2014
Tested By :                                                    LiLi Xia


Requirement(s):

Spec              Item       Requirement                                                              Applicable
                             Except higher limit as specified elsewhere in other section, the
                             emissions from the low-power radio-frequency devices shall not
                             exceed the field strength levels specified in the following table and
                             the level of any unwanted emissions shall not exceed the level of
                             the fundamental emission. The tighter limit applies at the band
47CFR§15.
                       a)    edges
   107(d)                          Frequency range (MHz)                   Field Strength (µV/m)
                                           30 – 88                                 100
                                          88 – 216                                 150
                                           216 960                                 200
                                          Above 960                                500




Test Setup




                  1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                  2.        The test was carried out at the selected frequency points obtained from the EUT
                            characterization. Maximization of the emissions, was carried out by rotating the EUT,
Procedure
                            changing the antenna polarization, and adjusting the antenna height in the following
                            manner:
                            a.       Vertical or horizontal polarization (whichever gave the higher emission level


                                       Test Report      14070653-FCC-E1
                                       Page             13 of 24


                           over a full rotation of the EUT) was chosen.
                    b.     The EUT was then rotated to the direction that gave the maximum
                           emission.
                   c.      Finally, the antenna height was adjusted to the height that gave the maximum
                           emission.
            3.     The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
                   120 kHz for Quasiy Peak detection at frequency below 1GHz.
            4.     The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video
                   bandwidth is 3MHz with Peak detection for Peak measurement at frequency above
                   1GHz.
                    The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
                    bandwidth with Peak detection for Average Measurement as below at frequency
                    above 1GHz.
                    ■ 1 kHz (Duty cycle < 98%) □ 10 Hz (Duty cycle > 98%)
            5.     Steps 2 and 3 were repeated for the next frequency point, until all selected frequency
                   points were measured.

  Remark

   Result        Pass                Fail



Test Data   Yes                        N/A

Test Plot   Yes (See below)            N/A


              9
SIEMIC
aom nswescmoras
                                                      TestReport        rermssrooe
                                                      Pase              rem


[Fest Made:                       Transmitting Mode



                                                       (Below 1GHz)
                                                      Preaktetor
                                                      cussireak ie
 Auplitude (dBut/a)




                      10.0
                       o. 0                                                                               (
                         s0.0                     100. 0                                               1000.
                                                           Enemience        O

                      Tost Data
                                           Vertical & Horlzontal Polarty Plot @3m

                       rmunny| Cl )| Pooty maght facom                                   lint   Nagh
                        #5D       cowim)               en              en       «n      cowm|    am
                       2rees       «218      |_0.00        h       12000        —7.01   4800    295
                       2e809       seo1     sso.0          H       12200        «713    4800    —6.99
                       2esor       40.ce    sso.0          h       14800        —6.92   4800    —so1
                       2ssea       sssr     140.00         H       13800        —7.49   48.00   10.43
                       2aist       sasr      300           h       18400        —7s2    4800    1243
                       aseos       sass     a7.0           H       10000        —7.31   48.00   1167
Note: The above 1GHz frequency was pre—scanned and the result which was 2008 lower than the
fimit Ine per 15.10 was not recorded


                                    Test Report     14070653-FCC-E1
                                    Page            15 of 24




Annex A. TEST INSTRUMENT


       Instrument         Model              Serial #           Cal Date    Cal Due    In use

AC Line Conducted Emissions
   EMI test receiver     ESCS30            8471241027          09/18/2014 09/17/2015
   Line Impedance
                         LI-125A             191106            09/26/2014 09/25/2015
 Stabilization Network
   Line Impedance
                         LI-125A             191107            09/26/2014 09/25/2015
 Stabilization Network
         LISN            ISN T800            34373             09/26/2014 09/25/2015
   Transient Limiter     LIT-153             531118            09/02/2014 09/01/2015
Radiated Emissions
   EMI test receiver      ESL6               100262            09/18/2014 09/17/2015
OPT 010 AMPLIFIER
                          8447E            2727A02430          09/02/2014 09/01/2015
   (0.1-1300MHz)
Microwave Preamplifier
                         PAM-118             443008            09/02/2014 09/01/2015
    (0.5~18GHz)
    Bilog Antenna
                           JB6              A110712            09/22/2014 09/21/2015
   (30MHz~6GHz)
  Double Ridge Horn
                         AH-118              71259             09/25/2014 09/24/2015
       Antenna


                                        Test Report   14070653-FCC-E1
                                        Page          16 of 24




Annex B. EUT And Test Setup Photographs

Annex B.i.      Photograph: EUT External Photo




             Whole Package - Top View                            EUT All Colors - Top View




                 EUT - Front View                                    EUT - Rear View


                  Test Report   14070653-FCC-E1
                  Page          17 of 24




EUT - Top View                             EUT - Bottom View




EUT - Left View                            EUT - Right View


                                            Test Report   14070653-FCC-E1
                                            Page          18 of 24




Annex B.ii.    Photograph: EUT Internal Photo




               Cover Off - Top View                                    Battery - Top View




              Mainborad - Front View                                 Mainborad - Rear View

                                      Antenna View


                                         Test Report     14070653-FCC-E1
                                         Page            19 of 24




Annex B.iii. Photograph: Test Setup Photo




    Conducted Emissions Test Setup Front View           Conducted Emissions Test Setup Side View




                                                       Radiated Spurious Emissions Test Setup Above
Radiated Spurious Emissions Test Setup Below 1GHz
                                                                           1GHz


                                    Test Report      14070653-FCC-E1
                                    Page             20 of 24




Annex C. TEST SETUP AND SUPPORTING EQUIPMENT

Annex C.ii.     TEST SET UP BLOCK


Block Configuration Diagram for Conducted Emissions



    LISN 1
    V=120V AC
    F=60Hz




                  Adapter    EUT            Laptop




                                                                        Test Table


                                                                       80cm above
                                                                       ground plane


                                   Test Report     14070653-FCC-E1
                                   Page            21 of 24




Block Configuration Diagram for Radiated Emissions




                                                              Laptop     Adapter
                                             EUT




                                                                        Test Table


                                                                       80cm above
                                                                       ground plane




                                                      d=3meter




                                     Receiving Antenna


                                            Test Report      14070653-FCC-E1
                                            Page             22 of 24




Annex C. iI. SUPPORTING EQUIPMENT DESCRIPTION

The following is a description of supporting equipment and details of cables used with the EUT.


                              Equipment                                         Calibration       Calibration
   Manufacturer                                              Model
                             Description                                            Date          Due Date
      Lenovo                Lenovo Laptop                 E40& 0579A52              N/A              N/A


                             Test Report   14070653-FCC-E1
                             Page          23 of 24




Annex D. User Manual / Block Diagram / Schematics / Partlist


Please see Attachment


                       Test Report   14070653-FCC-E1
                       Page          24 of 24




Annex E. DECLARATION OF SIMILARITY


N/A



Document Created: 2019-06-06 02:58:32
Document Modified: 2019-06-06 02:58:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC