14_AW-ROBO-ROLL TestRpt, r1

FCC ID: 2AANZROBO

Test Report

Download: PDF
FCCID_4035570

                                          Page 1 of 31            Report No.: HK1810121272E




                         FCC TEST REPORT
                       FCC PART 15 SUBPART C 15.249




                                       Test report
                                       On Behalf of
                                    DGL Group LTD.
                                            For
                                     ROBO ROLL-R


                   Model No.: AW-ROBO-ROLL, AW-ROBO-SK8R


                                 FCC ID: 2AANZROBO




Prepared for :    DGL Group LTD.
                  195 Raritan Center Parkway Edison, New Jersey United States 08837




 Prepared By :    Shenzhen HUAK Testing Technology Co., Ltd.
                  1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai
                  Street, Bao'an District, Shenzhen City, China




Date of Test:       Sep. 26, 2018 ~ Oct. 12, 2018
Date of Report:     Oct. 12, 2018
Report Number:      HK1810121272E


                                                                          Page 2 of 31               Report No.: HK1810121272E

                                                TEST RESULT CERTIFICATION

Applicant’s name ....................DGL
                                     :   Group LTD.
Address ....................................195
                                             : Raritan Center Parkway Edison, New Jersey United States 08837
Manufacture's Name ..............DGL
                                 :   Group LTD.

Address ....................................195
                                            : Raritan Center Parkway Edison, New Jersey United States 08837

Product description
Trade Mark:                                    N/A
Product name ...........................ROBO
                                        :    ROLL-R
Model and/or type reference ..AW-ROBO-ROLL
                              :
Series Models                                  AW-ROBO-SK8R
Declaration of Difference                      All the same except for the model name and appearance.
                                          FCC Rules and Regulations Part 15 Subpart C Section 15.249
Standards ................................ :
                                          ANSI C63.10: 2013
This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen
HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material.
Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for
damages resulting from the reader's interpretation of the reproduced material due to its placement and
context.
Date of Test ................................................ :
Date (s) of performance of tests ................. :                   Sep. 26, 2018 ~ Oct. 12, 2018
Date of Issue............................................... :         Oct. 12, 2018
Test Result................................................... :       Pass



                                Testing Engineer                   :


                                                                                       (Gary Qian)

                                Technical Manager                  :

                                                                                       (Eden Hu)


                                Authorized Signatory :


                                                                                   (Jason Zhou)


                                     Page 3 of 31   Report No.: HK1810121272E



                          Table of Contents                         Page


1 . TEST SUMMARY                                                           4

2 . GENERAL INFORMATION                                                    5
   2.1 GENERAL DESCRIPTION OF EUT                                          5
   2.2 OPERATION OF EUT DURING TESTING                                     6
   2.3 DESCRIPTION OF TEST SETUP                                           6
   2.4 MEASUREMENT INSTRUMENTS LIST                                        7

3. RADIATED EMISSION                                                       8
   3.1. MEASUREMENT PROCEDURE                                              8
   3.2. TEST SETUP                                                      10
   3.3. TEST RESULT                                                     11

4. BAND EDGE EMISSION                                                   17
   4.1. MEASUREMENT PROCEDURE                                           17
   4.2 TEST SETUP                                                       17
   4.3 RADIATED TEST RESULT                                             17

5. BANDWIDTH                                                            22
   5.1. MEASUREMENT PROCEDURE                                           22
   5.2. TEST SETUP                                                      22
   5.3. TEST RESULT                                                     23

6. PHOTOGRAPH OF TEST                                                   25

7. PHOTOGRAPH OF EUT                                                    26


                                               Page 4 of 31            Report No.: HK1810121272E


1. TEST SUMMARY

1.1 TEST PROCEDURES AND RESULTS

     FCC RULES                       DESCRIPTION OF TEST                              RESULT
    §15.249&15.209                        Radiated Emission                       Compliant
    §15.249&15.209                     Band Edges Emission                        Compliant
        §15.215                            20dB bandwidth                         Compliant
        §15.207                         Conducted Emission                             N/A




1.2 TEST FACILITY

 Test Firm             :   Shenzhen HUAK Testing Technology Co., Ltd.


 Address               :   1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park,
                           Fuhai Street, Bao'an District, Shenzhen City, China
 Designation Number:   :   CN1229
 Test Firm Registration Number : 616276




1.3 MEASUREMENT UNCERTAINTY

  Measurement Uncertainty
  Conducted Emission Expanded Uncertainty                          =    2.23dB, k=2
  Radiated emission expanded uncertainty(9kHz-30MHz)               =    3.08dB, k=2
  Radiated emission expanded uncertainty(30MHz-1000MHz)            =    4.42dB, k=2
  Radiated emission expanded uncertainty(Above 1GHz)               =    4.06dB, k=2


                                        Page 5 of 31   Report No.: HK1810121272E



 2. GENERAL INFORMATION

 2.1 GENERAL DESCRIPTION OF EUT
Operation Frequency   2407-2477MHz
Field Strength(3m)    79.05dBuV/m(Average)@3m
Modulation            GFSK
Number of channels    3
Test Channels         2407MHz, 2447MHz, 2477MHz
Hardware Version      FL-001 T-2.4G 2016.1.3
Software Version      V2.0
Antenna Designation   Fixed antenna
Antenna Gain          0dBi
Power Supply          DC3V by battery


                                                 Page 6 of 31           Report No.: HK1810121272E


 2.2 OPERATION OF EUT DURING TESTING

         NO.                                      TEST MODE DESCRIPTION
          1                                             Low channel TX
          2                                            Middle channel TX
          3                                             High channel TX
Note:
1. Only the data of the worst case recorded in the test report.
2. For Radiated Emission, 3axis were chosen for testing for each applicable mode.



 2.3 DESCRIPTION OF TEST SETUP



                  Operation of EUT during Radiation and Above1GHz Radiation testing:




                                                EUT


                                             Page 7 of 31           Report No.: HK1810121272E


2.4 MEASUREMENT INSTRUMENTS LIST

                                                                                           Cal.
Item      Equipment         Manufacturer     Model No.      Serial No.      Last Cal.
                                                                                          Interval
            L.I.S.N.
 1.     Artificial Mains        R&S           ENV216        HKE-002       Dec. 28, 2017   1 Year
           Network
 2.        Receiver             R&S            ESCI 7       HKE-010       Dec. 28, 2017   1 Year
         RF automatic
 3.                           Tonscend        JS0806-2      HKE-060       Dec. 28, 2017   1 Year
          control unit
 4.    Spectrum analyzer        R&S            FSP40        HKE-025       Dec. 28, 2017   1 Year
 5.    Spectrum analyzer       Agilent        N9020A        HKE-048       Dec. 28, 2017   1 Year
 6.       Preamplifier      Schwarzbeck      BBV 9743       HKE-006       Dec. 28, 2017   1 Year
 7.    EMI Test Receiver   Rohde & Schwarz     ESCI 7       HKE-010       Dec. 28, 2017   1 Year
       Bilog Broadband
 8.                         Schwarzbeck      VULB9163       HKE-012       Dec. 28, 2017   1 Year
           Antenna
                                             FMZB 1519
 9.      Loop Antenna        Schwarzbeck                    HKE-014
                                                             FMZB 1519 Dec.012
                                                                            28, 2017
                                                                                May 11,12016
                                                                                         Year 1 Year
                                                 B
10.      Horn Antenna       Schewarzbeck       9120D        HKE-013       Dec. 28, 2017   1 Year
                                             EMC051845
11.      Pre-amplifier          EMCI                        HKE-015       Dec. 28, 2017   1 Year
                                                SE
12.      Pre-amplifier         Agilent        83051A        HKE-016       Dec. 28, 2017   1 Year
       EMI Test Software                     JS1120-B
13.                           Tonscend                      HKE-083       Dec. 28, 2017    N/A
           EZ-EMC                             Version
14.     Shielded room        Shiel Hong        4*3*3        HKE-039       Dec. 28, 2017   3 Year


                                                 Page 8 of 31            Report No.: HK1810121272E


3. RADIATED EMISSION

3.1. MEASUREMENT PROCEDURE
 1. The EUT was placed on the top of the turntable 0.8 or 1.5 meter above ground. The phase center of
    the receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far
    away from the turntable.
 2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
    the position of the highest radiation.
 3. The height of the broadband receiving antenna was varied between one meter and four meters above
    ground to find the maximum emissions field strength of both horizontal and vertical polarization.
 4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable
    was rotated (from 0 degree to 360 degrees) to find the maximum reading.
 5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
    under Maximum Hold Mode.
 6. For emissions above 1GHz, use 1MHz VBW and RBW for peak reading. Then 1MHz RBW and 10Hz
    VBW for average reading in spectrum analyzer. Place the measurement antenna away from each area
    of the EUT determined to be a source of emissions at the specified measurement distance, while
    keeping the measurement antenna aimed at the source of emissions at each frequency of significant
    emissions, with polarization oriented for maximum response. The measurement antenna may have to
    be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed
    at the emission source for receiving the maximum signal. The final measurement antenna elevation
    shall be that which maximizes the emissions. The measurement antenna elevation for maximum
    emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference
    ground plane.
 7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and
    pulsed operation is employed, the measurement field strength shall be determined by averaging over
    one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1
    seconds. As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases
    where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the
    average absolute voltage during a 0.1 second interval during which the field strength is at its maximum
    values.
 8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
    testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
    have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
 9. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit
    (that means the emissions level in peak mode also complies with the limit in average mode), then
    testing will be stopped and peak values of EUT will be reported, otherwise, the emissions will be
    measured in average mode again and reported.
 10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
    recorded data should be QP measured by receiver. High - Low scan is not required in this case.


                                                    Page 9 of 31               Report No.: HK1810121272E

The following table is the setting of spectrum analyzer and receiver.
                Spectrum Parameter                                                  Setting

                Start ~Stop Frequency                              9KHz~150KHz/RBW 200H2z for QP

                Start ~Stop Frequency                              150KHz~30MHz/RBW 9KHz for QP

                Start ~Stop Frequency                            30MHz~1000MHz/RBW 120KHz for QP
                                                                              1GHz~26.5GHz
                Start ~Stop Frequency
                                                            1.5MHz/5MHz for Peak, 1.5MHz/10Hz for Average


                Receiver    Parameter                                               Setting

                Start ~Stop Frequency                              9KHz~150KHz/RBW 200H2z for QP

                Start ~Stop Frequency                              150KHz~30MHz/RBW 9KHz for QP

                Start ~Stop Frequency                            30MHz~1000MHz/RBW 120KHz for QP


Test limit for Standard FCC15.249
Fundamental Frequency                 Field Strength of Fundamental           Field Strength of Harmonics
                                      {millivolts/meter)                      {microvolts/meter)
900—928MHz                            50                                      500
2400—2483.5MHz                        50                                      500
5725—5875MHz                          50                                      500
24.0—24.25GHz                         250                                     2500

Test limit for Standard FCC 15.209
Frequency                   Distance                                       Field Strengths Limit
(MHz)                       Meters                         1 V/m                        dB(pV)/m
0.009 ~ 0.490               300                            2400/F(kHz)
0.490 ~ 1.705               30                             24000/F(kHz)
1.705 ~ 30                  30                             30
30 ~ 88                     3                              100                          40.0
88 ~ 216                    3                              150                          43.5
216 ~ 960                   3                              200                          46.0
960 ~ 1000                  3                              500                          54.0
Above 1000                  3                              Other:74.0     dB(uV)/m      (Peak)   54.0   dB(uV)/im
                                                           (Average)
Remark:      (1) Emission level dBu V =20 log Emission level u V/m
             (2) The smaller limit shall apply at the cross point between two frequency bands.
             (3) Distance is the distance in meters between the measuring instrument, antenna and the
                 closest point of any part of the device or system.


                                       Page 10 of 31         Report No.: HK1810121272E

3.2. TEST SETUP
                  Radiated Emission Test-Setup Frequency Below 30MHz




                  RADIATED EMISSION TEST SETUP 30MHz-1000MHz




                  RADIATED EMISSION TEST SETUP ABOVE 1000MHz


                                          Page 11 of 31           Report No.: HK1810121272E

3.3. TEST RESULT
                           RADIATED EMISSION BELOW 30MHz
         No emission found between lowest internal used/generated frequencies to 30MHz.
                      RADIATED EMISSION BELOW 1GHZ-Horizontal


                                                 Page 12 of 31             Report No.: HK1810121272E

                             RADIATED EMISSION BELOW 1GHZ-Vertical




RESULT: PASS
Note: 1. Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      2. The “Factor” value can be calculated automatically by software of measurement system.
     3. The mode 1 is the worst case, and only the data of the worst case recorded in this test report.


                                                Page 13 of 31                Report No.: HK1810121272E

                                  RADIATED EMISSION ABOVE 1GHZ
                                 Field strength of fundamental emission

EUT:               ROBO ROLL-R                        Model Name.:              AW-ROBO-ROLL
Temperature:       20 ℃                               Relative Humidtity:       48%
Pressure:          1010 hPa                           Test Voltage:             DC3V
Test Mode :        Mode 1/2/3                         Polarization :            Horizontal

   Frequency     Meter Reading        Factor    Emission Level     Limits        Margin
                                                                                             Value Type
     (MHz)          (dBμV)             (dB)       (dBμV/m)       (dBμV/m)         (dB)
    2407.015         91.54            -9.63         81.91              114        -32.09       peak
    2407.015         87.37            -9.63         77.74              94         -16.26       AVG
    2447.014         91.95            -9.63         82.32              114        -31.68       peak
    2447.014         87.95            -9.63         78.32              94         -15.68       AVG
    2477.011         92.75            -9.63         83.12              114        -30.88       peak
    2477.011         88.68            -9.63         79.05              94         -14.95        AVG
 Remark:
 Factor = Antenna Factor + Cable Loss – Pre-amplifier.


EUT:               ROBO ROLL-R                        Model Name. :             AW-ROBO-ROLL
Temperature:       20 ℃                               Relative Humidtity:       48%
Pressure:          1010 hPa                           Test Voltage :            DC3V
Test Mode :        Mode 1/2/3                         Polarization :            Vertical

   Frequency     Meter Reading        Factor    Emission Level     Limits        Margin
                                                                                             Value Type
     (MHz)          (dBμV)             (dB)       (dBμV/m)       (dBμV/m)         (dB)
    2407.015         90.36            -9.63         80.73              114        -33.27       peak
    2407.015         86.41            -9.63         76.78              94         -17.22       AVG
    2447.014         91.04            -9.63         81.41              114        -32.59       peak
    2447.014         87.12            -9.63         77.49              94         -16.51       AVG
    2477.011         91.39            -9.63         81.76              114        -32.24       peak
    2477.011         87.68            -9.63         78.05              94         -15.95       AVG
 Remark:
 Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                                Page 14 of 31               Report No.: HK1810121272E

                                 Field strength of spurious emission

EUT:              ROBO ROLL-R                         Model Name.:             AW-ROBO-ROLL
Temperature:      20 ℃                                Relative Humidtity:      48%
Pressure:         1010 hPa                            Test Voltage:            DC3V
Test Mode :       Mode 1                              Polarization :           Horizontal

    Frequency    Meter Reading      Factor      Emission Level     Limits       Margin
                                                                                            Value Type
      (MHz)         (dBμV)           (dB)         (dBμV/m)       (dBμV/m)        (dB)
     4814.03         42.16           3.76           45.92              74       -28.08        peak
     4814.03         39.88           3.76           43.64              54       -10.36        AVG
    7221.045         41.95           8.17           50.12              74       -23.88        peak
    7221.045         38.63           8.17           46.8               54        -7.2         AVG



 Remark:
 Factor = Antenna Factor + Cable Loss – Pre-amplifier.


EUT:              ROBO ROLL-R                         Model Name. :            AW-ROBO-ROLL
Temperature:      20 ℃                                Relative Humidtity:      48%
Pressure:         1010 hPa                            Test Voltage :           DC3V
Test Mode :       Mode 1                              Polarization :           Vertical

    Frequency    Meter Reading      Factor      Emission Level     Limits       Margin
                                                                                            Value Type
      (MHz)         (dBμV)           (dB)         (dBμV/m)       (dBμV/m)        (dB)
     4814.03         43.06           3.76           46.82              74       -27.18        peak
     4814.03         41.84           3.76           45.6               54         -8.4        AVG
    7221.045         42.92           8.17           51.09              74       -22.91        peak
    7221.045         40.59           8.17           48.76              54        -5.24        AVG



 Remark:
 Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                                Page 15 of 31               Report No.: HK1810121272E



EUT:               ROBO ROLL-R                        Model Name.:             AW-ROBO-ROLL
Temperature:       20 ℃                               Relative Humidtity:      48%
Pressure:          1010 hPa                           Test Voltage:            DC3V
Test Mode :        Mode 2                             Polarization :           Horizontal

    Frequency    Meter Reading      Factor      Emission Level     Limits       Margin
                                                                                            Value Type
      (MHz)         (dBμV)           (dB)         (dBμV/m)       (dBμV/m)        (dB)
    4894.028         42.95           3.76           46.71              74       -27.29        peak
    4894.028         37.52           3.76           41.28              54       -12.72        AVG
    7341.042         42.57           8.17           50.74              74       -23.26        peak
    7341.042         39.61           8.17           47.78              54        -6.22        AVG



 Remark:
 Factor = Antenna Factor + Cable Loss – Pre-amplifier.




EUT:               ROBO ROLL-R                        Model Name. :            AW-ROBO-ROLL
Temperature:       20 ℃                               Relative Humidtity:      48%
Pressure:          1010 hPa                           Test Voltage :           DC3V
Test Mode :        Mode 2                             Polarization :           Vertical

   Frequency     Meter Reading      Factor      Emission Level     Limits       Margin
                                                                                            Value Type
     (MHz)          (dBμV)           (dB)         (dBμV/m)       (dBμV/m)        (dB)
    4894.028         40.85           3.76           44.61              74       -29.39        peak
    4894.028         37.21           3.76           40.97              54       -13.03        AVG
    7341.042         39.25           8.17           47.42              74       -26.58        peak
    7341.042         36.33           8.17           44.5               54        -9.5         AVG



 Remark:
 Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                                   Page 16 of 31               Report No.: HK1810121272E



  EUT:                ROBO ROLL-R                        Model Name.:             AW-ROBO-ROLL
  Temperature:        20 ℃                               Relative Humidtity:      48%
  Pressure:           1010 hPa                           Test Voltage:            DC3V
  Test Mode :         Mode 3                             Polarization :           Horizontal

       Frequency    Meter Reading      Factor      Emission Level     Limits       Margin
                                                                                               Value Type
         (MHz)         (dBμV)           (dB)         (dBμV/m)       (dBμV/m)        (dB)
       4954.022         42.15           3.76           45.91              74       -28.09        peak
       4954.022         39.25           3.76           43.01              54       -10.99        AVG
       7431.033         38.54           8.17           46.71              74       -27.29        peak
       7431.033         35.18           8.17           43.35              54       -10.65        AVG



    Remark:
    Factor = Antenna Factor + Cable Loss – Pre-amplifier.




  EUT:                ROBO ROLL-R                        Model Name. :            AW-ROBO-ROLL
  Temperature:        20 ℃                               Relative Humidtity:      48%
  Pressure:           1010 hPa                           Test Voltage :           DC3V
  Test Mode :         Mode 3                             Polarization :           Vertical

       Frequency    Meter Reading      Factor      Emission Level     Limits       Margin
                                                                                               Value Type
         (MHz)         (dBμV)           (dB)         (dBμV/m)       (dBμV/m)        (dB)
       4954.022         43.11           3.76           46.87              74       -27.13        peak
       4954.022         40.05           3.76           43.81              54       -10.19        AVG
       7431.033         39.12           8.17           47.29              74       -26.71        peak
       7431.033         36.04           8.17           44.21              54        -9.79        AVG



    Remark:
    Factor = Antenna Factor + Cable Loss – Pre-amplifier.


Note: Other emissions from 8G to 25 GHz are considered as ambient noise. No recording in the test report.
      Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      The “Factor” value can be calculated automatically by software of measurement system.


                                                    Page 17 of 31             Report No.: HK1810121272E

4. BAND EDGE EMISSION

4.1. MEASUREMENT PROCEDURE
1. The EUT operates at transmitting mode. The operate channel is tested to verify the largest transmission
and spurious emissions power at the continuous transmission mode.
2. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of
the emission: (a) PEAK: RBW=1MHz, VBW=3MHz , Sweep=AUTO
(b) AVERAGE: RBW=1MHz ; VBW=1/on time(1kHz), Sweep=AUTO
3. Other procedures refer to clause 3.1.

4.2 TEST SETUP

                                     RADIATED EMISSION TEST SETUP




4.3 RADIATED TEST RESULT
Note:
        1. Factor=Antenna Factor + Cable loss - Amplifier gain. Field Strength=Factor + Reading level
        2. The factor had been edited in the “Input Correction” of the Spectrum Analyzer. So the Amplitude of
        test plots is equal to Reading level plus the Factor in dB. Use the A dB(μV) to represent the Amplitude.
        Use the F dB(μV/m) to represent the Field Strength. So A=F.


                             Page 18 of 31          Report No.: HK1810121272E



EUT:           ROBO ROLL-R        Model Name. :         AW-ROBO-ROLL
Temperature:   20 ℃               Relative Humidtity:   48%
Pressure:      1010 hPa           Test Voltage :        DC3V
Test Mode :    Mode 1             Polarization :        Horizontal
                             PK Value


                             Page 19 of 31          Report No.: HK1810121272E



EUT:           ROBO ROLL-R        Model Name. :         AW-ROBO-ROLL
Temperature:   20 ℃               Relative Humidtity:   48%
Pressure:      1010 hPa           Test Voltage :        DC3V
Test Mode :    Mode 1             Polarization :        Vertical
                             PK Value


                             Page 20 of 31          Report No.: HK1810121272E



EUT:           ROBO ROLL-R        Model Name. :         AW-ROBO-ROLL
Temperature:   20 ℃               Relative Humidtity:   48%
Pressure:      1010 hPa           Test Voltage :        DC3V
Test Mode :    Mode 3             Polarization :        Horizontal
                             PK Value


                                                      Page 21 of 31                 Report No.: HK1810121272E



EUT:                 ROBO ROLL-R                            Model Name. :               AW-ROBO-ROLL
Temperature:         20 ℃                                   Relative Humidtity:         48%
Pressure:            1010 hPa                               Test Voltage :              DC3V
Test Mode :          Mode 3                                 Polarization :              Vertical
                                                     PK Value




 Note: The level of peak emission is less than the average limit, so the level of average emission need not to be tested.


                                              Page 22 of 31           Report No.: HK1810121272E

5. BANDWIDTH

5.1. MEASUREMENT PROCEDURE
 1. The EUT was placed on the top of the turntable 1.5 meter above ground. The phase center of the
    receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far
    away from the turntable.
 2, Set the EUT Work on the operation frequency individually.
 3. Set Span = approximately 2 to 5 times the OBW, centered on a hoping channel
    The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video
    bandwidth (VBW) shall be approximately 3* RBW; Sweep = auto; Detector function = peak
 4. Set SPA Trace 1 Max hold, then View.

5.2. TEST SETUP


                                        Page 23 of 31         Report No.: HK1810121272E

5.3. TEST RESULT
TEST ITEM                -20dB BANDWIDTH

TEST MODE                Mode1, Mode 2, Mode 3


               Channel                                  MHz               Criteria
             Low Channel                            1.180                  PASS
            Middle Channel                          1.300                  PASS
             High Channel                           1.345                  PASS

                   TEST PLOT OF BANDWIDTH FOR LOW CHANNEL


                 Page 24 of 31      Report No.: HK1810121272E

TEST PLOT OF BANDWIDTH FOR MIDDLE CHANNEL




 TEST PLOT OF BANDWIDTH FOR HIGH CHANNEL


                             Page 25 of 31   Report No.: HK1810121272E


6. PHOTOGRAPH OF TEST
                        Radiated Emission


                           Page 26 of 31   Report No.: HK1810121272E

7. PHOTOGRAPH OF EUT
                       ALL VEIW OF EUT


      Page 27 of 31   Report No.: HK1810121272E

 TOP VIEW OF EUT




BOTTOM VIEW OF EUT


     Page 28 of 31   Report No.: HK1810121272E


FRONT VIEW OF EUT




BACK VIEW OF EUT


     Page 29 of 31   Report No.: HK1810121272E


LEFT VIEW OF EUT




RIGHT VIEW OF EUT


       Page 30 of 31     Report No.: HK1810121272E


  OPEN VIEW OF EUT


                              Antenna




INTERNAL VIEW OF EUT-1


       Page 31 of 31     Report No.: HK1810121272E


INTERNAL VIEW OF EUT-2




----END OF REPORT----