Test Report

FCC ID: 2AANZRCMNTR

Test Report

Download: PDF
FCCID_3562838

                                                                                      Page 1 of 22




                     FCC Test Report
                          Report No.: AGC10295170803FE03


 FCC ID                         : 2AANZRCMNTR

 APPLICATION PURPOSE            : Original Equipment

 PRODUCT DESIGNATION            : Remote Control


 BRAND NAME                     : N/A

 MODEL NAME                     : NFL-RC-MNTR
                                  NFL-RC-MNTR-GBY, NFL-RC-MNTR-DAL,
                                  NFL-RC-MNTR-DEN, NFL-RC-MNTR-NE,
 SERIAL MODELS                  : NFL-RC-MNTR-OAK, NFL-RC-MNTR-NYG,
                                  NFL-RC-MNTR-PIT, NFL-RC-MNTR-SEA
                                  NFL-CAR-PIT, NFL-CAR-SEA
 CLIENT                         : DGL Group LTD.

 DATE OF ISSUE                  : July 06, 2017
 STANDARD(S)                    : FCC Part 15 Rules
 TEST PROCEDURE(S)
                                :
 REPORT VERSION                   V1.0




       Attestation of Global Compliance (Shenzhen) Co., Ltd

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.


                                                               Report No.: AGC10295170803FE03
                                                                                   Page 2 of 22


                                   Report Revise Record

Report Version   Revise Time   Issued Date     Valid Version              Notes

    V1.0              /        July 06, 2017       Valid             Original Report


                                                                                                             Report No.: AGC10295170803FE03
                                                                                                                                 Page 3 of 22


                                                            TABLE OF CONTENTS
1. VERIFICATION OF CONFORMITY .............................................................................................................. 4
2. GENERAL INFORMATION ........................................................................................................................... 5
3. MEASUREMENT UNCERTAINTY................................................................................................................ 6
4. DESCRIPTION OF TEST MODES................................................................................................................ 6
5. SYSTEM TEST CONFIGURATION .............................................................................................................. 7
     5.1. CONFIGURATION OF EUT SYSTEM ................................................................................................... 7
     5.2. EQUIPMENT USED IN EUT SYSTEM .................................................................................................. 7
     5.3. SUMMARY OF TEST RESULTS ........................................................................................................... 7
6. TEST FACILITY............................................................................................................................................. 8
7. RADIATED EMISSION.................................................................................................................................. 9
     7.1TEST LIMIT .............................................................................................................................................. 9
     7.2. MEASUREMENT PROCEDURE ......................................................................................................... 10
     7.3. TEST SETUP ....................................................................................................................................... 11
     7.4. TEST RESULT ..................................................................................................................................... 12
8. 20DB BANDWIDTH .................................................................................................................................... 15
     8.1. MEASUREMENT PROCEDURE ......................................................................................................... 15
     8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ............................................................... 15
     8.3. MEASUREMENT RESULTS ............................................................................................................... 16
APPENDIX A: PHOTOGRAPHS OF TEST SETUP ....................................................................................... 17
APPENDIX B: PHOTOGRAPHS OF EUT ...................................................................................................... 18


                                                                          Report No.: AGC10295170803FE03
                                                                                              Page 4 of 22


1. VERIFICATION OF CONFORMITY
Applicant                     DGL Group LTD.
Address                       195 Raritan Center Parkway Edison, New Jersey United States 08837
Manufacturer                  DGL Group LTD.
Address                       195 Raritan Center Parkway Edison, New Jersey United States 08837
Product Designation           Remote Control
Brand Name                    N/A
Test Model                    NFL-RC-MNTR
                              NFL-RC-MNTR-GBY, NFL-RC-MNTR-DAL, NFL-RC-MNTR-DEN,
Series model                  NFL-RC-MNTR-NE, NFL-RC-MNTR-OAK, NFL-RC-MNTR-NYG,
                              NFL-RC-MNTR-PIT, NFL-RC-MNTR-SEA , NFL-CAR-PIT, NFL-CAR-SEA
Difference Description        All are the same except the appearance.
Date of test                  July 05, 2017 to July 06, 2017
Deviation                     None
Condition of Test Sample      Normal
Report Template               AGCRT-US-BR/RF
We hereby certify that: The above equipment was tested by Dongguan Precise Testing Service Co., Ltd. The
test data, data evaluation, test procedures, and equipment configurations shown in this report were made in
accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT
tested as described in this report is in compliance with radiated emission limits of FCC Rules Part 15.227.




                          Tested by

                                               Max Zhang(Zhang Yi)        July 06, 2017


                         Reviewed by

                                               Bart Xie(Xie Xiaobin))     July 06, 2017

                         Approved by

                                           Solger Zhang(Zhang Hongyi)
                                                                          July 06, 2017
                                                Authorized Officer


                                                                         Report No.: AGC10295170803FE03
                                                                                             Page 5 of 22


2. GENERAL INFORMATION
A major technical description of EUT is described as following
Operation Frequency                          27.145MHz
Maximum field strength                       71.80 dBμV/m@3m(AV)
Modulation                                   AM
Number of channels                           1
Antenna Gain                                 3dBi
Antenna Designation                          Integral Antenna (Met 15.203 Antenna requirement)
Hardware Version                             YED1705T-01
Software Version                             V1.0
Power Supply                                 DC3V by battery


                                                                             Report No.: AGC10295170803FE03
                                                                                                 Page 6 of 22


3. MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a standard
uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。


                No.       Item                                     Uncertainty
                1         Conducted Emission Test                  ±3.18dB
                2         All emissions,radiated                   ±3.91Db
                3         Temperature                              ±0.5°C
                4         Humidity                                 ±2%


4. DESCRIPTION OF TEST MODES
   NO.                                     TEST MODE DESCRIPTION
     1                                             Transmitting mode
   Note:
   1. All the test modes can be supply by battery, only the result of the worst case was recorded in the
   report, if no other cases.
   2. For Radiated Emission, 3axis were chosen for testing for each applicable mode.


                                                               Report No.: AGC10295170803FE03
                                                                                   Page 7 of 22


5. SYSTEM TEST CONFIGURATION
5.1. CONFIGURATION OF EUT SYSTEM
Configure :



                EUT




5.2. EQUIPMENT USED IN EUT SYSTEM
 Item                 Equipment           Model No.      ID or Specification        Remark
  1               Remote control       NFL-RC-MNTR        2AANZRCMNTR                 EUT


5.3. SUMMARY OF TEST RESULTS

  FCC RULES                        DESCRIPTION OF TEST                         RESULT
      §15.227                        Radiated Emission                         Compliant
      §15.215                         20dB bandwidth                           Compliant


                                                                           Report No.: AGC10295170803FE03
                                                                                               Page 8 of 22


6. TEST FACILITY
         Site               Dongguan Precise Testing Service Co., Ltd.
                            Building D, Baoding Technology Park,Guangming Road2, Dongcheng District,
      Location
                            Dongguan, Guangdong, China.
 FCC Registration No.       371540
                            The test site is constructed and calibrated to meet the FCC requirements in
     Description
                            documents ANSI C63.4:2014.

ALL TEST EQUIPMENT LIST
                                     Radiated Emission Test Site
                                                Model          Serial               Last           Due
   Name of Equipment            Manufacturer
                                               Number        Number              Calibration    Calibration
                                  Rohde &
    EMI Test Receiver                           ESCI          101417            July 4, 2017    July 3, 2018
                                  Schwarz
 Trilog Broadband Antenna
                              SCHWARZBECK VULB9160               9160-3355      July 4, 2017    July 3, 2018
        (25M-1GHz)
      Signal Amplifier        SCHWARZBECK         BBV 9475       9745-0013      July 4, 2017    July 3, 2018
         RF Cable             SCHWARZBECK          AK9515E         96221        July 4, 2017    July 3, 2018
  3m Anechoic Chamber            CHENGYU              966         PTS-001       July 4, 2017    July 3, 2018
 MULTI-DEVICE Positioning
                                   Max-Full        MF-7802     MF780208339          N/A             N/A
        Controller
   Active loop antenna
                                Schwarzbeck       FMZB1519        1519-038      June 6, 2017   June 5, 2018
       (9K-30MHz)
    Spectrum analyzer                Agilent       E4407B       MY46185649      June 6, 2017   June 5, 2018


                                                                            Report No.: AGC10295170803FE03
                                                                                                Page 9 of 22


7. RADIATED EMISSION
7.1TEST LIMIT
Standard FCC15.227

Fundamental Frequency                 Field Strength of Fundamental         Field Strength of Fundamental
                                      (micro volts/meter) AV Detector       (micro volts/meter) PK Detector
26.96-27.28MHz                        10000(80 dBμV/m)                      100000(100 dBμV/m)


Standard FCC 15.209

Frequency                   Distance                                     Field Strengths Limit
(MHz)                       Meters                       μ V/m                       dB(μV)/m
0.009 ~ 0.490               300                          2400/F(kHz)                 ---
0.490 ~ 1.705               30                           24000/F(kHz)                ---
1.705 ~ 30                  30                           30                          ---
30 ~ 88                     3                            100                         40.0
88 ~ 216                    3                            150                         43.5
216 ~ 960                   3                            200                         46.0
960 ~ 1000                  3                            500                         54.0
Above 1000                  3                            Other:74.0 dB(μV)/m (Peak) 54.0 dB(μV)/m (Average)
Remark: (1) Emission level dBμ V = 20 log Emission level μ V/m
             (2) The smaller limit shall apply at the cross point between two frequency bands.
             (3) Distance is the distance in meters between the measuring instrument, antenna and the closest
                point of any part of the device or system.


                                                                          Report No.: AGC10295170803FE03
                                                                                             Page 10 of 22


7.2. MEASUREMENT PROCEDURE
  1. Configure the EUT according to ANSI C63.10. The EUT was placed on the top of the turntable 0.8 meter
     above ground. The phase center of the receiving antenna mounted on the top of a height-variable
     antenna tower was placed 3 meters far away from the turntable.
  2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
     the position of the highest radiation.
  3. The height of the broadband receiving antenna was varied between one meter and four meters above
     ground to find the maximum emissions field strength of both horizontal and vertical polarization.
  4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
     rotated (from 0 degree to 360 degrees) to find the maximum reading.
  5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
     under Maximum Hold Mode.
  6. If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
     testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
     have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
  7. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
     recorded data should be QP measured by receiver. High - Low scan is not required in this case.

The following table is the setting of spectrum analyzer and receiver.
                Spectrum Parameter                                            Setting
                Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                Receiver Parameter                                            Setting
                Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                                                           Report No.: AGC10295170803FE03
                                                                              Page 11 of 22


7.3. TEST SETUP
                  Radiated Emission Test-Setup Frequency Below 30MHz




                   RADIATED EMISSION TEST SETUP 30MHz-1000MHz


                                                                       Report No.: AGC10295170803FE03
                                                                                          Page 12 of 22


7.4. TEST RESULT
                                RADIATED EMISSION BELOW 30MHZ
   EUT:              Remote Control                   Model Name. :       NFL-RC-MNTR
   Temperature:      20 ℃                             Relative Humidtity: 48%
   Pressure:         1010 hPa                         Test Voltage :      DC3V
   Test Mode :       Mode 1                           Polarization :      --



                              Reading        Factor        Level       Limit
   Frequency                                                                      Margin
             Polarization     dB(uV)          dB         dB(uV/m)    dB(uV/m)               Pass/Fail
      MHz                                                                          dB
                                PK           (1/m)          PK          PK
     27.145        Face        58.33          14.5        72.83        100         27.17      Pass
     27.145        Side        50.45          14.5        64.95        100         35.05      Pass
                              Reading        Factor        Level       Limit
   Frequency                                                                      Margin
             Polarization     dB(uV)           dB        dB(uV/m)    dB(uV/m)               Pass/Fail
      MHz                                                                          dB
                                PK           (1/m)         AVG         AVG
     27.145        Face        57.30          14.5        71.80         80          8.20      Pass
     27.145        Side        49.07          14.5        63.57         80         16.43      Pass


Note: Other emissions from 9 kHz to 30 MHz are considered as ambient noise. No recording in the test
      report.


                                                            Report No.: AGC10295170803FE03
                                                                               Page 13 of 22


                            RADIATED EMISSION 30MHz- 1GHZ
 EUT:           Remote Control           Model Name. :       NFL-RC-MNTR
 Temperature:   20 ℃                     Relative Humidtity: 48%
 Pressure:      1010 hPa                 Test Voltage :      DC3V
 Test Mode :    Mode 1                   Polarization :      Horizontal




RESULT: PASS


                                                                      Report No.: AGC10295170803FE03
                                                                                         Page 14 of 22


 EUT:              Remote Control                  Model Name. :       NFL-RC-MNTR
 Temperature:      20 ℃                            Relative Humidtity: 48%
 Pressure:         1010 hPa                        Test Voltage :      DC3V
 Test Mode :       Mode 1                          Polarization :      Vertical




RESULT: PASS
Note:
    Factor=Antenna Factor + Cable loss, Margin=Result-Limit.
    The “Factor” value can be calculated automatically by software of measurement system.


                                                                            Report No.: AGC10295170803FE03
                                                                                               Page 15 of 22


8. 20DB BANDWIDTH
8.1. MEASUREMENT PROCEDURE
 1. The spectrum analyzer center frequency is set to the nominal EUT channel center frequency. The span
    range for the EMI receiver or spectrum analyzer shall be between two times and five times the OBW.
 2. The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video
    bandwidth (VBW) shall be approximately three times RBW, unless otherwise specified by the applicable
    requirement.
 3. Set the reference level of the instrument as required, keeping the signal from exceeding the maximum
    input mixer level for linear operation. In general, the peak of the spectral envelope shall be more than [10
    log (OBW/RBW)] below the reference level.
 4. Steps 1 through 3 might require iteration to adjust within the specified tolerances.


8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)


                                                  Report No.: AGC10295170803FE03
                                                                     Page 16 of 22


8.3. MEASUREMENT RESULTS

TEST ITEM                20DB BANDWIDTH

TEST MODE                Mode1


                        Test Data (kHz)                          Criteria
             Operate channel              7.220                   PASS


                                   Report No.: AGC10295170803FE03
                                                      Page 17 of 22


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
 RADIATED EMISSION TEST SETUP BELOW 30MHz




RADIATED EMISSION TEST SETUP 30MHz-1000MHz


                               Report No.: AGC10295170803FE03
                                                  Page 18 of 22


APPENDIX B: PHOTOGRAPHS OF EUT
        ALL VIEW OF EUT




        TOP VIEW OF EUT




                          Antenna


                     Report No.: AGC10295170803FE03
                                        Page 19 of 22


BOTTOM VIEW OF EUT




FRONT VIEW OF EUT


                   Report No.: AGC10295170803FE03
                                      Page 20 of 22


BACK VIEW OF EUT




LEFT VIEW OF EUT


                    Report No.: AGC10295170803FE03
                                       Page 21 of 22


RIGHT VIEW OF EUT




OPEN VIEW OF EUT


                         Report No.: AGC10295170803FE03
                                            Page 22 of 22


INTERNAL VIEW OF EUT-1




INTERNAL VIEW OF EUT-2




----END OF REPORT----



Document Created: 2017-09-15 05:54:02
Document Modified: 2017-09-15 05:54:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC