14_AW-QDR-CELL TestRpt

FCC ID: 2AANZQDRCELL

Test Report

Download: PDF
FCCID_3191053

                                                                                      Page 1 of 31




                     FCC Test Report

                          Report No.: AGC04900161002FE03




 FCC ID                         : 2AANZQDRCELL

 APPLICATION PURPOSE            : Original Equipment

 PRODUCT DESIGNATION            : Remote Control

 BRAND NAME                     : N/A

 MODEL NAME                     : AW-QDR-CELL

 CLIENT                         : DGL Group LTD.

 DATE OF ISSUE                  : Nov. 05, 2016
 STANDARD(S)
                                : FCC Part 15 Rules
 TEST PROCEDURE(S)
                                :
 REPORT VERSION                     V1.0




       Attestation of Global Compliance (Shenzhen) Co., Ltd

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.


                                                               Report No.: AGC04900161002FE03
                                                                                   Page 2 of 31


                                   Report Revise Record

Report Version   Revise Time   Issued Date     Valid Version              Notes

    V1.0              /        Nov. 05, 2016       Valid             Original Report


                                                                                                             Report No.: AGC04900161002FE03
                                                                                                                                 Page 3 of 31


                                                               TABLE OF CONTENTS
1. VERIFICATION OF CONFORMITY .............................................................................................................. 4
2. GENERAL INFORMATION ........................................................................................................................... 5
     2.1. PRODUCT DESCRIPTION ................................................................................................................... 5
     2.2. TABLE OF CARRIER FREQUENCY ..................................................................................................... 5
3. MEASUREMENT UNCERTAINTY................................................................................................................ 5
4. DESCRIPTION OF TEST MODES................................................................................................................ 6
5. SYSTEM TEST CONFIGURATION .............................................................................................................. 7
     5.1. CONFIGURATION OF EUT SYSTEM ................................................................................................... 7
     5.2. EQUIPMENT USED IN EUT SYSTEM .................................................................................................. 7
     5.3. SUMMARY OF TEST RESULTS ........................................................................................................... 7
6. TEST FACILITY............................................................................................................................................. 8
7. RADIATED EMISSION.................................................................................................................................. 9
     7.1TEST LIMIT .............................................................................................................................................. 9
     7.2. MEASUREMENT PROCEDURE ......................................................................................................... 10
     7.3. TEST SETUP ....................................................................................................................................... 12
     7.4. TEST RESULT ..................................................................................................................................... 13
8. BAND EDGE EMISSION............................................................................................................................. 18
     8.1. MEASUREMENT PROCEDURE ......................................................................................................... 18
     8.2 TEST SETUP ........................................................................................................................................ 18
     8.3 RADIATED TEST RESULT ................................................................................................................... 18
9. 20DB BANDWIDTH .................................................................................................................................... 23
     9.1. MEASUREMENT PROCEDURE ......................................................................................................... 23
     9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ............................................................... 23
     9.3. MEASUREMENT RESULTS ............................................................................................................... 23
APPENDIX A: PHOTOGRAPHS OF TEST SETUP ....................................................................................... 26
APPENDIX B: PHOTOGRAPHS OF EUT ...................................................................................................... 27


                                                                         Report No.: AGC04900161002FE03
                                                                                             Page 4 of 31


1. VERIFICATION OF CONFORMITY
Applicant                  DGL Group LTD.
Address                    195 Raritan Center Parkway Edison, New Jersey United States 08837
Manufacturer               DGL Group LTD.
Address                    195 Raritan Center Parkway Edison, New Jersey United States 08837
Product Designation        Remote Control
Brand Name                 N/A
Test Model                 AW-QDR-CELL
Date of test               Oct.20, 2016 to Oct. 21, 2016
Deviation                  None
Condition of Test Sample Normal
Test Result                Pass
Report Template            AGCRT-US-BR/RF
We hereby certify that:
The above equipment was tested by Dongguan Precise Testing Service Co., Ltd. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were made in accordance with
the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described
in this report is in compliance with radiated emission limits of FCC Rules Part 15.249.


                         Tested by

                                              Max Zhang(Zhang Yi)        Nov. 05, 2016


                       Reviewed by


                                              Bart Xie(Xie Xiaobin))     Nov. 05, 2016

                       Approved by

                                          Solger Zhang(Zhang Hongyi)
                                                                         Nov. 05, 2016
                                               Authorized Officer


                                                                        Report No.: AGC04900161002FE03
                                                                                            Page 5 of 31


2. GENERAL INFORMATION
2.1. PRODUCT DESCRIPTION
A major technical description of EUT is described as following
Operation Frequency                          2.405 GHz to 2.475GHz
Maximum field strength                       86.13dBuV/m@3m(AV)
Modulation                                   GFSK
Number of channels                           71
Antenna Gain                                 3dBi
Antenna Designation                          Wire Antenna (Met 15.203 Antenna requirement)
Hardware Version                             HY-851TX-LG
Software Version                             V1.0
Power Supply                                 DC 6V by battery


2.2. TABLE OF CARRIER FREQUENCY
    Frequency Band                     Channel Number                           Frequency
                                                1                               2405MHZ
                                                2                               2406MHZ
                                               …                                    …
    2400~2483.5MHZ
                                               …                                    …
                                               70                               2474MHZ
                                               71                               2475MHZ
 Note: The channel spacing is 1MHz.


                                                                             Report No.: AGC04900161002FE03
                                                                                                 Page 6 of 31


3. MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a standard
uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。


                No.       Item                                     Uncertainty
                1         Conducted Emission Test                  ±3.18dB
                2         All emissions,radiated                   ±3.91dB
                3         Temperature                              ±0.5°C
                4         Humidity                                 ±2%


4. DESCRIPTION OF TEST MODES
   NO.                                     TEST MODE DESCRIPTION
     1                                  Low channel TX in GFSK modulation
     2                                Middle channel TX in GFSK modulation
     3                                  High channel TX in GFSK modulation
   Note:
   1. All the test modes can be supply by battery, only the result of the worst case was recorded in the
   report, if no other cases.
   2. For Radiated Emission, 3axis were chosen for testing for each applicable mode.


                                                              Report No.: AGC04900161002FE03
                                                                                  Page 7 of 31


5. SYSTEM TEST CONFIGURATION
5.1. CONFIGURATION OF EUT SYSTEM
Configure 1:



                EUT




5.2. EQUIPMENT USED IN EUT SYSTEM
 Item                 Equipment         Model No.       ID or Specification        Remark
  1              Remote Control       AW-QDR-CELL       2AANZQDRCELL                 EUT


5.3. SUMMARY OF TEST RESULTS

  FCC RULES                       DESCRIPTION OF TEST                         RESULT
      §15.249                       Radiated Emission                         Compliant
      §15.249                         Band Edges                              Compliant
      §15.215                        20dB bandwidth                           Compliant


                                                                          Report No.: AGC04900161002FE03
                                                                                              Page 8 of 31


6. TEST FACILITY
         Site               Dongguan Precise Testing Service Co., Ltd.
                            Building D, Baoding Technology Park,Guangming Road2, Dongcheng District,
      Location
                            Dongguan, Guangdong, China.
 FCC Registration No.       371540
                            The test site is constructed and calibrated to meet the FCC requirements in
     Description
                            documents ANSI C63.4:2014.

ALL TEST EQUIPMENT LIST
                                     Radiated Emission Test Site
                                                Model          Serial              Last            Due
   Name of Equipment           Manufacturer
                                               Number        Number             Calibration     Calibration
                                 Rohde &
    EMI Test Receiver                           ESCI          101417            July 3, 2016    July 2, 2017
                                 Schwarz
 Trilog Broadband Antenna
                              SCHWARZBECK         VULB9160       9160-3355      July 3, 2016    July 2, 2017
        (25M-1GHz)
     Signal Amplifier         SCHWARZBECK         BBV 9475       9745-0013      July 3, 2016    July 2, 2017
        RF Cable              SCHWARZBECK          AK9515E          96221       July 3, 2016    July 2, 2017
  3m Anechoic Chamber            CHENGYU             966          PTS-001       June 3, 2016   June 2, 2017
MULTI-DEVICE Positioning
                                  Max-Full         MF-7802     MF780208339          N/A             N/A
       Controller
  Active loop antenna
                                Schwarzbeck       FMZB1519        1519-038      June 3, 2016   June 2, 2017
      (9K-30MHz)
    Spectrum analyzer                Agilent       E4407B       MY46185649      June 3, 2016   June 2, 2017
 Horn Antenna (1G-18GHz)      SCHWARZBECK BBHA9120D              9120D-1246     June 3, 2016   June 2, 2017
  Horn Ant (18G-40GHz)          Schwarzbeck      BBHA 9170        9170-181      June 3, 2016   June 2, 2017


                                                                            Report No.: AGC04900161002FE03
                                                                                                Page 9 of 31


7. RADIATED EMISSION
7.1TEST LIMIT
Standard FCC15.249

Fundamental Frequency                 Field Strength of Fundamental         Field Strength of Harmonics
                                      (millivolts/meter)                    (microvolts/meter)
900-928MHz                            50                                    500
2400-2483.5MHz                        50                                    500
5725-5875MHz                          50                                    500
24.0-24.25GHz                         250                                   2500


Standard FCC 15.209

Frequency                   Distance                                      Field Strengths Limit
(MHz)                       Meters                         μ V/m                     dB(μV)/m
0.009 ~ 0.490               300                            2400/F(kHz)               ---
0.490 ~ 1.705               30                             24000/F(kHz)              ---
1.705 ~ 30                  30                             30                        ---
30 ~ 88                     3                              100                       40.0
88 ~ 216                    3                              150                       43.5
216 ~ 960                   3                              200                       46.0
960 ~ 1000                  3                              500                       54.0
Above 1000                  3                              Other:74.0 dB(μV)/m (Peak) 54.0 dB(μV)/m (Average)
Remark: (1) Emission level dBμ V = 20 log Emission level μ V/m
             (2) The smaller limit shall apply at the cross point between two frequency bands.
             (3) Distance is the distance in meters between the measuring instrument, antenna and the closest
                point of any part of the device or system.


                                                                            Report No.: AGC04900161002FE03
                                                                                               Page 10 of 31


7.2. MEASUREMENT PROCEDURE
  1. The EUT was placed on the top of the turntable 0.8 or 1.5 meter above ground. The phase center of the
     receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away
     from the turntable.
  2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
     the position of the highest radiation.
  3. The height of the broadband receiving antenna was varied between one meter and four meters above
     ground to find the maximum emissions field strength of both horizontal and vertical polarization.
  4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
      rotated (from 0 degree to 360 degrees) to find the maximum reading.
  5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
     under Maximum Hold Mode.
  6. For emissions above 1GHz, use 1MHz VBW and RBW for peak reading. Then 1MHz RBW and 10Hz
     VBW for average reading in spectrum analyzer. Place the measurement antenna away from each area of
     the EUT determined to be a source of emissions at the specified measurement distance, while keeping
     the measurement antenna aimed at the source of emissions at each frequency of significant emissions,
     with polarization oriented for maximum response. The measurement antenna may have to be higher or
     lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission
     source for receiving the maximum signal. The final measurement antenna elevation shall be that which
     maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted
     to a range of heights of from 1 m to 4 m above the ground or reference ground plane.
  7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and
     pulsed operation is employed, the measurement field strength shall be determined by averaging over one
     complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds.
     As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
     pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
     absolute voltage during a 0.1 second interval during which the field strength is at its maximum values.
  8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
      testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
      have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
  9. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that
     means the emissions level in peak mode also complies with the limit in average mode), then testing will
     be stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in
     average mode again and reported.
10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
    recorded data should be QP measured by receiver. High - Low scan is not required in this case.


                                                                         Report No.: AGC04900161002FE03
                                                                                            Page 11 of 31


The following table is the setting of spectrum analyzer and receiver.
               Spectrum Parameter                                            Setting
               Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
               Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
               Start ~Stop Frequency                            30MHz~1000MHz/RB 120KHz for QP
                                                                        1GHz~26.5GHz
               Start ~Stop Frequency
                                                            1MHz/1MHz for Peak, 1MHz/10Hz for Average


              Receiver Parameter                                             Setting
               Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
               Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
               Start ~Stop Frequency                            30MHz~1000MHz/RB 120KHz for QP


                                                           Report No.: AGC04900161002FE03
                                                                              Page 12 of 31


7.3. TEST SETUP
                  Radiated Emission Test-Setup Frequency Below 30MHz




                   RADIATED EMISSION TEST SETUP 30MHz-1000MHz




                   RADIATED EMISSION TEST SETUP ABOVE 1000MHz


                                                                    Report No.: AGC04900161002FE03
                                                                                       Page 13 of 31


7.4. TEST RESULT
                              RADIATED EMISSION BELOW 30MHZ
          No emission found between lowest internal used/generated frequencies to 30MHz.
                               RADIATED EMISSION 30MHz- 1GHZ
 EUT:              Remote Control               Model Name. :       AW-QDR-CELL
 Temperature:      20 ℃                         Relative Humidtity: 48%
 Pressure:         1010 hPa                     Test Voltage :      DC6V
 Test Mode :       Mode 1                       Polarization :      Horizontal




RESULT: PASS


                                                                          Report No.: AGC04900161002FE03
                                                                                             Page 14 of 31




 EUT:               Remote Control                   Model Name. :       AW-QDR-CELL
 Temperature:       20 ℃                             Relative Humidtity: 48%
 Pressure:          1010 hPa                         Test Voltage :      DC6V
 Test Mode :        Mode 1                           Polarization :      Vertical




RESULT: PASS
Note:
    Factor=Antenna Factor + Cable loss, Margin=Result-Limit.
    The “Factor” value can be calculated automatically by software of measurement system.
    The mode 1 is the worst case, and only the data of the worst case recorded in this test report.


                                                                           Report No.: AGC04900161002FE03
                                                                                              Page 15 of 31


                                 RADIATED EMISSION ABOVE 1GHZ
EUT:             Remote Control                  Model Name. :               AW-QDR-CELL
Temperature:     20 ℃                            Relative Humidtity:         48%
Pressure:        1010 hPa                        Test Voltage :              DC6V
Test Mode :      Mode 1                          Polarization :              Horizontal


     Frequency   Meter Reading     Factor     Emission Level      Limits        Margin
                                                                                           Value Type
       (MHz)        (dBμV)          (dB)        (dBμV/m)       (dBμV/m)           (dB)
     2405.013        100.15         -9.37         90.78            114           -23.22       peak
     2405.013         95.12         -9.37         85.75            94             -8.25       AVG
     4810.026        48.38          3.74          52.12            74            -21.88       peak
     4810.026        43.21          3.74          46.95            54             -7.05       AVG
     7215.039        41.87          8.14          50.01            74            -23.99       peak
     7215.039        36.74          8.14          44.88            54            -9.12        AVG
   Remark:
   Factor = Antenna Factor + Cable Loss – Pre-amplifier.


EUT:             Remote Control                  Model Name. :               AW-QDR-CELL
Temperature:     20 ℃                            Relative Humidtity:         48%
Pressure:        1010 hPa                        Test Voltage :              DC6V
Test Mode :      Mode 1                          Polarization :              Vertical


     Frequency   Meter Reading     Factor     Emission Level      Limits        Margin
                                                                                           Value Type
       (MHz)        (dBμV)          (dB)        (dBμV/m)       (dBμV/m)           (dB)
     2405.013        98.07          -9.37         88.7             114           -25.3        peak
     2405.013        93.11          -9.37         83.74            94            -10.26       AVG
     4810.026        47.28          3.74          51.02            74            -22.98       peak
     4810.026        42.54          3.74          46.28            54             -7.72       AVG
     7215.039        41.67          8.14          49.81            74            -24.19       peak
     7215.039        36.53          8.14          44.67            54            -9.33        AVG
   Remark:
   Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                                                           Report No.: AGC04900161002FE03
                                                                                              Page 16 of 31


EUT:             Remote Control                  Model Name. :               AW-QDR-CELL
Temperature:     20 ℃                            Relative Humidtity:         48%
Pressure:        1010 hPa                        Test Voltage :              DC6V
Test Mode :      Mode 2                          Polarization :              Horizontal


     Frequency   Meter Reading     Factor     Emission Level      Limits        Margin
                                                                                           Value Type
       (MHz)        (dBμV)          (dB)        (dBμV/m)       (dBμV/m)           (dB)
     2445.016        99.67          -9.63         90.04            114           -23.96       peak
     2445.016        94.31          -9.63         84.68            94             -9.32       AVG
     4890.032        48.96          3.76          52.72            74            -21.28       peak
     4890.032        43.75          3.76          47.51            54             -6.49       AVG
     7335.048        43.22          8.17          51.39            74            -22.61       peak
     7335.048        38.09          8.17          46.26            54            -7.74        AVG
   Remark:
   Factor = Antenna Factor + Cable Loss – Pre-amplifier.




EUT:             Remote Control                  Model Name. :               AW-QDR-CELL
Temperature:     20 ℃                            Relative Humidtity:         48%
Pressure:        1010 hPa                        Test Voltage :              DC6V
Test Mode :      Mode 2                          Polarization :              Vertical


     Frequency   Meter Reading     Factor     Emission Level      Limits        Margin
                                                                                           Value Type
       (MHz)        (dBμV)          (dB)        (dBμV/m)       (dBμV/m)           (dB)
     2445.016        97.38          -9.63         87.75            114           -26.25       peak
     2445.016        92.15          -9.63         82.52            94            -11.48       AVG
     4890.032        47.94          3.76           51.7            74            -22.3        peak
     4890.032        42.59          3.76          46.35            54            -7.65        AVG
     7335.048        42.38          8.17          50.55            74            -23.45       peak
     7335.048        36.95          8.17          45.12            54            -8.88        AVG
   Remark:
   Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                                                               Report No.: AGC04900161002FE03
                                                                                                  Page 17 of 31


  EUT:               Remote Control                  Model Name. :               AW-QDR-CELL
  Temperature:       20 ℃                            Relative Humidtity:         48%
  Pressure:          1010 hPa                        Test Voltage :              DC6V
  Test Mode :        Mode 3                          Polarization :              Horizontal


        Frequency    Meter Reading     Factor    Emission Level       Limits        Margin
                                                                                               Value Type
          (MHz)         (dBμV)          (dB)        (dBμV/m)      (dBμV/m)            (dB)
         2475.021       101.18         -9.61         91.57             114           -22.43       peak
         2475.021        95.74         -9.61         86.13             94             -7.87       AVG
         4950.042        53.22          3.83         57.05             74            -16.95       peak
         4950.042        47.95          3.83         51.78             54             -2.22       AVG
         7425.063        41.85          8.21         50.06             74            -23.94       peak
         7425.063        36.74          8.21         44.95             54            -9.05        AVG
      Remark:
      Factor = Antenna Factor + Cable Loss – Pre-amplifier.


  EUT:               Remote Control                  Model Name. :               AW-QDR-CELL
  Temperature:       20 ℃                            Relative Humidtity:         48%
  Pressure:          1010 hPa                        Test Voltage :              DC6V
  Test Mode :        Mode 3                          Polarization :              Vertical


        Frequency    Meter Reading     Factor    Emission Level       Limits        Margin
                                                                                               Value Type
          (MHz)         (dBμV)          (dB)        (dBμV/m)      (dBμV/m)            (dB)
         2475.021        99.04         -9.61         89.43             114           -24.57       peak
         2475.021        93.58         -9.61         83.97             94            -10.03       AVG
         4950.042        51.76          3.83         55.59             74            -18.41       peak
         4950.042        46.28          3.83         50.11             54             -3.89       AVG
         7425.063        42.12          8.21         50.33             74            -23.67       peak
         7425.063        37.18          8.21         45.39             54            -8.61        AVG
      Remark:
      Factor = Antenna Factor + Cable Loss – Pre-amplifier.


Note: Other emissions from 8G to 25 GHz are considered as ambient noise. No recording in the test report.
      Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      The “Factor” value can be calculated automatically by software of measurement system.


                                                                              Report No.: AGC04900161002FE03
                                                                                                 Page 18 of 31


8. BAND EDGE EMISSION
8.1. MEASUREMENT PROCEDURE
1. The lowest or highest channels are tested to verify the largest transmission and spurious emissions power
at the continuous transmission mode.
2. Max hold the trace of the setp 1,and the EUT operates at hopping-on test mode to verify the largest
spurious emissions power.
3. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of the
emission: (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
(b) AVERAGE: RBW=1MHz ; VBW=1/on time(1KHz) / Sweep=AUTO


  8.2 TEST SETUP



                                     RADIATED EMISSION TEST SETUP




8.3 RADIATED TEST RESULT
Note:
        1. Factor=Antenna Factor + Cable loss - Amplifier gain. Field Strength=Factor + Reading level
        2. The factor had been edited in the “Input Correction” of the Spectrum Analyzer. So the Amplitude of test
        plots is equal to Reading level plus the Factor in dB. Use the A dB(μV) to represent the Amplitude. Use
        the F dB(μV/m) to represent the Field Strength. So A=F.


                                                         Report No.: AGC04900161002FE03
                                                                            Page 19 of 31




EUT:           Remote Control      Model Name. :           AW-QDR-CELL
Temperature:   20 ℃                Relative Humidtity:     48%
Pressure:      1010 hPa            Test Voltage :          DC6V
Test Mode :    Mode 1              Polarization :          Horizontal
                                PK Value




                                AV Value


                                                         Report No.: AGC04900161002FE03
                                                                            Page 20 of 31



EUT:           Remote Control      Model Name. :           AW-QDR-CELL
Temperature:   20 ℃                Relative Humidtity:     48%
Pressure:      1010 hPa            Test Voltage :          DC6V
Test Mode :    Mode 1              Polarization :          Vertical
                                PK Value




                                AV Value


                                                         Report No.: AGC04900161002FE03
                                                                            Page 21 of 31



EUT:           Remote Control      Model Name. :           AW-QDR-CELL
Temperature:   20 ℃                Relative Humidtity:     48%
Pressure:      1010 hPa            Test Voltage :          DC6V
Test Mode :    Mode 3              Polarization :          Horizontal
                                PK Value




                                AV Value


                                                                          Report No.: AGC04900161002FE03
                                                                                             Page 22 of 31



  EUT:              Remote Control                  Model Name. :           AW-QDR-CELL
  Temperature:      20 ℃                            Relative Humidtity:     48%
  Pressure:         1010 hPa                        Test Voltage :          DC6V
  Test Mode :       Mode 3                          Polarization :          Vertical
                                                PK Value




                                                AV Value




Note:
     Factor=Antenna Factor + Cable loss - Amplifier gain, Over=Measure-Limit.
     The “Factor” value can be calculated automatically by software of measurement system.


                                                                            Report No.: AGC04900161002FE03
                                                                                               Page 23 of 31


9. 20DB BANDWIDTH
9.1. MEASUREMENT PROCEDURE
 1. The spectrum analyzer center frequency is set to the nominal EUT channel center frequency. The span
    range for the EMI receiver or spectrum analyzer shall be between two times and five times the OBW.
 2. The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video
    bandwidth (VBW) shall be approximately three times RBW, unless otherwise specified by the applicable
    requirement.
 3. Set the reference level of the instrument as required, keeping the signal from exceeding the maximum
    input mixer level for linear operation. In general, the peak of the spectral envelope shall be more than [10
    log (OBW/RBW)] below the reference level.
 4. Set SPA Trace 1 Max hold, then View.


9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)




9.3. MEASUREMENT RESULTS

TEST ITEM                       20DB BANDWIDTH

TEST MODE                       Mode1;Mode2;Mode3


                              Test Data (MHz)                                                Criteria
                   Low Channel                                   5.723                        PASS
                  Middle Channel                                 5.445                        PASS
                   High Channel                                  4.349                        PASS


                                  Report No.: AGC04900161002FE03
                                                     Page 24 of 31


 TEST PLOT OF BANDWIDTH FOR LOW CHANNEL




TEST PLOT OF BANDWIDTH FOR MIDDLE CHANNEL


                                 Report No.: AGC04900161002FE03
                                                    Page 25 of 31


TEST PLOT OF BANDWIDTH FOR HIGH CHANNEL


                                   Report No.: AGC04900161002FE03
                                                      Page 26 of 31


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
 RADIATED EMISSION TEST SETUP BELOW 1GHz




 RADIATED EMISSION TEST SETUP ABOVE 1GHz


                           Report No.: AGC04900161002FE03
                                              Page 27 of 31


APPENDIX B: PHOTOGRAPHS OF EUT
       TOTAL VIEW OF EUT




        TOP VIEW OF EUT


                     Report No.: AGC04900161002FE03
                                        Page 28 of 31


BOTTOM VIEW OF EUT




FRONT VIEW OF EUT


                   Report No.: AGC04900161002FE03
                                      Page 29 of 31


BACK VIEW OF EUT




LEFT VIEW OF EUT


                    Report No.: AGC04900161002FE03
                                       Page 30 of 31


RIGHT VIEW OF EUT




OPEN VIEW OF EUT


                         Report No.: AGC04900161002FE03
                                            Page 31 of 31


INTERNAL VIEW OF EUT-1


                              Antenna




INTERNAL VIEW OF EUT-2




----END OF REPORT----