18_QKY-PLSE-WHT RFExp r2

FCC ID: 2AANZPLSE

RF Exposure Info

Download: PDF
FCCID_4320220

                           RF EXPOSURE EVALUATION

1. PRODUCT INFORMATION


   Product Description      PULSE Smart Digital Scale


      Model Name            QKY-PLSE-WHT, QKY-PLSE-BLK, QKY-PLSE, QKY-PLSE-XXXX


           FCC ID           2AANZPLSE


2. EVALUATION METHOD

According to 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR.
  Where f(GHz) is the RF channel transmit frequency in GHz
   Power and distance are rounded to the nearest mW and mm before calculation

3. CALCULATION



Pt=13.68dBm=23.33mW


The value of the Maximum output power Pt is referred to the test report of the CFR47

§15.247.

The result for RF exposure evaluation
SAR=(23.33mW/12.74mm) .[√2.437(GHz)]=2.86<3.0 for 1-g SAR and ≤ 7.5 for 10-g
extremity SAR.

min. test separation distance is 12.74mm


4. CONCLUSION

The SAR evaluation is not required.



Document Created: 2019-06-21 22:58:06
Document Modified: 2019-06-21 22:58:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC