RF Exposure Report

FCC ID: 2AANZMODB

RF Exposure Info

Download: PDF
FCCID_4193028

                    Test Report No.: FM190125N024


                                   RF EXPOSURE REPORT
   Applicant                       DGL Group, LTD


   Address                         195 Raritan Center Parkway, Edison, NJ08837-3650, US


   Manufacturer or
                                   DGL Group, LTD
   Supplier

   Address                         195 Raritan Center Parkway, Edison, NJ08837-3650, US

   Product                         BT Module

   Brand Name                      N/A

   Model                           2AANZMODB-ECL

   Additional Model &
                                   N/A
   Model Difference

   Date of tests                   Jan. 25, 2019 ~ Jan. 30, 2019

        FCC Part 2 (Section 2.1091)
        KDB 447498 D01
        IEEE C95.1

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                       Tested by Breeze Jiang                                                          Approved by Glyn He
                 Project Engineer / EMC Department                                                  Supervisor/ EMC Department




                                                                                                           Date: Feb. 18, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
   report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
   representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
   expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
   Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
   material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
   and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
   acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.



                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 6                                                             Report Version 1


                Test Report No.: FM190125N024

                                    TABLE OF CONTENTS
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FM190125N024


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FM190125N024             Original release                                                        Feb. 18, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FM190125N024

   1. CERTIFICATION

                        FCC ID:     2AANZMODB
                   PRODUCT:         BT Module

              BRAND NAME:           N/A

                 MODEL NO.:         2AANZMODB-ECL

         ADDITIONAL NO.:            N/A

                 APPLICANT:         DGL Group,LTD

               STANDARDS:           FCC Part 2 (Section 2.1091)

                                    KDB 447498 D01

                                    IEEE C95.1




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 6                                                    Report Version 1


                Test Report No.: FM190125N024

   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm2)                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm


   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 6                                                      Report Version 1


   — Test Report No.: FM190125N024

   5. ANTENNA GAIN

        The antennas provided to the EUT, please refer to the following table:
               Transmitter                                                                      Antenna
                    .   I.                           Peak Gain (dBi)
                  Circuit                                                                           Type
                  Chain 0                                     —1                             PCB Antenna



   6. CALCULATION RESULT OF MAXIMUM CONDUCTED AV POWER
   The tuned conducted Average Power (declared by client)
                                                          Target                                       Lower                 Upper
        Mode                 Fr?l\cilllj_lezr;cy          Power              To(lgéa::)c©            Tolerance             Tolerance
                                                          (dBm)                                        (dBm)                 (dBm)
       GFSK               2402—2480                         —1                   +—1                       —2                    0
      8BDPSK                 2402—2480                      —1                   +—1                       —2                    0
     LE— GFSK                2402—2480                      —4                   +—3                       —7                   —1


   The measured conducted Average Power

                                                            Frequency                                  Averaged Power
                Mogds                                            (MHz)                                          (dBm)
               GFSK                                              2480                                           —0.63
               8BDPSK                                            2480                                           —0.92
             LE— GFSK                                            2402                                           —2.35



     FREQUENCY           |MAX AVERAGE|                    ANTENNA                                           POWER
       BAND                 POWER                           GAIN                 DIS(-:;f‘n'\)lCE          DENSITY               (mI;I:II\/n;-rI;nz)
        (MHz)                (dBm)                          (dBi)                                          (mW/cm*)

       2402—2480                         0                         —1                  20                  0.000158                     1.0




    ——— END ———




                                                   No. 34, Chenwulu Section, Guantai Rd., Houjie       Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.                                    ,
                                                   Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                                           .                                 .
                                                   Guangdong 523942, China                             Email: customerservice.dg@cn.bureauveritas.com

                                                                        Page 6 of 6                                                      Report Version 1



Document Created: 2019-07-08 21:57:14
Document Modified: 2019-07-08 21:57:14

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC