18_QKY-BOIL-SLV RFExp

FCC ID: 2AANZBOIL

RF Exposure Info

Download: PDF
FCCID_4490745

                           RF EXPOSURE EVALUATION

1. PRODUCT INFORMATION

   Product Description         Smart Water Kettle

       Model Name              QKY-BOIL-SLV, QKY-BOIL

            FCC ID             2AANZBOIL

2. EVALUATION METHOD AND LIMIT
Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be
evaluated based on the MPE limits adopted by the FCC for electric and magnetic field
strength and/or power density, as appropriate, since exposures are assumed to occur at
distances of 20 cm or more from persons.
LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
   Frequency      E-field Strength Magnetic Field      Power Density Averaging Time
     Range               (E)         Strength (H)           (S)         |E|2, |H|2 or S
     (MHz)              (V/m)            (A/m)           (mW/cm2)         (Minutes)
0.3 -- 1.34              614               1.63              (100)*               30
1.34 -- 30               824/f             2.19/f           (180/f2)*             30
30 -- 300                27.5              0.073               0.2                30
300 -- 1500               --                 --              f/1500               30
1500 -- 100,000           --                 --                1.0                30
*Note:
1. f= Frequency in MHz * Plane-wave Equivalent Power Density
2. The averaging time for General Population/Uncontrolled exposure to fixed transmitters
is not applicable for mobile and portable transmitters. See 47 CFR §§2.1091 and 2.1093
on source-based time-averaging requirement for mobile and portable transmitters.


S=PG/4πR²
Where:
  S=power density
  P=power input to antenna
  G=power gain of the antenna in the direction of interest relative to an isotropic radiator
  R=distance to the center of radiation of the antenna


CALCULATION

A minimum test separation distance ≥ 20 cm is required between the antenna and
radiating structures of the device and nearby persons to apply mobile device exposure
limits. The distance must be at least 20 cm and fully supported by the operating and
installation configurations of the transmitter and its antenna(s), according to the
source-based time-averaged maximum power requirements of § 2.1091(d)(2). In cases
where cable losses or other attenuations are applied to determine compliance, the most
conservative operating configurations and exposure conditions must be evaluated.

Antenna Gain=3dBi (Numeric 2), π=3.14


   Frequency    Output Power    Output Power   Power Density    Power Density Limit


      MHz           dBm               mW          mW/cm2              mW/cm2


      2412          16.53             44.98        0.0179                1


Note: Only the worst case recorded.



Document Created: 2019-10-28 17:45:04
Document Modified: 2019-10-28 17:45:04

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC