RF Exposure Evaluation (above 20 cm)

FCC ID: 2AAJCBR20

RF Exposure Info

Download: PDF
FCCID_4195463

                                                                                                                        D-PL-12076-01-03




                        Maximum Permissible Exposure (MPE) &
                                            Exposure evaluation


                              Report identification number: 1-5475/17-01-139




                                   Certification numbers and labeling requirements
 FCC ID                                                             2AAJCBR20
 IC number                                                          24305-BR20
 HVIN (Hardware Version Identification Number)                      MQB37W
 PMN (Product Marketing Name)                                       MQB37W
 FVIN (Firmware Version Identification Number)                      -/-
 HMN (Host Marketing Name)                                          -/-




This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


                                                                  Document authorized:
                                                                                                  DN: cn=Thomas Vogler, o=CTC advanced
                                                                                                  GmbH, ou=VOG-161125,
                                                                                                  email=thomas.vogler@ctcadvanced.com,
                                                                                                  c=DE
                                                                                                  Datum: 2018.09.26 12:37:37 +02'00'

                                                                  Thomas Vogler
                                                                  Lab Manager
                                                                  Radio Communications & EMC




                                                         Page 1 of 3


EUT technologies:

     Technologies:                  Max. output:                  Max. antenna gain:       Min. pathloss:
         FSK                 67.25 dBµV/m @3 m AVG
                                                                         n/a               -- (if applicable)
     @433.9 MHz                 = -28.11 dBm EIRP

Prediction of MPE limit at given distance - FCC

Equation from page 18 of OET Bulletin 65, Edition 97-01

S = PG / 4π R2

where: S = Power density
       P = Power input to the antenna
       G = Antenna gain
       R = Distance to the center of radiation of the antenna

The table below is excerpted from Table 1B of 47 CFR 1.1310 titled “Limits for Maximum Permissible Exposure
(MPE), Limits for General Population/Uncontrolled Exposure”

     Frequency Range (MHz)                Power Density (mW/cm2)               Averaging Time (minutes)
           300 -1500                              f/1500                                  30
         1500 - 100000                              1.0                                   30

where f = Frequency (MHz)


Prediction: worst case

                                                                         < 1500 MHz
                            Technology                               433 MHz application
                      PG    Max EIRP                                      < -20 dBm
                      R     Distance                                        20 cm
                      S     MPE limit for uncontrolled exposure         0.289 mW/cm2
                            Calculated Power density:               < 0.00000034 mW/cm²

This prediction demonstrates the following:

The power density levels for FCC at a distance of 20 cm are below the maximum levels allowed by regulations.




                                                 Page 2 of 3


Prediction of MPE limit at given distance - IC

RSS-102, Issue 5, 2.5.2

RF exposure evaluation is required if the separation distance between the user and/or bystander and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:
        • below 20 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
        than 1 W (adjusted for tune-up tolerance);
        • at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of the
        device is equal to or less than 4.49/ƒ0.5W (adjusted for tune-up tolerance), where ƒ is in MHz;
        • at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p. of the
        device is equal to or less than 0.6 W (adjusted for tune-up tolerance);
        • at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the
        device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where ƒ is in MHz;
        • at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or
        less than 5 W (adjusted for tune-up tolerance).


Prediction: worst case

                                         Technology              433 MHz application
                          PG             Max EIRP                     -38.7 dBm
                                         Max EIRP                    0.00017 mW
                                 Exclusion Limit from above            831 mW


Conclusion: RF exposure evaluation is not required.
            For applications where minimum distance to radiating element is 20cm Annex C of RSS-102
            should be filled out.




                                                  Page 3 of 3



Document Created: 2018-09-26 12:37:37