Test Report

FCC ID: 2AAIL-MM008

Test Report

Download: PDF
FCCID_4386880

                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                   1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua
                                   District, Shenzhen, China
                                   Telephone:     +86-755-26648640
                                   Fax:           +86-755-26648637                 Report Template Version: V03
                                   Website:        www.cqa-cert.com                Report Template Revision Date: Mar.1st,
                                                                                   2017



                                             Test Report
1      Cover page

Report No. :                     CQAS20190700610E-01

Applicant:                       DongGuan Mae Tay Electronic Co.,Ltd

Address of Applicant:            Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong, China
Manufacturer:                    DongGuan Mae Tay Electronic Co.,Ltd
Address of                       Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong, China
Manufacturer:
Equipment Under Test (EUT):
Product:               Wireless Verticle Ergonamic Mouse
Model No.:             NS-PWME20
Brand Name:            N/A
FCC ID:                2AAIL-MM008
IC :                   11188A-MM008
Standards:                       47 CFR Part 15, Subpart C
                                 RSS-210 Issue 9 August 2016
                                 RSS-Gen Issue 5 March 2019
Date of Test:                    2019-07-18 to 2019-07-22
Date of Issue:                   2019-07-22
 Test Result :                   PASS*




Tested By:
                                                 (Tom Chen)


Reviewed By:
                                                 (Aaron Ma)


Approved By:
                                                  ( Jack Ai)



* In the configuration tested, the EUT complied w ith the standards specified above.

The test report is effective only w ith both signature and specialized stamp, The result(s) show n in this report refer only to

the sample(s) tested. Without w ritten approval of CQA, this report can’t be reproduced except in full.


                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQAS20190700610E-01

2 Version
                         Revision History Of Report

        Report No.       Version           Description            Issue Date
   CQAS20190700610E-01    Rev.01           Initial report        2019-07-22




                           Page:2 of 34


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                    Report No.: CQAS20190700610E-01

3     Test Summary

                                   FCC Test
           Test Item                                   IC Test Requirement     Test method      Result
                                 Requirement
                                47 CFR Part 15,
    Antenna Requirement        Subpart C Section       RSS-Gen Section 6.8 ANSI C63.10-2013     PASS
                                    15.203

    AC Power Line               47 CFR Part 15,
                               Subpart C Section       RSS-Gen Section 8.8 ANSI C63.10-2013      N/A
    Conducted Emission              15.207

                                47 CFR Part 15,                              RSS-Gen section
    Field Strength of the
                               Subpart C Section          RSS 210 B 10(a)        6.12 &         PASS
    Fundamental Signal             15.249 (a)                                ANSI C63.10-2013

                                47 CFR Part 15,                              RSS-Gen section
    Spurious Emissions         Subpart C Section          RSS 210 B 10 (b)       6.13 &         PASS
                                   15.249(a)                                 ANSI C63.10-2013
                                                                             RSS-Gen section
    Restricted bands           47 CFR Part 15,                                   6.13 &
    around fundamental        Subpart C Section           RSS 210 B 10 (b)                      PASS
    frequency                15.249 (d), (e)/15.209                            ANSI C63.10-
                                                                                  2013

                                47 CFR Part 15,                            RSS-Gen section
    20dB Occupied
                               Subpart C Section       RSS-Gen section 6.7     6.7 &            PASS
    Bandwidth                      15.215 (c)                                ANSI C63.10-2013
    99% Occupied                                                             RSS-Gen section
                                       /               RSS-Gen section 6.7                      PASS
    Bandwidth                                                                     6.7

    N/A:   Not applicable, This EUT is battery power




                                           Page:3 of 34


                                                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                      Report No.: CQAS20190700610E-01


    4      Contents

                                                                                                                                                                               Page
1       COVER PAGE...................................................................................................................................................................1

2       VERSION ..........................................................................................................................................................................2

3       TEST SUMMARY ...........................................................................................................................................................3

4       CONTENTS ......................................................................................................................................................................4

5       GENERAL INFORMATION .........................................................................................................................................5
    5.1     CLIENT INFORMAT ION ............................................................................................................................................... 5
    5.2     GENERAL DESCRIPT ION OF EUT............................................................................................................................... 5
    5.3     TEST ENVIRONMENT AND M ODE ............................................................................................................................. 7
    5.4     DESCRIPT ION OF SUPPORT UNIT S ........................................................................................................................... 7
    5.5     ST AT EMENT OF T HE MEASUREMENT UNCERT AINT Y ......................................................................................... 8
    5.6     TEST LOCAT ION........................................................................................................................................................... 9
    5.7     TEST FACILIT Y ............................................................................................................................................................ 9
    5.8     DEVIAT ION FROM ST ANDARDS................................................................................................................................. 9
    5.9     A BNORMALIT IES FROM ST ANDARD CONDIT IONS ................................................................................................ 9
    5.10       OT HER INFORMAT ION REQUEST ED BY T HE CUST OMER ................................................................................ 9
    5.11       EQUIPMENT LIST .................................................................................................................................................. 10
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 11
    6.1     A NT ENNA REQUIREMENT ....................................................................................................................................... 11
    6.2     RADIAT ED SPURIOUS EMISSION & FIELD ST RENGT H OF FUNDAMENT AL ...................................................... 12
    6.3     REST RICT ED BANDS AROUND FUNDAMENT AL FREQUENCY ............................................................................. 21
    6.4     20DB BANDWIDT H .................................................................................................................................................... 27
    6.5     99% OCCUPY BANDWIDT H...................................................................................................................................... 30
7       PHOTOGRAPHS......................................................................................................................................................... 33
    7.1     RADIAT ED EMISSION TEST SET UP ......................................................................................................................... 33
    7.2     EUT CONST RUCT IONAL DET AILS .......................................................................................................................... 34




                                                                       Page:4 of 34


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                          Report No.: CQAS20190700610E-01


5   General Information

5.1 Client Information
    Applicant:               DongGuan Mae Tay Electronic Co.,Ltd
    Address of Applicant:    Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong,
                             China
    Manufacturer:            DongGuan Mae Tay Electronic Co.,Ltd
    Address of               Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong,
    Manufacturer:
                             China

5.2 General Description of EUT
    Name:                   Wireless Verticle Ergonamic Mouse
    Model No.:              NS-PWME20
    Trade Mark :            N/A
    Hardware Version:       Ver.02
    Software Version:       Ver.02
    Frequency Range:        2408MHz ~ 2474MHz
    Modulation Type:        FSK
    Number of Channels:     34 (declared by the client)
    Sample Type:            Portable product
    Antenna Type:           PCB antenna
    Antenna Gain:           -1.0dBi
    Power Supply:           DC3.0V (AAA battery x 2)




                                      Page:5 of 34


                                            Shenzhen Huaxia Testing Technology Co., Ltd
                                                                Report No.: CQAS20190700610E-01


Operation Frequency each of channel
 Channel      Frequency     Channel    Frequency     Channel    Frequency     Channel    Frequency
    1          2408MHz        10       2426MHz          19       2444MHz         28      2462MHz
    2          2410MHz        11       2428MHz          20       2446MHz         29      2464MHz
    3          2412MHz        12       2430MHz          21       2448MHz         30      2466MHz
    4          2414MHz        13       2432MHz          22       2450MHz         31      2468MHz
    5          2416MHz        14       2434MHz          23       2452MHz         32      2470MHz
    6          2418MHz        15       2436MHz          24       2454MHz         33      2472MHz
    7          2420MHz        16       2438MHz          25       2456MHz         34      2474MHz
    8          2422MHz        17       2440MHz          26       2458MHz          /          /
    9          2424MHz        18       2442MHz          27       2460MHz          /          /


Note:
   In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency,
    the middle frequency, and the highest frequency of channel were selected to perform the test, and
    the selected channel see below:

               Channel                   Frequency
        The Lowest channel(CH1)           2408MHz
    The Middle channel(CH17)              2440MHz
    The Highest channel(CH34)             2474MHz




                                      Page:6 of 34


                                          Shenzhen Huaxia Testing Technology Co., Ltd
                                                              Report No.: CQAS20190700610E-01


5.3 Test Environment and Mode
   Operating Environment:
   Temperature:            25.0 C
   Humidity:               52 % RH
   Atmospheric Pressure:   1001 mbar
   Test Mode:              Use test software (RF test) to set the lowest frequency, the middle
                           frequency and the highest frequency keep transmitting of the EUT.


5.4 Description of Support Units
   The EUT has been tested with associated equipment below.

                                                                                    FCC
     Description       Manufacturer            Model No.        Remark
                                                                                certification
          /                  /                      /              /                  /




                                     Page:7 of 34


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                                Report No.: CQAS20190700610E-01




5.5 Statement of the measurement uncertainty
    The data and results referenced in this document are true and accurate.
    The reader is cautioned that there may be errors within the calibration limits of the equipment and
    facilities.
    The measurement uncertainty was calculated for all measurements listed in this test report acc. to
    CISPR 16 - 4 „Specification for radio disturbance and immunity measuring apparatus and methods
    – Part 4: Uncertainty in EMC Measurements“ and is documented in the Shenzhen Huaxia
    Testing Technology Co., Ltd quality system acc. to DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in
    additional deviation. The manufacturer has the sole responsibility of continued compliance of the
    device.
    Hereafter the best measurement capability for CQA laboratory is reported:

     No.     Item                                     Uncertainty             Notes

     1       Radiated Emission (Below 1GHz)           5.12dB                  (1)

     2       Radiated Emission (Above 1GHz)           4.60dB                  (1)

     3       Conducted Disturbance                    3.34dB                  (1)
             (0.15~30MHz)

     4       Radio Frequency                          3×10-8                  (1)

     5       Duty cycle                               0.6 %.                  (1)

     6       Occupied Bandwidth                       1.1%                    (1)

     7       RF conducted power                       0.86dB                  (1)

     8       RF power density                         0.74                    (1)
     9       Conducted Spurious emissions             0.86dB                  (1)

     10      Temperature test                         0.8℃                    (1)

     11      Humidity test                            2.0%                    (1)

     12      Supply voltages                          0.5 %.                  (1)

     13      time                                     0.6 %.                  (1)

     14      Frequency Error                          5.5 Hz                  (1)

    (1)This uncertainty represents an expanded uncertainty expressed at approximatel y the 95%
    confidence level using a coverage factor of k=2.




                                     Page:8 of 34


                                          Shenzhen Huaxia Testing Technology Co., Ltd
                                                             Report No.: CQAS20190700610E-01




5.6 Test Location
    All tests were performed at:
    Shenzhen Huaxia Testing Technology Co., Ltd.,
    1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
    Shenzhen, China

5.7 Test Facility
      • ISED No.: 22984
     Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory is recognized by
    Innovation, Science and Economic Development Canada to test to Canadian radio equipment
    requirements
      • A2LA (Certificate No. 4742.01)
     Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory is accredited by the
       American Association for Laboratory Accreditation(A2LA). Certificate No. 4742.01.
      • FCC Registration No.: 522263
     Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory has been registered
     and fully described in a report filed with the (FCC) Federal Communications Commission. The
     acceptance letter from the FCC is maintained in our files. Registration No.:522263



5.8 Deviation from Standards
    None.

5.9 Abnormalities from Standard Conditions
    None.

5.10 Other Information Requested by the Customer
    None.




                                    Page:9 of 34


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                     Report No.: CQAS20190700610E-01


 5.11 Equipment List


                                                                    Instrument   Calibration Calibration
  Test Equipment        Manufacturer        Model No.                   No.         Date     Due Date
 EMI Test Receiver         R&S                 ESR7                  CQA-005     2018/9/26   2019/9/25
 Spectrum analyzer         R&S                FSU26                  CQA-038     2018/10/28 2019/10/27
                                         AFS4-00010300-18-
                                                                                 2018/9/26    2019/9/25
     Preamplifier          MITEQ               10P-4                CQA-035
                                        AMF-6D-02001800-29-
                                                                                 2018/11/2    2019/11/1
     Preamplifier         MITEQ                 20P                 CQA-036
    Loop antenna        Schwarzbeck         FMZB1516                CQA-060      2018/10/28 2020/10/27
    Bilog Antenna          R&S                HL562                 CQA-011      2018/9/26  2020/9/25
    Horn Antenna           R&S                HF906                 CQA-012      2018/9/26  2020/9/25
    Horn Antenna        Schwarzbeck         BBHA 9170               CQA-088      2018/9/26  2020/9/25
    Coaxial Cable
    (Above 1GHz)            CQA                   N/A                 C019       2018/9/26    2019/9/25
   Coaxial Cable
   (Below 1GHz)             CQA                  N/A                 C020        2018/9/26    2019/9/25
 Antenna Connector          CQA                 RFC-01              CQA-080      2018/9/26    2019/9/25
        RF
cable(9KHz~40GHz)           CQA               RF-01                 CQA-079      2018/9/26    2019/9/25
                                         PWD-2533-02-SMA-
    Power divider        MIDWEST               79                   CQA-067      2018/9/26    2019/9/25


Note:
The temporary antenna connector is soldered on the PCB board in order to perform conducted tests and
this temporary antenna connector is listed in the equipment list.




                                        Page:10 of 34


                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190700610E-01




6    Test results and Measurement Data

6.1 Antenna Requirement
    Standard requirement:         47 CFR Part 15C Section 15.203;
                                  RSS-Gen Section 6.8
      15.203 requirement:
     An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
     responsible party shall be used with the device. The use of a permanently attached antenna or of
     an
     antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the
     unit
     so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
     electrical connector is prohibited.
     EUT Antenna:
    The antenna is integrated on the main PCB and no consideration of replacement. The best case
    gain of the antenna is -1.0dBi.




                                           Page:11 of 34


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                                Report No.: CQAS20190700610E-01




 6.2 Radiated Spurious Emission & Field strength of fundamental
Test Requirement:     47 CFR Part 15C Section 15.249 (a), (d), (e) and 15.209
                      RSS 210 B 10 (a)
    Test Method:      ANSI C63.10 & RSS-Gen section 6.12/6.13
    Test Site:        Measurement Distance: 3m (Semi-Anechoic Chamber)
Receiver Setup:              Frequency            Detector        RBW            VBW          Remark
                        0.009MHz-0.090MHz            Peak        10kHz          30KHz          Peak
                        0.009MHz-0.090MHz           Average      10kHz          30KHz         Average
                        0.090MHz-0.110MHz        Quasi-peak      10kHz          30KHz        Quasi-peak
                        0.110MHz-0.490MHz            Peak        10kHz          30KHz          Peak
                        0.110MHz-0.490MHz           Average      10kHz          30KHz         Average
                         0.490MHz -30MHz         Quasi-peak      10kHz          30kHz        Quasi-peak
                           30MHz-1GHz            Quasi-peak     100 kHz         300KHz       Quasi-peak
                                                     Peak        1MHz           3MHz           Peak
                            Above 1GHz
                                                     Peak        1MHz            10Hz         Average
                      Note: For fundamental frequency, RBW=5MHz, VBW=5MHz, Peak detector is for
                            PK value, RMS detector is for Average value.
     Limit:                                   Field strength                                   Measuremen
                                                                  Limit                              t
(Spurious Emissions        Frequency         (microvolt/meter                    Remark
                                                                (dBuV/m )
and band edge)                                       )                                         distance (m)
                           0.009MHz-
                                               2400/F(kHz)           -              -              300
                           0.490MHz
                           0.490MHz-
                                               24000/F(kHz)          -              -              30
                           1.705MHz
                        1.705MHz-30MHz               30              -              -              30
                         30MHz-88MHz                100                  40.0   Quasi-peak            3
                         88MHz-216MHz               150                  43.5   Quasi-peak            3
                        216MHz-960MHz               200                  46.0   Quasi-peak            3
                         960MHz-1GHz                500                  54.0   Quasi-peak            3
                          Above 1GHz                500                  54.0    Average              3
                      Note: 1) 15.35(b), Unless otherwise specified, the limit on peak radio frequency
                            emissions is 20dB above the maximum permitted average emission limit
                            applicable to the equipment under test. This peak limit applies to the total
                            peak emission level radiated by the device.
                            2) Emissions radiated outside of the specified frequency bands, except for
                            harmonics, shall be attenuated by at least 50 dB below the level of the


                                    Page:12 of 34


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQAS20190700610E-01

                            fundamental or to the general radiated emission limits in Section 15.209,
                            whichever is the lesser attenuation.




    Limit:                   Frequency            Limit (dBuV/m @3m)            Remark
(Field strength of the                                    94.0               Average Value
                         2400MHz-2483.5MHz
fundamental signal)                                       114.0               Peak Value




                                    Page:13 of 34


                                             Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190700610E-01



    Test Setup:




                                         Figure 1. Below 30MHz

                                                          150cm




             Figure 2. 30MHz to 1GHz                                  Figure 3. Above 1 GHz
Test Procedure:       a. 1) Below 1G: The EUT was placed on the top of a rotating table 0.8 meters
                         above the ground at a 3 meter semi-anechoic camber. The table was rotated 360
                         degrees to determine the position of the highest radiation.
                         2) Above 1G: The EUT was placed on the top of a rotating table 1.5 meters
                         above the ground at a 3 meter semi-anechoic camber. The table was rotated 360
                         degrees to determine the position of the highest radiation.
                         Note: For the radiated emission test above 1GHz:
                         Place the measurement antenna away from each area of the EUT determined to
                         be a source of emissions at the specified measurement distance, while keeping
                         the measurement antenna aimed at the source of emissions at each frequency
                         of significant emissions, with polarization oriented for maximum response. The
                         measurement antenna may have to be higher or lower than the EUT, depending
                         on the radiation pattern of the emission and staying aimed at the emission
                         source for receiving the maximum signal. The final measurement antenna
                         elevation shall be that which maximizes the emissions. The measurement
                         antenna elevation for maximum emissions shall be restricted to a range of
                         heights of from 1 m to 4 m above the ground or reference ground plane.
                      b. The EUT was set 3 meters away from the interference-receiving antenna, which
                         was mounted on the top of a variable-height antenna tower.
                      c. The antenna height is varied from one meter to four meters above the ground to
                         determine the maximum value of the field strength. Both horizontal and vertical


                                       Page:14 of 34


                                             Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQAS20190700610E-01

                            polarizations of the antenna are set to make the measurement.
                        d. For each suspected emission, the EUT was arranged to its worst case and then
                            the antenna was tuned to heights from 1 meter to 4 meters (for the test
                            frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the
                            rotatable table was turned from 0 degrees to 360 degrees to find the maximum
                            reading.
                        e. The test-receiver system was set to Peak Detect Function and Specified
                            Bandwidth with Maximum Hold Mode.
                        f. If the emission level of the EUT in peak mode was 10dB lower than the limit
                            specified, then testing could be stopped and the peak values of the EUT would
                            be reported. Otherwise the emissions that did not have 10dB margin would be
                            re-tested one by one using peak, quasi-peak or average method as specified
                            and then reported in a data sheet.
                        g. Test the EUT in the lowest channel,the middle channel,the Highest channel
                        h. The radiation measurements are performed in X, Y, Z axis positioning for
                            Transmitting mode,And found the X axis positioning which it is worse case.
                        i. Repeat above procedures until all frequencies measured was complete.
Exploratory        Test Transmitting with FSK at lowest, middle and highest channel.
Mode:
Final Test Mode:        Pretest the EUT at Transmitting mode, For below 1GHz part, through pre-scan, the
                        worst case is the highest channel.
                        Only the worst case is recorded in the report.
Test Voltage:           DC3.0V
Test Results:           Pass




                                       Page:15 of 34


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                              Report No.: CQAS20190700610E-01



 Measurement Data


Field Strength Of The Fundamental Signal


                  Meter                 Emission                                   Ant. Pol.
     Frequency   Reading    Factor       Level       Limits     Over    Detector
       (MHz)      (dBμV)     (dB)       (dBμV/m) (dBμV/m)       (dB)     Type        H/V

        2408        97.28    -9.02        88.26       114      -25.74    Peak         H
        2408        95.73    -9.02        86.71       94       -7.29     AVG          H
        2408        94.28    -9.02        85.26       114      -28.74    Peak         V
        2408        92.75    -9.02        83.73       94       -10.27    AVG          V
        2440        99.90    -8.96        90.94       114      -23.06    Peak         H
        2440        98.41    -8.96        89.45       94       -4.55     AVG          H
        2440        95.78    -8.96        86.82       114      -27.18    Peak         V
        2440        94.23    -8.96        85.27       94       -8.73     AVG          V
        2474      101.86     -8.74        93.12       114      -20.88    Peak         H
        2474      100.34     -8.74        91.60       94       -2.40     AVG          H
        2474        97.26    -8.74        88.52       114      -25.48    Peak         V
        2474        95.82    -8.74        87.08       94       -6.92     AVG          V




                                     Page:16 of 34


                                         Shenzhen Huaxia Testing Technology Co., Ltd
                                                        Report No.: CQAS20190700610E-01



Spurious Emissions
30MHz~1GHz (the worst case)
Test mode:            Transmitting (Highest channel)    Vertical




                                  Page:17 of 34


                                         Shenzhen Huaxia Testing Technology Co., Ltd
                                                        Report No.: CQAS20190700610E-01


30MHz~1GHz (the worst case)
Test mode:            Transmitting (Highest channel)    Horizontal




                                  Page:18 of 34


                                       Shenzhen Huaxia Testing Technology Co., Ltd
                                                            Report No.: CQAS20190700610E-01


Above 1GHz
Test mode:             Transmitting              Test channel:            Lowest
              Meter                 Emission                                         Ant. Pol.
Frequency    Reading    Factor       Level        Limits         Over     Detector
  (MHz)      (dBμV)      (dB)       (dBμV/m) (dBμV/m)            (dB)      Type        H/V

   4816       56.26      -1.24        55.02         74           -18.98     Peak        H
   4816       41.85      -1.24        40.61         54           -13.39     AVG         H
   7224       47.33      5.98         53.31         74           -20.69     Peak        H
   7224       36.01      5.98         41.99         54           -12.01     AVG         H
   4816       51.43      -1.24        50.19         74           -23.81     peak        V
   4816       37.2       -1.24        35.96         54           -18.04     AVG         V
   7224       47.5       5.98         53.48         74           -20.52     peak        V
   7224       36.64      5.98         42.62         54           -11.38     AVG         V
Test mode:             Transmitting              Test channel:            Middle
              Meter                 Emission                                         Ant. Pol.
Frequency    Reading    Factor       Level        Limits         Over     Detector
  (MHz)      (dBμV)      (dB)       (dBμV/m) (dBμV/m)            (dB)      Type        H/V

   4880       56.19      -0.82        55.37         74           -18.63     peak        H
   4880       42.3       -0.82        41.48         54           -12.52     AVG         H
   7320       47.83      5.91         53.74         74           -20.26     peak        H
   7320       36.64      5.91         42.55         54           -11.45     AVG         H
   4880       51.13      -0.82        50.31         74           -23.69     peak        V
   4880       37.88      -0.82        37.06         54           -16.94     AVG         V
   7320       47.88      5.91         53.79         74           -20.21     peak        V
   7320       36.18      5.91         42.09         54           -11.91     AVG         V
Test mode:             Transmitting              Test channel:            Highest
              Meter                 Emission                                         Ant. Pol.
Frequency    Reading    Factor       Level        Limits         Over     Detector
  (MHz)      (dBμV)      (dB)       (dBμV/m) (dBμV/m)            (dB)      Type        H/V

   4948       55.99      -0.49        55.50         74           -18.50     peak        H
   4948       41.29      -0.49        40.80         54           -13.20     AVG         H
   7422       47.44      5.74         53.18         74           -20.82     peak        H
   7422       36.3       5.74         42.04         54           -11.96     AVG         H
   4948       50.38      -0.49        49.89         74           -24.11     peak        V
   4948       37.03      -0.49        36.54         54           -17.46     AVG         V
   7422       47.26      5.74         53.00         74           -21.00     peak        V
   7422       36.62      5.74         42.36         54           -11.64     AVG         V

                                 Page:19 of 34


                                              Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190700610E-01




Remark:
1) The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
   equation with a sample calculation is as follows:
   Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor

2) Scan from 9kHz to 25GHz,The disturbance above 8GHz and below 30MHz was very low, and the
   above harmonics were the highest point could be found when testing, so only the above harmonics
   had been displayed. The amplitude of spurious emissions from the radiator which are attenuated
   more than 20dB below the limit need not be reported .




                                       Page:20 of 34


                                             Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190700610E-01




6.3 Restricted bands around fundamental frequency
Test Requirement:          47 CFR Part 15C Section 15.249 (d), 15.209 and 15.205;
                           RSS 210 B 10 (b)
Test Method:               ANSI C63.10 :2013 & RSS-Gen section 6.13
Test Site:                 Measurement Distance: 3m (Semi-Anechoic Chamber)
                           Emissions radiated outside of the specified frequency bands, except for
Limit(Band Edge):          harmonics, shall be attenuated by at least 50 dB below the level of the
                           fundamental or to the general radiated emission limits in Section 15.209,
                           whichever is the lesser attenuation.
                                   Frequency            Limit (dBµV/m @3m)            Remark
                                                                                    Quasi-peak
                                 30MHz-88MHz                    40.0
                                                                                      Value
                                                                                    Quasi-peak
                                88MHz-216MHz                    43.5
                                                                                      Value
                                                                                    Quasi-peak
                               216MHz-960MHz                    46.0
                                                                                      Value
                                                                                    Quasi-peak
                                 960MHz-1GHz                    54.0
                                                                                      Value
                                                                54.0              Average Value
                                  Above 1GHz
                                                                74.0                Peak Value
Test Setup:




          Figure 1. 30MHz to 1GHz                                   Figure 2. Above 1 GHz
                        Below 1GHz test procedure as below:
Test Procedure:         j. The EUT was placed on the top of a rotating table 0.8 meters above the
                              ground at a 3 meter semi-anechoic camber. The table was rotated 360
                              degrees to determine the position of the highest radiation.
                           k. The EUT was set 3 meters away from the interference-receiving antenna,
                              which was mounted on the top of a variable-height antenna tower.
                           l. The antenna height is varied from one meter to four meters above the ground
                              to determine the maximum value of the field strength. Both horizontal and
                              vertical polarizations of the antenna are set to make the measurement.
                           m. For each suspected emission, the EUT was arranged to its worst case and
                              then the antenna was tuned to heights from 1 meter to 4 meters (for the test
                              frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the
                              rotatable table was turned from 0 degrees to 360 degrees to find the


                                      Page:21 of 34


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                    Report No.: CQAS20190700610E-01

                                 maximum reading.
                            n.   The test-receiver system was set to Peak Detect Function and Specified
                                 Bandwidth with Maximum Hold Mode.
                            o.   If the emission level of the EUT in peak mode was 10dB lower than the limit
                                 specified, then testing could be stopped and the peak values of the EUT
                                 would be reported. Otherwise the emissions that did not have 10dB margin
                                 would be re-tested one by one using peak, quasi-peak or average method as
                                 specified and then reported in a data sheet.
                            Above 1GHz test procedure as below:
                            p.   Different between above is the test site, change from Semi - Anechoic
                                 Chamber to fully Anechoic Chamber and change form table 0.8 metre to 1.5
                                 metre( Above 18GHz the distance is 1 meter and table is 1.5 metre).
                            q.   Test the EUT in the lowest channel , the Highest channel
                            r.   The radiation measurements are performed in X, Y, Z axis positioning for
                                 Transmitting mode, and found the X axis positioning which it is worse case.
                            s.   Repeat above procedures until all frequencies measured was complete.
 Test Mode:                 Transmitting with FSK at lowest, middle and highest channel.
 Test Voltage:              DC3.0V
 Test Results:              Pass


Test plot as follows:
Test mode:       Transmitting     Test channel:    Lowest            Remark:          Vertical




                                        Page:22 of 34


      Shenzhen Huaxia Testing Technology Co., Ltd
                     Report No.: CQAS20190700610E-01




Page:23 of 34


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                     Report No.: CQAS20190700610E-01



Test mode:   Transmitting   Test channel:   Lowest      Remark:        Horizontal




                                Page:24 of 34


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQAS20190700610E-01



Test mode:   Transmitting   Test channel:   Highest      Remark:        Vertical




                                Page:25 of 34


                                              Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190700610E-01



Test mode:       Transmitting      Test channel:    Highest           Remark:           Horizontal




Remark:
   The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
   equation with a sample calculation is as follows:
   Final Test Level =Receiver Reading - Correct Factor
   Correct Factor = Preamplifier Factor– Antenna Factor–Cable Factor




                                       Page:26 of 34


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                          Report No.: CQAS20190700610E-01




6.4 20dB Bandwidth
     Test Requirement:   47 CFR Part 15C Section 15.215
                         RSS-Gen Section 6.7
     Test Method:        ANSI C63.10:2013 & RSS-Gen Section 6.7
     Test Setup:




     Test Mode:          Transmitting with FSK at lowest, middle and highest channel.
     Limit:              N/A
     Test Results:       Pass


Measurement Data
        Test channel             20dB bandwidth (MHz)                       Results
              Lowest                     2.229                               Pass
              Middle                     2.243                               Pass
              Highest                    2.287                               Pass




                                Page:27 of 34


                                        Shenzhen Huaxia Testing Technology Co., Ltd
                                                       Report No.: CQAS20190700610E-01



 Test plot as follows:
Test channel:            Lowest




                                  Page:28 of 34


                                Shenzhen Huaxia Testing Technology Co., Ltd
                                               Report No.: CQAS20190700610E-01



Test channel:   Middle




Test channel:   Highest




                          Page:29 of 34


                                       Shenzhen Huaxia Testing Technology Co., Ltd
                                                          Report No.: CQAS20190700610E-01




6.5 99% Occupy Bandwidth
     Test Requirement:   RSS-Gen Section 6.7
     Test Method:        RSS-Gen Section 6.7
     Test Setup:




     Test Mode:          Transmitting with FSK at lowest, middle and highest channel.
     Limit:              N/A
     Test Results:       Pass


Measurement Data
        Test channel           99% Occupy Bandwidth (MHz)                   Results
              Lowest                  2.199710564                            Pass
              Middle                  2.185238784                            Pass
              Highest                 2.185238784                            Pass




                                 Page:30 of 34


                                        Shenzhen Huaxia Testing Technology Co., Ltd
                                                       Report No.: CQAS20190700610E-01



 Test plot as follows:
Test channel:            Lowest




                                  Page:31 of 34


                                Shenzhen Huaxia Testing Technology Co., Ltd
                                               Report No.: CQAS20190700610E-01



Test channel:   Middle




Test channel:   Highest




                          Page:32 of 34


                               Shenzhen Huaxia Testing Technology Co., Ltd
                                              Report No.: CQAS20190700610E-01




7.2 EUT Constructional Details




                             END OF THE REPORT




                         Page:34 of 34



Document Created: 2019-07-24 14:06:19
Document Modified: 2019-07-24 14:06:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC