Test Report

FCC ID: 2AAIL-MM007

Test Report

Download: PDF
FCCID_4319770

                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                   1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua
                                   District, Shenzhen, China
                                   Telephone:      +86-755-26648640
                                   Fax:            +86-755-26648637                Report Template Version: V03
                                   Website:         www.cqa-cert.com               Report Template Revision Date: Mar.1st,
                                                                                   2017



                                             Test Report
1      Cover page

Report No. :                     CQAS20190500392E-01

Applicant:                       DongGuan Mae Tay Electronic Co.,Ltd

Address of Applicant:            Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong, China
Manufacturer:                    DongGuan Mae Tay Electronic Co.,Ltd
Address of                       Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong, China
Manufacturer:
Equipment Under Test (EUT):
Product:               Wirelss Mouse
Model No.:             DX-PNC2019
Brand Name:            N/A
FCC ID:                2AAIL-MM007
Standards:                       47 CFR Part 15, Subpart C
Date of Test:                    2019-05-30 to 2019-06-03
Date of Issue:                   2019-06-03
 Test Result :                   PASS*




Tested By:
                                                  (Daisy Qin)


Reviewed By:
                                                 (Aaron Ma)


Approved By:
                                                   ( Jack Ai)




* In the configuration tested, the EUT complied w ith the standards specified above.

The test report is effective only w ith both signature and specialized stamp, The result(s) show n in this report refer only to

the sample(s) tested. Without w ritten approval of CQA, this report can’t be reproduced except in full.


                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQAS20190500392E-01

2 Version
                         Revision History Of Report

        Report No.       Version           Description            Issue Date
   CQAS20190500392E-01    Rev.01           Initial report        2019-06-03




                           Page:2 of 29


                                       Shenzhen Huaxia Testing Technology Co., Ltd
                                                          Report No.: CQAS20190500392E-01

3    Test Summary
           Test Item               FCC Test Requirement             Test method      Result
                              47 CFR Part 15, Subpart C Section
     Antenna Requirement                                          ANSI C63.10-2013   PASS
                                           15.203
        AC Power Line         47 CFR Part 15, Subpart C Section
                                                                  ANSI C63.10-2013    N/A
     Conducted Emission                    15.207

     Field Strength of the    47 CFR Part 15, Subpart C Section
                                                                  ANSI C63.10-2013   PASS
     Fundamental Signal                  15.249 (a)

      Spurious Emissions      47 CFR Part 15, Subpart C Section   ANSI C63.10-2013   PASS
    Restricted bands around   47 CFR Part 15, Subpart C Section
                                                                  ANSI C63.10-2013   PASS
    fundamental frequency           15.249 (d), (e)/15.209
        20dB Occupied         47 CFR Part 15, Subpart C Section
                                                                  ANSI C63.10-2013   PASS
          Bandwidth                      15.215 (c)




                                  Page:3 of 29


                                                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                      Report No.: CQAS20190500392E-01


 4         Contents

                                                                                                                                                                               Page
1 Cover Page1COVER PAGE ...........................................................................................................................................1

2       VERSION ..........................................................................................................................................................................2

3       TEST SUMMARY ...........................................................................................................................................................3

4       CONTENTS ......................................................................................................................................................................4

5       GENERAL INFORMATION .........................................................................................................................................5
    5.1     CLIENT INFORMAT ION ............................................................................................................................................... 5
    5.2     GENERAL DESCRIPT ION OF EUT............................................................................................................................... 5
    5.3     TEST ENVIRONMENT AND M ODE ............................................................................................................................. 7
    5.4     DESCRIPT ION OF SUPPORT UNIT S ........................................................................................................................... 7
    5.5     ST AT EMENT OF T HE MEASUREMENT UNCERT AINT Y ......................................................................................... 8
    5.6     TEST LOCAT ION........................................................................................................................................................... 9
    5.7     TEST FACILIT Y ............................................................................................................................................................ 9
    5.8     DEVIAT ION FROM ST ANDARDS................................................................................................................................. 9
    5.9     A BNORMALIT IES FROM ST ANDARD CONDIT IONS ................................................................................................ 9
    5.10       OT HER INFORMAT ION REQUEST ED BY T HE CUST OMER ................................................................................ 9
    5.11       EQUIPMENT LIST .................................................................................................................................................. 10
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 11
    6.1     A NT ENNA REQUIREMENT ....................................................................................................................................... 11
    6.2     RADIAT ED SPURIOUS EMISSION & FIELD ST RENGT H OF FUNDAMENT AL ...................................................... 12
    6.3     REST RICT ED BANDS AROUND FUNDAMENT AL FREQUENCY ............................................................................. 20
    6.4     20DB BANDWIDT H .................................................................................................................................................... 26
7       PHOTOGRAPHS......................................................................................................................................................... 29
    7.1     RADIAT ED EMISSION TEST SET UP ......................................................................................................................... 29




                                                                       Page:4 of 29


                                          Shenzhen Huaxia Testing Technology Co., Ltd
                                                          Report No.: CQAS20190500392E-01


5   General Information

5.1 Client Information
    Applicant:               DongGuan Mae Tay Electronic Co.,Ltd
    Address of Applicant:    Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong,
                             China
    Manufacturer:            DongGuan Mae Tay Electronic Co.,Ltd
    Address of               Beihuanlu Industrial Area, Changping Town Dongguan, Guangdong,
    Manufacturer:
                             China

5.2 General Description of EUT
    Name:                   Wireless Mouse
    Model No.:              DX-PNC2019
    Trade Mark :            N/A
    Hardware Version:       V0.1
    Software Version:       V0.1
    Frequency Range:        2408MHz ~ 2474MHz
    Modulation Type:        FSK
    Number of Channels:     34 (declared by the client)
    Sample Type:            Portable product
    Antenna Type:           PCB antenna
    Antenna Gain:           3.2dBi
    Power Supply:           DC3.0V (AAA battery x 2)




                                     Page:5 of 29


                                            Shenzhen Huaxia Testing Technology Co., Ltd
                                                                Report No.: CQAS20190500392E-01


Operation Frequency each of channel
 Channel      Frequency     Channel    Frequency     Channel    Frequency     Channel    Frequency
    1          2408MHz        10       2426MHz          19       2444MHz         28      2462MHz
    2          2410MHz        11       2428MHz          20       2446MHz         29      2464MHz
    3          2412MHz        12       2430MHz          21       2448MHz         30      2466MHz
    4          2414MHz        13       2432MHz          22       2450MHz         31      2468MHz
    5          2416MHz        14       2434MHz          23       2452MHz         32      2470MHz
    6          2418MHz        15       2436MHz          24       2454MHz         33      2472MHz
    7          2420MHz        16       2438MHz          25       2456MHz         34      2474MHz
    8          2422MHz        17       2440MHz          26       2458MHz          /          /
    9          2424MHz        18       2442MHz          27       2460MHz          /          /


Note:
   In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency,
    the middle frequency, and the highest frequency of channel were selected to perform the test, and
    the selected channel see below:

               Channel                   Frequency
        The Lowest channel(CH1)           2408MHz
    The Middle channel(CH17)              2440MHz
    The Highest channel(CH34)             2474MHz




                                      Page:6 of 29


                                          Shenzhen Huaxia Testing Technology Co., Ltd
                                                              Report No.: CQAS20190500392E-01


5.3 Test Environment and Mode
   Operating Environment:
   Temperature:            24.0 C
   Humidity:               52 % RH
   Atmospheric Pressure:   1008 mbar
   Test Mode:              Use test software (RF test) to set the lowest frequency, the middle
                           frequency and the highest frequency keep transmitting of the EUT.


5.4 Description of Support Units
   The EUT has been tested with associated equipment below.

                                                                                   FCC
     Description       Manufacturer            Model No.        Remark
                                                                                certification
          /                  /                      /              /                  /




                                     Page:7 of 29


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQAS20190500392E-01




5.5 Statement of the measurement uncertainty
    The data and results referenced in this document are true and accurate.
    The reader is cautioned that there may be errors within the calibration limits of the equipment and
    facilities.
    The measurement uncertainty was calculated for all measurements listed in this test report acc. to
    CISPR 16 - 4 „Specification for radio disturbance and immunity measuring apparatus and methods
    – Part 4: Uncertainty in EMC Measurements“ and is documented in the Shenzhen Huaxia
    Testing Technology Co., Ltd quality system acc. to DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in
    additional deviation. The manufacturer has the sole responsibility of continued compliance of the
    device.
    Hereafter the best measurement capability for CQA laboratory is reported:

     No.     Item                                      Uncertainty            Notes

     1       Radiated Emission (Below 1GHz)            ±5.12dB                (1)

     2       Radiated Emission (Above 1GHz)            ±4.60dB                (1)

     3       Conducted Disturbance                     ±3.34dB                (1)
             (0.15~30MHz)

     4       Radio Frequency                           3×10-8                 (1)

     5       Duty cycle                                0.6 %.                 (1)

     6       Occupied Bandwidth                        1.1%                   (1)

     7       RF conducted power                        0.86dB                 (1)

     8       RF power density                          0.74                   (1)
     9       Conducted Spurious emissions              0.86dB                 (1)

     10      Temperature test                          0.8℃                   (1)

     11      Humidity test                             2.0%                   (1)

     12      Supply voltages                           0.5 %.                 (1)

     13      time                                      0.6 %.                 (1)

     14      Frequency Error                           5.5 Hz                 (1)

    (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.




                                     Page:8 of 29


                                          Shenzhen Huaxia Testing Technology Co., Ltd
                                                             Report No.: CQAS20190500392E-01




5.6 Test Location
    All tests were performed at:
    Shenzhen Huaxia Testing Technology Co., Ltd.,
    1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
    Shenzhen, China

5.7 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L5785)
    CNAS has accredited Shenzhen Huaxia Testing Technology Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
      • ISED No.: 22984
     Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory is recognized by
    Innovation, Science and Economic Development Canada to test to Canadian radio equipment
    requirements
      • A2LA (Certificate No. 4742.01)
     Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory is accredited by the
       American Association for Laboratory Accreditation(A2LA). Certificate No. 4742.01.
      • FCC Registration No.: 522263
     Shenzhen Huaxia Testing Technology Co., Ltd., Shenzhen EMC Laboratory has been registered
     and fully described in a report filed with the (FCC) Federal Communications Commission. The
     acceptance letter from the FCC is maintained in our files. Registration No.:522263



5.8 Deviation from Standards
    None.

5.9 Abnormalities from Standard Conditions
    None.

5.10 Other Information Requested by the Customer
    None.




                                    Page:9 of 29


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                     Report No.: CQAS20190500392E-01


 5.11 Equipment List


                                                                    Instrument   Calibration Calibration
   Test Equipment       Manufacturer          Model No.
                                                                        No.         Date     Due Date
 EMI Test Receiver          R&S                ESR7                  CQA-005     2018/9/26   2019/9/25
 Spectrum analyzer          R&S               FSU26                  CQA-038     2018/10/28 2019/10/27
                                         AFS4-00010300-18-
     Preamplifier          MITEQ                                    CQA-035      2018/9/26    2019/9/25
                                               10P-4
                                        AMF-6D-02001800-29-
     Preamplifier          MITEQ                                    CQA-036      2018/11/2    2019/11/1
                                                20P
    Loop antenna        Schwarzbeck         FMZB1516                CQA-060      2018/10/28 2020/10/27
    Bilog Antenna          R&S                HL562                 CQA-011      2018/9/26  2020/9/25
    Horn Antenna           R&S                HF906                 CQA-012      2018/9/26  2020/9/25
    Horn Antenna        Schwarzbeck         BBHA 9170               CQA-088      2018/9/26  2020/9/25
    Coaxial Cable
                            CQA                   N/A                 C019       2018/9/26    2019/9/25
    (Above 1GHz)
    Coaxial Cable
                            CQA                   N/A                 C020       2018/9/26    2019/9/25
    (Below 1GHz)
 Antenna Connector          CQA                 RFC-01              CQA-080      2018/9/26    2019/9/25
        RF
                            CQA                  RF-01              CQA-079      2018/9/26    2019/9/25
cable(9KHz~40GHz)
                                         PWD-2533-02-SMA-
    Power divider        MIDWEST                                    CQA-067      2018/9/26    2019/9/25
                                               79


Note:
The temporary antenna connector is soldered on the PCB board in order to perform conducted tests and
this temporary antenna connector is listed in the equipment list.




                                        Page:10 of 29


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQAS20190500392E-01




6    Test results and Measurement Data

6.1 Antenna Requirement
     Standard requirement:         47 CFR Part 15C Section 15.203;
      15.203 requirement:
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a permanently attached antenna or of
      an
      antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the
      unit
      so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
      electrical connector is prohibited.
     EUT Antenna:




The antenna is integrated on the main PCB and no consideration of replacement. The best case gain of
the antenna is 3.2dBi.




                                            Page:11 of 29


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                                Report No.: CQAS20190500392E-01




 6.2 Radiated Spurious Emission & Field strength of fundamental
Test Requirement:     47 CFR Part 15C Section 15.249 (a), (d), (e) and 15.209
    Test Method:      ANSI C63.10
    Test Site:        Measurement Distance: 3m (Semi-Anechoic Chamber)
Receiver Setup:              Frequency            Detector        RBW            VBW          Remark
                        0.009MHz-0.090MHz            Peak        10kHz          30KHz          Peak
                        0.009MHz-0.090MHz           Average      10kHz          30KHz         Average
                        0.090MHz-0.110MHz        Quasi-peak      10kHz          30KHz        Quasi-peak
                        0.110MHz-0.490MHz            Peak        10kHz          30KHz          Peak
                        0.110MHz-0.490MHz           Average      10kHz          30KHz         Average
                         0.490MHz -30MHz         Quasi-peak      10kHz          30kHz        Quasi-peak
                           30MHz-1GHz            Quasi-peak     100 kHz         300KHz       Quasi-peak
                                                     Peak        1MHz           3MHz           Peak
                            Above 1GHz
                                                     Peak        1MHz            10Hz         Average
                      Note: For fundamental frequency, RBW=5MHz, VBW=5MHz, Peak detector is for
                            PK value, RMS detector is for Average value.
     Limit:                                   Field strength                                   Measuremen
                                                                  Limit                              t
(Spurious Emissions        Frequency         (microvolt/meter                    Remark
                                                                (dBuV/m )
and band edge)                                       )                                         distance (m)
                           0.009MHz-
                                               2400/F(kHz)           -              -              300
                           0.490MHz
                           0.490MHz-
                                               24000/F(kHz)          -              -              30
                           1.705MHz
                        1.705MHz-30MHz               30              -              -              30
                         30MHz-88MHz                100                  40.0   Quasi-peak            3
                         88MHz-216MHz               150                  43.5   Quasi-peak            3
                        216MHz-960MHz               200                  46.0   Quasi-peak            3
                         960MHz-1GHz                500                  54.0   Quasi-peak            3
                          Above 1GHz                500                  54.0    Average              3
                      Note: 1) 15.35(b), Unless otherwise specified, the limit on peak radio frequency
                            emissions is 20dB above the maximum permitted average emission limit
                            applicable to the equipment under test. This peak limit applies to the total
                            peak emission level radiated by the device.
                            2) Emissions radiated outside of the specified frequency bands, except for
                            harmonics, shall be attenuated by at least 50 dB below the level of the
                            fundamental or to the general radiated emission limits in Section 15.209,


                                    Page:12 of 29


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                      Report No.: CQAS20190500392E-01

                               whichever is the lesser attenuation.
    Limit:                      Frequency            Limit (dBuV/m @3m)            Remark
(Field strength of the                                       94.0               Average Value
                           2400MHz-2483.5MHz
fundamental signal)                                          114.0               Peak Value


    Test Setup:




                                           Figure 1. Below 30MHz
                                                             150cm




               Figure 2. 30MHz to 1GHz                                    Figure 3. Above 1 GHz
Test Procedure:          a. 1) Below 1G: The EUT was placed on the top of a rotating table 0.8 meters
                            above the ground at a 3 meter semi-anechoic camber. The table was rotated 360
                            degrees to determine the position of the highest radiation.
                            2) Above 1G: The EUT was placed on the top of a rotating table 1.5 meters
                            above the ground at a 3 meter semi-anechoic camber. The table was rotated 360
                            degrees to determine the position of the highest radiation.
                            Note: For the radiated emission test above 1GHz:
                            Place the measurement antenna away from each area of the EUT determined to
                            be a source of emissions at the specified measurement distance, while keeping
                            the measurement antenna aimed at the source of emissions at each frequency
                            of significant emissions, with polarization oriented for maximum response. The
                            measurement antenna may have to be higher or lower than the EUT, depending
                            on the radiation pattern of the emission and staying aimed at the emission
                            source for receiving the maximum signal. The final measurement antenna
                            elevation shall be that which maximizes the emissions. The measurement


                                         Page:13 of 29


                                         Shenzhen Huaxia Testing Technology Co., Ltd
                                                             Report No.: CQAS20190500392E-01

                       antenna elevation for maximum emissions shall be restricted to a range of
                       heights of from 1 m to 4 m above the ground or reference ground plane.
                   b. The EUT was set 3 meters away from the interference-receiving antenna, which
                       was mounted on the top of a variable-height antenna tower.
                   c. The antenna height is varied from one meter to four meters above the ground to
                       determine the maximum value of the field strength. Both horizontal and vertical
                       polarizations of the antenna are set to make the measurement.
                   d. For each suspected emission, the EUT was arranged to its worst case and then
                       the antenna was tuned to heights from 1 meter to 4 meters (for the test
                       frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the
                       rotatable table was turned from 0 degrees to 360 degrees to find the maximum
                       reading.
                   e. The test-receiver system was set to Peak Detect Function and Specified
                       Bandwidth with Maximum Hold Mode.
                   f. If the emission level of the EUT in peak mode was 10dB lower than the limit
                       specified, then testing could be stopped and the peak values of the EUT would
                       be reported. Otherwise the emissions that did not have 10dB margin would be
                       re-tested one by one using peak, quasi-peak or average method as specified
                       and then reported in a data sheet.
                   g. Test the EUT in the lowest channel,the middle channel,the Highest channel
                   h. The radiation measurements are performed in X, Y, Z axis positioning for
                       Transmitting mode,And found the X axis positioning which it is worse case.
                   i. Repeat above procedures until all frequencies measured was complete.
Exploratory Test   Transmitting with FSK at lowest, middle and highest channel.
Mode:
Final Test Mode:   Pretest the EUT at Transmitting mode, For below 1GHz part, through pre-scan, the
                   worst case is the highest channel.
                   Only the worst case is recorded in the report.
Test Voltage:      DC3.0V
Test Results:      Pass




                                  Page:14 of 29


                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                            Report No.: CQAS20190500392E-01



 Measurement Data


Field Strength Of The Fundamental Signal


                  Meter                 Emission
     Frequency              Factor                 Limits     Over    Detector   Ant. Pol.
                 Reading                  Level
                                                                       Type
       (MHz)     (dBμV)      (dB)       (dBμV/m) (dBμV/m)     (dB)                 H/V

        2408        93.75    -9.02        84.73      114     -29.27    Peak         H

        2408        92.87    -9.02        83.85      94      -10.15    AVG          H

        2408        89.08    -9.02        80.06      114     -33.94    Peak         V

        2408        88.17    -9.02        79.15      94      -14.85    AVG          V

        2440        97.71    -8.96        88.75      114     -25.25    Peak         H

        2440        96.92    -8.96        87.96      94      -6.04     AVG          H

        2440        90.99    -8.96        82.03      114     -31.97    Peak         V

        2440        90.03    -8.96        81.07      94      -12.93    AVG          V

        2474      100.18     -8.74        91.44      114     -22.56    Peak         H

        2474        99.34    -8.74        90.60      94      -3.40     AVG          H

        2474        92.59    -8.74        83.85      114     -30.15    Peak         V

        2474        91.86    -8.74        83.12      94      -10.88    AVG          V




                                     Page:15 of 29


                                         Shenzhen Huaxia Testing Technology Co., Ltd
                                                        Report No.: CQAS20190500392E-01



Spurious Emissions
30MHz~1GHz (the worst case)
Test mode:            Transmitting (Highest channel)    Vertical




                                  Page:16 of 29


                                         Shenzhen Huaxia Testing Technology Co., Ltd
                                                        Report No.: CQAS20190500392E-01


30MHz~1GHz (the worst case)
Test mode:            Transmitting (Highest channel)    Horizontal




                                  Page:17 of 29


                                       Shenzhen Huaxia Testing Technology Co., Ltd
                                                            Report No.: CQAS20190500392E-01


Above 1GHz
Test mode:             Transmitting              Test channel:            Lowest
              Meter                 Emission                                         Ant. Pol.
Frequency    Reading    Factor       Level        Limits         Over     Detector
  (MHz)      (dBμV)      (dB)       (dBμV/m) (dBμV/m)            (dB)      Type        H/V
   4816       47.21      -1.24        45.97         74           -28.03     Peak        H
   4816       33.45      -1.24        32.21         54           -21.79     AVG         H
   7224       51.65      5.98         57.63         74           -16.37     Peak        H
   7224       35.94      5.98         41.92         54           -12.08     AVG         H
   4816       50.46      -1.24        49.22         74           -24.78     peak        V
   4816       34.79      -1.24        33.55         54           -20.45     AVG         V
   7224       48.6       5.98         54.58         74           -19.42     peak        V
   7224       35.23      5.98         41.21         54           -12.79     AVG         V
Test mode:             Transmitting              Test channel:            Middle
              Meter                 Emission                                         Ant. Pol.
Frequency    Reading    Factor       Level        Limits         Over     Detector
  (MHz)      (dBμV)      (dB)       (dBμV/m) (dBμV/m)            (dB)      Type        H/V
   4880       50.66      -0.82        49.84         74           -24.16     peak        H
   4880       36.49      -0.82        35.67         54           -18.33     AVG         H
   7320       51.33      5.91         57.24         74           -16.76     peak        H
   7320       37.24      5.91         43.15         54           -10.85     AVG         H
   4880       48.66      -0.82        47.84         74           -26.16     peak        V
   4880       34.79      -0.82        33.97         54           -20.03     AVG         V
   7320       49.21      5.91         55.12         74           -18.88     peak        V
   7320       36.23      5.91         42.14         54           -11.86     AVG         V
Test mode:             Transmitting              Test channel:            Highest
              Meter                 Emission                                         Ant. Pol.
Frequency    Reading    Factor       Level        Limits         Over     Detector
  (MHz)      (dBμV)      (dB)       (dBμV/m) (dBμV/m)            (dB)      Type        H/V
   4948       51.91      -0.49        51.42         74           -22.58     peak        H
   4948       36.47      -0.49        35.98         54           -18.02     AVG         H
   7422       51.67      5.74         57.41         74           -16.59     peak        H
   7422       39.47      5.74         45.21         54           -8.79      AVG         H
   4948       49.25      -0.49        48.76         74           -25.24     peak        V
   4948       34.87      -0.49        34.38         54           -19.62     AVG         V
   7422       48.64      5.74         54.38         74           -19.62     peak        V
   7422       35.49      5.74         41.23         54           -12.77     AVG         V

                                 Page:18 of 29


                                              Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190500392E-01




Remark:
1) The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
   equation with a sample calculation is as follows:
   Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor

2) Scan from 9kHz to 25GHz,The disturbance above 10GHz and below 30MHz was very low, and the
   above harmonics were the highest point could be found when testing, so only the above harmonics
   had been displayed. The amplitude of spurious emissions from the radiator which are attenuated
   more than 20dB below the limit need not be reported .




                                       Page:19 of 29


                                             Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190500392E-01




6.3 Restricted bands around fundamental frequency
Test Requirement:          47 CFR Part 15C Section 15.249 (d), 15.209 and 15.205;
Test Method:               ANSI C63.10 :2013
Test Site:                 Measurement Distance: 3m (Semi-Anechoic Chamber)
                           Emissions radiated outside of the specified frequency bands, except for
Limit(Band Edge):          harmonics, shall be attenuated by at least 50 dB below the level of the
                           fundamental or to the general radiated emission limits in Section 15.209,
                           whichever is the lesser attenuation.
                                   Frequency            Limit (dBµV/m @3m)            Remark
                                                                                    Quasi-peak
                                 30MHz-88MHz                    40.0
                                                                                      Value
                                                                                    Quasi-peak
                                88MHz-216MHz                    43.5
                                                                                      Value
                                                                                    Quasi-peak
                               216MHz-960MHz                    46.0
                                                                                      Value
                                                                                    Quasi-peak
                                 960MHz-1GHz                    54.0
                                                                                      Value
                                                                54.0              Average Value
                                  Above 1GHz
                                                                74.0                Peak Value
Test Setup:




          Figure 1. 30MHz to 1GHz                                   Figure 2. Above 1 GHz
                        Below 1GHz test procedure as below:
Test Procedure:         j. The EUT was placed on the top of a rotating table 0.8 meters above the
                              ground at a 3 meter semi-anechoic camber. The table was rotated 360
                              degrees to determine the position of the highest radiation.
                           k. The EUT was set 3 meters away from the interference-receiving antenna,
                              which was mounted on the top of a variable-height antenna tower.
                           l. The antenna height is varied from one meter to four meters above the ground
                              to determine the m aximum value of the field strength. Both horizontal and
                              vertical polarizations of the antenna are set to make the measurement.
                           m. For each suspected emission, the EUT was arranged to its worst case and
                              then the antenna was tuned to heights from 1 meter to 4 meters (for the test
                              frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the
                              rotatable table was turned from 0 degrees to 360 degrees to find the
                              maximum reading.


                                      Page:20 of 29


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                    Report No.: CQAS20190500392E-01

                            n.   The test-receiver system was set to Peak Detect Function and Specified
                                 Bandwidth with Maximum Hold Mode.
                            o.   If the emission level of the EUT in peak mode was 10dB lower than the limit
                                 specified, then testing could be stopped and the peak values of the EUT
                                 would be reported. Otherwise the emissions that did not have 10dB margin
                                 would be re-tested one by one using peak, quasi-peak or average method as
                                 specified and then reported in a data sheet.
                            Above 1GHz test procedure as below:
                            p.   Different between above is the test site, change from Semi - Anechoic
                                 Chamber to fully Anechoic Chamber and change form table 0.8 metre to 1.5
                                 metre( Above 18GHz the distance is 1 meter and table is 1.5 metre).
                            q.   Test the EUT in the lowest channel , the Highest channel
                            r.   The radiation measurements are performed in X, Y, Z axis positioning for
                                 Transmitting mode, and found the X axis positioning which it is worse case.
                            s.   Repeat above procedures until all frequencies measured was complete.
 Test Mode:                 Transmitting with FSK at lowest, middle and highest channel.
 Test Voltage:              DC5.0V form PC
 Test Results:              Pass


Test plot as follows:
Test mode:       Transmitting     Test channel:    Lowest            Remark:          Vertical




                                        Page:21 of 29


1P ES WF M

                   Read                            Limit   over
           Freq   Level Factor       Level          Line   Llimit Remark   Pol/Phase

           MHz     dBuVy   d3/m dBuV/m dBuVv/m                dB

 1      2310.00   49.01    —9.25     39.76         74.00 —34.24 Peak       VERTICAL
 2 pp   2400.00   50.17    —9.10     41.07         74.00 —32.93 Peak       VERTICAL




                                   fgc ic <0   >


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                     Report No.: CQAS20190500392E-01



Test mode:   Transmitting   Test channel:   Lowest      Remark:        Horizontal




                                Page:23 of 29


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQAS20190500392E-01



Test mode:   Transmitting   Test channel:   Highest      Remark:        Vertical




                                Page:24 of 29


                                              Shenzhen Huaxia Testing Technology Co., Ltd
                                                                  Report No.: CQAS20190500392E-01



Test mode:       Transmitting      Test channel:    Highest           Remark:           Horizontal




Remark:
   The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
   equation with a sample calculation is as follows:
   Final Test Level =Receiver Reading - Correct Factor
   Correct Factor = Preamplifier Factor– Antenna Factor–Cable Factor




                                       Page:25 of 29


                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                                          Report No.: CQAS20190500392E-01




6.4 20dB Bandwidth
     Test Requirement:   47 CFR Part 15C Section 15.215
     Test Method:        ANSI C63.10:2013
     Test Setup:




     Test Mode:          Transmitting with FSK at lowest, middle and highest channel.
     Limit:              N/A
     Test Results:       Pass


Measurement Data
        Test channel             20dB bandwidth (MHz)                       Results
              Lowest                     2.1085                              Pass
              Middle                     2.1274                              Pass
              Highest                    2.1187                              Pass




                                Page:26 of 29


                                        Shenzhen Huaxia Testing Technology Co., Ltd
                                                       Report No.: CQAS20190500392E-01



 Test plot as follows:
Test channel:            Lowest




                                  Page:27 of 29


                                Shenzhen Huaxia Testing Technology Co., Ltd
                                               Report No.: CQAS20190500392E-01



Test channel:   Middle




Test channel:   Highest




                          Page:28 of 29



Document Created: 2019-06-10 00:25:41
Document Modified: 2019-06-10 00:25:41

© 2024 FCC.report