MPE Report

FCC ID: 2AAC6-C10

RF Exposure Info

Download: PDF
FCCID_3977525

                                                           RF Exposure Report

                       Report No.: SA180626C38

                            FCC ID: 2AAC6-C10

                       Test Model: AUT-450C

                 Received Date: Jun. 26, 2018

          Date of Evaluation: Aug. 03, 2018

                     Issued Date: Aug. 06, 2018


                         Applicant: Automatic Labs, Inc.

                          Address: 128 KING ST, 3RD FLOOR, SAN FRANCISCO CA 94107



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Vil, Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan (R.O.C)
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: SA180626C38                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Antenna Gain ...................................................................................................................................... 5
    2.5      Calculation Result Of Maximum Conducted Power ............................................................................ 6




Report No.: SA180626C38                                              Page No. 2 / 6                                              Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA180626C38           Original Release                                   Aug. 06, 2018




Report No.: SA180626C38                     Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: OBD2 dongle

              Brand: Automatic Labs

        Test Model: AUT-450C

    Sample Status: Production Unit

          Applicant: Automatic Labs, Inc.

Date of Evaluation: Aug. 03, 2018

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




     Prepared by :                                               ,   Date:      Aug. 06, 2018
                                 Evonne Liu / Specialist




     Approved by :                                               ,   Date:      Aug. 06, 2018
                             Dylan Chiou / Project Engineer




Report No.: SA180626C38                         Page No. 4 / 6                       Report Format Version: 6.1.1


2      RF Exposure

2.1      Limits for Maximum Permissible Exposure (MPE)

    Frequency Range            Electric Field     Magnetic Field       Power Density      Average Time
                                                                                2
         (MHz)                Strength (V/m)      Strength (A/m)         (mW/cm )           (minutes)
                               Limits For General Population / Uncontrolled Exposure
        0.3-1.34                   614                  1.63               (100)*                30
                                                                                  2
         1.34-30                  824/f                2.19/f             (180/f )*              30
         30-300                    27.5                0.073                0.2                  30
        300-1500                    …                    …                 f/1500                30
      1500-100,000                  …                    …                  1.0                  30

f = Frequency in MHz ; *Plane-wave equivalent power density



2.2      MPE Calculation Formula

                          2
Pd = (Pout*G) / (4*pi*r )
where
                                   2
Pd = power density in mW/cm
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3      Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
         So, this device is classified as Mobile Device.




2.4      Antenna Gain

BT/WLAN: metal antenna with 1.08 dBi gain
LTE Band 2: metal antenna with 3.6 dBi gain
LTE Band 4: metal antenna with 3.25 dBi gain
LTE Band 12: metal antenna with 2.88 dBi gain




Report No.: SA180626C38                            Page No. 5 / 6                       Report Format Version: 6.1.1


2.5     Calculation Result of Maximum Conducted Power

                Frequency Band    Max Power      Antenna Gain   Distance   Power Density       Limit
      Band                                                                          2                2
                    (MHz)           (dBm)            (dBi)        (cm)       (mW/cm )        (mW/cm )
      LTE 2        1850-1910        24.22               3.6       20          0.120              1.00

      LTE 4        1710-1755        24.24              3.25       20          0.112              1.00

      LTE 12        699-716         24.45              2.88       20          0.108              0.47

      WLAN         2412-2462        16.23              1.08       20          0.011              1.00

       BT          2402-2480            5.95           1.08       20          0.001              1.00



Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


WWAN +WLAN + BT = 0.120 + 0.011 + 0.001 = 0.132
Therefore the maximum calculations of above situations are less than the “1” limit.



--- END ---




Report No.: SA180626C38                        Page No. 6 / 6                    Report Format Version: 6.1.1



Document Created: 2018-08-09 17:38:36
Document Modified: 2018-08-09 17:38:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC