                 Maximum Permissible Exposure Evaluation


An estimation of MPE in this application for product is used to ensure if it complies to the

rules of the standard in the regulation list above.

Maximum permissible exposure (MPE) refers to the RF energy that is acceptable for

human exposure. It is broken down into two categories, Occupational/controlled and

General population/uncontrolled.

Occupational/controlled limits apply in situations in which persons are exposed as a

consequence of their employment provided those persons are fully aware of the potential

for   exposure    and    can   exercise    control    over   their   exposure.   Limits   for

occupational/controlled exposure also apply in situations when an individual is transient

through a location where occupational/controlled limits apply provided he or she is made

aware of the potential for exposure.

General population/uncontrolled exposures apply in situations in which the general public

may be exposed, or in which persons that are exposed as a consequence of their

employment may not be fully aware of the potential for exposure or can not exercise

control over their exposure.

We analysis if it comply with the limits for General population/uncontrolled exposure. The

FCC’s MPE limits for field strength and power density are given in 47CFR 1.1310(Table

below).These limits are generally based on recommended exposure guidelines published

by the National Council on Radiation Protection and Measurements (NCRP), and also

partly based on guidelines recommended by the American National Standards Institute

(ANSI) in Section 4.1 of ANSI/IEEE C95.1.


                Table: Limits For Maximum Permissible Exposure (MPE)

                     (A) Limits for Occupational/controlled Exposure

                                                            Power         Averaging Time
 Frequency       Electric Field      Magnetic Field
                                                            Density      (minute)|E|2,|H|2 or
Range(MHz)     Strength(E)(V/m)     Strength(H)(A/m)
                                                         (S)(mW/cm2)              S

   0.3-3.0             614               1.63               (100)*               6

   3.0-30             1842/f             4.89/f            (900/f2)*             6

   30-300              61.4              0.163                1.0                6

  300-1500              --                 --                f/300               6

1500-100,000            --                 --                  5                 6

               (B) Limits for General Population/uncontrolled Exposure

                                                            Power         Averaging Time
 Frequency       Electric Field      Magnetic Field
                                                            Density      (minute)|E|2,|H|2 or
Range(MHz)     Strength(E)(V/m)     Strength(H)(A/m)
                                                         (S)(mW/cm2)              S

  0.3-1.34             614               1.63               (100)*               30

   1.34-30            824/f              2.19/f             (180/f)*             30

   30-300              27.5              0.073                0.2                30

  300-1500              /                  /                f/1500               30

1500-100,000            /                  /                  1.0                30

f=frequency in MHz                                     *Plane-wave equivalent power density

A rough estimation of the expected exposure in power flux density on a given point can be

made with the following equation:


                            P*G
                         S=
                           4π*R2

Where:

    S = power density

    P = power input to the antenna

    G = numeric gain of the antenna in the direction of interest relative to an isotropic

radiator


      R= distance to the centre of radiation of the antenna

      EIRP = P*G


 The antenna of the product, under normal use condition is at least 20 cm away
 from the body of the user. Warning statement to the user for keeping at least
 20cm separation distance and the prohibition of operating to a person has been
 printed on the user’s manual. Therefore, the S of the device is calculated with
 R=20cm, and if it is below the limit S, then we can conclude the device complies
 with the rules.



 The worst case (refer to report WSCT-R&E-19020023A-RX (FCC) ) is below:
 Antenna 1 gain: 2.65dBi, numeric gain is 1.84
 Antenna 2 gain: 2.65dBi, numeric gain is 1.84
 Equipment’s working frequency is: 2406~2474MHz


 For ANT1:


     Pmax*            Pmax            R                  S       MPE Limit
                                                                             Conclusion
     (dBm)            (mW)           (cm)         (mW/cm )   2
                                                                 (mW/cm2)

    16.52          44.87        20         0.0164             1.00           PASS
                   87 91
 Note:*- based on the maximum tune-up tolerance limit declared by manufacturer.

0.0164<1.00

So the SAR report is not required.



 For ANT2:


     Pmax*            Pmax            R                  S       MPE Limit
                                                                             Conclusion
     (dBm)            (mW)           (cm)         (mW/cm )   2
                                                                 (mW/cm2)

    16.64             46.13           20            0.0169          1.00        PASS
 Note:*- based on the maximum tune-up tolerance limit declared by manufacturer.

0.0169<1.00

So the SAR report is not required.