Test Report

FCC ID: 2AABK-TM800W630L

Test Report

Download: PDF
FCCID_3366889

                                                                                                      REPORT No.:SZ16120122E01




                               FCC TEST REPORT


     APPLICANT                        :        Shenzhen Chuangwei Electronic Appliance Tech Co., Ltd.

     PRODUCT NAME                     :        Tablet PC

     MODEL NAME                       :        TM800W630L, CT811, H811

     TRADE NAME                       :        Nuvision, Tmax

     BRAND NAME                       :        Nuvision

     FCC ID                           :        2AABK-TM800W630L

     STANDARD(S)                      :        47 CFR Part 15 Subpart B

     TEST DATE                        :        2017-03-20 to 2017-03-29

     ISSUE DATE                       :        2017-03-30




             SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.




NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.



MORLAB GROUP
                                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn


                                                                                                        REPORT No.:SZ16120122E01



                                                               DIRECTORY

 1. TECHNICAL INFORMATION∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5


 1.1. APPLICANT INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
 1.2. EQUIPMENT UNDER TEST (EUT) DESCRIPTION∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5


 2. TEST RESULTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7


 2.1. APPLIED REFERENCE DOCUMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7


 3. TEST CONDITIONS SETTING ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8


 3.1. TEST MODE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
 3.2. TEST SETUP AND EQUIPMENTS LIST∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9
 3.2.1. CONDUCTED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9
 3.2.2. RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10


 4. 47 CFR PART 15B REQUIREMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12


 4.1. CONDUCTED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12
 4.1.1. REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12
 4.1.2. TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12
 4.1.3. TEST RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12
 4.2. RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15
 4.2.1. REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15
 4.2.2. TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15
 4.2.3. FREQUENCY RANGE OF MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15
 4.2.4. TEST RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16


 ANNEX A TEST SETUP PHOTOS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 19


 ANNEX B TEST UNCERTAINTY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21


 ANNEX C TESTING LABORATORY INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22




MORLAB GROUP
                                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                  Page2 0f 22


                                                                                                      REPORT No.:SZ16120122E01


 1.         IDENTIFICATION OF THE RESPONSIBLE TESTING LABORATORY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22
 2.         IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙22
 3.         ACCREDITATION CERTIFICATE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22
 4.         TEST ENVIRONMENT CONDITIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22




                                                               Change History
  Issue                 Date                                                       Reason for change
      1.0          2017-03-30                                                            First edition




MORLAB GROUP
                                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                Page3 0f 22


                                                                                     REPORT No.:SZ16120122E01



                             Test Report Declaration

  Applicant                  Shenzhen Chuangwei Electronic Appliance Tech Co., Ltd.
                             4/F,6/F South, Skyworth Industrial Park, Shiyan Bao'an
  Applicant Address
                             District, Shenzhen, Guangdong
  Manufacturer               Shenzhen Chuangwei Electronic Appliance Tech Co., Ltd.
                             4/F,6/F South, Skyworth Industrial Park, Shiyan Bao'an
  Manufacturer Address
                             District, Shenzhen, Guangdong
  Product Name               Tablet PC

  Model Name                 TM800W630L, CT811, H811

  Brand Name                 Nuvision

  HW Version                 V1.0

  SW Version                 Windows 10

  Test Standards             47 CFR Part 15 Subpart B

  Test Result                PASS




              Reviewed by       :
                                                            Xiao Xiong


              Approved by       :
                                                             Andy Yeh




MORLAB GROUP
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page4 0f 22


                                                                                            REPORT No.:SZ16120122E01



 1. Technical Information
 Note: Provided by applicant


 1.1. Applicant Information
  Company:           Shenzhen Chuangwei Electronic Appliance Tech Co., Ltd.
  Address:           4/F,6/F South, Skyworth Industrial Park, Shiyan Bao'an District, Shenzhen,
                     Guangdong


 1.2. Equipment under Test (EUT) Description
                   EUT Type: Tablet PC
                    Serial No: (N/A, marked #1 by test site)
         Hardware Version: V1.0
          Software Version: Windows 10
                Power supply: Battery
                                 Brand Name:                        N/A
                                 Model No.:                         EL-24110110PV
                                 Serial No.:                        (N/A, marked #1 by test site)
                                 Capacity:                          3700mAh
                                 Rated Voltage:                     3.8V
                                 Charge Limit:                      4.35V
       Ancillary Equipment: AC Adapter (Charger for Battery)
                                 Brand Name:                        N/A
                                 Model No.:                         A68-502000
                                 Serial No.:                        (N/A, marked #1 by test site)
                                 Rated Input:                           100-240V, 50/60Hz, 350mA
                                 Rated Output:                           5V, 2.0A

 NOTE:

  1.    The EUT is a Tablet PC which supports ISM 2.4GHz Bluetooth band and WIFI (802.11b/g/n)

        band.

  2.    It is equipped with a Micro-B USB port and a HDMI port which can be connected to the

        ancillary equipments.




MORLAB GROUP
                                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page5 0f 22


                                                                                        REPORT No.:SZ16120122E01


 3.   For a more detailed description, please refer to specification or user’s manual supplied by the

      applicant and/or manufacturer.




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page6 0f 22


                                                                                         REPORT No.:SZ16120122E01



 2. Test Results
 2.1. Applied Reference Documents
 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

         No.    Identity                                          Document Title
         1      47 CFR Part 15                                    Radio Frequency Devices

 Test detailed items/section required by FCC rules and results are as below:

         No.   Section     Description                           Test Date                                          Result
         1     15.107      Conducted Emission                    2017.03.23                                         PASS
         2     15.109      Radiated Emission                     2016.03.26                                         PASS

 NOTE: The tests were performed according to the method of measurements prescribed in ANSI
 C63.4-2014.




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page7 0f 22


                                                                                       REPORT No.:SZ16120122E01



 3.     Test Conditions Setting
 3.1. Test Mode

 1        The first test mode (Data Transmitting)
          The EUT configuration of the emission tests is EUT + Battery + AC adapter + PC.
          In this test mode, the EUT with a T-Flash Card embedded was connected to a PC via
          the Micro-B USB port. During the measurement, the data is transmitting between the
          PC and the T-Flash Card of the EUT.
 2        The second test mode (HDMI)
          The EUT configuration of the emission tests is EUT + Battery + AC adapter +
          Television .
          During the measurement, the EUT was connected to the AC adapter and the
          Television, the Television was connected with the EUT via the HDMI port, meanwhile,
          the EUT was working normally as an intentional device.
 Note: All test modes are performed, only the worse case (HDMI) is recorded in this report.




MORLAB GROUP
                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page8 0f 22


                                                                                            REPORT No
                                                                                                    o.:SZ1612
                                                                                                            20122E01



 3.2. Te
       est Setu
              up and Equipm
                          ments Liist

 3.2.1. Conducte
               ed Emission
 A. Test Setup:
         S




 The EUT iss placed on a 0.8m high  h insulating
                                               g table, whicch stands onn the grounded conduc  cting floor,
 and keeps 0.4m awayy from the grounded conducting
                                                c            wall. The EUT
                                                                        E     is con
                                                                                   nnected to the
                                                                                               t     power
 mains throough a LIS  SN which provides
                                    p          0Ω/50µH off coupling impedance
                                              50                                    e for the measuring
                                                                                               m
 instrument.. A Pulse Liimiter is use
                                    ed to protecct the meas suring instru
                                                                        ument. The e factors of the whole
 test system
           m are calibraated to corre
                                    ect the read
                                               ding.
 The power strip or extension cord  d has been investigated  d to make sure
                                                                        s    that the
                                                                                    e LISN integgrity inma
 intained witth respect to the impeddance chara acteristics as
                                                            a prescribeed in ANSI C C63.4-2014 4         at
 Clause 4.3.

 B. Equip
        pments Lis
                 st:

    Descrip
          ption        M
                       Manufactur
                                rer                    Model                     Serial No
                                                                                         o.          Cal. D
                                                                                                          Date              Du
                                                                                                                             ue. Date
      Receivver             Narda                   PMM
                                                      M 9010                  595WX110
                                                                                     007             2016.0
                                                                                                          06.02             2017.06.01
        LISN
           N            S
                        Schwarzbec
                                 ck                NSL
                                                     LK 8127                       812744            2016.0
                                                                                                          06.02             2017.06.01
   Pulse Lim
           miter
                            VTSD                       95
                                                        561D                          9537           2016.0
                                                                                                          07.05             2017.07.04
      (20dB
          B)




MORLAB
M    B GROU
          UP
                               FL1-3, Bu
                                       uilding A, FeiYang Sccience Park, No.8 LongChang Road,        Tel: 86-755-36698555   Fax:: 86-755-36698525
                               Block67, BaoAn District, She
                                                          enZhen , GuangDon
                                                                          ng Province, P. R. China
                                                                                             C       Http://www
                                                                                                              w.morlab.cn   E-mail: service@morlab..cn

                                                                                                                                     Page9 0f 22


                                                                                      REPORT No.:SZ16120122E01



 3.2.2. Radiated Emission

 A. Test Setup:
    1.   For radiated emissions from 30MHz to1GHz




    2.   For radiated emissions above 1GHz




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page10 0f 22


                                                                                         REPORT No.:SZ16120122E01


 The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
 the site (factors) is calculated to correct the reading.The EUT is placed on a 0.8m high insulating
 Turn Table, and keeps 3m away from theTest Antenna, which is mounted onavariable-height
 antenna master tower.

 For the test Antenna:

 In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn
 TestAntenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna
 height is varied from 1m to 4m above the ground to determine the maximum value of the field
 strength. The emission levels at both horizontal and vertical polarizations should be tested.

 B. Equipments List:

    Description          Manufacturer                 Model                   Serial No.           Cal. Date              Due. Date
 MXE EMI Receiver           Agilent                  N9038A                MY54130016 2016.06.03                          2017.06.02
   Semi-Anechoic
                          Changning               9m*6m*6m                          N/A            2017.01.11             2018.01.10
     Chamber
   Test Antenna -
                         Schwarzbeck              VULB 9163                    9163-274            2016.12.09             2017.12.08
       Bi-Log
   Test Antenna -
                         Schwarzbeck             BBHA9120C                   9120C-384             2016.07.05             2017.07.04
        Horn




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page11 0f 22


                                                                                          REPORT No.:SZ16120122E01




 4.       47 CFR Part 15B Requirements
 4.1. Conducted Emission

 4.1.1. Requirement

 According to FCC section 15.107, the radio frequency voltage that is conducted back onto the
 ACpower line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in
 thefollowing table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

      Frequency range                                            Conducted Limit (dBµV)
           (MHz)                              Quasi-peak                                                  Average
         0.15 - 0.50                              66 to 56                                                 56 to 46
          0.50 - 5                                    56                                                        46
           5 - 30                                     60                                                        50
 NOTE:
 a) The limit subjects to the Class B digital device.
 b) The lower limit shall apply at the band edges.
 c)   The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.


 4.1.2. Test Description

 See section 3.2.1 of this report.


 4.1.3. Test Result

 The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and
 Average (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow
 margins from the AV and QP limits will be re-measured with AV and QP detectors.Tests for both L
 phase and N phase lines of the power mains connected to the EUT are performed. All test modes
 are considered, refer to recorded points and plots below.

 A. Test Plot and Suspicious Points:




MORLAB GROUP
                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page12 0f 22


                                                                                      REPORT No.:SZ16120122E01




                                              (Plot A: L Phase)



        Fre.    Emission Level (dBµV)                           Limit (dBµV)
  No.                                                                                           Power-line              Verdict
        (MHz)   Quai-peak           Average            Quai-peak              Average
   1    0.15      52.46               22.38                66.00                56.00                                   PASS
   2    0.805     47.16               29.89                56.00                46.00                                   PASS
   3    0.88      48.84               32.41                56.00                46.00                                   PASS
                                                                                                   Line
   4    3.19      46.07               32.54                56.00                46.00                                   PASS
   5    3.32      50.68               38.98                56.00                46.00                                   PASS
   6    4.02      52.70               39.37                56.00                46.00                                   PASS




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,          Tel: 86-755-36698555   Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page13 0f 22


                                                                                        REPORT No.:SZ16120122E01




                                               (Plot B: N Phase)



          Fre.    Emission Level (dBµV)                         Limit (dBµV)
    No.                                                                                           Power-line               Verdict
          (MHz)   Quai-peak          Average           Quai-peak              Average
     1    0.15      56.35              17.34               66.00                56.00                                      PASS
     2    0.795     48.12              29.22               56.00                46.00                                      PASS
     3    0.875     48.69              30.74               56.00                46.00                                      PASS
                                                                                                   Neutral
     4    1.035     46.30              32.44               56.00                46.00                                      PASS
     5    3.32      49.72              35.68               56.00                46.00                                      PASS
     6    4.355     51.38              31.08               56.00                46.00                                      PASS

 Result: Pass




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,           Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                    Page14 0f 22


                                                                                          REPORT No.:SZ16120122E01



 4.2. Radiated Emission


 4.2.1. Requirement

 According to FCC section 15.109 (a), the field strength of radiated emissions from
 unintentionalradiators at a distance of 3 meters shall not exceed the following values:

               Frequency         Field Strength Limitation at 3m Measurement Dist
              range (MHz)                      (µV/m)                                         (dBµV/m)
               30.0 - 88.0                        100                                         20log 100
              88.0 - 216.0                        150                                         20log 150
              216.0 - 960.0                       200                                         20log 200
              Above 960.0                         500                                         20log 500

 As shown in FCCsection 15.35(b), for frequencies above 1000MHz, the field strength limits are
 based on average detector. When average radiated emission measurements are specified in this
 part, including emission measurements below 1000MHz, there also is a limit on the radio
 frequency emissions, as measured using instrumentation with a peak detector function,
 corresponding to 20dB above the maximum permitted average limit for the frequency being
 investigated unless a different peak emission limit is otherwise specified in the rules.

 Note:

 1)   The tighter limit shall apply at the boundary between two frequency range.
 2)   Limitation expressed in dBµV/m is calculated by 20log Emission Level(µV/m).


 4.2.2. Test Description

 See section 3.2.2 of this report.


 4.2.3. Frequency range of measurement

 According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the
 following table:




MORLAB GROUP
                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page15 0f 22


                                                                                         REPORT No.:SZ16120122E01




 4.2.4. Test Result

 The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
 more than the limits, and that have narrow margins from the limits will be re-measured with AV and
 QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
 to perform the tests. All test modes are considered, refer to recorded points and plots below.

 The amplitude of spurious emissions (6GHz-12.5GHz) which are attenuated more than 20 dB
 below the permissible value need not be reported.

 Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
 test condition was recorded in this test report.




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page16 0f 22


                                                                                         REPORT No.:SZ16120122E01


 A. Test Plots and Suspicious Points:




                      (Plot A: 30MHz – 6GHz, Test Antenna Vertical)


   No.     Fre.       Pk            QP                AV           Limit-PK          Limit-QP      Limit-AV          ANT            Verdict
           MHz      dBµV/m      dBµV/m            dBµV/m           dBµV/m             dBµV/m        dBµV/m
   1      59.100     N.A.         35.25             N.A.              N.A.              40.00         N.A.                V         PASS
   2     148.340     N.A.         29.21             N.A.              N.A.              43.50         N.A.                V         PASS
   3     445.160     N.A.         39.59             N.A.              N.A.              46.00         N.A.                V         PASS
   4     593.570     N.A.         39.40             N.A.              N.A.              46.00         N.A.                V         PASS
   5     1739.733   50.41          N.A.            44.09             74.00               N.A.        54.00                V         PASS
   6     4450.880   49.18          N.A.            43.45             74.00               N.A.        54.00                V         PASS




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555       Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn       E-mail: service@morlab.cn

                                                                                                                                      Page17 0f 22


                                                                                        REPORT No.:SZ16120122E01




                    (Plot B: 30MHz – 6GHz, Test Antenna Horizontal)


  No.     Fre.       Pk             QP                AV           Limit-PK          Limit-QP       Limit-AV          ANT        Verdict
          MHz      dBµV/m       dBµV/m            dBµV/m           dBµV/m             dBµV/m         dBµV/m
   1     51.340     N.A.          25.82             N.A.              N.A.              40.00          N.A.               H       PASS
   2    148.340     N.A.          29.66             N.A.              N.A.              43.50          N.A.               H       PASS
   3    445.160     N.A.          38.22             N.A.              N.A.              46.00          N.A.               H       PASS
   4    741.980     N.A.          38.27             N.A.              N.A.              46.00          N.A.               H       PASS
   5    890.390     N.A.          37.97             N.A.              N.A.              46.00          N.A.               H       PASS
   6    1559.467   47.06           N.A.             41.57            74.00                  N.A.      54.00               H      PASS

 Result: Pass




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,          Tel: 86-755-36698555   Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page18 0f 22


                                                                                  REPORT No.:SZ16120122E01



 Annex A      Test Setup Photos
 1. Conducted emission main’s port front view




 2. Conducted emission main’s port side view




MORLAB GROUP
                      FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                      Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                           Page19 0f 22


                                                                                REPORT No.:SZ16120122E01


 3. Radiated emission (30MHz-1GHz)




 4. Radiated emission (above 1GHz)




MORLAB GROUP
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                         Page20 0f 22


                                                                                       REPORT No.:SZ16120122E01



 Annex B         Test Uncertainty
 The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
 Uncertainty in Measurement" (GUM) published by ISO.
 Uncertainty of Conducted Emission:            ±1.8dB
 Uncertainty of Radiated Emission:             ±3.1dB




MORLAB GROUP
                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page21 0f 22


                                                                                        REPORT No.:SZ16120122E01



 Annex C          Testing Laboratory Information

 1. Identification of the Responsible Testing Laboratory
  Company Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                               Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China
  Responsible Test Lab Manager:             Mr. Su Feng
  Telephone:                                +86 755 36698555
  Facsimile:                                +86 755 36698525


 2. Identification of the Responsible Testing Location

  Name:                                     Shenzhen Morlab Communications Technology Co., Ltd.
                                            Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China


 3. Accreditation Certificate
  Accredited Testing Laboratory:            The FCC registration number is 695796.
                                            (Shenzhen Morlab Communications Technology Co., Ltd.)


 4. Test Environment Conditions
 During the measurement, the environmental conditions were within the listed ranges:

  Temperature (°C):                              15 - 35
  Relative Humidity (%):                         30 - 60
  Atmospheric Pressure (kPa):                    86 - 106



                                     ***** END OF REPORT *****




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page22 0f 22



Document Created: 2017-04-20 09:31:42
Document Modified: 2017-04-20 09:31:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC