Test Report

FCC ID: 2AAA6-S125

Test Report

Download: PDF
FCCID_3075554

                                                  FCC REPORT
Report Reference No. .................... :               TRE1606013303                    R/C…….: 90320

FCC ID ............................................. :    2AAA6-S125

Applicant’s name ........................... :            SENWA MEXICO,S.A.DE C.V
                                                          Av. Javier Barros Sierra 540,Torre I, Piso 5; COL. LOMAS DE
Address.............................................:
                                                          SANTA FE DELEGACION ALVARO OBREGON C.P. 01210
                                                          MEXICO,DISTRITO FEDERAL
Manufacturer......................................:       Senwa Mobile HK ltd
                                                          Room 910, International Trade Centre 11-19 Sha Tsui Road,
Address...............................................:
                                                          Tsuen Wan, NT, HK
Test item description .................... :              Mobile Phone

Trade Mark ....................................... :      SENWA

Model/Type reference ....................... :            S125

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B - Unintentional Radiators
                                                          ANSI C63.4: 2014
Date of receipt of test sample………..:                      June 23, 2016

Date of testing…………………………:                                June 24, 2016 – July 06, 2016

Date of issue…………………………...:                               July 06, 2016

Result .................. …………………...:                     Pass

Compiled by

( position+printed name+signature) .. :                   File administrators Shayne Zhu

Supervised by

( position+printed name+signature) .. :                   Project Engineer Lion Cai

Approved by

( position+printed name+signature) .. :                   RF Manager Hans Hu

Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd

Address.............................................:     1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
                                                          Tianliao, Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd is acknowledged as copyright owner and source
of the material. Shenzhen Huatongwei International Inspection Co., Ltd takes no responsibility for and
will not assume liability for damages resulting from the reader's interpretation of the reproduced material
due to its placement and context.

The test report merely corresponds to the test sample.
It is not permitted to copy extracts of these test result without the written permission of the test laboratory.


 Report No:   TRE1606013303             Page:   2 of 18   Issued:   2016-07-06




                                          Contents

1.     T EST STANDARD S AND TEST D ESCR IPTION                                       3

1.1.   Test Standards                                                            3
1.2.   Test Description                                                          3

2.     SUMMARY                                                                       4

2.1.   Client Information                                                        4
2.2.   Product Description                                                       4
2.3.   EUT operation mode                                                        5
2.4.   EUT configuration                                                         5
2.5.   Configuration of Tested System                                            6

3.     TEST ENVIRONMENT                                                              7

3.1.   Address of the test laboratory                                            7
3.2.   Test Facility                                                             7
3.3.   Environmental conditions                                                  8
3.4.   Statement of the measurement uncertainty                                  8
3.5.   Equipments Used during the Test                                           8

4.     TEST CONDITIONS AND RESULTS                                                   9

4.1.   Conducted Emissions Test                                                  9
4.2.   Radiated Emission Test                                                    12

5.     TEST SETUP PHOTOS OF THE EUT                                              16



6.     EXTERNAL AND INTERNAL PHOTOS OF THE EUT                                   18


 Report No:     TRE1606013303               Page:   3 of 18              Issued:   2016-07-06




1 . T EST STANDARDS AND TEST DESCRIPTION

1.1. Test Standards
The tests were performed according to following standards:

47 CFR FCC Part 15 Subpart B - Unintentional Radiators

ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Test Description
ReportSection                  Test Item                      FCC Rule                  Result
      4.1             Conducted Emissions Test                  15.107                  Pass
      4.2               Radiated Emission Test                  15.109                  Pass


 Report No:        TRE1606013303            Page:   4 of 18            Issued:    2016-07-06

2. SUMMARY

2.1. Client Information
Applicant:                   SENWA MEXICO,S.A.DE C.V
Address:                     Av. Javier Barros Sierra 540,Torre I, Piso 5; COL. LOMAS DE SANTA FE
                             DELEGACION ALVARO OBREGON C.P. 01210MEXICO,DISTRITO
                             FEDERAL
Manufacturer:                Senwa Mobile HK ltd
Address:                     Room 910, International Trade Centre 11-19 Sha Tsui Road, Tsuen Wan, NT,
                             HK
2.2. Product Description
Name of EUT                  Mobile Phone
Trade Mark:                  SENWA
Model No.:                   S125
Listed Model(s):             -

IMEI 1:                      359430070000365
Power supply:                DC 3.7V From internal battery
Adapter information:         Model: S125
                             Input: 100-240Va.c.,50-60Hz,0.15A
                             Output:5.0Vd.c.,500mA


 Report No:       TRE1606013303            Page:   5 of 18               Issued:    2016-07-06



2.3. EUT operation mode

         Test mode                       Playing Video                       PC Data Transfer

              1                                ■
              2                                                                     ■

Note:
1. ■ is operation mode.
Pre-scan above all test mode, found below test mode which it was worse case mode.
                      Test item                                   Test mode (Worse case mode)
                Conducted emission                                           Mode 2
                 Radiated emission                                           Mode 2


2.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:

● - supplied by the manufacturer

○ - supplied by the lab

                                         Length (m) :        /
                                         Shield :            /
                                         Detachable :        /
                                         Manufacturer :      /
                                         Model No. :         /


 Report No:       TRE1606013303              Page:   6 of 18             Issued:      2016-07-06



2.5. Configuration of Tested System

                                        Configuration of Tested System



                              Printer                      PC                        EUT



                                                                             Mouse
               AC 120V/60Hz
                                                         AC
                                                      120V/60Hz
                                   Display
                                                                     Keyboard




                                  Equipment Used in Tested System
                                    Model
No.   Equipment      Manufacturer               Serial No.      Length      shielded/unshielded    Notes
                                      No.
                                    DIMEN
1         PC            DELL         SION       1RNN42X            /                   /           DOC
                                     E520
2       Printer        ESPOn        C3990         C3990A           /                   /           DOC
                                   MO56U
3       Mouse           DELL                    G0E02SY7        1.00m              unshielded      DOC
                                      OA
                                            CN-OFC237-71618-
4       Display         DELL       1707FPt                         /                   /           DOC
                                                65G-AAKC
                                            CNRH65665890726
5      Keyboard         DELL         L100                          /                   /           DOC
                                                   009L
       USB Cable      ITALCOM
6                                  USB 2.0          N/A         0.80m              unshielded      N/A
      (EUT to PC)      GROUP
       USB Cable
7      (Printer to     Genshuo     USB 2.0              N/A       1.20m            unshielded      N/A
          PC)
8      Power line         /             /               N/A       1.00m            unshielded      N/A


 Report No:       TRE1606013303                 Page:    7 of 18                   Issued:   2016-07-06



3. TEST ENVIRONMENT

3.1. Address of the test laboratory
Laboratory:Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
3.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225
Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories
(identical to ISO/IEC17025: 2005 General Requirements) for the Competence of Testing and Calibration Labo
ratories, Date of Registration: February 28, 2015. Valid time is until February 27, 2018.

A2LA-Lab Cert. No. 3902.01
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for tec
hnical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005
General Requirements for the Competence of Testing and Calibration Laboratories and any additional progra
m requirements in the identified field of testing. Valid time is until December 31, 2016.

FCC-Registration No.: 317478
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully descri
bed in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FC
C is maintained in our files. Registration 317478, Renewal date Jul. 18, 2014, valid time is until Jul. 18, 2017.

IC-Registration No.: 5377A&5377B
The 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377A on Dec. 31, 2013, valid time is until Dec. 31, 2016.
Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
 Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B on Dec.03, 2014, valid time is until Dec.03, 2017.

ACA
Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the Aust
ralian C-Tick mark as a result of our A2LA accreditation.

VCCI
The 3m Semi-
anechoic chamber (12.2m×7.95m×6.7m) of Shenzhen Huatongwei International Inspection Co., Ltd.
has been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.:
R-2484. Date of Registration: Dec. 20, 2012. Valid time is until Dec. 29, 2015.
Radiated disturbance above 1GHz measurement of Shenzhen Huatongwei International Inspection Co., Ltd. h
as been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.:
G-292. Date of Registration: Dec. 24, 2013. Valid time is until Dec. 23, 2016.
Main Ports Conducted Interference Measurement of Shenzhen Huatongwei International Inspection Co., Ltd.
has been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.:
 C-2726. Date of Registration: Dec. 20, 2012. Valid time is until Dec. 19, 2015.
Telecommunication Ports Conducted Interference Measurement of Shenzhen Huatongwei International Inspe
ction Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control Measures with R
egistration No.: T-1837. Date of Registration: May 07, 2013. Valid time is until May 06, 2016.

DNV
Shenzhen Huatongwei International Inspection Co., Ltd. has been found to comply with the requirements of D
NV towards subcontractor of EMC and safety testing services in conjunction with the EMC and Low voltage Di
rectives and in the voluntary field. The acceptance is based on a formal quality Audit and follow-
ups according to relevant parts of ISO/IEC Guide 17025 (2005), in accordance with the requirements of the D
NV Laboratory Quality Manual towards subcontractors. Valid time is until Aug. 24, 2016.


 Report No:       TRE1606013303               Page:    8 of 18               Issued:       2016-07-06

3.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:

  Temperature:                                15-35 ° C

  Humidity:                                    30-60 %

  Atmospheric pressure:                     950-1050mbar


3.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                         Measurement
                        Test                        Range                                   Notes
                                                                          Uncertainty
              Radiated Emission                   30~1000MHz                4.24 dB          (1)
              Radiated Emission                     1~18GHz                5.16 dB           (1)
              Radiated Emission                    18-40GHz                 5.54 dB          (1)
              Conducted Disturbance               0.15~30MHz                3.39 dB          (1)

          (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
               confidence level using a coverage factor of k=2.


3.5. Equipments Used during the Test
 Conducted Emission
 Item Test Equipment                  Manufacturer           Model No.        Serial No.       Last Cal.
   1  EMI TEST RECEIVER               Rohde & Schwarz        ESCI             100106           2015/11/2
   2  ARTIFICIAL MAINS                Rohde & Schwarz        ESH2-Z5          100028           2015/11/2
   3  PULSE LIMITER                   Rohde & Schwarz        ESHSZ2           100044           2015/11/2
   4  EMI TEST SOFTWARE               Rohde & Schwarz        ES-K1            N/A              N/A

  Radiated Emission
  Item Test Equipment              Manufacturer              Model No.        Serial No.           Last Cal.
        ULTRA-BROADBAND
    1                              ShwarzBeck                VULB9163          538                 2015/11/2
        ANTENNA
    2   EMI TEST RECEIVER          Rohde & Schwarz           ESI 26           100009               2015/11/2
    3   EMI TEST Software          Audix                     E3               N/A                  N/A
    4   TURNTABLE                  MATURO                    TT2.0            ----                 N/A
    5   ANTENNA MAST               MATURO                    TAM-4.0-P        ----                 N/A
    6   EMI TEST Software          Rohde & Schwarz           ESK1             N/A                  N/A
        ULTRA-BROADBAND
    7                              Rohde&Schwarz             HL562             100015              2015/11/2
        ANTENNA
    8   Amplifer                   Sonoma                    310N              E009-13             2015/11/2
                                                             JS4-00101800-
   9     JS amplifer               Rohde & Schwarz                             F201504             2015/11/2
                                                             28-5A
   11    TURNTABLE                 ETS                       2088              2149                N/A
   12    ANTENNA MAST              ETS                       2075              2346                N/A
   13    HORN ANTENNA              Rohde&Schwarz             HF906             100039              2015/11/2

The calibration interval was one year.


 Report No:       TRE1606013303                  Page:             9 of 18                           Issued:         2016-07-06

4. TEST CONDITIONS AND RESULTS
4.1. Conducted Emissions Test

TEST CONFIGURATION

                                       V e r t. r e fe r e n c e
                                             p la n e
                                                                                                      E M I r e c e iv e r




                            EUT




     L IS N                                                  R e fe r e n c e g r o u n d p la n e



TEST PROCEDURE

1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
    manual. The EUT is a tabletop system; a wooden table with a height of 0.8 meters is used and is placed
    on the ground plane as per ANSI C63.4-2014.
2. Support equipment, if needed, was placed as per ANSI C63.4-2014
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4-2014.
4. The EUT received DC 5.0 from USB powered from AC120V/60Hz power through a Line Impedance
    Stabilization Network (LISN) which supplied power source and was grounded to the ground plane.
5. All support equipments received AC power from a second LISN, if any.
6. The EUT test program was started. Emissions were measured on each current carrying line of the EUT
    using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
    monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
    connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
    connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
7. Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.

CONDUCTED POWER LINE EMISSION LIMIT

For unintentional device, according to § 15.107(a) Line Conducted Emission Limits is as following:

                                              Maximum RF Line Voltage (dBμV)
    Frequency
                                       CLASS A                             CLASS B
      (MHz)
                              Q.P.               Ave.               Q.P.                                                      Ave.
    0.15 - 0.50                79                 66               66-56*                                                    56-46*
    0.50 - 5.00                73                 60                 56                                                        46
    5.00 - 30.0                73                 60                 60                                                        50

              * Decreasing linearly with the logarithm of the frequency

TEST RESULTS


Report No:   TRE1606013303   Page:   10 of 18   Issued:   2016-07-06


 Report No:    TRE1606013303             Page:   11 of 18             Issued:   2016-07-06




Remark:Transd=Cable lose+ PULSE LIMITER factor+ ARTIFICIAL MAINS factor; Margin= Limit -Level


 Report No:          TRE1606013303             Page:    12 of 18             Issued:    2016-07-06



4.2. Radiated Emission Test

TEST CONFIGURATION

     a)    Radiated Emission Test Set-Up, Frequency below 1000MHz




                                          3m

                Turntable
                                                                                       1m to 4m
                               EUT
            Test
          Receiver                               0.8m


              Ground Plane                                            Coaxial Cable



     b)    Radiated Emission Test Set-Up, Frequency above 1000MHz




TEST PROCEDURE

1.   The EUT is placed on a turntable, which is 0.8m above ground plane.
2.   The turntable shall be rotated for 360 degrees to determine the position of maximum emission level.
3.   EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the highest
     emissions.
4.   Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
5.   And also, each emission was to be maximized by changing the polarization of receiving antenna both
     horizontal and vertical.
6.   Repeat above procedures until the measurements for all frequencies are complete.


 Report No:       TRE1606013303                  Page:    13 of 18                  Issued:     2016-07-06

FIELD STRENGTH CALCULATION

  The field strength is calculated by adding the Antenna Factor and Cable Factor and subtracting the
  Amplifier Gain and Duty Cycle Correction Factor (if any) from the measured reading. The basic equation with a
  sample calculation is as follows:

    FS = RA + AF + CL - AG

  Where FS = Field Strength                                  CL = Cable Attenuation Factor (Cable Loss)
     RA = Reading Amplitude                                  AG = Amplifier Gain
     AF = Antenna Factor

   For example

         Frequency          FS             RA              AF            CL            AG           Transd
           (MHz)         (dBμV/m)       (dBμV/m)          (dB)          (dB)          (dB)           (dB)
           300.00           40            58.1            12.2           1.6          31.90          -18.1

   Transd=AF +CL-AG

RADIATION LIMIT

For unintentional device, according to § 15.109(a), except for Class A digital devices, the field strength of
radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following
values:

   Frequency (MHz)               Distance (Meters)               Radiated (dBμV/m)              Radiated (μV/m)
        30-88                           3                               40.0                          100
       88-216                           3                               43.5                          150
       216-960                          3                               46.0                          200
      Above 960                         3                               54.0                          500


 Report No:     TRE1606013303              Page:   14 of 18               Issued:   2016-07-06

TEST RESULTS
Below1GHz
HORIZONTAL




VERTICAL




Remark:Transd=Cable lose+ Antenna factor- Pre-amplifier;Margin=Limit -Level


 Report No:     TRE1606013303              Page:   15 of 18               Issued:      2016-07-06


Above 1GHz
HORIZONTAL




VERTICAL




Remark:Level=Reading+ Antenna factor+cable lose- Pre-amplifier; Margin= Level- Limit


Report No:   TRE1606013303            Page:   16 of 18             Issued:   2016-07-06



5. Test Setup Photos of the EUT
                             Conducted Emission PC Data Transfer




                     Radiated Emission (30MHz-1GHz) PC Data Transfer




                      Radiated Emission (above 1GHz) PC Data Transfer


Report No:   TRE1606013303   Page:   17 of 18   Issued:   2016-07-06


Report No:   TRE1606013303                 Page:      18 of 18                         Issued:   2016-07-06



6. External and Internal Photos of the EUT
  Reference to the test report No. TRE1606013301


                             .......................End of Report.........................



Document Created: 2016-07-07 09:25:04