MPE Report

FCC ID: 2AA7Y-MOSHIQI004

RF Exposure Info

Download: PDF
FCCID_4210315

                Maximum Permissible Exposure                                                 Report No. : FA920112




         Maximum Permissible Exposure
               FCC ID                 : 2AA7Y-MOSHIQI004
               Equipment              : SnapTo Car Mount with Wireless Charging
               Brand Name             : Moshi
               Model Name             : 99MO122002
               Applicant              : Aevoe Inc.
                                        27F., NO.68, Sec. 5, Zhongxiao E. Rd., Taipei City
                                        11065, Taiwan
               Manufacturer           : Powergene Technology Co., Ltd. Taiwan Branch
                                        1F-5, No.1, Wuquan 1st Rd., Xinzhuang Dist.,
                                        New Taipei City, Taiwan
               Standard               : 47 CFR Part 2.1091


 The product was received on Feb. 01, 2019, and testing was started from Feb. 21, 2019 and
 completed on Feb. 21, 2019. We, SPORTON INTERNATIONAL INC. EMC & Wireless Communications
 Laboratory, would like to declare that the tested sample has been evaluated in accordance with the
 procedures given in KDB680106 D01 RF Exposure Wireless Charging Apps v03 and shown
 compliance with the applicable technical standards.

 The report must not be used by the client to claim product certification, approval, or endorsement by
 TAF or any agency of United States government.

 The test results in this report apply exclusively to the tested model / sample. Without written
 approval of SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, the test
 report shall not be reproduced except in full.




   ___________________________________________                 __________________________________________
                       Approved by: Allen Lin                                   SDoC by: XXXXX


        SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory
                            No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.)


TEL : 886-3-327-3456                                                                  Page Number      : 1 of 10
FAX : 886-3-327-0973                                                                  Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                    Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                    Maximum Permissible Exposure                                                                                       Report No. : FA920112




                                                             Table of Contents
HISTORY OF THIS TEST REPORT .................................................................................................................. 3
1         HUMAN EXPOSURE ASSESSMENT ................................................................................................... 5
1.1       Maximum Permissible Exposure ............................................................................................................ 5
1.2       Testing Applied Standards ..................................................................................................................... 5
1.3       Testing Location Information .................................................................................................................. 6
1.4       Accessories ............................................................................................................................................ 6
1.5       Support Equipment ................................................................................................................................. 6
1.6       The Worst Condition ............................................................................................................................... 7
2         TEST EQUIPMENT AND CALIBRATION DATA ................................................................................10
 Photographs of EUT V01




TEL : 886-3-327-3456                                                                                                         Page Number           : 2 of 10
FAX : 886-3-327-0973                                                                                                         Issued Date           : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                                                           Report Version        : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                          Report No. : FA920112




                                           History of this test report

       Report No.                Version                 Description                    Issued Date

        FA920112                     01              Initial issue of report            Mar. 21, 2019




TEL : 886-3-327-3456                                                           Page Number      : 3 of 10
FAX : 886-3-327-0973                                                           Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                             Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                              Report No. : FA920112




                                     Summary of Test Result
 Report        Ref Std.                                                      Result
                                           Test Items                                               Remark
 Clause        Clause                                                     (PASS/FAIL)
    1.6            -        Maximum Permissible Exposure                      PASS                       -


Declaration of Conformity:
The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits
or requirements declared by manufacturers.
Comments and Explanations:
None.

Reviewed by: Sam Tsai

Report Producer: Debby Hung




TEL : 886-3-327-3456                                                               Page Number      : 4 of 10
FAX : 886-3-327-0973                                                               Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                 Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                                    Report No. : FA920112




1         Human Exposure Assessment
1.1       Maximum Permissible Exposure
1.1.1     Limit of Maximum Permissible Exposure
                                     Limits for Occupational / Controlled Exposure
                                                                                                   Averaging Time
    Frequency Range            Electric Field        Magnetic Field     Power Density (S)
                                                                                                    |E|²,|H|² or S
         (MHz)               Strength (E) (V/m)    Strength (H) (A/m)      (mW/ cm²)
                                                                                                     (minutes)
           0.3-3.0                    614                 1.63                (100)*                         6
                                                                                     2
           3.0-30                    1842 / f            4.89 / f           (900 / f )*                      6
           30-300                     61.4               0.163                 1.0                           6
         300-1500                       -                   -                 F/300                          6
        1500-100,000                    -                   -                   5                            6
                               Limits for General Population / Uncontrolled Exposure
                                                                                                   Averaging Time
    Frequency Range            Electric Field        Magnetic Field     Power Density (S)
                                                                                                    |E|²,|H|² or S
         (MHz)               Strength (E) (V/m)    Strength (H) (A/m)      (mW/ cm²)
                                                                                                     (minutes)
          0.3-1.34                    614                 1.63                (100)*                        30
                                                                                     2
          1.34-30                     824/f              2.19/f              (180/f )*                      30
           30-300                     27.5               0.073                 0.2                          30
         300-1500                       -                   -                F/1500                         30
        1500-100,000                    -                   -                  1.0                          30
    Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
    Note 2: For the applicable limit, see FCC 1.1310

1.2       Testing Applied Standards
 According to the specifications of the manufacturer, the EUT must comply with the requirements of the
 following standards:
  47 CFR Part 2.1091
  KDB680106 D01 RF Exposure Wireless Charging Apps v03




TEL : 886-3-327-3456                                                                     Page Number      : 5 of 10
FAX : 886-3-327-0973                                                                     Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                       Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                                       Report No. : FA920112



1.3       Testing Location Information
                                                     Testing Location
        HWA YA         ADD     : No. 52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District,
                                 Tao Yuan City, Taiwan, R.O.C.
                       TEL     : 886-3-327-3456             FAX    :   886-3-327-0973
                                        Test site Designation No. TW1190 with FCC.
    Test Condition           Test Site No.      Test Engineer             Test Environment                   Test Date
     RF Conducted              TH01-HY               Barry              23.8~24.7°C / 55~61%              21/Feb/2019

1.4       Accessories
                                                     Accessories
                                     Brand Name           moshi                  Model Name        1700000237
           USB Cable
                                     Power Rating         1 meter, Shielded cable, without ferrite core
Note: Regarding to more detail and other information, please refer to user manual.

1.5       Support Equipment
                                                    Support Equipment
  No.           Equipment                    Brand Name                    Model Name                        FCC ID
   1           Mobile phone                       Apple                      IPhone 8                          -
   2         DC Power Supply                      GW                       GPS-3030DD                          -




TEL : 886-3-327-3456                                                                        Page Number       : 6 of 10
FAX : 886-3-327-0973                                                                        Issued Date       : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                          Report Version    : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                              Report No. : FA920112




1.6       The Worst Condition
          Ancillary Equipment                 Charging Condition                Worst Charging Condition
              Mobile phone                       Charging Mode                        Charging Mode


1.6.1     Test Method
                                                  Test Method
      Performed aggregate both leakage E-field and H-field at surrounding the device from all simultaneous
      transmitting coils.
      During testing, the EUT was placed on a non-conductive table top and the ancillary equipment (e.g., mobile
      phone) was placed on the EUT for charging. Maximum E-field and H-field measurements were tested 10cm
      from each side of the EUT. Along the side of the EUT to center of E-field probe and H-field probe were
      positioned at the location to search maximum field strength.
      E-field transfer to H-field
      -   E-field = Z0 × H-field
          H-field = E-field ÷ Z0
          Where Z0 = Free Space Impedance = 377Ω




TEL : 886-3-327-3456                                                               Page Number      : 7 of 10
FAX : 886-3-327-0973                                                               Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                 Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                         Report No. : FA920112




1.6.2     Test Setup




Note1 : find worst position for each axis.
Note2 : This shall be measured as the distance from the edge of the device to the center of the measurement
probe.




TEL : 886-3-327-3456                                                          Page Number      : 8 of 10
FAX : 886-3-327-0973                                                          Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                            Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                Maximum Permissible Exposure                                               Report No. : FA920112




1.6.3     Result of Maximum Permissible Exposure
                                             Maximum Permissible Exposure
    Charging Condition           Separation     Probe from EUT Side     E-field (V/m)           H-field (A/m)
          Operating                  15cm               Left                0.58                     0.002
          Operating                  15cm              Right                0.66                     0.002
          Operating                  15cm               Top                 0.92                     0.002
          Operating                  15cm             Bottom                0.36                     0.001
          Operating                  20cm         Y-axis above EUT          0.61                     0.002
                                     Limit                                   614                      1.63
                             Margin Limit (%)                               0.15%                    0.15%




TEL : 886-3-327-3456                                                                Page Number      : 9 of 10
FAX : 886-3-327-0973                                                                Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                  Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004


                    Maximum Permissible Exposure                                                 Report No. : FA920112




2          Test Equipment and Calibration Data
 Instrument for Conducted Test
                                                                                                           Calibration Due
     Instrument        Manufacturer       Model No.        Serial No.       Spec.       Calibration Date
                                                                                                                Date

                     Narda Safety Test B-Field Probe 100
    B-Field Probe                                           M-0652      50Hz~400kHz       20/Jul/2018        19/Jul/2020
                     Solutions GmbH           cm2

    Exposure Level   Narda Safety Test
                                           ELT-400          N-0210      100kHz~3MHz       20/Jul/2018        19/Jul/2020
        Tester       Solutions GmbH

                     Narda Safety Test
      Probe EF                            0391 E-Field      D-0667      0.1MHz ~ 3GHz     20/Jul/2018        19/Jul/2020
                     Solutions GmbH

  Broadband Field Narda Safety Test
                                           NBM-550          E-0847      0.1MHz ~ 3GHz     20/Jul/2018        19/Jul/2020
       Meter      Solutions GmbH




TEL : 886-3-327-3456                                                                      Page Number      : 10 of 10
FAX : 886-3-327-0973                                                                      Issued Date      : Mar. 21, 2019
Report Template No.: HE1-A2 Ver2.2                                                        Report Version   : 01
FCC ID: 2AA7Y-MOSHIQI004



Document Created: 2019-03-24 19:17:39
Document Modified: 2019-03-24 19:17:39

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC