RF Exporure-Wireless Charging

FCC ID: 2AA7Y-MOSHIQI002

RF Exposure Info

Download: PDF
FCCID_4055598

                            FCC ID: 2AA7Y-MOSHIQI002

1.Measuring Standard
  FCC Part 1(1.1310) and Part 2(2.1091), KDB 680106 D01 RF Exposure Wireless Charging
App v03
1.2. Requiments
    Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These
categories are fixed installation, mobile, and portable and are defined as follows: o Fixed
Installations: fixed location means that the device, including its antenna, is physically secured at a
permanent location and is not able to be easily moved to another location. Additionally, distance
to humans from the antenna is maintained to at least 2 meters. o Mobile Devices: a mobile device
is defined as a transmitting device designed to be used in other than fixed locations and to be
generally used in such a way that a separation distance of at least 20 centimeters is normally
maintained between the transmitter's radiating structures and the body of the user or nearby
persons. Transmitters designed to be used by consumers or workers that can be easily re-located,
such as a wireless modem operating in a laptop computer, are
considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules
for evaluating mobile devices for RF compliance are found in 47 CFR §2.1091. o Portable
Devices: a portable device is defined as a transmitting device designed to be used so that the
radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable
device requirements are found in Section 2.1093 of the FCC's Rules (47 CFR§2.1093). The FCC
also categorizes the use of the device as based upon the user’s awareness and ability to exercise
control over his or her exposure.
The two categories defined are Occupational/ Controlled Exposure and General
Population/Uncontrolled Exposure. These two categories are defined as follows:
Occupational/Controlled Exposure: In general, occupational/controlled exposure limits are
applicable to situations in which persons are exposed as a consequence of their employment,
who have been made fully aware of the potential for exposure and can exercise control over their
exposure. This exposure category is also applicable when the exposure is of a transient nature
due to incidental passage through a location where the exposure levels may be higher than the
general population/uncontrolled limits, but the exposed person is fully aware of the potential for
exposure and can exercise control over his or her exposure by leaving the area or by some other
appropriate means. Awareness of the potential for RF exposure in a workplace or similar
environment can be provided through specific training as part of a RF safety program. If
appropriate, warning signs and labels can also be used to establish such awareness
by providing prominent information on the risk of potential exposure and instructions on methods
to minimize such exposure risks. General Population/Uncontrolled Exposure: The general
population / uncontrolled exposure limits are applicable to situations in which the general public
may be exposed or in which persons who are exposed as a consequence of their employment
may not be made fully aware of the potential for exposure or cannot exercise control over their
exposure. Members of the general public would come under this category when exposure is not
employment-related; for example, in the case of a wireless transmitter that exposes persons in its
vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are
not considered sufficient to allow the device to be considered under the occupational/controlled
category, and the general population/uncontrolled exposure limits apply to these devices.

1.3 Test configuration
  1, The field strength of both E-field and H-field was measured at 15cm using the equipment list
     above for determining compliance with the MPE requirements of FCC Part 1.1310.
  2, The RF power density was measured at Under maximum load test
  3, Maximum E-field and H-field measurements were made 15cm from each side of the EUT.
     Along the side of the EUT and still 15cm away from the edge of the EUT, the field probes
     were positioned at the location where there is maximum field strength. The maximum E-field
     and H-field is reported below.
  4, This device uses a wireless charging circuit for power transfer operating at the frequency of
   100 –205kHz. Thus, the 300kHz limits were used: E-field Limit = 614 (V/m); H-field limit = 1.63
   (A/m).


1.4 Test Setup




2. Limits




3. MEASURING DEVICE AND TEST EQUIPMENT
  2.1For MPE Measurement
                        Manuf                                  Last
      Equipment                   Model No.   Serial No.                  Calibrated until    Cal. Interval
                        acturer                             calibration
E-Field                 Narda     EF0391      Q15221       May 17, 2018   May 16, 2019       1 Year
Probe(100kHz-3GHz)
H-Field                 Narda     HF3061      Q15835       May 17, 2018   May 16, 2019       1 Year
Probe(300KHz-30MHz)
Broadband Field Meter   Narda     NBM-550     Q201455      May 17, 2018   May 16, 2019       1 Year
Load                    N/A       N/A         N/A          N/A            N/A                N/A


   4. Measuring Results
EUT:              Symbus Q                 Model Name. :                       99MO084218
                                           Relative
Temperature:      26 ℃                                                         54%
                                           Humidity:
Pressure:         1010hPa                  Test Date:                          2018-09-20
Test Voltage:     DC 19V from adapter AC 120V/60Hz
Test Mode :       Max Load

   Low frequency:
                                  Table 1. H-Field MPE Data-Top
                                  EUT                  Limits
                                         Top(V/m)
                                  Side                 (V/m)
                                  Max
                                           0.026        1.63
                                  load


   Table 2. H-Field MPE Data- Surrounding
                                                                     Z-              Limits
           EUT                                    Bottom
                   Left(A/m) Right(A/m)                         Axis(above)          (A/m)
           Side                                    (A/m)
                                                                   (A/m)
           Max
                       0.008           0.033          0.042          0.059           1.63
           load

                                      Table 3. E-Field MPE
                                   E-Field Measurement (15cm)
                                                                            Z-              Limits
    EUT                                                   Bottom
            Left(V/m) Right(V/m) Top(V/m)                              Axis(above)          (V/m)
    Side                                                   (V/m)
                                                                          (V/m)
    Max
                2.11            1.98           1.77           1.28           1.23             614
    load


   Middle frequency:
                                  Table 1. H-Field MPE Data-Top
                                  EUT                  Limits
                                         Top(V/m)
                                  Side                 (V/m)
                                  Max
                                           0.028        1.63
                                  load


   Table 2. H-Field MPE Data- Surrounding
                                                                     Z-              Limits
           EUT                                    Bottom
                   Left(A/m) Right(A/m)                         Axis(above)          (A/m)
           Side                                    (A/m)
                                                                   (A/m)
           Max
                       0.0012          0.044          0.037          0.061           1.63
           load


                                 Table 3. E-Field MPE
                              E-Field Measurement (15cm)
                                                                       Z-              Limits
EUT                                                  Bottom
        Left(V/m) Right(V/m) Top(V/m)                             Axis(above)          (V/m)
Side                                                  (V/m)
                                                                     (V/m)
Max
          2.17             2.00           1.82           1.36           1.17             614
load


High frequency:
                             Table 1. H-Field MPE Data-Top
                             EUT                  Limits
                                    Top(V/m)
                             Side                 (V/m)
                             Max
                                      0.028        1.63
                             load

Table 2. H-Field MPE Data- Surrounding
                                                                Z-              Limits
       EUT                                   Bottom
              Left(A/m) Right(A/m)                         Axis(above)          (A/m)
       Side                                   (A/m)
                                                              (A/m)
       Max
                  0.0009          0.039          0.041          0.058           1.63
       load

                                 Table 3. E-Field MPE
                              E-Field Measurement (15cm)
                                                                       Z-              Limits
EUT                                                  Bottom
        Left(V/m) Right(V/m) Top(V/m)                             Axis(above)          (V/m)
Side                                                  (V/m)
                                                                     (V/m)
Max
          2.23             1.94           1.81           1.56           1.25             614
load

Remark: According KDB 680106 D01 RF Exposure Wireless Charging App v03,
section 5, b). The aggregate H-field strengths at 15 cm surrounding the device
and 20 cm above the top surface from all simultaneous transmitting coils are
demonstrated to be less than 50% of the MPE limit. The E- field evaluation
conducted assuming a user separation distance of 15 cm according to the KDB
680106 D01 RF Exposure Wireless Charging App v03 section 3, c).

Note: The EUT supports one voltage input and output. The EUT performs one
voltage mode pretests.

Result: The device comply with the RF exposure requirement according to
680106 D01 v03, section 5, b).


5. PHOTOGRAPHS OF TEST SETUP
15 cm surrounding




20 cm above the top


Signature:                                                      Date: 2018-09-27


NAME AND TITLE (Please print or type): Jason Chen /Manager
COMPANY (Please print or type): Shenzhen NTEK Testing Technology Co., Ltd./ 1/F, Building E,
Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen P.R. China.



Document Created: 2018-11-01 02:51:58
Document Modified: 2018-11-01 02:51:58

© 2024 FCC.report