Contents
User Guide ................................................................................................................................. 2
1.      Introduction ........................................................................................................................ 4
     1.1        Intro........................................................................................................................................................... 4
     1.2        CAUTION READ THIS BEFORE USING BATTERY ........................................................................................... 5
     1.3        Charger ...................................................................................................................................................... 5
     1.4        Notes ......................................................................................................................................................... 6

2.      Components and Features ................................................................................................... 7
     2.1        Components and Buttons .......................................................................................................................... 7
     2.2        Device Specifications ................................................................................................................................. 8
     2.3        Micro SD, SIM card....................................................................................................................................10
     2.4        Battery Charging .......................................................................................................................................10

3.      UHF RFID........................................................................................................................... 11
4.      Other Features .................................................................................................................. 12
     4.1        PING tool ..................................................................................................................................................12
     4.2        Bluetooth ..................................................................................................................................................13
     4.3        GPS ...........................................................................................................................................................14
     4.4        Volume setup............................................................................................................................................15
     4.5        Sensor .......................................................................................................................................................16
     4.6        Keyboard ..................................................................................................................................................17
     4.7        Network....................................................................................................................................................18
     4.8        Keyboard emulator (optional)...................................................................................................................19
     4.9        Call function ..............................................................................................................................................20
        Calling numbers ....................................................................................................................................................... 20
        Contacts ................................................................................................................................................................... 20
        SMS and MMS.......................................................................................................................................................... 20

5.      Optional Features ............................................................................................................. 21
     5.1        Barcode Scanner (Optional) ......................................................................................................................21

Restrictions: ............................................................................................................................. 23
SAR Information ....................................................................................................................... 24
Simplified EU declaration of conformity ................................................................................... 24
Warranty ................................................................................................................................. 25
     WARRANTY ..........................................................................................................................................................25
     EXCLUSIONS .........................................................................................................................................................25
     RMA PROCEDURE .................................................................................................................................................25
     DISCLAIMER OF WARRANTIES ..............................................................................................................................25
     LIMITATION OF LIABILITY .....................................................................................................................................25


Pyxis User Guide - Version 0.3.3                                                                                                                                                     1


User Guide

Version 0.3.3

07th August 2019



Star Systems International and the Star Systems International logo are trademarks of Star Systems
International Ltd. in Hong Kong and other countries.

Specifications are subjected to changes without prior notice.

Disclaimer and limitation of liability
Star Systems International Ltd. shall not be liable for technical or editorial errors or omissions contained
herein or for incidental or consequential damages about the furnishing, performance, or use of this
material. The information in this document is provided “as is” without warranty of any kind - including but
not limited to, the implied warranties of merchantability and fitness for a purpose and is subjected to
change without notice. The warranties for Star Systems International products are set forth in the express
limited warranty statements accompanying such products. Nothing herein should be construed as
constituting an additional warranty.

This document contains proprietary information that is protected by copyright. No part of this document
may be photocopied, reproduced, or translated to another language without the prior written consent of
Star Systems International Ltd.

This product is not designed, intended, authorized or warranted to be suitable for life support applications
or any other life critical applications which could involve potential risk of death, personal injury, property
damage, or environmental damage.

Your safety is extremely important. Read and follow all warnings and cautions in this document before
handling and operating RFID equipment. You can be seriously injured, and equipment and data can be
damaged if you do not follow the safety warnings and cautions.
A caution alerts you to an operating procedure, practice, condition, or statement that must be strictly
observed to prevent equipment damage or destruction, or corruption or loss of data.
Note: Notes either provide extra information about a topic or contain special instructions for handling a
condition or set of circumstances.




Pyxis User Guide - Version 0.3.3                                                                                 2


FCC Compliance
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
 (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications
 or changes to this equipment. Such modifications or changes could void the user’s authority to operate the
equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
 interference in a residential installation. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
 .Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
.Consult the dealer or an experienced radio/TV technician for help. During SAR testing, this device is set to transmit
at its highest certified power level in all tested frequency bands, and placed in positions that simulate RF exposure
in usage near the body with the separation of 10 mm. Although the SAR is determined at the highest certified power
level, the actual SAR level of the while operating can be well below the maximum value. This is because the device
is designed to operate at multiple power levels so as to use only the power required to reach the network.
In general, the closer you are to a wireless base station antenna, the lower the power output.

FCC Radiation Exposure Statement .
This device was tested for typical body.worn operations with the back of the handset kept 10mm from the body.
 To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 10 mm separation
distance between the user's body and the back of the handset. The use of belt clips, holsters and similar accessories
should not contain metallic components in its assembly. The use of accessories that do not satisfy these
requirements may not comply with FCC RF exposure requirements, and should be avoided.

RF Exposure Information(SAR)
The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue.
Device Types HRD23001F (FCC ID: 2AA7KPYXIS-HRD23000) has also been tested against this SAR limit.
The highest SAR value reported under this standard during product certification for use when properly worn on
the body is1.168 W/kg and for head is 0.24 W/kg




Pyxis User Guide - Version 0.3.3                                                                            3


1. Introduction

1.1 Intro

PYXIS device is a smart mobile PDA that integrated with various features such as wireless communication,
data acquisition, wireless transmission, data processing and UHF scanning etc. It is configured with Android
OS and it possesses high reliability and expansibility. With a set of advanced data acquisition options, PYXIS
can be operated in various industries to acquire precise and abundant datum automatically. Meanwhile,
the device can match the options with staffs accordingly. The corporation which deployed PYXIS will realize
the deployment work is simple and maintenance work will be remarkably decreased.
PYXIS is highly rugged, compact and durable. With IP65 water and dustproof capability, the device has met
IEC sealing standard. Therefore, it can be operated by staff such as Vehicle Administration, Inventory
Management, Asset Management, Fleet Management etc. Wherever your staff locations are, PYXIS can
remain its connectivity with the system to make sure business in high-effective operating.
PYXIS mobile data terminal adopted 4G LTE technology to realize multipath communication and calling
function for fieldwork, data exchange efficiency has been enhanced simultaneously (Optional). Therefore,
PYXIS will bring the largest investment return for enterprises.




Pyxis User Guide - Version 0.3.3                                                                             4


1.2 CAUTION READ THIS BEFORE USING BATTERY

   •   Do not leave the battery unused for an extended period of time, whether it is in the device or not.
       If the battery has been used for over 6 months, it should be checked to assure the charging
       function is working properly or it should be disposed of correctly.
   •   The lifespan of a Li-ion battery is around 2 to 3 years, it can be recharged for approximately 300 to
       500 times. (One full battery charge period means completely charged and completely discharged.)
   •   Even when a Li-ion battery is not in use, it will continue to discharge slowly. Therefore, the battery
       charging status should be checked frequently per recommended practices.
   •   Observe and record the information of any new unused and non-fully charged battery. Based on
       operating time of new battery and compare with a battery that has been used for long time.
       According to product configuration and application program, the operating time of battery would
       be different.
   •   Check battery charging status at regular intervals.
   •   When the battery capacity drops below about 80%, charging time may be increased.
   •   If a battery is stored or otherwise unused for an extended period, be sure to follow the storage
       instructions in this document. If you do not follow the instructions, and the battery has no charge
       remaining, consider it to be damaged. Do not attempt to recharge it or to use it. Replace it with a
       new battery.
   •   Store the battery at temperatures between 5 °C and 20 °C (41 °F and 68 °F).



1.3 Charger

The charger model is GME10D-050200FGu, output voltage/current is 5V DC/2A.




Pyxis User Guide - Version 0.3.3                                                                                5


1.4 Notes


1. Using the incorrect type battery is dangerous and may cause fire or an explosion.
Please dispose the used battery according to instructions.

2. The Reader Device and its battery should only be connected to a USB Interface, version 2.0 or higher.
Using other types of USB power is not recommended and will void your warranty.

3. The suitable temperature range for this product and accessories is 0-10°C to 50°C.

4. Caution risk of explosion if battery is replaced by an incorrect type. Dispose of any used batteries
according to the instructions.




Pyxis User Guide - Version 0.3.3                                                                           6


2. Components and Features

2.1 Components and Buttons

Pyxis has 4 side buttons, 4 main buttons and a trigger on handle, UHF scanning area,
2D scanning module (OPTIONAL), HD camera and flashlight locate on the top.

                                                                                       11

              9     10              2                                                  12
                                    3

                                                                                       13

                                                                                       14
                                    4
                                                                                       9



                                    6
                                    7
                                    8




                            Function                                Description
             1. RGB LED                               Monitor Display Device

             2. Light Sensor, Distance Sensor         Light and distance detection
             3. Front Camera                          Photos and Videos record

             4. UHF Scanning Module                   Scanning RFID Tags

             5. Menu                                  Display main menu
             6. Home                                  Back to main screen

             7. Back                                  Return to last step

             8. Trigger                               Start scanning or take photos
                                                      Two Scanning buttons located on each
             9. Scan button
                                                      side of the Pyxis
             10. SIM/SD Card Slot                     Install SIM card or SD card
             11. Barcode Scanner                      Scan 1D/2D barcode (OPTIONAL)

             12. Top Camera, Flashlight               Photos and Videos record

             13. Power button                         Press to turn on/off device
                                                      Custom function which can be defined
             14. Setup button
                                                      by software



Pyxis User Guide - Version 0.3.3                                                             7


2.2 Device Specifications

                         Physical characteristics
                Size         164.2mm*78.8mm*17mm
               Weight        <654g (battery included)
               Display       5.2 inch, IPS FHD 1920*1080P
                             4 main keyboards, 1 power button, 2 scan
             Touch panel
                             buttons, 1 multi-function button
               Battery       Li-ion, rechargeable, 8000mAh
              Expansion      Micro SD card, up to 32 GB
            Expansion Slot   1 SIM, 1 SIM/Micro SD
                Audio        speaker, 2 microphones, voice call
               Camera        13MP autofocus camera with flashlight



                               Performance
                CPU          Cortex-A53 1.45GHz Quadcore
                 OS          Android
                RAM          2GB RAM
           Communication
                             USB2.0, Type-C, OTG
             Interface
                ROM          16GB
           Max. expansion    Supports up to 32 GB Micro SD card



                             User environment
           Operating temp.   -10℃ to 50℃
            Storage Temp.    -40℃ to 70℃
               Humidity      5%RH – 95%RH non-condensing
                Sealing      IP65, IEC sealing standard
                 Drop
                             Multiple 1.8m/4.0ft drops to the concrete
             specification




Pyxis User Guide - Version 0.3.3                                         8


                               Communication
                WAN           EU(Option):
                              2G: 850/900/1800/1900MHz
                              3G: 850/900/1900/2100MHz
                              4G: B1, B3, B5, B7, B8, B20, B40

                              US(Option):
                              2G: 850/900/1800/1900MHz
                              3G: 850/900/1700/1900MHz
                              4G: B2, B4, B7, B12, B17

                              CN(Option):
                              2G: 900/1800MHz
                              3G: 900/1900/2000/2100MHz
                              4G: B1, B3, B5, B38, B39, B40, B41

                WLAN          IEEE802.11a/b/g/n, embedded antenna,
                              5 Gigabit WiFi (5G wifi isn’t support hotspot)
                              WiFi 2.4G; max. power 14.69 dBm
                              WiFi 5G - Band1: max. power 14.69 dBm
                              WiFi 5G - Band2: max. power 12.82 dBm
                              WiFi 5G - Band3: max. power 13.08 dBm
                              SRD5.8G; max. power 12.29 dBm
               WPAN           Bluetooth 4.0; max. power 6.16 dBm



                               Data collection
               Barcode        2D CMOS scanning engine
               scanning       (Honeywell N6603/Zebra SE4710)
              (Optional)
                 RFID         NFC 13.56Mhz
                              62.57 dBμV/m (3m) -14.23dBμA/m (10m)



                           Developing Environment
                 SDK          STAR Systems software develop kit
              Language        Java
               Develop        Eclipse/Android Studio




Pyxis User Guide - Version 0.3.3                                               9


2.3 Micro SD, SIM card



   1. Take out the card slot using specified SIM card ejector.




   2. Install SIM card/Micro SD in correct direction.




2.4 Battery Charging

By using a USB Type-C connector. Please, it is recommended to only use the original adaptor for charging
the device.

Charging the battery with a power supply adapter not provided/approved by Star Systems may damage
your device and/or void your warranty.


Pyxis User Guide - Version 0.3.3                                                                           10


3. UHF RFID


Open App Center          in the Applications.



Open “UHF” to read and write, kill and lock a UHF transponder/tag.




Pyxis User Guide - Version 0.3.3                                     11


4. Other Features
4.1 PING tool

   1. Open “PING” in App Center.
   2. Setup PING parameters and select external/internal addresses.




Pyxis User Guide - Version 0.3.3                                      12


4.2 Bluetooth

   1. Open “BT Printer” in App Center.
   2. In the list of detected devices, click the device that you want to pair with.
   3. Select printer and click “Print” to start printing contents.




Pyxis User Guide - Version 0.3.3                                                      13


4.3 GPS

   1. Click “GPS” in App Center to open GPS test.
   2. Setup GPS parameters to access GPS information.




Pyxis User Guide - Version 0.3.3                        14


4.4 Volume setup

   1. Click “Volume” in App Center.
   2. Setup volume per user requirements.




Pyxis User Guide - Version 0.3.3            15


4.5 Sensor

   1. Click “Sensor” in App Center.
   2. Setup the sensor per user requirements.




Pyxis User Guide - Version 0.3.3                16


4.6 Keyboard

   1. Click “Keyboard” in App Center.
   2. Setup and test the main value of the device.




Pyxis User Guide - Version 0.3.3                     17


4.7 Network

   1. Click “Network” in App Center.
   2. Test WIFI/Mobile signal.




Pyxis User Guide - Version 0.3.3       18


4.8 Keyboard emulator (optional)

The keyboard emulator can be used in multiple operating background and output formats directly. And it
includes Prefix/Suffix/Enter/TAB.

Please check the Keyboard emulator manual for more details.




Pyxis User Guide - Version 0.3.3                                                                         19


4.9 Call function


Calling numbers


   1. Click icon       .
   2. Click desired number keys to input phone numbers.




   3. Click icon         to call.

   4. Click icon        to end the call.



Contacts

   1. Click icon        to open contacts list.


   2. Click icon          to add new contacts.



SMS and MMS

   1. Click         to open message window.
   2. Click        to input message recipient and contents.

   3. Click        to send out messages.

   4. Click        to add attachments, pictures or videos.



Pyxis User Guide - Version 0.3.3                              20


5. Optional Features


5.1 Barcode Scanner (Optional)

   1. In App Center, open 2D barcode scan test.
      (This function will show if your device has the appropriate Barcode Scan Engine.)

   2. Press the “SCAN” button or click the scan key to start scanning. “Auto interval” can be adjusted by
      the user as desired.




       Caution: Please scan codes in correct orientation otherwise the scanning may failed.


   1D barcode:




   2D code:




Pyxis User Guide - Version 0.3.3                                                                        21


Max. radiant power: 0.6mW

Wavelength: 655nM

IEC 60825-1 (Ed.2.0).

21CFR 1040.10 and 1040.11 standard.




Pyxis User Guide - Version 0.3.3      22


Restrictions:

 AT    BE    BG     HR    CY       CZ   DK
 EE    FI    FR     DE    GR       HU   IE
 IT    LV    LT     LU    MT       NL   PL
 PT    RO    SK     SI    ES       SE   UK


This device is restricted to indoor use where operated in the European Community using frequency in
5150MHz-5350MHz to reduce the potential for interference.




Pyxis User Guide - Version 0.3.3                                                                      23


SAR Information
The SAR limit of Europe is 2.0 W/kg. Device types Pyxis has also been tested against this SAR limit. The
highest SAR value reported under this standard during product certification for use at the ear is 0.219W/kg
and when properly worn on the body is 1.216 W/kg. This device was tested for typical body-worn
operations with the back of the handset kept 0.5cm from the body. To maintain compliance with RF
exposure requirements, use accessories that maintain a 0.5cm separation distance between the user's body
and the back of the handset. The use of belt clips, holsters and similar accessories should not contain
metallic components in its assembly. The use of accessories that do not satisfy these requirements may not
comply with RF exposure requirements and should be avoided.




Simplified EU declaration of conformity

Hereby, STAR Systems International Ltd. declares that the radio equipment type Pyxis is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet
address:www.star-int.net




Pyxis User Guide - Version 0.3.3                                                                            24


Warranty

WARRANTY
All Hardware Products sold by Star Systems International Limited (SSI) are warranted against defects in
material and workmanship under normal use and service for one (1) year from the original date of purchase
(the “Warranty”). Any Extended Warranties must be documented on the original invoice as a separate line
item. For defects covered by this Warranty, SSI will repair the defect or replace the product, at its sole option
and return the product to you.

EXCLUSIONS
If the defect was caused by any of the following, the Warranty shall not apply and an estimate for repair or
replacement will be submitted for your approval prior to work being performed: abuse, mishandling, natural
disaster, vandalism, accident, electrostatic discharge damage, failure to follow installation or operating
instructions, failure to provide a suitable environment, unauthorized modification of the product
modification of the printed circuit board by parties other than SSI, and damage that is caused during shipping
for warranty service and any product that is returned with the security seal broken.

RMA PROCEDURE
For Warranty service, the Customer must comply with Star Systems International Return Materials
Authorization (“RMA”) policy, which is published on the Star Systems International website at www.star-
int.net and may be updated from time to time. Prior to shipping a product to Star Systems International for
warranty inspection, replacement or repair, an RMA number must be obtained from Star Systems
International’s RMA department at +852 3691 9925 or by email at support@star-int.net. RMA forms can be
downloaded from the Star Systems International website or the Customer can receive the form by email by
contacting the RMA department. One RMA form must be used for each RMA submission and the product
should be shipped to the address below. For products covered by this Warranty, the Customers are
responsible for payment of shipping costs to the Star Systems International repair center and Star Systems
International will be responsible for the cost of returning the item. The standard return shipment is “Speed
Post”. Any other desired “expedited” or overnight shipping costs for warranty repairs will be the customer’s
responsibility.

DISCLAIMER OF WARRANTIES
Other than set forth above, SSI hereby disclaims all warranties, expressed or implied, including without
limitation, the warranties of equipment warranty (rev 2-2017) merchantability, fitness for a particular
purpose and noninfringement.

LIMITATION OF LIABILITY
In no event will SSI be liable for any consequential, indirect, exemplary, special, or punitive damages, whether
arising out of contract, tort, negligence, strict liability or otherwise. In no event will Star Systems
International’s total cumulative, aggregate liability, whether arising out of contract, tort, negligence, strict
liability, or otherwise, exceed the price actually paid by the customer for the product from which the claim
arises.


    This warranty gives the Customer specific legal rights, and the Customer may also have other rights that may vary from local
jurisdiction. If the Customer has questions concerning the product or warranty, contact the dealer from which it was purchased. The
           Customer may also contact Star Systems International at the following address and ask for warranty assistance.




Pyxis User Guide - Version 0.3.3                                                                                                25


About Us
STAR Systems International is a market leader providing solutions including RFID transponders, readers and
professional consulting services for Auto ID & Vehicle Identification Applications. STAR Systems leverages technical
implementation expertise, training and support to ensure customer success. “Your Success Is Our Vision”.

STAR Systems International’s focus is providing best-in-class technologies for Smart City Initiatives including;
Electronic Tolling (ETC), Electronic Vehicle Registration (EVR), Fleet Management, Parking and Secure Access Control
applications. STAR Systems International’s mission is to enable our partners and users to experience high-
performance and reliable integrated solutions which are key elements of any modern Smart City initiatives.

For more information on STAR Systems International, please visit our website www.star-int.net




Pyxis User Guide Version 0.3.3                                Copyright © 2019 SSI reserves the right to change specifications without prior notice



Document Created: 2019-10-12 09:34:01
Document Modified: 2019-10-12 09:34:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC