Test Report.pdf

FCC ID: 2AA3H-BT410

Test Report

Download: PDF
FCCID_2134769

                          Test Report No.: RF131014N062



                                                                 TEST REPORT
       Applicant                       Shenzhen 3nod Digital Technology Co., Ltd

                                       Building D Park 8# Road Tangxiayong Village, Industrial Zone Songgang Town,
       Address
                                       Baoan District, Shenzhen City, China.


       Manufacturer or
                                       LENOVO (BEIJING) LIMITED
       Supplier

                                       No.6 Chuang Ye Road Shangdi Information Industry Base, Haidian District, Beijing,
       Address
                                       China

       Product                         Speaker


       Brand Name


       Model                           BT410

       Additional Model &
                                       N/A
       Model Difference

       Date of tests                   Oct. 14, 2013 ~ Oct. 24, 2013

       The submitted sample of the above equipment has been tested according to the requirements of the
       following standards:

            FCC Part 15, Subpart C, Section 15.249(2012-10)

       CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Venless Long                                                             Approved by Glyn He
                   Project Engineer / EMC Department                                                     Supervisor / EMC Department




       This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
       permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
       forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
       identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
       information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
       negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
       within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
       report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
       non-compliance to the specification

                                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch                                          Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                              Page 1 of 33                                                               Report Version 1


                         Test Report No.: RF131014N062



                                                     TABLE OF CONTENTS

          RELEASE CONTROL RECORD ............................................................................................................ 4

          1      SUMMARY OF TEST RESULTS.................................................................................................... 5

          2      MEASUREMENT UNCERTAINTY................................................................................................. 5

          3      GENERAL INFORMATION ............................................................................................................ 6

              3.1   GENERAL DESCRIPTION OF EUT ........................................................................................... 6
              3.2   DESCRIPTION OF TEST MODES ............................................................................................. 7
              3.3   GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 8
              3.4   DESCRIPTION OF SUPPORT UNITS ....................................................................................... 8

          4      TEST TYPES AND RESULTS........................................................................................................ 9

              4.1   CONDUCTED EMISSION MEASUREMENT ............................................................................. 9
                4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ...................................................... 9
                4.1.2 TEST INSTRUMENTS ........................................................................................................... 9
                4.1.3 TEST PROCEDURES .......................................................................................................... 10
                4.1.4 DEVIATION FROM TEST STANDARD ................................................................................ 10
                4.1.5 TEST SETUP ........................................................................................................................11
                4.1.6 EUT OPERATING CONDITIONS..........................................................................................11
                4.1.7 TEST RESULTS ................................................................................................................... 12
              4.2   RADIATED EMISSION MEASUREMENT ................................................................................ 14
                4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT.......................................................... 14
                4.2.2 TEST INSTRUMENTS ......................................................................................................... 15
                4.2.3 TEST PROCEDURES .......................................................................................................... 16
                4.2.4 DEVIATION FROM TEST STANDARD ................................................................................ 17
                4.2.5 TEST SETUP ....................................................................................................................... 17
                4.2.6 EUT OPERATING CONDITIONS......................................................................................... 17
                4.2.7 TEST RESULTS ................................................................................................................... 18
              4.3   20dB BANDWIDTH MEASUREMENT...................................................................................... 26
                 4.3.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT.............................................................. 26
                 4.3.2 TEST INSTRUMENTS......................................................................................................... 26
                 4.3.3 TEST PROCEDURE............................................................................................................ 26
                 4.3.4 DEVIATION FROM TEST STANDARD ............................................................................... 26
                 4.3.5 TEST SETUP....................................................................................................................... 27
                 4.3.6 EUT OPERATING CONDITIONS ........................................................................................ 27
                                                      No. 34, Chenwulu Section, Guantai Rd., Houjie             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                                      Fax: +86 769 8593 1080
Dongguan Branch                                       Guangdong 523942, China                                   Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 2 of 33                                                             Report Version 1


                        Test Report No.: RF131014N062
                4.3.7 TEST RESULTS .................................................................................................................. 27

          5     PHOTOGRAPHS OF THE TEST CONFIGURATION .................................................................. 32


          6    APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE
               EUT BY THE LAB.......................................................................................................................... 33




                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                      Fax: +86 769 8593 1080
Dongguan Branch                                      Guangdong 523942, China                                   Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 3 of 33                                                             Report Version 1


                      Test Report No.: RF131014N062



                                    RELEASE CONTROL RECORD

           ISSUE NO.                REASON FOR CHANGE                                                     DATE ISSUED
           RF131014N062             Original release                                                       Oct. 24, 2013




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 4 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          1 SUMMARY OF TEST RESULTS
          The EUT has been tested according to the following specifications:
                          APPLIED STANDARD: FCC PART 15, SUBPART C (SECTION 15.249)
            STANDARD
                                    TEST TYPE AND LIMIT             RESULT                        REMARK
             SECTION
             §15.203            Antenna Requirement                  PASS          No antenna connector is used
                                Conducted Emission
           §15.207 (a)                                               PASS                        Compliant
                                     Measurement
             §15.205         Restricted Band of Operation            PASS                        Compliant
             §15.209
                                     Radiated Emission               PASS                        Compliant
            §15.249(a)
            §15.215(c)              20dB Bandwidth Test              PASS                        Compliant



          2 MEASUREMENT UNCERTAINTY
          Where relevant, the following measurement uncertainty levels have been estimated
          for tests performed on the EUT as specified in CISPR 16-4-2:
                 MEASUREMENT                             FREQUENCY                          UNCERTAINTY
                Conducted emissions                       9kHz~30MHz                                2.67dB
                                                         9KHz ~ 30MHz                               2.74dB
                                                         30MHz ~ 1GHz                               4.81dB
                 Radiated emissions
                                                         1GHz ~ 18GHz                                4.3dB
                                                        18GHz ~ 40GHz                               1.94dB

          This uncertainty represents an expanded uncertainty expressed at approximately
          the 95% confidence level using a coverage factor of k = 2.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 5 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          3 GENERAL INFORMATION
          3.1 GENERAL DESCRIPTION OF EUT

          PRODUCT                                Speaker
          TEST MODEL                             BT410
          FCC ID                                 2AA3H-BT410
          NOMINAL VOLTAGE                        DC 3.7V from Battery
          MODULATION TECHNOLOGY FHSS
          MODULATION TYPE                        GFSK, 8DPSK, π/4 DQPSK
          OPERATING FREQUENCY                    2402-2480MHz
          ANTENNA TYPE                           PCB antenna with 0.54dBi Gain
          I/O PORTS                              Refer to user’s manual
          CABLE SUPPLIED                         USB Cable: Unshielded, Detachable 0.5m
          NOTE:
            1. For a more detailed features description, please refer to the manufacturer’s specifications or
               the user's manual.

            2. For the test results, the EUT had been tested with all conditions. But only the worst case
               was shown in test report.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 6 of 33                                                       Report Version 1


                        Test Report No.: RF131014N062


          3.2 DESCRIPTION OF TEST MODES
          Pre-Scan has been conducted to determine the worst-case mode from all possible
          combinations between available modulations, data rates and packet type.
          The EUT was tested under the following modes, and the final worst is marked in
          boldface and recorded in the report.

            EUT CONFIGURE                 APPLICABLE TO
                                                                                              DESCRIPTION
                MODE      RE<1G             ≥1G
                                          RE≥        PLC       BW

                    A               -       -         -         √                  Powered by battery with Bluetooth link

                    B               √       √         √         -                  Powered by USB with Bluetooth link

                Where     RE<1G: Radiated Emission below 1GHz                  ≥1G: Radiated Emission above 1GHz
                                                                             RE≥
                          PLC: Power Line Conducted Emission                 BW: 20db bandwidth




           Following channel(s) was (were) selected for the test as listed below:

                 TESTED                 MODULATION            MODULATION                                                  PACKET
                                                                                            DATA RATE
                CHANNEL                 TECHNOLOGY               TYPE                                                      TYPE
            Low, Middle, High              FHSS                      GFSK                          1M                      DH1/3/5

            Low, Middle, High              FHSS                  π/4 DQPSK                         2M                      DH1/3/5

            Low, Middle, High              FHSS                      8DPSK                         3M                      DH1/3/5


                CHANNEL NUMBER                            TESTED CHANNEL                        TESTED FREQUENCY
                             0                                       Low                                  2402 MHz
                            39                                      Middle                                2441 MHz
                            78                                      High                                  2480 MHz


           After estimating all the combination of every test mode, the result shown as below
           is the worst case
                 TESTED                 MODULATION            MODULATION                                                  PACKET
                                                                                            DATA RATE
                CHANNEL                 TECHNOLOGY               TYPE                                                      TYPE
            Low, Middle, High              FHSS                      GFSK                          1M                         DH5
            Low, Middle, High              FHSS                      8DPSK                         3M                         DH5




                                                No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                                Page 7 of 33                                                        Report Version 1


                      Test Report No.: RF131014N062



          3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS


           The EUT is a RF Product. According to the specifications of the manufacturer, it
           must comply with the requirements of the following standards:

           FCC Part 15, Subpart C, Section 15.249(2012-10)
           ANSI C63.10-2009

           All test items have been performed and recorded as per the above standards.

           NOTE: It has been verified to comply with the requirements of FCC Part 15, Subpart B, Class B
                  (Doc). The test report has been issued separately.


          3.4 DESCRIPTION OF SUPPORT UNITS

          The EUT has been tested as an independent unit together with other necessary
          accessories or support units. The following support units or accessories were used
          to form a representative test configuration during the tests.

           NO.      PRODUCT            BRAND           MODEL NO.             SERIAL NO.                        FCC ID
            1        BT Tester      Rohde&Schwarz       CBT 32               1153.9000.32                       N/A
            2        Notebook           DELL               E6420                9H12FS1                           N/A

           NO.            SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
            1 AC Line: Unshielded, Detachable, 1.5m
            2 AC Line: Unshielded, Detachable 1.5m




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 8 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          4 TEST TYPES AND RESULTS

          4.1 CONDUCTED EMISSION MEASUREMENT

          4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT
             FREQUENCY OF EMISSION (MHz)                                  CONDUCTED LIMIT (dBµV)

                                                                   Quasi-peak                             Average
                             0.15 ~ 0.5                              66 to 56                             56 to 46
                              0.5 ~ 5                                  56                                   46
                               5 ~ 30                                  60                                   50
           NOTE: 1.The lower limit shall apply at the transition frequencies.
                    2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
                        0.50MHz.
                    3. All emanations from a class A/B digital device or system, including any network of
                       conductors and apparatus connected thereto, shall not exceed the level of field
                       strengths specified above.



          4.1.2 TEST INSTRUMENTS
         Equipment                        Manufacturer           Model No.      Serial No.       Last Cal.           Next Cal.
         EMI Test Receiver                Rohde&Schwarz          ESU 26         100005           May 14,13           May 13,14
         Artificial Mains Network         Rohde&Schwarz          ENV216         101173           May 14,13           May 13,14
         Artificial Mains Network         Rohde&Schwarz          ESH3-Z5        100317           May 14,13           May 13,14
                                                                 ADT_Cond
         Test software                    ADT                             N/A                    N/A                 N/A
                                                                 _V7.3.7

          NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations
                   are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.


                   2. The test was performed in Shielding Room 553.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 9 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062



          4.1.3 TEST PROCEDURES

            a. The EUT was placed 0.4 meters from the conducting wall of the shielded room
               with EUT being connected to the power mains through a line impedance
               stabilization network (LISN). Other support units were connected to the power
               mains through another LISN. The two LISNs provide 50 ohm/ 50uH of
               coupling impedance for the measuring instrument.

            b. Both lines of the power mains connected to the EUT were checked for
               maximum conducted interference.

            c. The frequency range from 150kHz to 30MHz was searched. Emission levels
               under (Limit - 20dB) were not recorded.

           NOTE: All modes of operation were investigated and the worst-case emissions are reported.




          4.1.4 DEVIATION FROM TEST STANDARD


           No deviation.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 10 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          4.1.5 TEST SETUP

                                    V e rt ic a l G ro u n d
                                    R e f e re n c e P la n e                                           Te s t R e c e iv e r


                                    EUT
                   40cm




                                                                    80cm
                   L IS N



                                                                                   H o riz o n ta l G ro u n d
                                                                                    R e fe re n c e P la n e

                    N o te : 1 .S u p p o r t u n its w e re c o n n e c te d t o s e c o n d L IS N .
                              2 .B o th o f L IS N s ( A M N ) a re 8 0 c m f ro m E U T a n d a t le a s t 8 0
                                fr o m o t h e r u n its a n d o t h e r m e ta l p la n e s



           For the actual test configuration, please refer to the attached file (Test Setup
           Photo).



          4.1.6 EUT OPERATING CONDITIONS

          Set the EUT under transmission condition continuously at specific channel
          frequency.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                               Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                                Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                                Page 11 of 33                                                     Report Version 1


                      Test Report No.: RF131014N062


          4.1.7 TEST RESULTS

             CONDUCTED WORST-CASE DATA: GFSK DH5
            PHASE                   Line 1                            6dB BANDWIDTH                  9kHz



                              Corr. Reading Value Emission Level             Limit             Margin
                      Freq.
             No              Factor     [dB  (uV)]         [dB (uV)]       [dB (uV)]             (dB)
                      [MHz]
                              (dB)
                                      Q.P.      AV.      Q.P.     AV.    Q.P.      AV.      Q.P.      AV.
              1  0.18128 10.57 33.08 19.28 43.65 29.85 64.43 54.43 -20.78 -24.58
              2  0.32272 10.44 25.34 19.41 35.78 29.85 59.64 49.64 -23.85 -19.78
              3  0.53709 10.29 19.52           12.4     29.81 22.69 56.00 46.00 -26.19 -23.31
              4  1.04539      9.91   19.18 12.64 29.09 22.55 56.00 46.00 -26.91 -23.45
              5  3.33665      9.83   23.06 14.71 32.89 24.54 56.00 46.00 -23.11 -21.46
              6 23.13298 10.28 28.73 21.01 39.01 31.29 60.00 50.00 -20.99 -18.71
           REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                    2. "-": The Quasi-peak reading value also meets average limit and
                       measurement with the average detector is unnecessary.
                    3. The emission levels of other frequencies were very low against the limit.
                    4. Margin value = Emission level - Limit value
                    5. Correction factor = Insertion loss + Cable loss
                    6. Emission Level = Correction Factor + Reading Value.




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                             Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                              Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 12 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


            PHASE                   Neutral                            6dB BANDWIDTH                  9kHz



                              Corr. Reading Value Emission Level             Limit              Margin
                      Freq.
              No             Factor     [dB (uV)]          [dB (uV)]       [dB (uV)]             (dB)
                      [MHz]
                              (dB)
                                      Q.P.       AV.     Q.P.      AV.   Q.P.      AV.      Q.P.      AV.
             1   0.18122 10.47        34.2     19.18 44.67 29.65 64.43 54.43 -19.76 -24.78
             2   0.24407 10.37 27.88 14.61 38.25 24.98 61.96 51.96 -23.71 -26.98
             3   0.30249 10.45 24.37 14.32 34.82 24.77 60.17 50.17 -25.36 -25.41
             4   0.36114 10.47 21.05 11.69 31.52 22.16 58.70 48.70 -27.18 -26.54
             5   3.34447      9.63   22.29 14.06 31.92 23.69 56.00 46.00 -24.08 -22.31
             6  21.87787 10.23 29.53 21.75 39.76 31.98 60.00 50.00 -20.24 -18.02
          REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                   2. "-": The Quasi-peak reading value also meets average limit and
                       measurement with the average detector is unnecessary.
                   3. The emission levels of other frequencies were very low against the limit.
                   4. Margin value = Emission level - Limit value
                   5. Correction factor = Insertion loss + Cable loss
                   6. Emission Level = Correction Factor + Reading Value.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                               Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 13 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062



          4.2 RADIATED EMISSION MEASUREMENT

          4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT
          Emissions radiated outside of the specified bands, shall be according to the general
          radiated limits in 15.209 as following:
                     FREQUENCIES                 FIELD STRENGTH                  MEASUREMENT DISTANCE
                        (MHz)                    (microvolts/meter)                    (meters)
                       0.009 ~ 0.490                  2400/F(kHz)                                   300
                       0.490 ~ 1.705                 24000/F(kHz)                                    30
                        1.705 ~ 30.0                        30                                       30
                           30 ~ 88                         100                                        3
                          88 ~ 216                         150                                        3
                         216 ~ 960                         200                                        3
                         Above 960                         500                                        3


             According to §15.249(a), the field strength of emissions from intentional radiators
             operated within these frequency bands shall comply with the following:
                     Fundamental                     Field strength of                      Field strength of
                      Frequency                        fundamental                             harmonics
                                                    (milli-volts/meter)                    (micro-volts/meter)
                     902-928 MHz                              50                                          500
                  2400-2483.5 MHz                             50                                          500
                   5725-5875 MHz                              50                                          500
                   24.0-24.25 GHz                             250                                      2500
             The emission limit in this paragraph is based on measurement instrumentation
             employing an average detector. The provisions in §15.35 for limiting peak
             emissions apply.
          NOTE:
              1. The lower limit shall apply at the transition frequencies.
              2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
              3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                 average detector, however, the peak field strength of any emission shall not exceed the
                 maximum permitted average limits, specified above by more than 20dB under any condition
                 of modulation.



                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 14 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062

          4.2.2 TEST INSTRUMENTS


            Equipment               Manufacturer          Model No.          Serial No.         Last Cal.            Next Cal.
            Spectrum Analyzer       Agilent       E4446A                     MY46180622         April 24,13          April 23,14
            EMI Test Receiver       Rohde&Schwarz ESVD                       847398/003         May 14,13            May 13,14
            Bilog Antenna
                                    Teseq                 CBL 6111D          25757              Nov. 22,12           Nov. 21,13
            (20MHz-2GHz)
            Horn Antenna
                                    EMCO                  3117               00062558           Oct.18,12            Oct.17,14
            (1GHz -18GHz)
            Pre-Amplifier
                                    EMCI                  EMC 330            980095             Nov. 02,12           Nov.01,13
            (20MHz-3GHz)
            Pre-Amplifier
                                    Agilent               8449B              3008A00409         May 14,13            May 13,14
            (100MHz-26.5GHz)
            Horn Antenna
                                    SCHWARZBECK BBHA 9170                    BBHA9170242 Jan. 04,11                  Jan. 03,14
            (15GHz-40GHz)
            Pre-Amplifier
                                    EMCI                  EMC 184045         980102             Nov. 04,12           Nov. 03,13
            (18GHz-40GHz)
            10m Semi-anechoic                             21.4m*12.1m*8
                                    CHANGLING                           NSEMC006   Mar. 24,13                        Mar. 23,14
            Chamber                                       .8m
            Digital Multimeter      FLUKE                 15B           A1220010DG Oct. 31,12                        Oct. 30,13
            Loop antenna
                                    Daze                  ZN30900A           0708               Nov. 28,12           Nov. 27,13
            (9kHz~30MHz)
            Pre-Amplifier
                                    SONOMA                310D               186955             Mar. 06,13           Mar. 05,14
            (9kHz~1GHz)
                                                          ADT_Radiated
            Test Software           ADT                                N/A                      N/A                  N/A
                                                          _V7.6.15

            NOTE:
            1. The calibration interval of the above test instruments is 12 months or 24 months and the
                calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
            2. The test was performed in 10m Chamber
            3. The FCC Site Registration No. is 502831




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                               Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 15 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062



          4.2.3 TEST PROCEDURES


           a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
              at a 10 meters semi-anechoic chamber. The table was rotated 360 degrees to
              determine the position of the highest radiation.
           b. The EUT was set 3 meters away from the interference-receiving antenna,
              which was mounted on the top of a variable-height antenna tower.
           c. The antenna is a broadband antenna, and its height is varied from one meter to
              four meters above the ground to determine the maximum value of the field
              strength. Both horizontal and vertical polarizations of the antenna are set to
              make the measurement.
           d. For each suspected emission, the EUT was arranged to its worst case and then
              the antenna was tuned to heights from 1 meter to 4 meters and the rotatable
              table was turned from 0 degrees to 360 degrees to find the maximum reading.
           e. The test-receiver/spectrum system was set to Peak Detect Function and
              Specified Bandwidth with Maximum Hold Mode.
           f. If the emission level of the EUT in peak mode was lower than the limit specified,
              then testing could be stopped and the peak values of the EUT would be
              reported. Otherwise the emissions would be re-tested one by one using peak,
              quasi-peak or average method as specified and then reported in a data sheet.

           NOTE:
           1    The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz
                for Quasi-peak detection at frequency below 1GHz.

           2    The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is
                3MHz for Peak detection at frequency above 1GHz.

           3    Bluetooth duty factor correction is not correct as it is based on 79 channels, worst casde would
                be with AFH enabled and device using the minimum of 20 channels. In this case the dwell
                time for a DH5 packet is 0.625 * 5 per 75ms, (assuming one DH5 packet transmitted and
                then a DH1 packet received, 20 channels to cycle through would take 75ms on average before
                repeating a channel) so in any 100ms there would be, on average, two DH5 packets = 6.25ms
                per 100ms
                Therefore, the duty cycle correlation factor be equal to: 20log(6.25 / 100)= -24.1 dB.
                Average value = peak reading + 20log(duty cycle).

           4    All modes of operation were investigated and the worst-case emissions are reported.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 16 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062

          4.2.4 DEVIATION FROM TEST STANDARD

           No deviation


          4.2.5 TEST SETUP


                                                                  Ant. Tower
                                                                                               1-4m
                                                  3m
                               EUT

                                           Turn Table

                        0.8m


                                                Ground Plane

                                               Spectrum




          For the actual test configuration, please refer to the attached file (Test Setup
          Photo).



          4.2.6 EUT OPERATING CONDITIONS
           The software provided by client to enable the EUT under transmission
           condition continuously at lowest, middle and highest channel frequencies
           individually.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 17 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          4.2.7 TEST RESULTS
          BELOW 1GHz WORST-CASE DATA: GFSK DH5

          CHANNEL                     Channel 0                  DETECTOR
                                                                                                   Quasi-Peak (QP)
                                                                 FUNCTION
          FREQUENCY RANGE             30MHz ~ 1GHz


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1      38.08        19.9 QP     40.0         -20.2         1.00 H             269             4.35             15.50
            2      60.72        18.5 QP     40.0         -21.6         1.00 H             256            10.26              8.19
            3      159.33       19.1 QP     43.5         -24.4         1.00 H             244             7.22             11.85
            4      432.55       19.0 QP     46.0         -27.0         1.00 H             228            -0.28             19.29
            5      474.58       21.6 QP     46.0         -24.4         1.00 H             202             1.21             20.35
            6      524.70       21.8 QP     46.0         -24.2         1.00 H             215             0.64             21.18
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. For the test results, the EUT had been tested from 9KHz ~25GHz. But only the worst
                    case was shown in test report.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 18 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062



          CHANNEL                     TX Channel 0               DETECTOR
                                                                                                     Quasi-Peak (QP)
                                                                 FUNCTION
          FREQUENCY RANGE             30MHz ~ 1GHz


                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE                 RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE                VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)              (dBuV)           (dB/m)
            1      30.00        29.4 QP     40.0         -10.6         1.00 V             96                9.39             20.02
            2      57.48        31.5 QP     40.0          -8.5         1.00 V             66               22.59              8.88
            3      159.33       30.3 QP     43.5         -13.2         1.00 V             111              18.49             11.85
            4      474.58       21.9 QP     46.0         -24.1         1.00 V             27                1.51             20.35
            5      536.02       31.1 QP     46.0         -14.9         1.00 V             125               9.23             21.90
            6      615.23       22.0 QP     46.0         -24.1         1.00 V             2                -1.57             23.52
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. For the test results, the EUT had been tested from 9KHz ~25GHz. But only the worst
                    case was shown in test report.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie       Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                             Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 19 of 33                                                           Report Version 1


                      Test Report No.: RF131014N062


          ABOVE 1GHz WORST-CASE DATA: GFSK DH5
          EUT TEST CONDITION                                     MEASUREMENT DETAIL

          CHANNEL                     Channel 0                  FREQUENCY RANGE                   1 ~ 25GHz

                                                                 DETECTOR                          Peak (PK)
          TEST VOLTAGE                DC 3.7V
                                                                 FUNCTION                          Average (AV)


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1     2390.00       42.5 PK     74.0         -31.5         1.00 H             287            28.13             14.37
            2     2390.00       18.4 AV     54.0         -35.6         1.00 H             287             4.03             14.37
            3     2400.00       53.6 PK     74.0         -20.4         1.00 H             287            39.19             14.41
            4     2400.00       29.5 AV     54.0         -24.5         1.00 H             287            15.09             14.41
            5    *2402.00       92.7 PK    114.0         -21.3         1.00 H             287            78.28             14.42
            6    *2402.00       68.6 AV     94.0         -25.4         1.00 H             287            54.18             14.42
            7     4804.00       52.6 PK     74.0         -21.4         1.00 H             252            29.57             23.03
            8     4804.00       28.5 AV     54.0         -25.5         1.00 H             252             5.47             23.03
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1     2390.00       40.3 PK     74.0         -33.7         1.09 V             179            21.89             18.41
            2     2390.00       16.2 AV     54.0         -37.8         1.09 V             179            -2.21             18.41
            3     2400.00       63.2 PK     74.0         -10.8         1.09 V             179            44.69             18.51
            4     2400.00       39.1 AV     54.0         -14.9         1.09 V             179            20.59             18.51
            5    *2402.00       92.7 PK    114.0         -21.3         1.09 V             179            74.17             18.53
            6    *2402.00       68.6 AV     94.0         -25.4         1.09 V             179            50.07             18.53
            7     4804.00       54.2 PK     74.0         -19.8         1.00 V             100            28.44             25.76
            8     4804.00       30.1 AV     54.0         -23.9         1.00 V             100             4.34             25.76
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. " * ": Fundamental frequency.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 20 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062



          EUT TEST CONDITION                                     MEASUREMENT DETAIL

          CHANNEL                     Channel 39                 FREQUENCY RANGE                   1 ~ 25GHz

                                                                 DETECTOR                          Peak (PK)
          TEST VOLTAGE                DC 3.7V
                                                                 FUNCTION                          Average (AV)


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2441.00       94.4 PK    114.0         -19.6         1.00 H             287            57.53             36.87
            2    *2441.00       70.3 AV     94.0         -23.7         1.00 H             287            33.43             36.87
            3     4882.00       53.3 PK     74.0         -20.7         1.00 H             152             4.07             49.23
            4     4882.00       29.2 AV     54.0         -24.8         1.00 H             152           -20.03             49.23
            5     7323.00       54.4 PK     74.0         -19.6         1.00 H             210             7.79             46.61
            6     7323.00       30.3 AV     54.0         -23.7         1.00 H             210           -16.31             46.61
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2441.00       92.8 PK    114.0         -21.2         1.00 V             125            73.88             18.92
            2    *2441.00       68.7 AV     94.0         -25.3         1.00 V             125            49.78             18.92
            3     4882.00       55.5 PK     74.0         -18.5         1.00 V             250            29.64             25.86
            4     4882.00       31.4 AV     54.0         -22.6         1.00 V             250             5.54             25.86
            5     7323.00       56.1 PK     74.0         -17.9         1.00 V             114            26.35             29.75
            6     7323.00       32.0 AV     54.0         -22.0         1.00 V             114             2.25             29.75
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. " * ": Fundamental frequency.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 21 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062


          EUT TEST CONDITION                                     MEASUREMENT DETAIL

          CHANNEL                     Channel 78                 FREQUENCY RANGE                   1 ~ 25GHz

                                                                 DETECTOR                          Peak (PK)
          TEST VOLTAGE                DC 3.7V
                                                                 FUNCTION                          Average (AV)


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2480.00       93.2 PK    114.0         -20.8         1.00 H             325            78.47             14.73
            2    *2480.00       69.1 AV     94.0         -24.9         1.00 H             325            54.37             14.73
            3     2483.50       49.5 PK     74.0         -24.5         1.00 H             325            34.76             14.74
            4     2483.50       25.4 AV     54.0         -28.6         1.00 H             325            10.66             14.74
            5     4960.00       58.1 PK     74.0         -15.9         1.02 H             300            34.50             23.60
            6     4960.00       34.0 AV     54.0         -20.0         1.02 H             300            10.40             23.60
            7     7440.00       56.4 PK     74.0         -17.6         1.00 H             295            26.66             29.74
            8     7440.00       32.3 AV     54.0         -21.7         1.00 H             295             2.56             29.74
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2480.00       94.2 PK    114.0         -19.8         1.03 V             176            74.89             19.31
            2    *2480.00       70.1 AV     94.0         -23.9         1.03 V             176            50.79             19.31
            3     2483.50       50.4 PK     74.0         -23.6         1.03 V             176            31.05             19.35
            4     2483.50       26.3 AV     54.0         -27.7         1.03 V             176             6.95             19.35
            5     4960.00       57.5 PK     74.0         -16.5         1.00 V             214            31.54             25.96
            6     4960.00       33.4 AV     54.0         -20.6         1.00 V             214             7.44             25.96
            7     7440.00       55.5 PK     74.0         -18.5         1.00 V             195            25.41             30.09
            8     7440.00       31.4 AV     54.0         -22.6         1.00 V             195             1.31             30.09
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. " * ": Fundamental frequency.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 22 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062

          BT_8DPSK DH5
          EUT TEST CONDITION                                     MEASUREMENT DETAIL

          CHANNEL                     Channel 0                  FREQUENCY RANGE                   1 ~ 25GHz

                                                                 DETECTOR                          Peak (PK)
          TEST VOLTAGE                DC 3.7V
                                                                 FUNCTION                          Average (AV)


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1     2390.00       43.5 PK     74.0         -30.5         1.00 H             85             29.13             14.37
            2     2390.00       19.4 AV     54.0         -34.6         1.00 H             85              5.03             14.37
            3     2400.00       58.8 PK     74.0         -15.2         1.00 H             65             44.39             14.41
            4     2400.00       34.7 AV     54.0         -19.3         1.00 H             65             20.29             14.41
            5    *2402.00       90.5 PK    114.0         -23.5         1.00 H             256            76.08             14.42
            6    *2402.00       66.4 AV     94.0         -27.6         1.00 H             256            51.98             14.42
            7     4804.00       53.5 PK     74.0         -20.5         1.00 H             322            30.47             23.03
            8     4804.00       29.4 AV     54.0         -24.6         1.00 H             322             6.37             23.03
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1     2390.00       46.6 PK     74.0         -27.4         1.07 V             180            28.19             18.41
            2     2390.00       22.5 AV     54.0         -31.5         1.07 V             180             4.09             18.41
            3     2400.00       60.1 PK     74.0         -13.9         1.07 V             180            41.59             18.51
            4     2400.00       26.0 AV     54.0         -28.0         1.07 V             180             7.49             18.51
            5    *2402.00       92.2 PK    114.0         -21.8         1.07 V             180            73.67             18.53
            6    *2402.00       68.1 AV     94.0         -25.9         1.07 V             180            49.57             18.53
            7     4804.00       54.4 PK     74.0         -19.6         1.00 V             211            28.64             25.76
            8     4804.00       30.3 AV     54.0         -23.7         1.00 V             211             4.54             25.76
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. " * ": Fundamental frequency.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 23 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062



          EUT TEST CONDITION                                     MEASUREMENT DETAIL

          CHANNEL                     Channel 39                 FREQUENCY RANGE                   1 ~ 25GHz

                                                                 DETECTOR                          Peak (PK)
          TEST VOLTAGE                DC 3.7V
                                                                 FUNCTION                          Average (AV)


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2441.00       91.1 PK    114.0         -22.9         1.00 H             288            76.52             14.58
            2    *2441.00       67.0 AV     94.0         -27.0         1.00 H             288            52.42             14.58
            3     4882.00       52.7 PK     74.0         -21.3         1.00 H             211            29.39             23.31
            4     4882.00       28.6 AV     54.0         -25.4         1.00 H             211             5.29             23.31
            5     7323.00       54.1 PK     74.0         -19.9         1.00 H             200            24.60             29.50
            6     7323.00       30.0 AV     54.0         -24.0         1.00 H             200             0.50             29.50
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2441.00       92.5 PK    114.0         -21.5         1.00 V             254            73.58             18.92
            2    *2441.00       68.4 AV     94.0         -25.6         1.00 V             254            49.48             18.92
            3     4882.00       53.4 PK     74.0         -20.6         1.00 V             350            27.54             25.86
            4     4882.00       29.3 AV     54.0         -24.7         1.00 V             350             3.44             25.86
            5     7323.00       54.6 PK     74.0         -19.4         1.00 V             300            24.85             29.75
            6     7323.00       30.5 AV     54.0         -23.5         1.00 V             300             0.75             29.75
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.
                 5. " * ": Fundamental frequency.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 24 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062



          EUT TEST CONDITION                                     MEASUREMENT DETAIL

          CHANNEL                     Channel 78                 FREQUENCY RANGE                   1 ~ 25GHz

                                                                 DETECTOR                          Peak (PK)
          TEST VOLTAGE                DC 3.7V
                                                                 FUNCTION                          Average (AV)


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2480.00       93.2 PK    114.0         -20.8         1.00 H             316            78.47             14.73
            2    *2480.00       69.1 AV     94.0         -24.9         1.00 H             316            54.37             14.73
            3     2483.50       49.3 PK     74.0         -24.7         1.00 H             316            34.56             14.74
            4     2483.50       25.2 AV     54.0         -28.8         1.00 H             316            10.46             14.74
            5     4960.00       54.2 PK     74.0         -19.8         1.00 H             120            30.60             23.60
            6     4960.00       30.1 AV     54.0         -23.9         1.00 H             120             6.50             23.60
            7     7440.00       55.4 PK     74.0         -18.6         1.00 H             230            25.66             29.74
            8     7440.00       31.3 AV     54.0         -22.7         1.00 H             230             1.56             29.74
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA         TABLE               RAW          CORRECTION
                   FREQ.                    LIMIT      MARGIN
          NO.                  LEVEL                                  HEIGHT         ANGLE              VALUE           FACTOR
                   (MHz)                  (dBuV/m)      (dB)
                              (dBuV/m)                                  (m)         (Degree)            (dBuV)           (dB/m)
            1    *2480.00       92.4 PK    114.0         -21.6         1.00 V             320            73.09             19.31
            2    *2480.00       68.3 AV     94.0         -25.7         1.00 V             320            48.99             19.31
            3     2483.50       48.2 PK     74.0         -25.8         1.00 V             314            28.85             19.35
            4     2483.50       24.1 AV     54.0         -29.9         1.00 V             314             4.75             19.35
            5     4960.00       54.8 PK     74.0         -19.2         1.00 V             125            28.84             25.96
            6     4960.00       30.7 AV     54.0         -23.3         1.00 V             125             4.74             25.96
            7     7440.00       51.1 PK     74.0         -22.9         1.00 V             140            21.01             30.09
            8     7440.00       27.0 AV     54.0         -27.0         1.00 V             140            -3.09             30.09
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.5. " * ": Fundamental frequency.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 25 of 33                                                         Report Version 1


                      Test Report No.: RF131014N062


          4.3 20dB BANDWIDTH MEASUREMENT

          4.3.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT

          According to FCC 15.215(c), must be designed to ensure that the 20 dB bandwidth
          of the emission, or whatever bandwidth may otherwise be specified in the specific
          rule section under which the equipment operates, is contained within the frequency
          band designated in the rule section under which the equipment is operated.

          4.3.2 TEST INSTRUMENTS

             Equipment              Manufacturer       Model No.          Serial No.        Last Cal.            Next Cal.
             Signal Analyzer        Rohde&Schwarz FSV7                    102331            Nov. 26,12           Nov. 25,13
             Spectrum Analyzer
                                    Agilent            E7405A             MY45118807 May 14,13                   May 13,14
             (9KHz-25GHz)
                                                                          A1220010D
             Digital Multimeter     FLUKE              15B                                  Oct. 31,12           Oct. 30,13
                                                                          G
             Bluetooth tester       Rohde&Schwarz CBT                     100325            N/A                  N/A

            NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations
                   are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                    2. The test site was performed in Oven room


          4.3.3 TEST PROCEDURE
            a. Check the calibration of the measuring instrument using either an internal
               calibrator or a known signal from an external generator.
            b. Turn on the EUT and connect it to measurement instrument. Then set it to any
               one convenient frequency within its operating range. Set a reference level on
               the measuring instrument equal to the highest peak value.
            c. Measure the frequency difference of two frequencies that were attenuated
               20dB from the reference level. Record the frequency difference as the
               emission bandwidth.
            d. Repeat above procedures until all frequencies measured were complete.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 26 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062

          4.3.4 DEVIATION FROM TEST STANDARD

           No deviation.



          4.3.5 TEST SETUP


                          EUT                                                   SPECTRUM

                                                      10dB ATTENUATION           ANALYZER
                                                      PAD




          4.3.6 EUT OPERATING CONDITIONS

           The software provided by client to enable the EUT under transmission
           condition continuously at lowest, middle and highest channel frequencies
           individually.

          4.3.7 TEST RESULTS

          GFSK DH5

                                                  CHANNEL FREQUENCY                  20dB BANDWIDTH
                               CHANNEL
                                                        (MHz)                             (MHz)


                                     Low                       2402                           0.932

                                    Middle                     2441                           0.932

                                    High                       2480                           0.929




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                             Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                              Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 27 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          Test Data: Low channel




          Test Data: Middle channel




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 28 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


           Test Data: High channel




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 29 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          8DPSK DH5



                                                  CHANNEL FREQUENCY                  20dB BANDWIDTH
                               CHANNEL
                                                        (MHz)                             (MHz)


                                     Low                       2402                            1.26

                                    Middle                     2441                            1.25

                                    Hight                      2480                            1.25




           Test Data: Low channel




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                             Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                              Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 30 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          Test Data: Middle channel




          Test Data: High channel




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 31 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          5     PHOTOGRAPHS OF THE TEST CONFIGURATION

           Please refer to the attached file (Test Setup Photo).




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 32 of 33                                                       Report Version 1


                      Test Report No.: RF131014N062


          6     APPENDIX A - MODIFICATIONS RECORDERS FOR
                ENGINEERING CHANGES TO THE EUT BY THE LAB

           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 33 of 33                                                       Report Version 1



Document Created: 2013-12-04 11:23:20
Document Modified: 2013-12-04 11:23:20

© 2024 FCC.report