MOUNTING                                                   CONNECT NETWORK EXTENDER PRODUCT MANUAL

 1 NOTE: This device is for commercial use only. It is not       2 Install the power supply and power up the Network
     intended or suitable for any consumer applications.            Extender. The Status LED will cycle through Red, Green,
     NOTE: This device requires professional installation           Blue, flash briefly, then turn Green. After a few seconds
     to prevent tampering with or removal/replacement of            the LED will switch to solid Red, indicating that it has not
     the antenna by anyone other than qualified service             been provisioned.
     professionals.
     Choose an appropriate location, preferably on/in the
     ceiling, typically at least 50 feet from the MTI Connect™
     Hub. Secure the Network Extender with included screws
     OR with VHB.




                           OR



                                                                                 Use only the power supply provided
                                                                                 with the Network Extender

                                                                 3 Place the Connect Hub in provisioning mode by inserting
            Main Plug of the adapter acts as disconnect             a Connect Unified IntelliKey into the USB Mini connector
            device, the socket-outlet shall be installed near       on the top of the Connect Hub. After 10 seconds the
            the equipment and shall be easily accessible.           System Status LED will begin flashing blue, indicating the
                                                                    Hub is in Provisioning mode.
    Warning: The Adapter used must be marked with “LPS”
    or “Limited Power Sources”; otherwise those others are
    prohibited to use.

            La prise principale de l’adaptateur agit comme
            un dispositif de déconnexion, la prise de
            courant doit être installée près de l’équipement
            et doit être facilement accessible.
    Avertissement: L’adaptateur utilisé doit porter la
                                                                                                                   System
    mention «LPS» ou «Sources d’alimentation limitées».
                                                                                                                   Status LED
    sinon, ces autres sont interdits d’utilisation.




www.mtigs.com | T:800.426.6844                                                     MTI P/N 063-00289 rev A ©2019 MTI All Rights Reserved
                                                                                                                                      1


NETWORK PROVISIONING                                       CONNECT NETWORK EXTENDER PRODUCT MANUAL

 1 Press the recessed Provisioning Button (1) shown below for two seconds. The Network Extender Status LED (2) will begin
     flashing blue (see page 3 for LED Status Indicators). Alternately, you can insert a Connect Unified IntelliKey in the USB Mini
     connector on the top of the Network Extender




                                                          2
                                                                    1




              Note: Provisioning mode will time-out after about 1.5 minutes and the LED will return to its previous state.

 2 When the Network Extender attaches to the mesh network, the blue flashing LED will become solid Green. If it does not
     attach to the mesh network, the LED will become solid Red.




                                                       Success!




www.mtigs.com | T:800.426.6844                                                          MTI P/N 063-00289 rev A ©2019 MTI All Rights Reserved
                                                                                                                                           2


LED STATUS INDICATORS                CONNECT NETWORK EXTENDER PRODUCT MANUAL

            Visual Reference        System Status                                 Condition



                                                                Network Extender has no power and backup
                                       No Lights On             battery has been depleted. Reconnect
                                                                Network Extender to power.




                                                                Network Extender is fully functional:
                                  Status LED Solid Green
                                                                –– Mesh network communication is good




                                                                Network Extender is in mesh provisioning
                                 Status LED Flashing Blue
                                                                mode.




                                                                Currently communicating on mesh network,
                                 Status LED Flashing Green      but has had communication issues within the
                                                                last 24 hours.




                                                                No communication with mesh network;
                                   Status LED Solid Red         Either has never been provisioned or has lost
                                                                communication with the mesh network.




                                                                Network Extender is in battery backup mode
                                 Status LED Flashing Red
                                                                and is not communicating with the mesh
                                  once every 10 seconds
                                                                network - connect to power.




                                                                Network Extender is in battery backup mode
                                 Status LED Flashing Green
                                                                and is communicating with the mesh network
                                   once every 10 seconds
                                                                - connect to power.




www.mtigs.com | T:800.426.6844                               MTI P/N 063-00289 rev A ©2019 MTI All Rights Reserved
                                                                                                                3


FCC Statement                                                            CONNECT NETWORK EXTENDER PRODUCT MANUAL

  FCC ID: 2AA2X-16500354
  Model: Network Extender
  FCC Statement

  This device complies with Part 15 of the FCC Rules.
  Caution: If any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
  equipment.
  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference
  received, including interference that may cause undesired operation.
  The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could
  void the user’s authority to operate the equipment.
  The RF Exposure Compliance distance is 20 millimeters.
  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
  limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
  radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
  television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
  of the following measures:
  —Reorient or relocate the receiving antenna.
  —Increase the separation between the equipment and receiver.
  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  —Consult the dealer or an experienced radio/TV technician for help.


  ISED Certification Number: 24439-16500354
  Model: Network Extender
  ISED Statement
  This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following
  two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
  undesired operation of the device.
  CAN ICES-3(B)/NMB-3(B)
  Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence.
  L’exploitation est autorisée aux deux conditions suivantes:
  (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage
  est susceptible de compromettre le fomctionnement du dispositif.
  CAN ICES-3(B)/NMB-3(B)
  The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain
  Canadian information on RF exposure and compliance.
  Le dispositif rencontre l’exemption des limites courantes d’évaluation dans la section 2.5 de RSS 102 et la conformité à l’exposition de RSS-102 rf,
  utilisateurs peut obtenir l’information canadienne sur l’exposition et la conformité de rf.
  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated
  with a minimum distance of 20 millimeters between the radiator and your body.
  Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou émetteur. Cet équipement devrait être installé et
  actionné avec une distance minimum de 20 millimètres entre le radiateur et votre corps.
  Technical Data
  Operating Frequency: 2405 MHz to 2480 MHz
  Operating Temperature: 0°C to 40°C
  Max Power: Less than 20dBm at 2.4 GHz


  Additional Safety Information
  1.   For indoor use only. The apparatus shall not be exposed to water.
  2.   No user replaceable parts inside; refer servicing to manufacturer or qualified service personnel.
  3.   Only use accessories specified by the manufacturer.
  4.   Do not expose to excessive heat sources.
  Disposal: All electrical and electronic products including batteries should be disposed of separately from the municipal waste stream via designated
  collection facilities appointed by the government or the local authorities.




www.mtigs.com | T:800.426.6844                                                                               MTI P/N 063-00289 rev A ©2019 MTI All Rights Reserved
                                                                                                                                                                        4



Document Created: 2019-06-15 03:25:45
Document Modified: 2019-06-15 03:25:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC