Test report-DCD

FCC ID: 2AA2X-15000223

Test Report

Download: PDF
FCCID_4384464

Report Number: 60.790.19.015.01R01




                                                           FCC - TEST REPORT


       Report Number                       :    60.790.19.015.01R01                        Date of Issue                     :         June 20, 2019


       Model                               :    CX FLEX SINGLE-POWER

       Product Type                        :    Merchandise Theft Deterrent System

       Applicant                           :    Mobile Technologies Inc.

       Address                             :    1050 NE 67th Ave, Hillsboro, OR 97124

       Production Facility                 :    HONG KONG ANDROIDS TECHNOLOGY CO.LTD

       Address                             :    Yitoa Technology Industrial Park, Baihua Yuan Rd., The Second
                                                Industrial Area, Guangming Sub-district Office, Guangming New
                                                District, Shenzhen, China



       Test Result                         :    Positive                                  Negative


       Total pages                                              18
       including                           :
       Appendices

    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the
    principles outlined in ISO 17025.

    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions.
    Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this
    model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities
    in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and
    Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from
    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports.

    This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall
    not be reproduced except in full without our written approval




                                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                              Page 1 of 18
                                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                                           518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 1 Table of Contents


 1 Table of Contents............................................................................................................ 2
 2 Description of Equipment Under Test ............................................................................. 3
 3 Summary of Test Standards ........................................................................................... 4
 4 Details about the Test Laboratory ................................................................................... 5
       4.1 Test Equipment Site List ................................................................................................... 6
       4.2 Measurement System Uncertainty .................................................................................... 7
 5 Summary of Test Results ................................................................................................ 8
 6 General Remarks ............................................................................................................ 9
 7 Test Setups ................................................................................................................... 10
       7.1 Radiated test setups 9kHz-30MHz .................................................................................. 10
       7.2 Radiated test setups Below 1GHz................................................................................... 10
       7.3 Radiated test setups Above 1GHz .................................................................................. 10
       7.4 AC Power Line Conducted Emission test setups ............................................................ 11
       7.5 Conducted RF test setups............................................................................................... 11
 8 Emission Test Results .................................................................................................. 12
       8.1 Spurious Radiated Emission ........................................................................................... 12
       8.2 Conducted Emission at AC Power Line........................................................................... 15
       8.3 6dB & 99% Bandwidth .................................................................................................... 17
 9 Appendix A - General Product Information ................................................................... 18




                                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 2 of 18
                                    Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                                      518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 2 Description of Equipment Under Test
  Description of the Equipment Under Test

  Product:                               Merchandise Theft Deterrent System

  Model no.:                             CX FLEX SINGLE-POWER

  FCC ID:                                2AA2X-15000223

  Rating:                                EUT rating: 5.2V DC, 3A
                                         Assist AC/DC adapter:100-240V~1A, 50-60Hz input
                                                               5.2V, 3A DC output

  Frequency:                             125kHz (Tx and Rx)

  Modulation:                            AM


  Auxiliary Equipment Used during Test:
       DESCRIPTION        MANUFACTURER                                  MODEL NO.                             REMARK
       AC/DC adapter EDAC POWER ELEC.                                 EA1018A21-052                    Provided by applicant
          User Card             MTI                                         /                          Provided by applicant

  Auxiliary Software Used during Test:
       DESCRIPTION         SOFTWARE NAME                                     VERSION                               REMARK
              /                    /                                           /                                     /




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 3 Summary of Test Standards
                                     Test Standards
 FCC Part 15 Subpart C 10-1-17 Edition
 Federal Communications Commission, PART 15 — Radio Frequency Devices,
 Subpart C — Unintentional Radiators
All the tests were performed using the procedures from ANSI C63.4(2014) and ANSI C63.10
(2013).




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 4 Details about the Test Laboratory
Site 1
Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13 Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2,
                      Shenzhen 518052, P.R.China
                      FCC Registration Number: 514049

                                                Emission Tests
 Test Item                                                                                                          Test Site
 FCC Part 15 Subpart C
 FCC Title 47 Part 15.205, 15.209 Spurious Radiated Emission                                                        Site 1
 FCC Title 47 Part 15.207 Conduct Emission                                                                          Site 1
 FCC Title 47 Part 15.215 20dB Bandwidth                                                                            Site 1




                                         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 5 of 18
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                              518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




  4.1 Test Equipment Site List

Radiated emission Test – Site 1
         DESCRIPTION              MANUFACTURER                     MODEL NO.                 SERIAL NO.               CAL. DUE DATE
        EMI Test Receiver         Rohde & Schwarz                   ESR 26                     101269                    2019-7-6
          Loop Antenna            Rohde & Schwarz                   HFH2-Z2                    100398                    2019-7-6
  Trilog Super Broadband Test
                                      Schwarzbeck                   VULB 9163                      707                     2019-6-28
            Antenna
          Horn Antenna             Rohde & Schwarz                     HF907                     102294                    2019-6-28
         Pre-amplifier             Rohde & Schwarz                     SCU 18                  102230                      2019-7-6
       Signal Generator            Rohde & Schwarz                     SMY01                839369/005                     2019-7-6
          Attenuator                   Agilent                         8491A                MY39264334                     2019-7-6
   3m Semi-anechoic chamber             TDK                            9X6X6                     ----                      2020-7-7
        Test software              Rohde & Schwarz                     EMC32               Version 9.15.00                   N/A

Conducted Emission Test - Site 1
      DESCRIPTION             MANUFACTURER                        MODEL NO.                  SERIAL NO.               CAL. DUE DATE
     EMI Test Receiver        Rohde & Schwarz                        ESR 3                     101782                    2019-7-6
           LISN               Rohde & Schwarz                       ENV4200                    100249                    2019-7-6
           LISN               Rohde & Schwarz                       ENV432                     101318                    2019-7-6
           LISN               Rohde & Schwarz                       ENV216                     100326                    2019-7-6
            ISN               Rohde & Schwarz                        ENY81                     100177                    2019-7-6
            ISN               Rohde & Schwarz                      ENY81-CA6                   101664                    2019-7-6
                                                                  TK9420(VT94
     High Voltage Probe           Rohde & Schwarz                                              9420-584                    2019-6-30
                                                                      20)
      RF Current Probe          Rohde & Schwarz                      EZ-17                    100816                       2019-6-30
         Attenuator            Shanghai Huaxiang                    TS2-26-3                080928189                       2019-7-6
       Test software            Rohde & Schwarz                      EMC32                 Version9.15.00                     N/A

20dB Bandwidth– Site 1
        DESCRIPTION               MANUFACTURER                     MODEL NO.                 SERIAL NO.                CAL. DUE DATE
        Signal Analyzer           Rohde & Schwarz                    FSV40                     101030                     2019-7-6




                                        TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 6 of 18
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                             518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




  4.2 Measurement System Uncertainty

Measurement System Uncertainty Emissions

                                System Measurement Uncertainty
                             Items                           Extended Uncertainty
         Uncertainty for Radiated Emission in 3m chamber
                                                                                                             4.46dB
                            9kHz-30MHz
         Uncertainty for Radiated Emission in 3m chamber                                            Horizontal: 4.91dB;
                          30MHz-1000MHz                                                              Vertical: 4.89dB;
         Uncertainty for Radiated Emission in 3m chamber                                            Horizontal: 4.80dB;
                        1000MHz-18000MHz                                                             Vertical: 4.79dB;
       Uncertainty for Conducted Emission at AC Power Line
                           150kHz-30MHz
                                                                                                             3.21dB
                   Uncertainty for frequency test                                                           0.6×10-7




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 5 Summary of Test Results
                                                    Emission Tests
FCC Part 15 Subpart C
Test Condition                                                                                           Pages            Test Result
                                                                                                                       Pass Fail N/A

FCC Title 47 Part 15.205, 15.209 Spurious Radiated Emission                                              12-14
FCC Title 47 Part 15.207 Conduct Emission                                                                15-16
FCC Title 47 Part 15.215 20dB Bandwidth                                                                   17




                                         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 8 of 18
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                              518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 6 General Remarks
 Remarks

 This submittal(s) (test report) is intended for FCC ID: 2AA2X-15000223, complies with Section
 15.205, 15.207, 15.209, 15.215 of the FCC Part 15, Subpart C rules.

 The TX and RX frequency range is 125kHz.

 SUMMARY:

 - All tests according to the regulations cited on page 8 were

       - Performed

       - Not Performed

 - The Equipment Under Test

       - Fulfills the general approval requirements.

       - Does not fulfill the general approval requirements.

  Sample Received Date:                          May 20, 2019

  Testing Start Date:                             June 4, 2019

  Testing End Date:                             June 25, 2019




 Reviewed by:                                                          Prepared by:


 ______________________________________                                ____________________________________
               Hosea CHAN                                                              Eric LI
           EMC Project Engineer                                              EMC Senior Project Engineer




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 7 Test Setups

 7.1 Radiated test setups 9kHz-30MHz




 7.2 Radiated test setups Below 1GHz




 7.3 Radiated test setups Above 1GHz




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 7.4 AC Power Line Conducted Emission test setups




 7.5 Conducted RF test setups


                 Spectrum analyzer                                      EUT




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 8 Emission Test Results

 8.1 Spurious Radiated Emission

   EUT:                     CX FLEX SINGLE-POWER                                                            Test Result
   Op Condition:            Operated, TX Mode                                                                 Passed
   Test Specification:      FCC15.205, 15.209                                                                 Not Passed
   Comment:                 120V AC
   Remark:                  9kHz to 30MHz

                Frequency               Result                     Limit              Margin             Detector
                   MHz                 dBµV/m                     dBµV/m               dB               PK/QP/AV
                  0.125                  36.47                    105.67              -69.20                Peak
                  0.250                  35.53                     99.65              -64.12                Peak




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 12 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




  Spurious Radiated Emission

   EUT:                              CX FLEX SINGLE-POWER                                                             Test Result
   Op Condition:                     Operated, TX Mode                                                                  Passed
   Test Specification:               FCC15.205, 15.209                                                                  Not Passed
   Comment:                          120V AC
   Remark:                           30MHz to 1GHz, Antenna: Horizontal


                              70


                              60

                              50
            Level in dBµV/m




                              40

                              30


                              20

                              10


                              0
                              30M    50 60          80 100M                       200           300      400 500                800 1G
                                                                      F re q u e n c y in H z

                                    Frequency         MaxPeak             Limit           Margin           Corr.
                                      (MHz)           (dBµV/m)          (dBµV/m)           (dB)            (dB)
                                      51.097500           19.34              40.00           -20.66           17.9
                                      97.172500           22.70              43.50           -20.80           15.4
                                     166.224375           23.98              43.50           -19.52           14.3
                                     323.061250           23.45              46.00           -22.55           20.6
                                     510.271250           27.76              46.00           -18.24           24.2
                                     943.255000           34.74              46.00           -11.26           30.7




                                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 13 of 18
                                    Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                                      518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




  Spurious Radiated Emission

   EUT:                              CX FLEX SINGLE-POWER                                                             Test Result
   Op Condition:                     Operated, TX Mode                                                                  Passed
   Test Specification:               FCC15.205, 15.209                                                                  Not Passed
   Comment:                          120V AC
   Remark:                           30MHz to 1GHz, Antenna: Vertical


                              70


                              60

                              50
            Level in dBµV/m




                              40

                              30


                              20

                              10


                              0
                              30M    50 60          80 100M                       200           300      400 500                800 1G
                                                                      F re q u e n c y in H z

                                    Frequency         MaxPeak             Limit           Margin           Corr.
                                      (MHz)           (dBµV/m)          (dBµV/m)           (dB)            (dB)
                                      31.212500           27.11              40.00           -12.89           14.1
                                      54.128750           29.33              40.00           -10.67           17.2
                                      88.200000           31.74              43.50           -11.76           13.8
                                      97.596875           33.62              43.50            -9.88           15.5
                                     145.430000           31.41              43.50           -12.09           13.3
                                     728.400000           31.87              46.00           -14.13           27.7




                                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 14 of 18
                                    Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                                      518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 8.2 Conducted Emission at AC Power Line

   EUT:                              CX FLEX SINGLE-POWER                                                             Test Result
   Op Condition:                     Operated, TX Mode                                                                  Passed
   Test Specification:               FCC15.207                                                                          Not Passed
   Comment:                          120V AC
   Remark:                           L Line


                            80

                            70

                            60
            Level in dBµV




                            50

                            40

                            30

                            20

                            10

                            0
                            150k   3 0 0 4 0 05 0 0    8 0 01 M             2M      3M 4M 5M 6             8 10M             20M 30M
                                                                     F re q u e n c y in H z



                                                            Critical_Freqs
                                     Frequency         MaxPeak        Average        Limit      Margin       Corr.
                                        (MHz)           (dBµV)         (dBµV)       (dBµV)       (dB)        (dB)
                                      0.198500           54.87           ---         63.86       -8.99       10.2
                                      0.394000           45.51           ---         57.98      -12.47       10.3
                                      0.690000           41.08           ---         56.00      -14.92       10.3
                                      1.393500           45.75           ---         56.00      -10.25       10.3
                                      2.553500           46.22           ---         56.00       -9.78       10.3
                                      4.978000           42.17           ---         56.00      -13.83       10.4



                                                              Final_Result
                                    Frequency         QuasiPeak        Average        Limit      Margin       Corr.
                                       (MHz)           (dBµV)           (dBµV)       (dBµV)       (dB)        (dB)
                                     0.198500            ---             39.39        53.67      -14.28       10.2
                                     0.198500           52.61             ---         63.67      -11.06       10.2
                                     1.393500            ---             30.84        46.00      -15.16       10.3
                                     1.393500           38.67             ---         56.00      -17.33       10.3
                                     2.553500            ---             31.04        46.00      -14.96       10.3
                                     2.553500           39.54             ---         56.00      -16.46       10.3




                                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 18
                                    Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                                      518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




  Conducted Emission at AC Power Line

   EUT:                              CX FLEX SINGLE-POWER                                                             Test Result
   Op Condition:                     Operated, TX Mode                                                                  Passed
   Test Specification:               FCC15.207                                                                          Not Passed
   Comment:                          120V AC
   Remark:                           N Line


                            80

                            70

                            60
            Level in dBµV




                            50

                            40

                            30

                            20

                            10

                            0
                            150k   3 0 0 4 0 05 0 0    8 0 01 M             2M      3M 4M 5M 6             8 10M             20M 30M
                                                                     F re q u e n c y in H z




                                                            Critical_Freqs
                                     Frequency         MaxPeak        Average        Limit      Margin       Corr.
                                        (MHz)           (dBµV)         (dBµV)       (dBµV)       (dB)        (dB)
                                      0.201500           53.94           ---         63.69       -9.76       10.2
                                      0.330000           44.31           ---         59.45      -15.14       10.3
                                      1.402000           43.31           ---         56.00      -12.69       10.3
                                      2.006000           43.52           ---         56.00      -12.48       10.3
                                      3.510000           42.04           ---         56.00      -13.96       10.4
                                      5.598000           41.76           ---         60.00      -18.24       10.5



                                                              Final_Result
                                    Frequency         QuasiPeak        Average        Limit      Margin       Corr.
                                       (MHz)           (dBµV)           (dBµV)       (dBµV)       (dB)        (dB)
                                     0.201500            ---             37.73        53.55      -15.82       10.2
                                     0.201500           51.36             ---         63.55      -12.19       10.2




                                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 18
                                    Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                                      518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 8.3 6dB & 99% Bandwidth

   EUT:                   CX FLEX SINGLE-POWER                                                              Test Result
   Op Condition:          Operated, TX Mode                                                                   Passed
   Test Specification:    FCC15.215, 20dB&99% Bandwidth                                                       Not Passed
   Comment:               120V AC




                                  Bandwidth                          Measured Value
                                20dB bandwidth                           4.2 kHz
                                99% bandwidth                           13.1 kHz




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 17 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA


Report Number: 60.790.19.015.01R01




 9 Ap p en dix A - G ene ral Pr odu ct I nfo rma tion
                               Radiofrequency radiation exposure evaluation

This exposure evaluation is intended for FCC ID: 2AA2X-15000223.

According to KDB 447498 D01v06 section 4.3.1, For frequencies below 100 MHz and test
separation distances ≤ 50 mm, the Numeric threshold is determined as:

Step a)
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR

Step b)
{[Power allowed at numeric threshold for 50mm in step a)] + [(test separation distance – 50mm) · (f(MHz)/150)]} mW

Step c) 1)
For test separation distances > 50mm and < 200mm, the power threshold at the corresponding test separation distance at
100MHz in step b) is multiplied by [1 + log(100/f(MHz))]

Step c) 2)
For test separation distances ≤ 50mm, the power threshold determined by the equation in c) 1) for 50mm and 100MHz is
multiplied by ½.



>> The fundamental frequency of the EUT is 125kHz, the test separation distance is ≤ 50mm.
   (Manufacturer specified the separation distance is: 20mm)

Step a)
>> Numeric threshold, mW / 50mm * √0.1GHz ≤ 3.0
   Numeric threshold ≤ 474.3mW

Step b)
>> Numeric threshold ≤ 474.3mW + (50mm-50mm * 100MHz/150)
   Numeric threshold ≤ 474.3mW

Step c) 1) & c) 2)
>> Numeric threshold ≤ 474.3mW * [1 + log 100/100MHz] * ½
   Numeric threshold ≤ 237.15mW

>> The transmitter strength of EUT measured is: 36.47 dBµV/m
   The power calculated is 0.0000000885mW
   Which is smaller than the Numeric threshold.
   Therefore, the device is exempt from stand-alone SAR test requirements.




                                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 18