User Manual-Glass Lock

FCC ID: 2AA2X-1500011824

Users Manual

Download: PDF
FCCID_4202552

BATTERY INSTALLATION & WARNING           MTI GLASS DOOR LOCKS™ PRODUCT MANUAL

 1                                        2




 3                                        4




 5                                               Battery Caution
                                                 Risk of explosion if battery is replaced by an incorrect type.
                                                 Dispose of used batteries according to the instructions.
                                                 Remove batteries of uninstalled locks before storing.




www.mobiletechinc.com | T:800.426.6844                      MTI P/N 063-00245 rev B ©2019 MTI All Rights Reserved
                                                                                                                  1


GLASS DOOR LOCK PARTS                                       MTI GLASS DOOR LOCKS™ PRODUCT MANUAL

                                         Thin Glass Door Lock Kit - 185-00427




                                                                      Glass Door Lock Mount for
                                                                        Thin Glass (3-10mm)
                                                                             165-00476




                                                                                                  Battery
                      Glass Door Lock Body


                                                   Keys not included. See Page 6.



                                         Thick Glass Door Lock Kit - 185-00427




                                                                                 Glass Door Lock Mount for
                                                                                  Thick Glass (10-19mm)
                                                                                        165-00477




                                                                                              Battery

                      Glass Door Lock Body


                                                   Keys not included. See Page 6.


www.mobiletechinc.com | T:800.426.6844                                               MTI P/N 063-00245 rev B ©2019 MTI All Rights Reserved
                                                                                                                                        2


GLASS DOOR INSTALLATION & USE                                      MTI GLASS DOOR LOCKS™ PRODUCT MANUAL

 1 Slide the lock mount over the back sliding glass door            2 Tighten the knobs on the back of the mount.
     while it is in its closed position.




                   Space devices at least 4” apart.

 3 Slide the front glass door into its closed position and slide      Using the Glass Door Locks:
     the lock over the lock mount blade.
                                                                      Place the User Card on the lock. Once you hear a click,
                                                                      slide the lock off of the Glass Latch Bracket to slide the
                                                                      glass doors open. Slide the glass doors closed and replace
                                                                      the lock on the Latch Bracket to relock.




www.mobiletechinc.com | T:800.426.6844                                               MTI P/N 063-00245 rev B ©2019 MTI All Rights Reserved
                                                                                                                                        3


KEY SETS (SOLD SEPARATELY)                                        MTI GLASS DOOR LOCKS™ PRODUCT MANUAL


              Key Starter Set –                        User Key Bulk (x5) Pack -                              Connect Card -
                185-00459                                    185-00460                                         401-00008




                                         x1



                                                                  x5                                                 x1

                                         x2

KEY REGISTRATION
 1 Swipe Authorization card to enter          2 Swipe each User card to lock. A               3 Swipe Authorization card again to
     enrollment mode. You will hear                double beep tone indicates a card is            close enrollment mode. Enrollment
     a double beep tone, indicating                now enrolled. Repeat for each user              mode times out after 3 minutes of no
     enrollment mode has been entered.             card, up to 250 user cards. If a card           activity. Lock will emit 4 fast beeps
                                                   fails to be recognized, the lock will           when enrollment has timed out.
                                                   emit 4 fast beeps.




DELETING KEYS
 1 Hold Authorization Card to lock for 5 seconds, and lock           2 Swipe Authorization Card again to lock, within 10
     will start a ticking sound. This enters delete mode.                seconds to clear all keys returning lock to a factory reset
                                                                         state. Lock will emit a double beep, confirming the key
                                                                         whitelist is cleared. It will stop ticking after 10 seconds
                                                                         and resume normal operation if the Authorization Card is
                                                                         not swiped again.




www.mobiletechinc.com | T:800.426.6844                                                     MTI P/N 063-00245 rev B ©2019 MTI All Rights Reserved
                                                                                                                                              4


INITIAL SET UP                                                       MTI GLASS DOOR LOCKS™ PRODUCT MANUAL

  Note:

  Operating temperature: 41-95° F.

  Converting to Connect Lock
  To use the MTI Connect Business Intelligence feature of your MTI locks you must have an internet connection, a MTI Connect
  Hub to create the mesh network, and the MTI Connect Card, which allows you to convert modes. In Connect mode, the lock will
  check in with the Hub every hour, and every time a lock is accessed. During check-in, the Hub will look for new key white list,
  report lock status, battery status, and lock ID.
  1. Hook up Connect Hub to Ethernet or Wifi Connection.
  2. Apply power to Connect Hub, and put into Provisioning mode. This allows the Connect Hub to look for locks trying to enter the
     mesh network. Refer to the instructions that came with the Connect Hub for how to enter provisioning mode.
  3. Swipe MTI Connect card on lock to enter Connect Provisioning mode. The lock will emit a double beep tone, and then emits
     a constant series of slow beeps until it finds the network. When it is connected, it will emit a double beep confirmation tone,
     retrieve the white list of keys from the network, and now operate as a Connect lock. If no network is detected in 1 minute 20
     seconds, the lock will emit four fast beeps, indicating a time out, and revert back to a non-Connect run mode. When lock
     enters Connect mode, it will erase all keys previously programmed to that lock, defaulting to the key whitelist it retrieves from
     the Connect Hub.

  Reverting Connect Lock to Non-Connect
  1. Power down Connect Hub to disable the mesh network. This will ensure the lock is not trying to locate a mesh.
  2. Hold Connect card to lock for 10 seconds. Lock will emit a fast double confirmation beep. After 5 seconds it will emit four fast
     beeps. Lock has reverted to a non-Connect operating mode.
  3. Keys previously whitelisted in Connect mode will still continue to work.

  Factory Reset
  There are several methods to reset a lock to a factory default.
  1. Remove lock from fixture to gain access to reset button on lock. If fixture is stuck closed, proceed to step 3.
  2. Press and hold button on back of lock for 3 seconds until it starts emitting a beeping tone. It will emit beeps for 5 seconds.
     When it stops beeping, lock will be at a factory reset position with the tumbler in the open position.
  3. If lock is not accessible to remove, a factory reset key must be used. With a factory reset key, swipe the lock once, you will hear
     consistent four beep bursts.
  4. Swipe card again within 5 seconds. Allow the lock to set for several seconds, and it will reset itself to a factory reset, with the
     tumbler in the open position. This will remove any key whitelist
  5. Follow whitelist process to program new keys.

  Features
  - Door Open Mode - If a lock has been left open for 5 minutes, the lock will emit a continuous on/off beep tone for 10 minutes or
    until the door is closed.
  - Stuck Lock - If a lock is jammed or unable to unlock, the lock will emit a slow beep tone to indicate that the lock is stuck.
  - Low Battery - If the lock battery is low and needs replacement, the lock will emit a long single beep on every card swipe.
     - Lock will beep every hour when it reaches 10% capacity.
     - Lock will default to the open position when battery reaches 0%
     - Battery health is indicated in Connect App, reported every hour.
                   Correct Disposal of Product
                   This marking indicates that this product should not be disposed with other household wastes throughout the EU.
                   To prevent harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly
                   to promote the sustainable reuse of material resources. To dispose of used devices contact MTI Global Services
                   Contact Center at 503-648-6500 or contact local recycling company for proper recycling instructions for
                   electronic devices.




www.mobiletechinc.com | T:800.426.6844                                                      MTI P/N 063-00245 rev B ©2019 MTI All Rights Reserved
                                                                                                                                               5


FCC Statement                                                        MTI GLASS DOOR LOCKS™ PRODUCT MANUAL


    FCC ID: 2AA2X-15ØØØ11824
    Model: Glass Lock
    FCC STATEMENT
    This device complies with Part 15 of the FCC Rules.
    Caution: If any changes or modifications not expressly approved by the party responsible for compliance could void the user’s
    authority to operate the equipment.
    Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device
    must accept any interference received, including interference that may cause undesired operation.
    The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for
    compliance. Such modifications could void the user’s authority to operate the equipment.
    The RF Exposure Compliance distance is 20 millimeters.
    NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
    of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
    installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
    accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
    that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
    television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
    the interference by one or more of the following measures:
    -   Reorient or relocate the receiving antenna.
    -   Increase the separation between the equipment and receiver.
    -   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    -   Consult the dealer or an experienced radio/TV technician for help.


    ISED Certification Number: 24439-15ØØØ11824
    Model: Glass Lock
    ISED Statement
    This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s).
    Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
    accept any interference, including interference that may cause undesired operation of the device.
    CAN ICES-3(B)/NMB-3(B)
    Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux
    appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
    (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique
    reçu, même si ce brouillage est susceptible de compromettre le fomctionnement du dispositif.
    CAN ICES-3(B)/NMB-3(B)
    The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102
    RF exposure, users can obtain Canadian information on RF exposure and compliance.
    Le dispositif rencontre l’exemption des limites courantes d’évaluation dans la section 2.5 de RSS 102 et la conformité à
    l’exposition de RSS-102 rf, utilisateurs peut obtenir l’information canadienne sur l’exposition et la conformité de rf.
    This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment
    should be installed and operated with a minimum distance of 20 millimeters between the radiator and your body.
    Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou émetteur. Cet
    équipement devrait être installé et actionné avec une distance minimum de 20 millimètres entre le radiateur et votre corps.
    Technical Data
    Operating frequency 125KHz , 2.4GHz : 2405- 2480MHz
    Operating temperature: 0º C to 40º C
    Max power :       125KHz <42dBuA/m at 10m, 2.4GHz < 20 dBm




www.mobiletechinc.com | T:800.426.6844                                                       MTI P/N 063-00245 rev B ©2019 MTI All Rights Reserved
                                                                                                                                                6



Document Created: 2019-09-15 15:56:17