RF exposure

FCC ID: 2AA2X-1500011824

RF Exposure Info

Download: PDF
FCCID_4202543

Report Number: 60.790.18.051.01R02




8 Appendix A - General Product Information
                        Radiofrequency radiation exposure evaluation

This exposure evaluation is intended for FCC ID: 2AA2X-1500011824.

According to KDB 447498 D01v06 section 4.3.1, For frequencies between 100 MHz to 6GHz
and test separation distances 50 mm, the Numeric threshold is determined as:

Step a)
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]
· [ f(GHz)] 3.0 for 1-g SAR

>> The fundamental frequency of the EUT is 2405-2480MHz,
   the test separation distance is 50mm.
   (Manufacturer specified the separation distance is: 20mm)

Step a)
>> Numeric threshold (2405MHz), mW / 20mm * 2.402GHz                                      3.0
   Numeric threshold (2405MHz) 38.713mW

>> Numeric threshold (2445MHz), mW / 20mm * 2.440GHz                                      3.0
   Numeric threshold (2445MHz) 38.411mW

>> Numeric threshold (2480MHz), mW / 20mm * 2.480GHz                                      3.0
   Numeric threshold (2480MHz) 38.100mW

>> The power of EUT measured (2405MHz) is: 2.03dBm = 1.596mW
   The power of EUT measured (2445MHz) is: 2.04dBm = 1.600mW
   The power of EUT measured (2480MHz) is: 2.34dBm = 1.714mW

   Which is smaller than the Numeric threshold.
   Therefore, the device is exempt from stand-alone SAR test requirements.




                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 34 of 35
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
                                                            518052 Shenzhen, CHINA



Document Created: 2019-03-13 14:34:34