Radhaz Analysis

0044-EX-PL-2010 Text Documents

ViaSat, Inc.

2010-01-28ELS_104218

Analysis of Non-Ionizing Radiation for a C-band UAV Antenna System

This report analyzes the non-ionizing radiation levels for a C-band antenna system which
supports UAV communications. Two transmitting antennas are utilized as part of this
system, one for the ground-to-air link and one for the air-to-ground link.

Operation of the transmitting system associated with this antenna system may occur
while the aircraft is on the ground in addition to normal operation in flight. Therefore,
RF radiation may be present while ground crew is servicing the aircraft.

The FCC’s Office of Engineering Technology’s Bulletin No. 65 specifies that there are
two separate tiers of exposure limits that are dependant upon the situation in which the
exposure takes place and/or the status of the individuals who are subject to the exposure.
The two tiers are General Population / Uncontrolled environment, and an Occupational /
Controlled environment.

The applicable exposure limit for the General Population / Uncontrolled environment,
i.e., areas that people may enter freely, at this frequency of operation is 1 mW/cm^2
average power density over a 30 minute period.

The applicable exposure limit for the Occupational / Controlled environment, i.e., areas
that only authorized / trained personnel have access to, at this frequency of operation is 5
mW/cm^2 average power density over a 6 minute period.

Summary of expected radiation levels for an Uncontrolled environment


Air-to-Ground                  Maximum Power Density                 Hazard Assessment

Safe region range ≥ 0.282 m           1.0 mW/cm2                     Satisfies FCC MPE

Ground-to-Air                  Maximum Power Density                 Hazard Assessment

Safe region range ≥ 4.091 m           0.835 mW/cm2                   Satisfies FCC MPE


Summary of expected radiation levels for a Controlled environment


Air-to-Ground                  Maximum Power Density                 Hazard Assessment

Safe region range ≥ 0.126 m           5.0 mW/cm2                     Satisfies FCC MPE

Ground-to-Air                  Maximum Power Density                 Hazard Assessment

Safe region range ≥ 1.704 m           2.809 mW/cm2                   Satisfies FCC MPE



DC\797918.1


Conclusions

Access to the UAV and to the transmitting ground-to-air antenna is controlled and not
available to the general public, and therefore the controlled environment limits apply.

Due to the small distance of 0.126 m (4.96 in) or greater where the exposure limits are
met, it is very unlikely that ground crew will be exposed to non-compliant RF exposure
levels. In the event that maintenance on the UAV requires closer proximity to the
transmitting antenna than 0.126 m, the RF subsystem will be disabled.

Similarly, while operating the ground-to-air transmitter, access will be restricted to
distances greater than 2.809 m.




DC\797918.1


Analysis – C-band Button Antenna

The analysis and calculations that follow in this report are performed in compliance with
the methods described in the OET Bulletin No. 65.

Definition of terms

The terms are used in the formulas here are defined as follows:

Sff = power density in the far field (on axis)
Rff = distance to the beginning of the far-field
R = distance to point of interest
Pa = 5 W                        maximum power amplifier output
Lfs = 0 dB                      loss between power amplifier and antenna feed
P = 5.0 W                       power fed to the antenna in Watts
A = 8.553 cm^2                  physical area of the aperture antenna
G = 2.0                         power gain relative to an isotropic radiator
D = 3.3 cm                      diameter of antenna in meters
F = 4600                        frequency in MHz
λ = 6.517 m                     wavelength in meters (300/FMHz)
η = 0.79                        aperture efficiency


Far-Field Region. The power density on-axis of the far-field or Fraunhofer region of the
antenna pattern decreases inversely as the square of the distance. The distance to the start
of the far field can be calculated by the following equation:


Rff     =
              (0.6 • D )
                      2


                  λ

        =
              (0.6 • 3.3 cm )
                           2


                6.571 cm

        = 10.026 mm




DC\797918.1


The power density at the start of the far-field region of the radiation pattern can be
estimated by the equation:
Sff    =
            (P • G )
              (
          4 • π • R ff
                       2
                             )
        =
                    (5.0 W • 2.0)
              (4 • π • 10.026 mm )  2




                         mW
        = 791.787
                         cm 2


Safe Region for Uncontrolled Access. As given above, the power density on-axis of the
far field region of the antenna pattern decreases inversely as the square of the distance.
The distance to the point where the power density equals the 1 mW/cm2 level can be
determined by the equation:


R1 mW =
                         (P • G )
                  ⎛          mW        ⎞
                  ⎜ 4 • π •1    2
                                  • 10 ⎟
                  ⎝          cm        ⎠


        =
                    (5 W • 2.0)
                  ⎛       mW ⎞
                  ⎜125.66      ⎟
                  ⎝       cm 2 ⎠

        = 0.282 m

Safe Region for Controlled Access. As given above, the power density on-axis of the
far field region of the antenna pattern decreases inversely as the square of the distance.
The distance to the point where the power density equals the 5 mW/cm2 level can be
determined by the equation:


R5mW =
                         (P • G )
                  ⎛        mW        ⎞
                  ⎜4 •π •5    2
                                • 10 ⎟
                  ⎝        cm        ⎠


        =
                   (5 W • 2.0)
                  ⎛       mW ⎞
                  ⎜ 628.3      ⎟
                  ⎝       cm 2 ⎠

        = 0.126 m


DC\797918.1


Analysis – C-band 2 ft (61 cm) Antenna

The analysis and calculations that follow in this report are performed in compliance with
the methods described in the OET Bulletin No. 65.

Definition of terms

The terms are used in the formulas here are defined as follows:

Sff = power density in the far field (on axis)
Rff = distance to the beginning of the far-field
R = distance to point of interest
Pa = 5 W                        maximum power amplifier output
Lfs = 0 dB                      loss between power amplifier and antenna feed
P = 5.0 W                       power fed to the antenna in Watts
A = 0.292 m^2                   physical area of the aperture antenna
G = 501.7                       power gain relative to an isotropic radiator
D = 61 cm                       diameter of antenna in meters
F = 5500                        frequency in MHz
λ = 5.451 m                     wavelength in meters (300/FMHz)
η = 0.41                        aperture efficiency


Far-Field Region. The power density on-axis of the far-field or Fraunhofer region of the
antenna pattern decreases inversely as the square of the distance. The distance to the start
of the far field can be calculated by the following equation:


Rff     =
              (0.6 • D )
                      2


                  λ

        =
              (0.6 • 3716 cm )
                            2


                 5.451cm

        = 4.91 m




DC\797918.1


The power density at the start of the far-field region of the radiation pattern can be
estimated by the equation:
Sff    =
            (P • G )
              (
          4 • π • R ff
                       2
                              )
        =
              (5.0 W • 501.7 )
              (4 • π • 4.91 m )       2




                      mW
        = 0.828
                      cm 2


Safe Region for Uncontrolled Access. Because the power level is just less than 1
mW/cm2 at the start of the far field, the start of the far field will be used as the safe region
for uncontrolled access.


Safe Region for Controlled Access. The power level at the end of the near field (1.7 m)
is 2.81 mW/cm2. Therefore the end of the near field will be used as the safe region for
controlled access:

The range to the end of the near field is calculated by:

           D2
Rnf     =
          4•λ

               3716 cm 2
        =
              4 • 5.451 cm

        = 1.704 m

The power level at the end of the near field is calculated by:

Snf     =
              (16 • η • P )
                  (π • D )
                        2




        =
              (16 • 0.41 • 5 W )
              (π • 3716 cm )      2




                      mW
        = 2.809
                      cm 2