Toggle navigation
FCC.report
IBFS
ELS
FCC ID
Contact
About
FCC.report
›
ELS
›
The MITRE Corporation
›
1346-EX-ST-2016
The MITRE Corporation
1346-EX-ST-2016
Status: Denied/Dismissed
WJ9XOV
2016-10-03
Documents and Communications:
[
refresh
]
Description
Category
Date
E-Mail generated [Sep 14 2016]
Correspondence
2016-09-14
Incoming generated [Oct 5 2016]
Correspondence
2016-10-05
Dismissal Without Prejudice generated [Oct 3 2016]
Correspondence
2016-10-03
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY
Applicant Name
Name of Applicant:
The MITRE Corporation
Address
Attention:
David Winters, M/S S230
Street Address:
202 Burlington Road
P.O. Box:
City:
Bedford
State:
MA
Zip Code:
01730
Country:
E-Mail Address:
[email protected]
Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:
Last Name:
Winters
First Name:
David
Title:
Lead Engineer
Phone Number:
781-271-6287
Explanation
Please explain in the area below why an STA is necessary:
Planning on conducting intermittent outdoor experiments at MITRE campus in Bedford, MA during summer and early fall of 2016.
Purpose of Operation
Please explain the purpose of operation:
Several internally-funded research projects require specific data at multiple frequency bands. These requirements will be fulfilled by conducting several short and intermittent outdoor experiments.
Information
Callsign:
WJ9XOV
Class of Station:
FX MO
Nature of Service:
Experimental
Requested Period of Operation
Operation Start Date:
10/31/2016
Operation End Date:
12/31/2016
Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:
Manufacturer
Model Number
No. Of Units
Experimental
National Instruments
PXIe-5673E
1
No
RF-Lambda
RAMP07G06GE
1
No
K&L Microwave
3C50-2484/T25-O
1
No
K&L Microwave
3C50-2414/T25-O
1
No
L-Com
HG2409RD-SM
1
No
K&L Microwave
3C50-5700/T50-O
1
No
Hobby Wireless
3525-52
1
No
The MITRE Corporation
R-SwapX10.0
1
Yes
MicroSemi
AML0812-50
1
No
K&L Microwave
3C5010000T50-OO
1
No
ATM Microwave
90-444E-6
1
No
Analog Devices
AD9361
2
No
L-Com
HG2400RDR90-RSP
2
No
Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form):
Eric M Renda
Title of Applicant (if any):
Lead Engineer
Date:
2016-09-12 00:00:00.0
Station Location
City
State
Latitude
Longitude
Mobile
Radius of Operation
Bedford
Massachusetts
North 42 30 17
West 71 14 18
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2401.50000000-2426.50000000 MHz
FX
125.000000 mW 1.000000 W
P
0.00000100 %
20M0W7W
OFDM
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2471.50000000-2496.50000000 MHz
FX
125.000000 mW 1.000000 W
P
0.00000100 %
20M0W7W
OFDM
City
State
Latitude
Longitude
Mobile
Radius of Operation
Bedford
Massachusetts
North 42 30 17
West 71 14 18
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
5675.00000000-5725.00000000 MHz
FX
500.000000 mW 1.000000 W
P
0.00000100 %
20M0W7W
OFDM
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
5675.00000000-5725.00000000 MHz
FX
500.000000 mW 1.000000 W
P
0.00000100 %
20M0Q1N
LFM Chirp
City
State
Latitude
Longitude
Mobile
Radius of Operation
Bedford
Massachusetts
North 42 30 18
West 71 14 12
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
77.00
(b) Orientation in horizontal plane:
250.00
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9975.00000000-10025.00000000 MHz
FX
70.800000 mW 1.000000 W
P
0.00000100 %
20M0Q1N
LFM Chirp
City
State
Latitude
Longitude
Mobile
Radius of Operation
Bedford
Massachusetts
North 42 30 17
West 71 14 15
Courtyard at MITRE Bedford campus
0.30
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2401.50000000-2426.50000000 MHz
MO
5.600000 mW 5.600000 mW
P
0.00010000 %
20M0W7W
OFDM
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2471.50000000-2496.50000000 MHz
MO
5.600000 mW 5.600000 mW
P
0.00010000 %
20M0W7W
OFDM
38305
© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC