Systems & Technologies Research

0650-EX-ST-2021

Status: Pending

N/A
2021-04-23

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Apr 23 2021]Correspondence2021-04-23
E-Mail generated [Apr 23 2021]Correspondence2021-04-23
Exhibit FCC Antenna Registration and Directional Antenna InformationText Documents2021-04-23
Incoming generated [Apr 29 2021]Correspondence2021-04-29
Incoming generated [Apr 29 2021]Correspondence2021-04-29
Exhibit Q4 FCC Antenna Registration and Directional Antenna InformationText Documents2021-04-29
Grant E-mail Notification generated [Jun 1 2021]Correspondence2021-06-01
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Systems & Technologies Research

Address
Attention: Susan Bendott
Street Address: 600 West Cummings Park
P.O. Box:
City: Woburn
State: MA
Zip Code: 01801-7222
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Pilyavsky
First Name: Genady
Title: Program Manager
Phone Number: (781) 537-6818

Explanation
Please explain in the area below why an STA is necessary:
leading an effort to design, test, and produce low-cost radar threat emulators which may be employed to provide additional realism to DoD training exercises

Purpose of Operation
Please explain the purpose of operation:  Testing low-cost radar threat emulators. The goal of the SDR-Based Inexpensive Radar Emulator System (SIREN) is to develop a low cost, modular system which can emulate numerous threats at a significantly lower cost than what is commercially available

Information
Callsign: WS9XDH
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 06/01/2021
Operation End Date: 11/30/2021

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
STR SIREN 1 Yes

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Susan D Bendott
Title of Applicant (if any): Contracts Manager
Date: 2021-04-23 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Windham Maine North  43  44  18 West  70  25  27 Windham, ME 1.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   Yes
(a) Width of beam in degrees at the half-power point:   5.00
(b) Orientation in horizontal plane:   328.00
(c) Orientation in vertical plane:   5.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 3.25000000-3.26200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0Q0N LFM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 3.25000000-3.26200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0M3N phase coded
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 3.25000000-3.26200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0P0N unmodulated
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4.75000000-4.76200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0Q0N LFM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4.75000000-4.76200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0M3N phase coded
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4.75000000-4.76200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0P0N unmodulated
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5.90000000-5.91200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0Q0N LFM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5.90000000-5.91200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0M3N phase coded
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5.90000000-5.91200000 GHz MO 450.000000 W 282.000000 kW P 0.00000500 % 12M0P0N unmodulated
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.70000000-8.71200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0Q0N LFM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.70000000-8.71200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0M3N phase coded
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.70000000-8.71200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0P0N unmodulated
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 9.50000000-9.51200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0Q0N LFM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 9.50000000-9.51200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0M3N phase coded
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 9.50000000-9.51200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0P0N unmodulated
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 10.90000000-10.91200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0Q0N LFM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 10.90000000-10.91200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0M3N phase coded
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 10.90000000-10.91200000 GHz MO 200.000000 W 955.000000 kW P 0.00000500 % 12M0P0N unmodulated

40940

© 2024 FCC.report