Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Panasonic Avionics Corporation

Address
Attention: Ms. Anita Kartic
Street Address: 26200 Enterprise Way
P.O. Box:
City: Lake Forest
State: CA
Zip Code: 92630
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Nalda
First Name: Carlos
Title: Attorney
Phone Number: 202-626-6659

Explanation
Please explain in the area below why an STA is necessary:
Panasonic Avionics Corporation (Panasonic) requests a one-month experimental Special Temporary Authority (STA), commencing on or about February 15, 2012, to conduct certification testing of the equipment Panasonic has been using throughout the world to conduct electromagnetic interference (EMI) ground testing of multiple, simulated transmit portable electronic devices (T-PEDs) RF transmissions in the aircraft cabin in multiple frequency bands. These T-PED EMS tests are being conducted in support of Panasonics Global Communications Suite (GCS) featuring the eXConnect Ku-band aeronautical mobile-satellite service (AMSS) system to provide broadband connectivity onboard aircraft in flight. Panasonic has obtained a series of experimental STAs and a two-year experimental license to conduct these tests in multiple locations in the United States. (See, e.g., File No. 0671-EX-ST-2011, Call Sign WF9XGL ? Melbourne, FL; File No. 0225-EX-PL-2010, Call Sign WF2XLF ? four sites: Everett, WA; Victorville, CA; Waco, TX; and Greensboro, NC. Panasonic is working to deploy this system worldwide, including in Japan, and is actively seeking similar authority from the Japanese telecommunications ministry (Ministry of Industry and Communications, or MIC), to conduct T-PED EMI testing onboard in that country. Panasonic has learned that, as a required prerequisite to receiving the necessary authorization to conduct the T-PED EMI testing in Japan, it is first necessary for the test equipment (signal generator, amplifier, antenna) itself be inspected and certified by an authorized entity. What this means practically is that the T-PED EMI test equipment be turned on and calibrated consistent with the proposed T-PED EMI tests. The test equipment will be turned on and shown to be able to tune to the proposed test frequencies and transmit at the proposed transmit power. Due to scheduling and other issues, the intent is to have the Japanese engineering consultant engaged by Panasonic that will test the test equipment come to the United States, specifically to Panasonics test facility at its headquarters in Lake Forest, CA during the requested authorization period of February 15, 2012 to March 15, 2012 There are six frequencies at which Panasonic needs to test the test equipment, all within the 2.4 and 5 GHz Wi-Fi bands: 2412 MHz, 2437 MHz, 2484 MHz, 5170 MHz, 5190 MHz, 5210 MHz and 5230 MHz. The intent is to conduct the test indoors at Panasonics test facility at its headquarters in Lake Forest, CA. The preference would be to conduct the tests of the test equipment in a shielded test enclosure, which Panasonic has constructed and maintained at its Lake Forest facility. However, it appears that this enclosure may not be available during the requested time period. Regardless, the tests will be conducted indoors and shielded to the extent possible. The geographic coordinates of Panasonic?s Lake Forest facility is: 33-40-04 NL; 117-40-31 WL.

Purpose of Operation
Please explain the purpose of operation:  As explained above, the purpose of the requested STA is to provide an opportunity for the Japanese engineering consultant engaged by Panasonic to test the test equipment to be used by Panasonic to conduct its T-PED EMI tests onboard aircraft in Japan to confirm that the test equipment is able to perform the T-PED EMI tests. More formally, the requested STA is sought to facilitate and confirm the completion of the construction of the T-PED EMI testing equipment, as required pursuant to Japanese regulations.

Information
Callsign: WF9XME
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 02/15/2012
Operation End Date: 03/15/2012

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Rohde & Schwarz Signal Generator SMB100A 1 No
Empower RF Systems Amplifier 1131-BBM5K8CGM 1 No
Agilent Signal Generator N/A 1 No
Empower RF Systems Amplifier 1179-BBM3K5KKO 1 No
ETS.Lindgren Antenna 3181 1 No
HyperLOG Calibration Antenna 4060 1 No
Rohde & Schwarz Spectrum Analyzer FWH4/FSH8 1 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Anita Kartic
Title of Applicant (if any): Director, eXConnect Regulatory
Date: 2012-02-08 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Lake Forest California North  33  40  4 West  117  40  31 Mobile/Temporary fixed at applicant's facility 0.10
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 2412.00000000-2412.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 2437.00000000-2437.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 2484.00000000-2484.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5170.00000000-5170.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5190.00000000-5190.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5210.00000000-5210.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5230.00000000-5230.00000000 MHz MO 40.000000 W 37.900000 W P 1M00P0N Pulse