Elevation Sketch Fort Worth Site

0348-EX-ST-2018 Images

Manifest Wireless L.L.C.

2018-02-26ELS_205503

                 PROJECT INFORMATION                                                                                                                                                   APPROVALS
                                                                                                                                                                                                                                                                     
 APPLICANT/LEASSEE:
 NAME:
 ADDRESS:
 CITY, STATE, ZIP:
 CONTACT:
                    AMERICAN TOWER CORPORATION
                    8505 FREEPORT PARKWAY
                   IRVING, TX 75063
                    JERRY FOLK
                                                                                                                                                        CONSTRUCTION MANAGER:                         ENGINEER:                                                      
 PHONE:            IRVING, TX 75063
                                                                                                                                                                                                                                                           Celeris Group Consulting Engineers
                                                                                                                                                        CONSTRUCTION MANAGER:                         CONTRACTOR:                                            2000 E. Lamar Blvd., Suite 550
                                                                                                                                                                                                                                                                   Arlington, TX 76006
 TOWER OWNER:                                                                                                                                                                                                                                                     Phone: 817-446-1700
 NAME:               AMERICAN TOWER CORPORATION                                                                                                                                                                                                                    Fax: 817-460-0677
                                                                                                                                                                                                                                                                  www.celerisgroup.com
 ADDRESS:            8505 FREEPORT PARKWAY
 CITY, STATE, ZIP:   IRVING, TX 75063                                                                                                                   PROPERTY OWNER:                               CONTRACTOR:
 CONTACT:            JERRY FOLK                                                                                                                                                                                                                   Engineer:
 PHONE:              IRVING, TX 75063                                                                                                                                                                                                             Celeris Group Consulting Engineers
                                                                                                                                                                                      SHEET INDEX                                                 2000 E. Lamar Blvd., Suite 550
                                                                                                                                                                                                                                                  Arlington, TX 76006
                                                                                                                                                                                                                                                  Phone: 817-446-1700
                                                                                                                                                          SHEET                                                                   CURRENT
 PROPERTY OWNER:                                                                                                                                                                             SHEET NAME                                           Fax: 817-460-0677
                     AMERICAN TOWER CORPORATION                                                                                                          NUMBER                                                                   REVISION        Registration No: F-13992
 NAME:
 ADDRESS:            10 PRESIDENTIAL WAY                                                                                                                    T01                             TITLE PAGE                               0
                                                                                                                                                                                                                                                  Electrical Engineer:
 CITY, STATE, ZIP:   WOBURN, MA 01801                                                                                                                       N01                          GENERAL NOTES                               0            Torres Engineering Services, Inc.
 CONTACT:            ARLINDO NETO                                                                                                                           C01                         OVERALL SITE PLAN                            0            8237 Delafield Dr.
                     781-926-7185                                                                                                                                                                                                                 Ft. Worth, TX 76131
 PHONE:
                                                                                                                                                            C02                          DETAIL SITE PLAN                            0            Phone: 682-556-0848
                                                                                                                                                                                                                                                  Registration No: F-10147
                                                                                                                                                            C03                         TOWER ELEVATION                              0
                                                                                         SITE NAME                                                          C04                               DETAILS                                0
                                                                                                                                                            C05                           FENCE DETAILS                              0        STAMP:

                                                                    FT. WORTH BROADCAST / 90555                                                             S01
                                                                                                                                                            S02
                                                                                                                                                                                         CONC. PAD PLAN
                                                                                                                                                                                         ICE SHIELD PLAN
                                                                                                                                                                                                                                     0
                                                                                                                                                                                                                                     0
 LATITUDE            32.75040                                                                                                                               E01                       ELECTRICAL SITE PLAN                           0
                                                                                                                                                           E01.1                  ELECTRICAL DETAIL SITE PLAN                        0
 LONGITUDE:          -97.26890                                                                                                                             E02.0                   ELECTRICAL RISER DIAGRAM                          0
                                                                                                                                                           E02.1                ELECTRICAL AC PANEL SCHEDULES                        0
                                                                                                                                                           E03.0                  ELECTRICAL GROUNDING PLAN                          0
 AMSL:               627' AMSL                                                                                                                             E03.1                  EQUIPMENT GROUNDING PLAN                           0
                                                                                                                                                            E04                        ELECTRICAL DETAILS                            0
 JURISDICTION:       CITY OF FORT WORTH, TX                                                                                                                 E05                        ELECTRICAL DETAILS                            0
                                                                                                                                                            E06                    ELECTRICAL SPECIFICATIONS                         0
 TELEPHONE CO.:      TBD                                                                                                                                    M01
                                                                                                                                                            M02
                                                                                                                                                                                           MECHANICAL
                                                                                                                                                                                  MECHANICAL SPECIFICATIONS
                                                                                                                                                                                                                                     0
                                                                                                                                                                                                                                     0                                                    1/30/2018
                                                                                                                                                                                                                                                                                          1/30/201
                                                                                                                                                                                                                                                                                               20
                                                                                                                                                       SCOPE OF WORK:                                                                          No.                 Description                   Date
 POWER CO.:          TBD                                                                                                                                                                                                                        0          ISSUED FOR CONSTRUCTION              01/31/18
                                                                                                                                                        1.    CONTRACTOR TO HAVE ROOF INSPECTED BY CERTIFIED ROOFER, CONTRACTOR
                                                                                                                                                              RESPONSIBLE FOR ALL ROOF REPAIRS OR REPLACEMENT.

                     DRIVING DIRECTIONS                                                                                                                 2.
                                                                                                                                                        3.
                                                                                                                                                              INSTALL NEW CONCRETE PAD FOR OUTDOOR EQUIPMENT
                                                                                                                                                              INSTALL NEW ELECTRICAL SERVICE FROM EXISTING METER BASE
                                                                                                                                                        4.    INSTALL NEW LIGHTING FIXTURES, REMOVE EXISTING LIGHT FIXTURES

FROM DT DALLAS                                                                          SITE ADDRESS                                                    5.
                                                                                                                                                        6.
                                                                                                                                                              INSTALL (4) NEW HEAT EXCHANGERS
                                                                                                                                                              INSTALL NEW EQUIPMENT INDOOR CABINETS
                                                                                                                                                        7.    REPAIR EXISTING CHAIN LINK FENCE AND GATE AS NECESSARY. ALL VEGETATION TO BE


                                                                            3900 BARNETT ST.
DEPART UNTITLED ON GRIFFIN ST W (WEST)                                                                                                                        REMOVED FROM EXISTING FENCE AND ENSURE ALL FENCING IS SECURED
                                                                                                                                                        8.    REPAIR ALL GYP BOARD WALLS, TAPE & BED, PAINT COLOR TO BE DETERMINED
TURN RIGHT (NORTH-WEST) ONTO S AKARD ST                                                                                                                 9.    INSTALL NEW SPRAY INSULATION ON CEILING
TURN LEFT (SOUTH-WEST) ONTO CANTON ST                                                                                                                   10.   INSTALL NEW ICE BRIDGE FOR NEW CABLE
TAKE RAMP (LEFT) ONTO E RL THORNTON FWY
TAKE RAMP (LEFT) ONTO I-302
AT EXIT 18, TURN RIGHT ONTO RAMP
                                                                          FORT WORTH, TX 76103                                                          11.
                                                                                                                                                        12.
                                                                                                                                                        13.
                                                                                                                                                        14.
                                                                                                                                                              INSTALL NEW ANTENNA ON EXISTING TOWER
                                                                                                                                                              INSTALL NEW CANOPY OVER OUTDOOR EQUIPMENT
                                                                                                                                                              INSTALL HVAC SYSTEM
                                                                                                                                                              REPLACE EXISTING DOOR W/ NEW DOOR, FRAME & HARDWARE (KEYED LOCKS) PAINT TO
TURN LEFT (WEST) ONTO BRIDGE ST                                                                                                                               MATCH
                                                                                                                                                        15.   REMOVE ALL EXISTING DUCT WORK AND UNUSED CONDUIT ON CEILING AND WALLS.
TURN LEFT (SOUTH) ONTO OAKLAND BLVD                                                                                                                           (TOWER CONTROL EQUIPMENT TO REMAIN)
TURN RIGHT (WEST) ONTO BENMAR ST                                                                                                                        16.   SEAL ANY OPENINGS IN EQUIPMENT AREA WATER TIGHT
TURN RIGHT (NORTH) ONTO OAK CLIFF RD, THEN IMMEDIATELY TURN LEFT                                                                                        17.   STRIP FLOOR AND SEAL ALL CRACKS, EPOXY SEAL FLOOR, INSTALL NEW 4" RUBBER COVE
                                                                                                                                                              BASE COLOR TO BE SELECTED
(WEST) ONTO MENZER RD

                                                                               (TARRANT COUNTY)
ARRIVE NEAR FORT WORTH




                           VICINITY MAP                            SITE PHOTO                                     DESIGN TEAM                                                    BUILDING CODES
                                                                                              DESIGN ENGINEER:                                          ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
                                                                                              NAME:
                                                                                              ADDRESS:
                                                                                                                  CELERIS GROUP CONSULTING ENGINEERS
                                                                                                                  2000 E. LAMAR BLVD., SUITE 550
                                                                                                                                                        ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING
                                                                                                                                                        CODES AS ADOPTED BY THE LOCAL AUTHORITIES HAVING
                                                                                                                                                                                                                                                               ATC SITE #
                                                                                              CITY, STATE, ZIP:
                                                                                              CONTACT:
                                                                                                                  ARLINGTON, TX 76006
                                                                                                                  MARK STAPLETON
                                                                                                                                                        JURISDICTION.                                                                                            90555
                                                                                              PHONE:              817-446-1700                          1.       2015 INTERNATIONAL BUILDING CODE

                                                                                                                                                        2.       2017 NATIONAL ELECTRIC CODE
                                                                                                                                                                                                                                                            FT. WORTH
                                                                                                                                                        3.       ADOPTED CITY/COUNTY ORDINANCES
                                                                                                                                                                                                                                                           BROADCAST
                                                                                                                                                        4.       TIA/EIA-222


                                                                                                                                                                                                                                                                   TITLE PAGE
                                                                                                                                                                                               IF YOU DIG IN ANY STATE DIAL 811
                                                                                                                                                                                              FOR THE LOCAL "ONE CALL CENTER"
                                                                                                                                                                                                         IT'S THE LAW
                        AREA OF WORK                                                                                                                                                                                                          Project number                                17-10611
                                                                                                                                                                                                                                              Date                                          01/31/18
                                                                                                                                                        THE UTILITIES SHOWN HEREIN ARE FOR THE CONTRACTORS                                    Drawn by                                          KDR
                                                                         AREA OF WORK
                                                                                                                                                        CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON
                                                                                                                                                                                                                                              Checked by                                         ZG
                                                                                                                                                        THESE PLANS. THE ENGINEER/SURVEYOR ASSUMES NO RESPONSIBILITY

                                                                                                                                                                                                                                                                      T01
                                                                                                                                                        FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S
                                                                                                                                                        RESPONSIBILITY TO VERIFY ALL THE UTILITIES WITHIN THE LIMITS OF THE
                                                                                                                                                        WORK. ALL DAMAGE MADE TO THE EXISTING UTILITIES BY THE
                                                                                                                                                        CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE                                    Scale
                                                                                                                                                        CONTRACTOR.


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                           1/30/2018
                                           1/30/201
                                                20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 GENERAL NOTES



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                      N01
Scale


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                            1/30/2018
                                            1/30/201
                                                 20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 OVERALL SITE PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                      C01
Scale


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                          1/30/2018
                                          1/30/201
                                               20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 DETAIL SITE PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                     C02
Scale


                                               
                                               
    TOP OF MAST 1150'                Celeris Group Consulting Engineers
                                       2000 E. Lamar Blvd., Suite 550
                                             Arlington, TX 76006
                                            Phone: 817-446-1700
                                             Fax: 817-460-0677
                                            www.celerisgroup.com


                            Engineer:
                            Celeris Group Consulting Engineers
                            2000 E. Lamar Blvd., Suite 550
                            Arlington, TX 76006
                            Phone: 817-446-1700
                            Fax: 817-460-0677
                            Registration No: F-13992

                            Electrical Engineer:
                            Torres Engineering Services, Inc.
                            8237 Delafield Dr.
                            Ft. Worth, TX 76131
                            Phone: 682-556-0848
                            Registration No: F-10147



                        STAMP:




W    W




                                                                     1/30/2018
                                                                     1/30/201
                                                                          2
                         No.                 Description                   Date
                          0          ISSUED FOR CONSTRUCTION              01/31/18




                                         ATC SITE #
                                           90555
                                      FT. WORTH
                                     BROADCAST


                                      TOWER ELEVATION /
                                     ANTENNA ORIENTATION


                        Project number                                17-10611
                        Date                                          01/31/18
                        Drawn by                                          KDR
                        Checked by                                         ZG


                                             C03
                        Scale


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                            1/30/2018
                                            1/30/201
                                                 20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                       DETAILS



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                     C04
Scale


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                           1/30/2018
                                           1/30/201
                                                20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                       DETAILS



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                     C05
Scale


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                           1/30/2018
                                           1/30/201
                                                20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 FOUNDATION PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                        S01
Scale


                       
                       
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




                                           1/30/2018
                                           1/30/201
                                                20
 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 ICE SHIELD DETAILS



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                      S2.0
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


             ELECTRICAL SITE PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                        E01
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


         ELECTRICAL RISER DIAGRAM



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                       E02
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


        ELECTRICAL GROUNDING PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                   E03.0
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


        ELECTRICAL GROUNDING PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                    E03.1
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


        EQUIPMENT GROUNDING PLAN



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                   E03.2
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 ELECTRICAL DETAILS



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                       E04
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


                 ELECTRICAL DETAILS



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                       E05
Scale


                       celeris
CONSULTING ENGINEERS
                       group
             Celeris Group Consulting Engineers
               2000 E. Lamar Blvd., Suite 550
                     Arlington, TX 76006
                    Phone: 817-446-1700
                     Fax: 817-460-0677
                    www.celerisgroup.com


    Engineer:
    Celeris Group Consulting Engineers
    2000 E. Lamar Blvd., Suite 550
    Arlington, TX 76006
    Phone: 817-446-1700
    Fax: 817-460-0677
    Registration No: F-13992

    Electrical Engineer:
    Torres Engineering Services, Inc.
    8237 Delafield Dr.
    Ft. Worth, TX 76131
    Phone: 682-556-0848
    Registration No: F-10147



STAMP:




 1/31/18

 No.                 Description                   Date
  0          ISSUED FOR CONSTRUCTION              01/31/18




                 ATC SITE #
                   90555
              FT. WORTH
             BROADCAST


         ELECTRICAL SPECIFICATIONS



Project number                                17-10611
Date                                          01/31/18
Drawn by                                          KDR
Checked by                                         ZG


                       E06
Scale


                                                        NOTES BY SYMBOL " "                                                          GENERAL MECHANICAL NOTES
                                                                                                                                                                                                                                                celeris
                                                         1


                                                         2
                                                             PROVIDE TYPE "A" S/A GRILLE WITH MANUAL BALANCING DAMPER. BALANCE AIR
                                                             DEVICE TO 900 CFM

                                                             PROVIDE TYPE "B" R/A GRILLE ON SIDE OF RETURN AIR PLENUM BOX LOCATED
                                                             UNDERNEATH FAN COIL UNIT.
                                                                                                                                     A.



                                                                                                                                     B.
                                                                                                                                          PERFORM ALL WORK IN ACCORDANCE WITH MECHANICAL CODE, PLUMBING CODE,
                                                                                                                                          ENERGY CODE AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. PROVIDE
                                                                                                                                          ALL PERMITS, INSPECTIONS, LICENSES AND FEES.

                                                                                                                                          ALL DIMENSIONS SHOWN ON THE DRAWINGS FOR DUCTWORK ARE NET INSIDE CLEAR
                                                                                                                                                                                                                         CONSULTING ENGINEERS
                                                                                                                                                                                                                                                group
                                                                                                                                          DIMENSIONS. THE FIRST FIGURE OF THE DUCT SIZE INDICATES THE DIMENSION OF THE                Celeris Group Consulting Engineers
                                                             EXTEND 3/4" CONDENSATE DRAIN FROM FAN COIL UNIT AND TERMINATE TO                                                                                                           2000 E. Lamar Blvd., Suite 550
                                                         3                                                                                FACE SHOWN. VERIFY THAT THE DUCTWORK SPECIFIED WILL FIT IN THE SPACE                                Arlington, TX 76006
                                                             CONDENSATE FRENCH DRAIN PIT. DRAIN PIT SHALL BE 24"X24"X30" DEEP AND         AVAILABLE USING THE ARCHITECTURAL, STRUCTURAL, AND ELECTRICAL DRAWINGS AS                          Phone: 817-446-1700
                                                             CONSTRUCTED WITH PERFORATED CLAY CHIMNEY TILE AND CRUSHED STONE.             REFERENCE PRIOR TO FABRICATION AND INSTALLATION.                                                    Fax: 817-460-0677
                                                                                                                                                                                                                                             www.celerisgroup.com

                                                                                                                                     C.   MOUNT THERMOSTATS AT 4'-0" AFF T0 THE CENTER OF THE DEVICE. ALL
                                                                                                                                          INSTALLATIONS SHALL COMPLY WITH TEXAS ACCESSIBILITY STANDARDS.                     Engineer:
                                                                                                                                                                                                                             Celeris Group Consulting Engineers
                                                                                                                                                                                                                             2000 E. Lamar Blvd., Suite 550
                                                                                                                                     D.   BACK PANEL OF ALL CEILING MOUNTED AIR DEVICES SHALL BE INSULATED.                  Arlington, TX 76006
                                                                                                                                                                                                                             Phone: 817-446-1700
                                                                                                                                                                                                                             Fax: 817-460-0677
                                                                                                                                     E.   ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET             Registration No: F-13992
                                                                                                                                          STEEL IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION
                                                                                                                                          STANDARDS. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED             Electrical Engineer:
                                                                                                                                                                                                                             Torres Engineering Services, Inc.
                                                                                                                                          INDUSTRY PRACTICE FOR ACHIEVING AN AIR TIGHT SYSTEM. FURNISH ALL REQUIRED          8237 Delafield Dr.
                                                                                                                                          DAMPERS, TRANSITIONS, CONNECTIONS, AND ACCESSORIES NECESSARY FOR A                 Ft. Worth, TX 76131
                                                                                                                                                                                                                             Phone: 682-556-0848
                                                                                                                                          COMPLETE OPERATING SYSTEM. DUCT SYSTEMS SHALL BE CONSTRUCTED TO MEET               Registration No: F-10147
                                                                                                                                          2" W.G. SMACNA DUCT PRESSURE CLASS.

                                                                                                                                     F.   FOR INTERIOR SUPPLY AND RETURN AIR RECTANGULAR AIR DUCTS, PROVIDE 2" THICK     STAMP:
                                                                                                                                          DUCT WRAP WITH AN INSTALLED R-VALUE OF 6.3. THERMAL INSULATION TO COMPLY
                                                                                                                                          WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED RATING NO
                                                                                                                                          GREATER THAN 50. INSTALL INSULATION SYSTEMS PER MANUFACTURER'S
                                                                                                                                          INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS.

                                                                                                                                     G.   CONDENSATE PIPE SHALL BE TYPE L HARD COPPER INSULATED WITH 3/4" ARMAFLEX
                                                                                                                                          INSULATION OR EQUAL.

                                                                                                                                     H.   REFRIGERANT PIPING SHALL BE TYPE ACR COPPER WITH BRAZED JOINTS FOR R-410A
                                                                                                                                          REFRIGERANT. PIPING TO BE INSULATED WITH 1 1/2 INCH ARMAFLEX INSULATION.
                                                                                                                                          COORDINATE WITH FCU/CU MANUFACTURER FOR PIPE SIZING. ARMAFLEX TO BE
                                                                                                                                          PAINTED WITH LOCATED OUTDOORS.

                                                                                                                                     I.   EQUIPMENT TO BE INSTALLED WITH REQUIRED CLEARANCE AS REQUIRED PER
                                                                                                                                          EQUIPMENT INSTALLATION REQUIREMENTS AND ACTUAL FIELD CONDITIONS.

                                                                                                                                     J.   COORDINATE FIANL EQUIPMENT ELECTRICAL REQUIREMENTS WITH ELECTRICAL              No.                 Description                   Date
                                                                                                                                          CONTRACTOR PRIOR TO ORDERING OF EQUIPMENT TO INSURE PROPER BREAKER               0          ISSUED FOR CONSTRUCTION              01/31/18
                                                                                                                                          AND WIRE SIZE INSTALLED.




        1           1       1           1




            22/14               22/14

22/14                                           22/14
        2                   2               2
                    2

            FCU-1               FCU-2                                                                                                                                                                                                     ATC SITE #
                                                                                                                                                                                                                                            90555
                        3                                                                                                                                                                                                              FT. WORTH
                                                                                                                                                                                                                                      BROADCAST


                                                                                                                                                                                                                                            MECHANICAL
                                                                                                 CU-1                         CU-2

                                                                                                                                                                                                                         Project number                                17-10611
                                                                                                                                                                                                                         Date                                          01/31/18
                                                                                                                                                                                                                         Drawn by                                          KDR
                                                                                                                                                                                                                         Checked by                                         ZG


                                                                                                                                                                                                                                               M01
                                                                                                                                                                                                                         Scale


                                                                                                                                                                                                                                                                                                                            celeris
                                                                                                                                                                                                                                                                                                                            group
         ATMOSPHERE VENT TO RISE A
         MINIMUM 1" ABOVE THE TOP OF
                                                                 UNION                                  AIR DEVICE SCHEDULE
         DRAIN PAN
                                                                                                                  SERVES      NECK SIZE      FACE SIZE       MOUNTING                                                                                           MANUFACTURER
                                                                                                        MARK                                                                 DESCRIPTION                                                        MATERIAL                                NOTES
                                                                                                                                                                                                                                                                MODEL NUMBER
                                                                                                                                                                                                                                                                                                     CONSULTING ENGINEERS
                                                                                                          A       SUPPLY       24" X 12"      26" X 14"      SURFACE        LOUVER GRILLE                                                        STEEL          TITUS 300RS           1, 2, 3, 4
            PITCH DOWN                                                                                                                                                                                                                                                                                            Celeris Group Consulting Engineers
            TOWARD DRAIN                                                                                                                                                                                                                                                                                            2000 E. Lamar Blvd., Suite 550
            @ 1/8"/FT MIN                                                                                                                                                                                                                                                                                                 Arlington, TX 76006
                                                                                                          B       RETURN       18" X 18"      20" X 20"      SURFACE        EGGCRATE GRILLE                                                     ALUMINUM        TITUS 50F             1, 2, 3                            Phone: 817-446-1700
                                                             A                                                                                                                                                                                                                                                            Fax: 817-460-0677
                                                                             DRAIN PAN                                                                                                                                                                                                                                   www.celerisgroup.com
   CLEANOUT                                                                                              1. DIFFUSERS, REGISTERS, AND GRILLES SHALL BE TYPE FOR MOUNTING IN RESPECTIVE SURFACE TYPE. PROVIDE TITUS OR APPROVED EQUAL.
   PLUG (TYP)
                                                             B           DRAIN LINE SHALL BE AT LEAST    2. FINISH FOR DIFFUSERS, REGISTERS, AND GRILLES SHALL BE MANUFACTURER'S STANDARD WHITE, UNLESS OTHERWISE INDICATED.                                                                             Engineer:
                                                                         THE SAME SIZE AS THE NIPPLE                                                                                                                                                                                                     Celeris Group Consulting Engineers
                                                                                                         3. PROVIDE TRANSITION OR ADAPTER WHERE REQUIRED TO ADAPT DUCTWORK TO NECK SIZE.                                                                                                                 2000 E. Lamar Blvd., Suite 550
                                                                         ON THE DRAIN PAN                                                                                                                                                                                                                Arlington, TX 76006
                                                                                                         4. PROVIDE MANUAL BALANCING DAMPER FULL SIZE OF AIR DEVICE NECK ACCESSIBLE THROUGH DEVICE FACE.                                                                                                 Phone: 817-446-1700
                                                                                                                                                                                                                                                                                                         Fax: 817-460-0677
REFER TO FLOOR                                                                                                                                                                                                                                                                                           Registration No: F-13992
PLAN FOR CONT.                                                                                          FAN COIL UNIT SCHEDULE                                                                                                                                                                           Electrical Engineer:
                      UNIT TYPE           A         B
                                                                                                                                                                                                                                                                                                         Torres Engineering Services, Inc.
                                                                                                                                           EXTERNAL EVAPORATOR PERFORMANCE MOTOR     ELECTRICAL DATA                                                                                                     8237 Delafield Dr.
                      DRAW THRU     2" PLUS X        X                                                                         SUPPLY                                                                                                                                                                    Ft. Worth, TX 76131
                                                                                                                                             STATIC                                                                                              WEIGHT    MANUFACTURER
                                                                                                        MARK         TYPE      AIRFLOW                           ENTERING                                                                                                            NOTES               Phone: 682-556-0848
                                                                                                                                           PRESSURE T.C.    S.C.            HP   VOLTS PHASE HZ MCA                                      MOCP     (LB)     MODEL NUMBER                                  Registration No: F-10147
                                                                                                                                (ACFM)
                                                                                                                                            (IN WTR) (MBH) (MBH) D.B. W.B.
                      BLOW THRU     1" MINIMUM      2X
                                                                                                        FCU-1      VERTICAL      1,800        0.5         47.6   36.6     75.0   63.0         3/4       208    1        60        7.5      15      200     CARRIER FX4D061 (5-TON)   1, 2, 3, 4, 5   STAMP:
                      WHERE X = STATIC PRESSURE IN PAN                                                  FCU-2      VERTICAL      1,800        0.5         47.6   36.6     75.0   63.0         3/4       208    1        60        7.5      15      200     CARRIER FX4D061 (5-TON)   1, 2, 3, 4, 5


            TYPICAL CONDENSATE CONNECTION DETAIL                                                         1.   EXTERNAL STATIC PRESSURE EXCLUDES COIL AND FILTER LOSSES.
    1       SCALE: NO SCALE                                                                              2.   PROVIDE UNIT FOR VERTICAL CONFIGURATION WITH WATER FLOW SENSOR LOCATED IN OVERFLOW CONNECTION TO SHUT DOWN UNIT AND TXV.
                                                                                                         3.   FURNISH AND INSTALL TEMPERATURE CONTROLLER AND ALL CONTROL WIRING OF FAN COIL UNIT AND CONDENSING UNIT. CONTROLLER SHALL OPERATE ONLY ONE FCU AT A TIME.
                                                                                                         4.   PROVIDE CARRIER OR APPROVED EQUAL.
                                                                                                         5.   PROVIDE SMOKE DETECTOR IN R/A DUCT. MECHANICAL CONTRACTOR PROVIDE AND INSTALL, ELECTRICAL CONTRACTOR TO PROVIDE CIRCUITRY.
                                                                                                              INTERFACE WITH EXISTING FIRE ALARM SYSTEM AS REQUIRED TO SHUT-DOWN UNIT.
                   DUCTWORK SHALL BE GALVANIZED SHEET
                   METAL INSTALLED AND SEALED PER LATEST
                   SMACNA STANDARDS. SUPPLY DUCTWORK
                   SHALL BE WRAPPED WITH 2" DUCTWRAP
                   FOR A MINIMUM INSTALLED R-VALUE OF 6.0.
                                                                                                        AIR COOLED CONDENSER UNIT SCHEDULE
                                                                                                                                                CONDENSER UNIT DATA                      ELECTRICAL CHARACTERISTICS
                                                                                                                              NOMINAL                                                                                                                                                                 No.                 Description                   Date
                                        22/14 SUPPLY AIR DUCT PLENUM,                                                                                                                                                                            MANUFACTURER
                                                                                                         MARK      SERVES       SIZE                COOLING DATA                                                                                                       NOTES                           0          ISSUED FOR CONSTRUCTION              01/31/18
                                        SEE FLOOR PLAN FOR CONT.                                                                           REFRIG                       AMBIENT      VOLTS PHASE          HZ   MCA       MOCP           SEER     MODEL NUMBER
                                                                                                                               (TONS)
                                                                                                                                            TYPE          TMBH          TEMP. (°F)

                                       PROVIDE DUCT FLEXIBLE                                             CU-1       FCU-1        5         R410A          47.6             105          208         1     60       28        40         14.0     CARRIER 24ACC660      1, 2, 3
                                       CONNECTOR MINIMUM 6"
                                                                                                         CU-2       FCU-2        5         R410A          47.6             105          208         1     60       28        40         14.0     CARRIER 24ACC660      1, 2, 3


                                                                                                         1. SIZE, ROUTE, INSULATE AND PROVIDE REQUIRED APPURTENANCES FOR DX PIPING SYSTEMS IN ACCORDANCE WITH THE MANUFACTURERS
                                       FCU                                                                  RECOMMENDATIONS AND TO MINIMIZE ANY CAPACITY LOSSES. PROVIDE AND INSTALL ALL REQUIRED REFRIGERANT PIPING ACCESSORIES.
                                                                                                            PIPING SHALL BE TYPE ACR COPPER PIPE.
                                                                                                         2. UNIT SHALL BE SET ON 4" CONCRETE PAD.

                                                                                                         3. PROVIDE WITH LOW-AMBIENT CONTROLS AND HAIL GUARDS.

                                         PROVIDE 28" HIGH NONCOMBUSTIBLE RETURN AIR
           FLOOR                         PLENUM CONSTRUCTED OF ANGLE IRON AND SHEET
                                         METAL UNDERNEATH UNIT. PLENUM SHALL BE LINED
                                         WITH 1 1/2" DUCT LINER EQUAL TO JOHNS-MANSVILLE
                                         PERMACOTE LINACOUSTIC INSULATION ON ALL
                                         SURFACES INSIDE PLENUM. PROVIDE TYPE "B" R/A
                                         GRILLES ON TWO SIDES OF THE PLENUM, REFER TO
                                         FLOOR PLAN FOR LAYOUT.

             TYPICAL FAN COIL UNIT WITH DUCTWORK
     2       SCALE: NO SCALE
                                                                                                                                                                                                                                                                                                                      ATC SITE #
                                                                                                                                                                                                                                                                                                                        90555
                                                                                                                                                                                                                                                                                                                   FT. WORTH
                GENERAL FIRE PROTECTION NOTES                                                                                                                                                                                                                                                                     BROADCAST
     1     MODIFY EXISTING WET PIPE FIRE SPRINKLER SYSTEM, RELOCATE / ADD SPRINKLER HEADS
           AS REQUIRED TO ACCOMMODATE THE NEW CONSTRUCTION. PROVIDE COMPLETE AND
           OPERABLE WET PIPE FIRE SUPPRESSION SYSTEMS ENGINEERED AND DESIGNED
           CONFORMING TO NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS; NFPA 24, PRIVATE                                                                                                                                                                                                                                  MECHANICAL
           SERVICE MAINS AND THEIR APPURTENANCES; ALL APPLICABLE CITY, STATE AND NATIONAL                                                                                                                                                                                                                             SPECIFICATIONS
           CODES AND THE CODES AND ORDINANCES OF ALL OTHER AUTHORITIES HAVING
           JURISDICTION. THE SYSTEM SHALL MEET ALL APPLICABLE REQUIREMENTS OF THE CITY FIRE
           DEPARTMENT. CONTRACTOR SHALL PROVIDE FIRE SPRINKLER DRAWINGS TO LOCAL                                                                                                                                                                                                                     Project number                                17-10611
           OFFICIALS FOR APPROVAL. SYSTEM COMPONENTS SHALL BE EQUIVALENT TO EXISTING                                                                                                                                                                                                                 Date                                          01/31/18
           CONDITIONS IN TERMS OF MATERIALS.                                                                                                                                                                                                                                                         Drawn by                                          KDR
                                                                                                                                                                                                                                                                                                     Checked by                                         ZG
     2     CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY EXISTING CONDITIONS.
                                                                                                                                                                                                                                                                                                                          M02
                                                                                                                                                                                                                                                                                                     Scale