Explanation
Please explain in the area below why an STA is necessary:
to provide L3 engineering opportunity to develop system software and validate the hardware , in order to prepare the system for formal FCC emissions testing. We have done first scan in lab and emission is below FCC limits

Purpose of Operation
Please explain the purpose of operation:  Hardware validation testing, and system software development

Information
Callsign: WP9XJM
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 10/02/2019
Operation End Date: 03/31/2020

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
L3 Communications Security and Dete wideband 3D 3 Yes
L3 Communications Security and Dete wideband 3D 3 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): URESH PATEL
Title of Applicant (if any): Sr Compliance Engineer
Date: 2019-09-18 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
egg Harbor Township New Jersey North  39  26  38 West  74  33  31 0.01
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   Yes
(a) Width of beam in degrees at the half-power point:   80.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: INDOOR INSTALLATION ONLY
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20.00000000-23.60000000 GHz FX 48.900000 nW 74.900000 nW P 3G60G0F FMCW signals
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 24.00000000-31.30000000 GHz FX 48.900000 nW 74.900000 nW P 7G30G0F FMCW signals
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 31.80000000-40.00000000 GHz FX 48.900000 nW 74.900000 nW P 8G20G0F FMCW signals

City State Latitude Longitude Mobile Radius of Operation
Tewksbury Massachusetts North  42  38  17 West  71  14  13 0.20
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   Yes
(a) Width of beam in degrees at the half-power point:   80.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:   90.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: n/a
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20.00000000-23.60000000 GHz FX 48.900000 nW 74.900000 nW P 3G60F3X FMCW signals
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 24.00000000-31.30000000 GHz FX 48.900000 nW 74.900000 nW P 7G30F3X FMCW signals
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 31.80000000-40.00000000 GHz FX 48.900000 nW 74.900000 nW P 8G20F3X FMCW signals