Toggle navigation
FCC.report
IBFS
ELS
FCC ID
Contact
About
FCC.report
›
ELS
›
Gryphon Sensors, LLC
›
0335-EX-ST-2017
Gryphon Sensors, LLC
0335-EX-ST-2017
Status: Grant Expired Due to New License
WL9XAJ
2017-03-29
Documents and Communications:
[
refresh
]
Description
Category
Date
E-Mail generated [Mar 16 2017]
Correspondence
2017-03-16
Incoming generated [Mar 16 2017]
Correspondence
2017-03-16
Grant E-mail Notification generated [Mar 30 2017]
Correspondence
2017-03-30
Exhibit 1 Information on Experiment modified
Text Documents
2017-03-16
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY
Applicant Name
Name of Applicant:
Gryphon Sensors, LLC
Address
Attention:
TJ Vitale
Street Address:
7351 Round Pond Road
P.O. Box:
City:
N. Syracuse
State:
NY
Zip Code:
13212
Country:
E-Mail Address:
[email protected]
Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:
Last Name:
Vitale
First Name:
TJ
Title:
PM
Phone Number:
3155603968
Explanation
Please explain in the area below why an STA is necessary:
To support the USAFE project schedule in our state grant application we require transmit authority by May 5, 2017.
Purpose of Operation
Please explain the purpose of operation:
System test and UAS surveillance system demonstration in the state sponsored USAFE cooridor and related UTM UAS traffic management experiments.
Information
Callsign:
WL9XAJ
Class of Station:
MO
Nature of Service:
Experimental
Requested Period of Operation
Operation Start Date:
05/05/2017
Operation End Date:
11/05/2017
Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:
Manufacturer
Model Number
No. Of Units
Experimental
Gryphon Sensors, LLC
EXB Radar
5
Yes
Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form):
TJ Vitale
Title of Applicant (if any):
PM
Date:
2017-03-15 00:00:00.0
Station Location
City
State
Latitude
Longitude
Mobile
Radius of Operation
Lee
New York
North 43 16 41
West 75 34 15
Lee, NY: Transportable FX
20.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
12.00
(b) Elevation of ground at antenna site above mean sea level in meters:
156.00
(c) Distance to nearest aircraft landing area in kilometers:
4.10
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Trees, farm buildings
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.50000000-9.80000000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
City
State
Latitude
Longitude
Mobile
Radius of Operation
Clearwater
Florida
North 27 53 17
West 82 41 37
Clearwater, FL: Transportable FX
5.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
12.00
(b) Elevation of ground at antenna site above mean sea level in meters:
7.00
(c) Distance to nearest aircraft landing area in kilometers:
2.30
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Industrial park buildings
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.50000000-9.59600000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.60400000-9.61600000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.62400000-9.80000000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
City
State
Latitude
Longitude
Mobile
Radius of Operation
Lakeland
New York
North 43 5 1
West 76 13 18
Lakeland, NY: Transportable FX
15.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
12.00
(b) Elevation of ground at antenna site above mean sea level in meters:
130.00
(c) Distance to nearest aircraft landing area in kilometers:
4.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Trees, Ampitheater
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.50000000-9.80000000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
City
State
Latitude
Longitude
Mobile
Radius of Operation
Oak Ridge
Florida
North 28 27 27
West 81 25 48
Oak Ridge, FL: Transportable FX
25.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
12.00
(b) Elevation of ground at antenna site above mean sea level in meters:
26.00
(c) Distance to nearest aircraft landing area in kilometers:
5.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Industrial park buildings
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.50000000-9.59600000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.60400000-9.61600000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.62400000-9.80000000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
City
State
Latitude
Longitude
Mobile
Radius of Operation
Crows Landing
California
North 37 23 37
West 121 4 19
Crows Landing, CA: Transportable FX
10.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
12.00
(b) Elevation of ground at antenna site above mean sea level in meters:
35.00
(c) Distance to nearest aircraft landing area in kilometers:
3.80
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Farm buildings, trees
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.50000000-9.80000000 GHz
MO
512.000000 W 501.000000 kW
P
0.01000000 %
5M00Q3N
5M00Q3N
City
State
Latitude
Longitude
Mobile
Radius of Operation
Mountain View
California
North 37 24 9
West 122 2 26
Mountain View, CA:: Transportable FX
10.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
12.00
(b) Elevation of ground at antenna site above mean sea level in meters:
7.00
(c) Distance to nearest aircraft landing area in kilometers:
1.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
City buildings, industrial buildings
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
9.50000000-9.80000000 GHz
MO
512.000000 W 501.000000 kW
P
0.10000000 %
5M00Q3N
5M00Q3N
45016
© 2024 FCC.report