Experimental Licensing System

0270-EX-ST-2012

ITT EXCELIS, INC.

Filing overview

StatusDenied/Dismissed
Call signN/A
Filed2012-04-02
Status date2012-04-17
FCC sourceView the FCC filing record

Special Temporary Authority application - Address

Attention:
Royce Kincaid
City:
Herndon
E-Mail Address:
[email protected]
State:
VA
Street Address:
12975 Worldgate Drive
Zip Code:
20170

Special Temporary Authority application - Applicant Name

Name of Applicant:
ITT EXCELIS, INC.

Special Temporary Authority application - Best Contact

First Name:
Royce
Last Name:
Kincaid
Phone Number:
(703)439-7043
Title:
Director

Special Temporary Authority application - Certification

Applicant certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Date:
2012-04-02 00:00:00.0
Signature of Applicant (Authorized person filing form):
Royce Kincaid
Title of Applicant (if any):
Director

Special Temporary Authority application - Explanation

Please explain in the area below why an STA is necessary:
We are requesting this STA license to demonstrate wireless technology for the Department of Homeland Security from April 20th to October 20th, 2012.

Special Temporary Authority application - Information

Class of Station:
MO
Nature of Service:
Experimental

Special Temporary Authority application - Manufacturer

Equipment 1 Experimental
No
Equipment 1 Manufacturer
Motorola
Equipment 1 Model Number
PTP 45600
Equipment 1 No. Of Units
4

Special Temporary Authority application - Purpose of Operation

Please explain the purpose of operation:
This experimental is being used as a part of a technology demonstration for the Depratment of Homeland security for border protection along the U.S. - Mexican border.

Special Temporary Authority application - Requested Period of Operation

Operation End Date:
10/20/2012
Operation Start Date:
04/20/2012

Frequencies

ActionLower MHzUpper MHzClassOutput WERP WEmissionSignal
New4400.000000004600.00000000MO0.3160000.80000014M4D1D
New4400.000000004600.00000000MO0.3160000.80000014M4D1D
New4400.000000004600.00000000MO0.3160000.80000028M7D1D
New4400.000000004600.00000000MO0.3160000.80000028M7D1D
New4400.000000004600.00000000MO0.3160000.8000004M79D1D
New4400.000000004600.00000000MO0.3160000.8000004M79D1D
New4400.000000004600.00000000MO0.3160000.8000009M57D1D
New4400.000000004600.00000000MO0.3160000.8000009M57D1D

Sites

SiteLocationCoordinatesCountyRadius
Benson, ArizonaNorth 31 55 12 West 110 19 5580.50
Benson, ArizonaNorth 31 55 12 West 110 19 5580.50

Documents

DocumentTypeDateStatus
Dismissal Without Prejudice generated [Apr 17 2012]Correspondence2012-04-25Available
Additional InformationText Documents2012-04-02Available
NTIA CertificationText Documents2012-04-02Available
Expedited RequestText Documents2012-04-02Available
Vertical SketchText Documents2012-04-02Available

Sources and provenance

SourceSource recordRetrievedMatch
ELS0270-EX-ST-20122026-07-30 08:56:40Source Primary

Related FCC records

System or typeRecordRelationship
COMPANYITT EXCELIS, INC.Filed By
FILING0001-EX-CN-2017Concerns Station
FILING0001-EX-CN-2019Concerns Station
FILING0001-EX-PL-1998Concerns Station
FILING0002-EX-CN-2018Concerns Station
FILING0002-EX-CN-2019Concerns Station
FILING0002-EX-PL-1998Concerns Station
FILING0002-EX-PN-2019Concerns Station
FILING0002-EX-PN-2020Concerns Station
FILING0002-EX-ST-2019Concerns Station
FILING0003-EX-CN-2019Concerns Station
FILING0003-EX-PL-1998Concerns Station
FILING0003-EX-PN-2019Concerns Station
FILING0003-EX-ST-2002Concerns Station
FILING0004-EX-CN-2019Concerns Station
FILING0004-EX-PL-2003Concerns Station
FILING0004-EX-PL-2009Concerns Station
FILING0004-EX-PN-2019Concerns Station
FILING0004-EX-ST-1999Concerns Station
FILING0004-EX-ST-2005Concerns Station
FILING0004-EX-TN-2016Concerns Station
FILING0005-EX-CN-2019Concerns Station
FILING0005-EX-CN-2021Concerns Station
FILING0005-EX-MN-2017Concerns Station
FILING0005-EX-PN-2019Concerns Station
FILING0005-EX-ST-2003Concerns Station
FILING0005-EX-ST-2019Concerns Station
FILING0006-EX-CN-2017Concerns Station
FILING0006-EX-CN-2019Concerns Station
FILING0006-EX-MN-2017Concerns Station
FILING0006-EX-PL-2004Concerns Station
FILING0006-EX-PL-2005Concerns Station
FILING0006-EX-PL-2006Concerns Station
FILING0006-EX-PN-2019Concerns Station
FILING0007-EX-CN-2016Concerns Station
FILING0007-EX-CN-2019Concerns Station
FILING0007-EX-MN-2016Concerns Station
FILING0007-EX-PL-2009Concerns Station
FILING0007-EX-PL-2015Concerns Station
FILING0007-EX-PN-2018Concerns Station
FILING0007-EX-ST-2007Concerns Station
FILING0007-EX-ST-2010Concerns Station
FILING0007-EX-ST-2020Concerns Station
FILING0008-EX-CN-2019Concerns Station
FILING0008-EX-PL-2006Concerns Station
FILING0008-EX-PN-2018Concerns Station
FILING0008-EX-ST-2007Concerns Station
FILING0008-EX-ST-2008Concerns Station
FILING0008-EX-ST-2017Concerns Station
FILING0008-EX-TN-2017Concerns Station
FILING0008-EX-TN-2019Concerns Station
FILING0009-EX-PL-2006Concerns Station
FILING0009-EX-PL-2007Concerns Station
FILING0009-EX-PL-2011Concerns Station
FILING0009-EX-PN-2018Concerns Station
FILING0009-EX-PN-2019Concerns Station
FILING0009-EX-ST-1998Concerns Station
FILING0009-EX-ST-1999Concerns Station
FILING0009-EX-ST-2004Concerns Station
FILING0009-EX-ST-2019Concerns Station
FILING0010-EX-CN-2016Concerns Station
FILING0010-EX-CN-2018Concerns Station
FILING0010-EX-CN-2019Concerns Station
FILING0010-EX-ST-1998Concerns Station
FILING0010-EX-ST-1999Concerns Station
FILING0010-EX-ST-2000Concerns Station
FILING0010-EX-ST-2007Concerns Station
FILING0010-EX-TN-2016Concerns Station
FILING0011-EX-CN-2019Concerns Station
FILING0011-EX-ST-1999Concerns Station
FILING0011-EX-ST-2014Concerns Station
FILING0011-EX-TN-2017Concerns Station
FILING0012-EX-PL-2013Concerns Station
FILING0012-EX-PN-2017Concerns Station
FILING0012-EX-ST-1999Concerns Station
FILING0013-EX-CN-2019Concerns Station
FILING0013-EX-CN-2020Concerns Station
FILING0013-EX-PL-2002Concerns Station
FILING0013-EX-PN-2017Concerns Station
FILING0013-EX-ST-1999Concerns Station
FILING0013-EX-ST-2005Concerns Station
FILING0013-EX-ST-2011Concerns Station
FILING0013-EX-TN-2016Concerns Station
FILING0014-EX-PL-2003Concerns Station
FILING0014-EX-ST-2005Concerns Station
FILING0014-EX-TN-2016Concerns Station
FILING0015-EX-PL-2003Concerns Station
FILING0015-EX-PN-2019Concerns Station
FILING0015-EX-ST-2000Concerns Station
FILING0016-EX-CN-2017Concerns Station
FILING0016-EX-CN-2018Concerns Station
FILING0016-EX-CN-2019Concerns Station
FILING0016-EX-PL-2003Concerns Station
FILING0016-EX-PL-2009Concerns Station
FILING0016-EX-PL-2011Concerns Station
FILING0016-EX-PN-2018Concerns Station
FILING0016-EX-ST-2019Concerns Station
FILING0016-EX-TN-2016Concerns Station
FILING0016-EX-TN-2018Concerns Station
FILING0017-EX-CN-2016Concerns Station