Universal Licensing System

WQOG314

EnergyUnited Electric Membership Corporation

License details

ULS identifier3317878
Call signWQOG314
Radio serviceYG
StatusA
Grant date2021-09-11
Expiration2031-09-15
Frequency range456.05 - 457.975 MHz (13 frequencies)
Locations1
Representative locationStateville, IREDELL, NC
Coordinates35.7473333, -80.8664444
Source archivel_LMpriv.zip
Dataset refreshed2026-08-02 01:13:27

Licensee

NameEnergyUnited Electric Membership Corporation
Applicant typeC
FRN0006152631
LocationStatesville, NC
AddressStatesville, NC, 28687
Phone7048735241
Email[email protected]

Frequency assignments

LocationAntennaStation classAssigned MHzUpper MHzCarrier MHzOutput WERP WAltitude
11FB8C451.03750000100.000000170.000000
21FB8C451.05000000100.000000475.000000
51FB2C451.07500000100.000000320.000000
31FB8C451.0875000070.000000415.000000
11FB2C451.16250000100.000000170.000000
41FB8C451.20000000100.000000350.000000
11FB2C451.40000000100.000000170.000000
51FB8C451.55000000100.000000320.000000
41FB2C451.62500000100.000000350.000000
31FB2C451.7750000070.000000415.000000
31FB2C451.9750000070.000000415.000000
21FB2C452.00000000100.000000475.000000
51FB2C452.12500000100.000000320.000000
41FB2C452.43750000100.000000350.000000
21FB2C452.46250000100.000000475.000000
31FB2C452.6500000070.000000415.000000
21FB2C452.97500000100.000000475.000000
61MO8C456.0375000025.00000050.000000
111FX1C456.0375000025.00000025.000000
121FX1C456.0375000045.000000180.000000
71MO8C456.0500000025.00000050.000000
111FX1C456.0500000025.00000025.000000
124FX1C456.0500000045.000000210.000000
101MOC456.0750000025.00000050.000000
111FX1C456.0750000025.00000025.000000
123FX1C456.0750000045.000000210.000000
81MO8C456.0875000025.00000050.000000
111FX1C456.0875000025.00000025.000000
122FX1C456.0875000045.000000180.000000
61MOC456.1625000025.00000050.000000
111FX1C456.1625000025.00000025.000000
121FX1C456.1625000045.000000180.000000
91MO8C456.2000000025.00000050.000000
111FX1C456.2000000025.00000025.000000
125FX1C456.2000000045.000000500.000000
61MOC456.4000000025.00000050.000000
111FX1C456.4000000025.00000025.000000
121FX1C456.4000000045.000000180.000000
101MO8C456.5500000025.00000050.000000
111FX1C456.5500000025.00000025.000000
123FX1C456.5500000045.000000210.000000
91MOC456.6250000025.00000050.000000
111FX1C456.6250000025.00000025.000000
125FX1C456.6250000045.000000500.000000
81MOC456.7750000025.00000050.000000
111FX1C456.7750000025.00000025.000000
122FX1C456.7750000045.000000180.000000
81MOC456.9750000025.00000050.000000
111FX1C456.9750000025.00000025.000000
122FX1C456.9750000045.000000180.000000
71MOC457.0000000025.00000050.000000
111FX1C457.0000000025.00000025.000000
124FX1C457.0000000045.000000210.000000
101MOC457.1250000025.00000050.000000
111FX1C457.1250000025.00000025.000000
123FX1C457.1250000045.000000210.000000
91MOC457.4375000025.00000050.000000
111FX1C457.4375000025.00000025.000000
125FX1C457.4375000045.000000500.000000
71MOC457.4625000025.00000050.000000
111FX1C457.4625000025.00000025.000000
124FX1C457.4625000045.000000210.000000
81MOC457.6500000025.00000050.000000
111FX1C457.6500000025.00000025.000000
122FX1C457.6500000045.000000180.000000
71MOC457.9750000025.00000050.000000
111FX1C457.9750000025.00000025.000000
124FX1C457.9750000045.000000210.000000

Emission designators

LocationAntennaFrequency MHzUpper MHzEmission
11451.037500007K60FXE
11451.037500007K60FXD
11451.0375000011K2F3E
21451.0500000011K2F3E
21451.050000007K60FXE
21451.050000007K60FXD
51451.075000007K60FXD
51451.0750000011K2F3E
51451.075000007K60FXE
31451.087500007K60FXD
31451.0875000011K2F3E
31451.087500007K60FXE
11451.162500007K60FXD
11451.162500007K60FXE
11451.1625000011K2F3E
41451.200000007K60FXE
41451.200000007K60FXD
41451.2000000011K2F3E
11451.400000007K60FXD
11451.4000000011K2F3E
11451.400000007K60FXE
51451.550000007K60FXD
51451.550000007K60FXE
51451.5500000011K2F3E
41451.6250000011K2F3E
41451.625000007K60FXE
41451.625000007K60FXD
31451.775000007K60FXE
31451.7750000011K2F3E
31451.775000007K60FXD
31451.975000007K60FXD
31451.9750000011K2F3E
31451.975000007K60FXE
21452.0000000011K2F3E
21452.000000007K60FXE
21452.000000007K60FXD
51452.1250000011K2F3E
51452.125000007K60FXE
51452.125000007K60FXD
41452.437500007K60FXE
41452.437500007K60FXD
41452.4375000011K2F3E
21452.462500007K60FXE
21452.462500007K60FXD
21452.4625000011K2F3E
31452.650000007K60FXE
31452.6500000011K2F3E
31452.650000007K60FXD
21452.9750000011K2F3E
21452.975000007K60FXD
21452.975000007K60FXE
61456.037500007K60FXE
61456.037500007K60FXD
61456.0375000011K2F3E
111456.0375000011K2F3E
111456.037500007K60FXE
111456.037500007K60FXD
121456.037500007K60FXE
121456.037500007K60FXD
121456.0375000011K2F3E
71456.0500000011K2F3E
71456.050000007K60FXE
71456.050000007K60FXD
111456.050000007K60FXE
111456.050000007K60FXD
111456.0500000011K2F3E
124456.050000007K60FXD
124456.0500000011K2F3E
124456.050000007K60FXE
101456.0750000011K2F3E
101456.075000007K60FXD
101456.075000007K60FXE
111456.0750000011K2F3E
111456.075000007K60FXE
111456.075000007K60FXD
123456.075000007K60FXD
123456.075000007K60FXE
123456.0750000011K2F3E
81456.087500007K60FXD
81456.087500007K60FXE
81456.0875000011K2F3E
111456.087500007K60FXD
111456.087500007K60FXE
111456.0875000011K2F3E
122456.087500007K60FXD
122456.0875000011K2F3E
122456.087500007K60FXE
61456.162500007K60FXD
61456.162500007K60FXE
61456.1625000011K2F3E
111456.1625000011K2F3E
111456.162500007K60FXD
111456.162500007K60FXE
121456.1625000011K2F3E
121456.162500007K60FXD
121456.162500007K60FXE
91456.200000007K60FXE
91456.2000000011K2F3E
91456.200000007K60FXD
111456.200000007K60FXD
111456.200000007K60FXE
111456.2000000011K2F3E
125456.2000000011K2F3E
125456.200000007K60FXD
125456.200000007K60FXE
61456.400000007K60FXE
61456.4000000011K2F3E
61456.400000007K60FXD
111456.4000000011K2F3E
111456.400000007K60FXD
111456.400000007K60FXE
121456.400000007K60FXE
121456.400000007K60FXD
121456.4000000011K2F3E
101456.5500000011K2F3E
101456.550000007K60FXE
101456.550000007K60FXD
111456.5500000011K2F3E
111456.550000007K60FXE
111456.550000007K60FXD
123456.550000007K60FXE
123456.550000007K60FXD
123456.5500000011K2F3E
91456.625000007K60FXE
91456.625000007K60FXD
91456.6250000011K2F3E
111456.625000007K60FXE
111456.625000007K60FXD
111456.6250000011K2F3E
125456.625000007K60FXD
125456.6250000011K2F3E
125456.625000007K60FXE
81456.775000007K60FXD
81456.7750000011K2F3E
81456.775000007K60FXE
111456.7750000011K2F3E
111456.775000007K60FXE
111456.775000007K60FXD
122456.775000007K60FXE
122456.775000007K60FXD
122456.7750000011K2F3E
81456.975000007K60FXD
81456.9750000011K2F3E
81456.975000007K60FXE
111456.975000007K60FXE
111456.975000007K60FXD
111456.9750000011K2F3E
122456.975000007K60FXE
122456.9750000011K2F3E
122456.975000007K60FXD
71457.0000000011K2F3E
71457.000000007K60FXD
71457.000000007K60FXE
111457.0000000011K2F3E
111457.000000007K60FXE
111457.000000007K60FXD
124457.000000007K60FXE
124457.0000000011K2F3E
124457.000000007K60FXD
101457.1250000011K2F3E
101457.125000007K60FXE
101457.125000007K60FXD
111457.1250000011K2F3E
111457.125000007K60FXD
111457.125000007K60FXE
123457.125000007K60FXD
123457.1250000011K2F3E
123457.125000007K60FXE
91457.437500007K60FXD
91457.4375000011K2F3E
91457.437500007K60FXE
111457.4375000011K2F3E
111457.437500007K60FXE
111457.437500007K60FXD
125457.4375000011K2F3E
125457.437500007K60FXE
125457.437500007K60FXD
71457.462500007K60FXD
71457.462500007K60FXE
71457.4625000011K2F3E
111457.462500007K60FXE
111457.462500007K60FXD
111457.4625000011K2F3E
124457.4625000011K2F3E
124457.462500007K60FXE
124457.462500007K60FXD
81457.650000007K60FXD
81457.650000007K60FXE
81457.6500000011K2F3E
111457.650000007K60FXE
111457.6500000011K2F3E
111457.650000007K60FXD
122457.6500000011K2F3E
122457.650000007K60FXD
122457.650000007K60FXE
71457.975000007K60FXD
71457.975000007K60FXE
71457.9750000011K2F3E
111457.975000007K60FXD
111457.975000007K60FXE
111457.9750000011K2F3E
124457.9750000011K2F3E
124457.975000007K60FXE
124457.975000007K60FXD

Licensed locations

LocationTypeAddressCoordinatesGround elevationStructureHeightNEPA
13532 Tower Road, Denver, CATAWBA, NC35.56766667, -81.08972222463.400 mTower54.300 m structure / 54.300 m overall
2Adkins Rd .8 km S of I40, Kernserville, GUILFORD, NC36.08566667, -80.00919444287.100 mTower74.700 m structure / 75.300 m overall
3Pores Knob, Moravian Falls, WILKES, NC36.04638889, -81.15694444815.000 mTower30.000 m structure / 30.000 m overall
4Rhodes Rd, Madison, STOKES, NC36.44361111, -80.09416667322.000 mTower52.000 m structure / 52.000 m overall
5.4 km W of Three Hat Mtn, Lexington, DAVIDSON, NC35.75222222, -80.13777778342.900 mTower61.000 m structure / 67.000 m overall
6
7
8
9
10
11NC
12567 Mocksville Hwy, Stateville, IREDELL, NC35.74733333, -80.86644444301.800 mTOWER60.400 m structure / 60.400 m overallN

Antennas

LocationAntennaTypeMake / modelHeightPolarizationGain dBAzimuthRadiation centerMaximum EIRP W
11T46.800 m238.000
12T67.800 m94.000
13T29.500 m428.000
14T50.500 m104.000
15T59.500 m181.000
16T
17T
18T
19T
110T
111T
112T30.500 mV72.000
212T30.500 mV72.000
312T30.500 mV72.000
412T60.400 mV102.000
512T60.400 mV102.000

Control points

NumberAddressCountyPhone
1567 Mocksville Highway, Statesville, NCIREDELL7048735241

License history

DateFile or call signAction
2021-09-11WQOG314LIREN
2021-06-21WQOG314LETRES
2012-02-28WQOG314LIMOD
2011-09-15WQOG314LIISS

Sources and provenance

SourceSource recordRetrievedMatch
ULS33178782026-08-02 01:13:27Official Bulk Record
Selected field provenance
FieldDisplayed valueSourceObserved
Call SignWQOG314ULS 33178782026-08-02 01:13:27
StatusAULS 33178782026-08-02 01:13:27
ServiceYGULS 33178782026-08-02 01:13:27
Grant Date2021-09-11ULS 33178782026-08-02 01:13:27
Expiration Date2031-09-15ULS 33178782026-08-02 01:13:27