Universal Licensing System
WPDW375
VIRGINIA INTERNATIONAL TERMINALS INC
License details
| ULS identifier | 1923031 |
|---|
| Call sign | WPDW375 |
|---|
| Radio service | YB |
|---|
| Status | A |
|---|
| Grant date | 2025-04-12 |
|---|
| Expiration | 2035-06-28 |
|---|
| Frequency range | 857.8375 - 860.8625 MHz (8 frequencies) |
|---|
| Locations | 3 |
|---|
| Representative location | NORFOLK, VA |
|---|
| Coordinates | 36.9156944, -76.3032778 |
|---|
| Source archive | l_LMpriv.zip |
|---|
| Dataset refreshed | 2026-08-02 01:14:49 |
|---|
Frequency assignments
| Location | Antenna | Station class | Assigned MHz | Upper MHz | Carrier MHz | Output W | ERP W | Altitude |
|---|
| 2 | 1 | FX1 | 809.76250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 809.76250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 809.78750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 809.78750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 810.01250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 810.01250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 810.08750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 810.08750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 810.28750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 810.28750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 810.51250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 810.51250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 810.81250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 810.81250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 811.83750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 811.83750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 811.86250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 811.86250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 812.83750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 812.83750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 813.83750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 813.83750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 813.91250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 813.91250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 814.83750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 814.83750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 814.91250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 814.91250000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 815.78750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 815.78750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 815.83750000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 815.83750000 | | | 35.000000 | 35.000000 | |
| 2 | 1 | FX1 | 815.86250000 | | | 35.000000 | 50.000000 | |
| 3 | 1 | MO | 815.86250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 854.76250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 854.76250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 854.78750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 854.78750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 855.01250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 855.01250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 855.08750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 855.08750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 855.28750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 855.28750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 855.51250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 855.51250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 855.81250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 855.81250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 856.83750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 856.83750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 856.86250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 856.86250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 857.83750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 857.83750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 858.83750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 858.83750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 858.91250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 858.91250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 859.83750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 859.83750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 859.91250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 859.91250000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 860.78750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 860.78750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 860.83750000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 860.83750000 | | | 35.000000 | 35.000000 | |
| 1 | 1 | FB2C | 860.86250000 | | | 110.000000 | 300.000000 | |
| 3 | 1 | MO | 860.86250000 | | | 35.000000 | 35.000000 | |
Emission designators
| Location | Antenna | Frequency MHz | Upper MHz | Emission |
|---|
| 2 | 1 | 809.76250000 | | 20K0F3E |
| 2 | 1 | 809.76250000 | | 7K60FXE |
| 2 | 1 | 809.76250000 | | 7K60FXD |
| 3 | 1 | 809.76250000 | | 7K60FXE |
| 3 | 1 | 809.76250000 | | 7K60FXD |
| 3 | 1 | 809.76250000 | | 20K0F3E |
| 2 | 1 | 809.78750000 | | 7K60FXE |
| 2 | 1 | 809.78750000 | | 20K0F3E |
| 2 | 1 | 809.78750000 | | 7K60FXD |
| 3 | 1 | 809.78750000 | | 20K0F3E |
| 3 | 1 | 809.78750000 | | 7K60FXE |
| 3 | 1 | 809.78750000 | | 7K60FXD |
| 2 | 1 | 810.01250000 | | 7K60FXE |
| 2 | 1 | 810.01250000 | | 20K0F3E |
| 2 | 1 | 810.01250000 | | 7K60FXD |
| 3 | 1 | 810.01250000 | | 7K60FXE |
| 3 | 1 | 810.01250000 | | 7K60FXD |
| 3 | 1 | 810.01250000 | | 20K0F3E |
| 2 | 1 | 810.08750000 | | 7K60FXE |
| 2 | 1 | 810.08750000 | | 20K0F3E |
| 2 | 1 | 810.08750000 | | 7K60FXD |
| 3 | 1 | 810.08750000 | | 7K60FXE |
| 3 | 1 | 810.08750000 | | 7K60FXD |
| 3 | 1 | 810.08750000 | | 20K0F3E |
| 2 | 1 | 810.28750000 | | 7K60FXD |
| 2 | 1 | 810.28750000 | | 20K0F3E |
| 2 | 1 | 810.28750000 | | 7K60FXE |
| 3 | 1 | 810.28750000 | | 20K0F3E |
| 3 | 1 | 810.28750000 | | 7K60FXD |
| 3 | 1 | 810.28750000 | | 7K60FXE |
| 2 | 1 | 810.51250000 | | 7K60FXE |
| 2 | 1 | 810.51250000 | | 20K0F3E |
| 2 | 1 | 810.51250000 | | 7K60FXD |
| 3 | 1 | 810.51250000 | | 20K0F3E |
| 3 | 1 | 810.51250000 | | 7K60FXD |
| 3 | 1 | 810.51250000 | | 7K60FXE |
| 2 | 1 | 810.81250000 | | 7K60FXD |
| 2 | 1 | 810.81250000 | | 20K0F3E |
| 2 | 1 | 810.81250000 | | 7K60FXE |
| 3 | 1 | 810.81250000 | | 7K60FXE |
| 3 | 1 | 810.81250000 | | 7K60FXD |
| 3 | 1 | 810.81250000 | | 20K0F3E |
| 2 | 1 | 811.83750000 | | 7K60FXE |
| 2 | 1 | 811.83750000 | | 20K0F3E |
| 2 | 1 | 811.83750000 | | 7K60FXD |
| 3 | 1 | 811.83750000 | | 20K0F3E |
| 3 | 1 | 811.83750000 | | 7K60FXE |
| 3 | 1 | 811.83750000 | | 7K60FXD |
| 2 | 1 | 811.86250000 | | 7K60FXE |
| 2 | 1 | 811.86250000 | | 7K60FXD |
| 2 | 1 | 811.86250000 | | 20K0F3E |
| 3 | 1 | 811.86250000 | | 20K0F3E |
| 3 | 1 | 811.86250000 | | 7K60FXE |
| 3 | 1 | 811.86250000 | | 7K60FXD |
| 2 | 1 | 812.83750000 | | 7K60FXE |
| 2 | 1 | 812.83750000 | | 7K60FXD |
| 2 | 1 | 812.83750000 | | 20K0F3E |
| 3 | 1 | 812.83750000 | | 7K60FXE |
| 3 | 1 | 812.83750000 | | 7K60FXD |
| 3 | 1 | 812.83750000 | | 20K0F3E |
| 2 | 1 | 813.83750000 | | 7K60FXE |
| 2 | 1 | 813.83750000 | | 7K60FXD |
| 2 | 1 | 813.83750000 | | 20K0F3E |
| 3 | 1 | 813.83750000 | | 7K60FXD |
| 3 | 1 | 813.83750000 | | 7K60FXE |
| 3 | 1 | 813.83750000 | | 20K0F3E |
| 2 | 1 | 813.91250000 | | 7K60FXE |
| 2 | 1 | 813.91250000 | | 20K0F3E |
| 2 | 1 | 813.91250000 | | 7K60FXD |
| 3 | 1 | 813.91250000 | | 20K0F3E |
| 3 | 1 | 813.91250000 | | 7K60FXE |
| 3 | 1 | 813.91250000 | | 7K60FXD |
| 2 | 1 | 814.83750000 | | 20K0F3E |
| 2 | 1 | 814.83750000 | | 7K60FXE |
| 2 | 1 | 814.83750000 | | 7K60FXD |
| 3 | 1 | 814.83750000 | | 7K60FXE |
| 3 | 1 | 814.83750000 | | 20K0F3E |
| 3 | 1 | 814.83750000 | | 7K60FXD |
| 2 | 1 | 814.91250000 | | 7K60FXE |
| 2 | 1 | 814.91250000 | | 20K0F3E |
| 2 | 1 | 814.91250000 | | 7K60FXD |
| 3 | 1 | 814.91250000 | | 7K60FXD |
| 3 | 1 | 814.91250000 | | 7K60FXE |
| 3 | 1 | 814.91250000 | | 20K0F3E |
| 2 | 1 | 815.78750000 | | 20K0F3E |
| 2 | 1 | 815.78750000 | | 7K60FXE |
| 2 | 1 | 815.78750000 | | 7K60FXD |
| 3 | 1 | 815.78750000 | | 20K0F3E |
| 3 | 1 | 815.78750000 | | 7K60FXD |
| 3 | 1 | 815.78750000 | | 7K60FXE |
| 2 | 1 | 815.83750000 | | 7K60FXE |
| 2 | 1 | 815.83750000 | | 20K0F3E |
| 2 | 1 | 815.83750000 | | 7K60FXD |
| 3 | 1 | 815.83750000 | | 7K60FXD |
| 3 | 1 | 815.83750000 | | 7K60FXE |
| 3 | 1 | 815.83750000 | | 20K0F3E |
| 2 | 1 | 815.86250000 | | 7K60FXD |
| 2 | 1 | 815.86250000 | | 20K0F3E |
| 2 | 1 | 815.86250000 | | 7K60FXE |
| 3 | 1 | 815.86250000 | | 7K60FXE |
| 3 | 1 | 815.86250000 | | 7K60FXD |
| 3 | 1 | 815.86250000 | | 20K0F3E |
| 1 | 1 | 854.76250000 | | 20K0F3E |
| 1 | 1 | 854.76250000 | | 7K60FXD |
| 1 | 1 | 854.76250000 | | 7K60FXE |
| 3 | 1 | 854.76250000 | | 7K60FXD |
| 3 | 1 | 854.76250000 | | 20K0F3E |
| 3 | 1 | 854.76250000 | | 7K60FXE |
| 1 | 1 | 854.78750000 | | 20K0F3E |
| 1 | 1 | 854.78750000 | | 7K60FXE |
| 1 | 1 | 854.78750000 | | 7K60FXD |
| 3 | 1 | 854.78750000 | | 7K60FXE |
| 3 | 1 | 854.78750000 | | 20K0F3E |
| 3 | 1 | 854.78750000 | | 7K60FXD |
| 1 | 1 | 855.01250000 | | 7K60FXE |
| 1 | 1 | 855.01250000 | | 7K60FXD |
| 1 | 1 | 855.01250000 | | 20K0F3E |
| 3 | 1 | 855.01250000 | | 20K0F3E |
| 3 | 1 | 855.01250000 | | 7K60FXD |
| 3 | 1 | 855.01250000 | | 7K60FXE |
| 1 | 1 | 855.08750000 | | 7K60FXE |
| 1 | 1 | 855.08750000 | | 7K60FXD |
| 1 | 1 | 855.08750000 | | 20K0F3E |
| 3 | 1 | 855.08750000 | | 7K60FXE |
| 3 | 1 | 855.08750000 | | 20K0F3E |
| 3 | 1 | 855.08750000 | | 7K60FXD |
| 1 | 1 | 855.28750000 | | 7K60FXE |
| 1 | 1 | 855.28750000 | | 7K60FXD |
| 1 | 1 | 855.28750000 | | 20K0F3E |
| 3 | 1 | 855.28750000 | | 20K0F3E |
| 3 | 1 | 855.28750000 | | 7K60FXE |
| 3 | 1 | 855.28750000 | | 7K60FXD |
| 1 | 1 | 855.51250000 | | 7K60FXE |
| 1 | 1 | 855.51250000 | | 7K60FXD |
| 1 | 1 | 855.51250000 | | 20K0F3E |
| 3 | 1 | 855.51250000 | | 7K60FXE |
| 3 | 1 | 855.51250000 | | 7K60FXD |
| 3 | 1 | 855.51250000 | | 20K0F3E |
| 1 | 1 | 855.81250000 | | 7K60FXD |
| 1 | 1 | 855.81250000 | | 20K0F3E |
| 1 | 1 | 855.81250000 | | 7K60FXE |
| 3 | 1 | 855.81250000 | | 7K60FXD |
| 3 | 1 | 855.81250000 | | 20K0F3E |
| 3 | 1 | 855.81250000 | | 7K60FXE |
| 1 | 1 | 856.83750000 | | 7K60FXE |
| 1 | 1 | 856.83750000 | | 20K0F3E |
| 1 | 1 | 856.83750000 | | 7K60FXD |
| 3 | 1 | 856.83750000 | | 20K0F3E |
| 3 | 1 | 856.83750000 | | 7K60FXE |
| 3 | 1 | 856.83750000 | | 7K60FXD |
| 1 | 1 | 856.86250000 | | 20K0F3E |
| 1 | 1 | 856.86250000 | | 7K60FXD |
| 1 | 1 | 856.86250000 | | 7K60FXE |
| 3 | 1 | 856.86250000 | | 7K60FXE |
| 3 | 1 | 856.86250000 | | 20K0F3E |
| 3 | 1 | 856.86250000 | | 7K60FXD |
| 1 | 1 | 857.83750000 | | 7K60FXD |
| 1 | 1 | 857.83750000 | | 7K60FXE |
| 1 | 1 | 857.83750000 | | 20K0F3E |
| 3 | 1 | 857.83750000 | | 7K60FXE |
| 3 | 1 | 857.83750000 | | 20K0F3E |
| 3 | 1 | 857.83750000 | | 7K60FXD |
| 1 | 1 | 858.83750000 | | 20K0F3E |
| 1 | 1 | 858.83750000 | | 7K60FXE |
| 1 | 1 | 858.83750000 | | 7K60FXD |
| 3 | 1 | 858.83750000 | | 7K60FXE |
| 3 | 1 | 858.83750000 | | 20K0F3E |
| 3 | 1 | 858.83750000 | | 7K60FXD |
| 1 | 1 | 858.91250000 | | 7K60FXE |
| 1 | 1 | 858.91250000 | | 7K60FXD |
| 1 | 1 | 858.91250000 | | 20K0F3E |
| 3 | 1 | 858.91250000 | | 7K60FXD |
| 3 | 1 | 858.91250000 | | 20K0F3E |
| 3 | 1 | 858.91250000 | | 7K60FXE |
| 1 | 1 | 859.83750000 | | 20K0F3E |
| 1 | 1 | 859.83750000 | | 7K60FXE |
| 1 | 1 | 859.83750000 | | 7K60FXD |
| 3 | 1 | 859.83750000 | | 7K60FXD |
| 3 | 1 | 859.83750000 | | 7K60FXE |
| 3 | 1 | 859.83750000 | | 20K0F3E |
| 1 | 1 | 859.91250000 | | 7K60FXD |
| 1 | 1 | 859.91250000 | | 20K0F3E |
| 1 | 1 | 859.91250000 | | 7K60FXE |
| 3 | 1 | 859.91250000 | | 7K60FXE |
| 3 | 1 | 859.91250000 | | 20K0F3E |
| 3 | 1 | 859.91250000 | | 7K60FXD |
| 1 | 1 | 860.78750000 | | 7K60FXD |
| 1 | 1 | 860.78750000 | | 7K60FXE |
| 1 | 1 | 860.78750000 | | 20K0F3E |
| 3 | 1 | 860.78750000 | | 20K0F3E |
| 3 | 1 | 860.78750000 | | 7K60FXE |
| 3 | 1 | 860.78750000 | | 7K60FXD |
| 1 | 1 | 860.83750000 | | 20K0F3E |
| 1 | 1 | 860.83750000 | | 7K60FXD |
| 1 | 1 | 860.83750000 | | 7K60FXE |
| 3 | 1 | 860.83750000 | | 7K60FXE |
| 3 | 1 | 860.83750000 | | 7K60FXD |
| 3 | 1 | 860.83750000 | | 20K0F3E |
| 1 | 1 | 860.86250000 | | 7K60FXD |
| 1 | 1 | 860.86250000 | | 20K0F3E |
| 1 | 1 | 860.86250000 | | 7K60FXE |
| 3 | 1 | 860.86250000 | | 7K60FXD |
| 3 | 1 | 860.86250000 | | 20K0F3E |
| 3 | 1 | 860.86250000 | | 7K60FXE |
Licensed locations
| Location | Type | Address | Coordinates | Ground elevation | Structure | Height | NEPA |
|---|
| 1 | T | VIRGINIA INTL TERM OPERATIONS TWR, NORFOLK, VA | 36.91569444, -76.30327778 | 4.000 m | B | 43.000 m structure / 43.000 m overall | N |
| 2 | T | VA | | | | | |
| 3 | T | | | | | | |
Antennas
| Location | Antenna | Type | Make / model | Height | Polarization | Gain dB | Azimuth | Radiation center | Maximum EIRP W |
|---|
| 1 | 1 | T | | 49.000 m | | | | 44.000 | |
| 1 | 2 | T | | | | | | | |
| 1 | 3 | T | | | | | | | |
Control points
| Number | Address | County | Phone |
|---|
| 1 | 7737 HAMPTON BLVD, NORFOLK, VA | NORFOLK CITY | 8044407169 |
License history
| Date | File or call sign | Action |
|---|
| 2025-04-12 | WPDW375 | LIREN |
| 2025-04-07 | WPDW375 | LETRES |
| 2015-06-04 | WPDW375 | LIREN |
| 2015-04-06 | WPDW375 | LETRES |
| 2015-01-13 | WPDW375 | LIMOD |
| 2005-06-09 | WPDW375 | LIREN |
| 2005-06-08 | WPDW375 | ESUAPR |
| 2005-04-04 | WPDW375 | LETRES |
| 2000-11-24 | WPDW375 | LICCNV |
| 2000-04-19 | WPDW375 | LIREN |
| 2000-04-19 | WPDW375 | AUTHPR |
| 2000-03-27 | WPDW375 | LETRES |
Sources and provenance
| Source | Source record | Retrieved | Match |
|---|
| ULS | 1923031 | 2026-08-02 01:14:49 | Official Bulk Record |
Selected field provenance
| Field | Displayed value | Source | Observed |
|---|
| Call Sign | WPDW375 | ULS 1923031 | 2026-08-02 01:14:49 |
| Status | A | ULS 1923031 | 2026-08-02 01:14:49 |
| Service | YB | ULS 1923031 | 2026-08-02 01:14:49 |
| Grant Date | 2025-04-12 | ULS 1923031 | 2026-08-02 01:14:49 |
| Expiration Date | 2035-06-28 | ULS 1923031 | 2026-08-02 01:14:49 |