Attachment Exhibit B

This document pretains to SES-MOD-20160628-00621 for Modification on a Satellite Earth Station filing.

IBFS_SESMOD2016062800621_1141003

                                            Exhibit B
                            Viacom International Inc.
                                     Call Sign E8776
                              Modification of License
                                           June 2016

Radiation Hazard Analysis


                                            DOCUMENT HISTORY
REV   DESCRIPTION                                                                    DATE          APPROVED
1     RESULTS SUBMITTAL                                                              5/10/16       Gerard Johnston




                      ORIGINATOR               DATE
                      Gerard Johnston          5/9/16
                      ENGINEER                 DATE                                     45 OSER AVENUE
                      Ken Wieland              5/9/16                               HAUPPAUGE, NY 11788 USA
                      APPROVED                 DATE                TITLE
                      Ken Wieland              5/9/16                Test Procedure/Results – Viacom Radiation
                            DO NOT SCALE DRAWING                              Analysis – ANT 4, 5, 6, 11
                            WORK FROM DIMENSIONS
                                                                   CAGE CODE                   DWG NO.               REV
                      THIS DOCUMENT, OR PARTS THEREOF MAY NOT BE
                        USED OR REPRODUCED IN ANY FORM, BY ANY
                      METHOD, WITHOUT THE WRITTEN AUTHORIZATION
                                                                    02MQ7                11081-04104                     1
                              OF GLOBECOMM SYSTEMS, INC.
                                                                           SCALE:       NONE             SHEET: 1 OF 7


                                              TABLE OF CONTENTS



SECTION                                            DESCRIPTION                                                     PAGE




Table of Contents
1.      GENERAL .............................................................................................................. 3
1.1 SCOPE ..................................................................................................................... 3
1.2 PURPOSE ................................................................................................................. 3
1.3 CONDITIONS OF TEST ................................................................................................ 3
  1.3.1 General ............................................................................................................ 3
  1.3.2 Test Methods ................................................................................................... 3
  1.3.3 Environmental .................................................................................................. 4
  1.3.4 Equipment Calibration ...................................................................................... 4
2.      APPLICABLE DOCUMENTS................................................................................. 5
2.1 RADIATION HAZARD TEST .......................................................................................... 6
  2.1.1 Purpose ............................................................................................................ 6
  2.1.2 Specification ..................................................................................................... 6
  2.1.3 Test Equipment ................................................................................................ 6
  2.1.4 Procedure ......................................................................................................... 6




                                                          CAGE CODE               DRAWING NO.                          REV.
                                                               02MQ7                        11081-04104                             1
                                                             SIZE         A            SCALE      NONE         SHEET 2 OF 7


H:\PROPOSAL\12200\12226_Viac_Viacom MTV Hauppauge\procedures\Report 2a - Ant4 5 6 11 RF Hazard Report.doc


1.      GENERAL

1.1     Scope

        This document establishes the test procedures and documents the results for the
        onsite RF radiation hazard testing provided by Globecomm Systems Inc.
        (Globecomm).


1.2     Purpose
        This document is submitted as required in accordance with the requirements of
        the contract, and testing was implemented to record measured data by the
        Globecomm engineering team.

1.3     Conditions of Test


        1.3.1 General
        The tests described herein are designed for testing of ground segment systems
        on-site at Viacom earth station facility. Antenna systems to be tested for RF
        radiation should be RF transmitting at nominal levels consistent with the FCC
        license assigned to such terminal.

        1.3.2 Test Methods
        The test methods prescribed in this procedure shall be mandatory in the
        conductance of the test, except for those cases in which special conditions
        existing at the time of test dictate certain modifications or changes. In such
        cases, full documentation of the conditions and the nature of the changes shall
        be provided and recorded on the test data sheets.




                                                    CAGE CODE            DRAWING NO.                        REV.
                                                        02MQ7                     11081-04104                      1
                                                      SIZE        A          SCALE     NONE        SHEET 3 OF 7


H:\PROPOSAL\12200\12226_Viac_Viacom MTV Hauppauge\procedures\Report 2a - Ant4 5 6 11 RF Hazard Report.doc


        1.3.3 Environmental
        In general, the tests described herein are designed to be conducted under the
        normal environmental conditions at Viacom.

        1.3.4 Equipment Calibration

        Test equipment calibration data must be recorded prior to each test. Within
        each test procedure, a reminder prompts the test engineer to record all
        calibration information for each piece of equipment used to perform the test.
        Record all applicable test equipment calibration data in the following table.
        (Note: If the same unit is used repeatedly, only record the data once.)

    Description (Manufacturer)                Model Number            Serial Number           Calibration Date

Narda –                                       NAR/NBM-                On File               Current
Meter P/N 2403/01B                            520:A                   D-0564                2/18/17

Probe P/N 2402/07B                            EA 5091                 01073                 1/30/17




                                                    CAGE CODE            DRAWING NO.                        REV.
                                                        02MQ7                     11081-04104                      1
                                                      SIZE        A           SCALE    NONE        SHEET 4 OF 7


H:\PROPOSAL\12200\12226_Viac_Viacom MTV Hauppauge\procedures\Report 2a - Ant4 5 6 11 RF Hazard Report.doc


2. APPLICABLE DOCUMENTS

The following documents of the specified or current applicable issue apply to the extent
as specified herein.

        Globecomm Documents

        11081-01000                System Block Diagram
        11081-04104                Test Procedure/Results

        Reference Documents

        Bulletin No. 65            FCC Office of Engineering and Technology (latest version)
        ANSI                       Applicable ANSI regulations as required for Viacom
        SSOG210                    Intelsat Antenna Verification Tests
        25.209                     FCC Standard for ground segment antennas

        Manufacturer Documents

        Narda                      RF Survey Meter, NAR/NBM-520:A




                                                    CAGE CODE            DRAWING NO.                        REV.
                                                        02MQ7                     11081-04104                      1
                                                      SIZE        A          SCALE     NONE        SHEET 5 OF 7


H:\PROPOSAL\12200\12226_Viac_Viacom MTV Hauppauge\procedures\Report 2a - Ant4 5 6 11 RF Hazard Report.doc


2.1 Radiation Hazard Test


        2.1.1 Purpose
                 This procedure outlines the steps to ensure that measured RF radiation
                 does not exceed specified levels.

        2.1.2 Specification
                 +5mW/cm2 per FCC Office of Engineering and Technology Bulletin No.
                 65, 1997.

        2.1.3 Test Equipment
                 The following test equipment, or equivalent, is required to perform the
                 tests described herein.

                          Radiation Monitor and Probe, Narda Model NAR/NBM-520:A


        2.1.4 Procedure
                 This section outlines the proper step-by-step test procedure. Verify or
                 record each step that is indicated on the Test Data Sheet.

                 1. Before starting, insure that the test equipment is calibrated and is set
                    to measure the appropriate radiation levels expected. Refer to the
                    Narda Operation Manual.

                 2. Test in conjunction with the Viacom operations team. With the antenna
                    pointed on the spacecraft, confirm all applicable carriers are operating
                    through the uplink paths at nominal operating levels.

                 3. Take measurements at the specified locations indicated on the Test
                    Data Sheet. All measurements must be less than the specification
                    listed agreed to with Viacom based on their FCC licenses and safety
                    levels in a controlled environment.

                 4. Report immediately and levels that exceed the requirements of the
                    Test Plan, turn off the transmitters to verify that the source is external
                    to the earth station.

                 Note: Charge Radiation Monitor’s battery for 8-12hrs prior to testing.



                                                    CAGE CODE            DRAWING NO.                        REV.
                                                        02MQ7                     11081-04104                      1
                                                      SIZE        A          SCALE     NONE        SHEET 6 OF 7


H:\PROPOSAL\12200\12226_Viac_Viacom MTV Hauppauge\procedures\Report 2a - Ant4 5 6 11 RF Hazard Report.doc


         Test Data Sheet – Record highest value read (all values in mW/cm2).
        Measurement          Ant4         Ant5            Ant6        Ant11
          Location       11M, SA8016B 11M, SA8016B 11M, SA8016B 11M, SA8016B


          30’ behind                0.005               0.005               0.003               0.006
           antenna
        Each corner of           .003     .004       .005     .004       .002     .004       .005     .004
         Antenna Pad
          (mW/cm2)
                                 .002     .007       .004     .003       .004     .005       .005     .005




      On antenna Hub                0.005               0.006               0.005               0.003
         Platform

        Outside Rear                0.004               0.003               0.002               0.005
        Antenna Hub
       (approx. 3’ from
         feed flange)

         Bottom rear                0.004               0.003               0.004               0.004
          (beneath)
      reflector (6’ high,
        6’ back from
            edge)

        30’ in front of             0.005               0.003               0.002               0.005
      reflector (6’high)


Comments:

    1) Pass / Fail (circle one)

    2) Comments/Observations (record here): Conclusion: Based on the above
       analysis, it is concluded that harmful levels of radiation will not exist in regions
       normally occupied by the public or the earth station's operating personnel.




        Test Performed By:                                   __
        Date: ___5/10/16______

                                                    CAGE CODE            DRAWING NO.                        REV.
                                                        02MQ7                     11081-04104                      1
                                                      SIZE        A          SCALE     NONE         SHEET 7 OF 7


H:\PROPOSAL\12200\12226_Viac_Viacom MTV Hauppauge\procedures\Report 2a - Ant4 5 6 11 RF Hazard Report.doc



Document Created: 2016-06-09 13:42:42
Document Modified: 2016-06-09 13:42:42

© 2025 FCC.report