1     Overview
      Determining the region around an antenna where radiation hazardous to human health is a consideration of many
      factors. With a parabolic dish antenna, the region is highly directional and the actual hazardous region is dependent
      on the antenna elevation angle. The following formulae are used to determine the near and far field regions. These
      regions are in the main beam of the radiation pattern, which we will assume consists of a conical angle extending +/- 3
      degrees from the center axis of the antenna.

      The analysis contained herein predicts the radiation levels around the proposed antenna. The calculations contained
      in this report are in accordance with FCC guidelines as contained in CFR 47 Part 1.1310 and OET Bulletin 65. The
      maximum level of non-ionizing radiation to which the general public is exposed is defined for controlled and
      uncontrolled environments as follows:
                                                                                                                       Exposure Limit
      Environment                                                                                              Power        Duration
      Controlled - (applicable to system operators and technicians in the service area of the antenna):        5 mW/cm2     6 Minutes

      Uncontrolled - (applicable to general public in proximity of the antenna):                                     1 mW/cm2        30 Minutes



2.1   Earth Station Technical Parameters - Input Data

          1A        Antenna Diameter - Standard Parabola                     2.4         meters
          1B        Antenna Diameter - Elliptical Reflector                              meters
            1B1       Major Axis Diameter                                                meters
            1B2       Minor Axis Diameter                                                meters
           2        G = Antenna Isotropic Gain                               49.2        dBi
           3        h = Nominal Antenna Efficiency                            68         Percent
           4        Nominal Frequency                                        14.25       GHz
           5        Maximum Transmit Power Amplifier Size                   300.00       Watts
           6        Number of Carriers                                         1         each
           7        W/G Loss from Transmitter to Feed                          0         dB
           8        Multicarrier Fixed Backoff                                 0         dB
           9        Desired Object Clearance Height                            2         meters

2.2   Earth Station Technical Parameters - Calculated Data
          10        A = Antenna Surface Area                                      4.52   sq meters
           10A        Standard Parabolic Reflector                       4.523893421     sq meters
           10B        Elliptical Reflector                                        0.00   sq meters
          11        D = Effective Antenna Diameter                                 2.4   meters
          12        Total Transmit Power                                       300.00    Watts
          13        P = Total Feed Input Power (watts)                         300.00    Watts
          14        E = Maximum E/S EIRP - Calculated                            73.97   dBW
          15        λ = Wavelength (= c/f in m/GHz)                            0.0210    m/GHz
          16        p = Pi                                                    3.14159
          17        Rnf = Near Field Limit (D2/4λ)                                  68 meters                   223 feet
          18        Rff = Far Field Limit (Rff=0.6D2/λ )                           164 meters                   538 feet
          19        Rnf to Rff = Transition Region                           68 to 164 meters            223 to 538 feet



3     Power Density at the Antenna Surface
      The power density at the reflector surface is expected to exceed the safe limits. The reflector is not accessible to the
      public and will not present a hazard. Terminal operators and technicians receive training identifying the area as
      presenting high exposure levels. Procedures are incorporated requiring that transmitters are not operating when
      access to the reflector surface is required.

      The power density at the antenna reflector surface can be calculated by the expression:
                PDREFL = 4P/A =                                                                                                  26.53 mW/cm2
      Where:         P = Total power at the feed, milliwatts
                     A = Total area of reflector, sq cm
      Evaluation:
                    Controlled Environment (less than 5 mW/cm2 in 6 minutes):                                                     HAZARD
                    Uncontrolled environment (less than 1 mW/cm2 in 30 minutes):                                           Mitigation Required



4     On-Axis Power Density in the Near Field Region
      The Radiating Near Field Region for a parabolic, circular reflector, is defined as extending from the reflector to
      a distance equal to the diameter squared divided by twice the wavelength. This distance is referred to as the
      Rayleigh distance. In this region the power is nearly all contained within a cylinder of radius 0.5D. As a safety
      measure the highest possible power density is applied to the whole of this region.

      The power density in the Near Field Region of the antenna can be calculated by the expression:


                  16*P*h/̟*D2 =                                                                                           18.04 mW/cm
                                                                                                                                     2

    Where:          P = Total power at the feed, milliwatts
                    h = Nominal antenna efficiency
                    D = Effective antenna diameter, meters

    Evaluation:
                  Controlled Environment (less than 5 mW/cm2 in 6 minutes):                                                 HAZARD
                  Uncontrolled environment (less than 1 mW/cm2 in 30 minutes):                                        Mitigation Required



5   On-Axis Power Density in the Transition Region
    The transition region is located between the Near Field and Far Field regions. The power density begins to vary
    inversely with distance from the antenna in the transition region. The maximum power density in this region will not
    exceed the power density calculated for the Near Field region. Once again the power density figures are for the On-
    Axis and contained with a cylinder extending within +/- 1 degree of beam center. Where the antennas are normally
    operated at an elevation angle typically greater than 10°, the actual safe distance in front of the antenna may be found
    in paragraph 10. The formula for the calculation is used to evaluate the power density at any given distance in the
    transition as expressed below:

    The power density in the On-Axis Transition Region can be calculated by the expression:
              PDt=(PDnf)(Rnf)/R
    Where:          PDnf = The Near Field power density, mW/cm2
                    Rnf = Near Field maximum distance, meters
                    R = Distance to point of interest
    For:            68 < R < 164 meters

    Evaluation:
                  Controlled Environment Safe Operating Distance, meters:                                                  245 meters
                  Uncontrolled environment Safe Operating Distance, meters:                                               1227 meters



6   On-Axis Power Density in the Far Field Region
    The On-Axis power density in the far field region (PDff) varies inversely with the square of the distance. The
    calculation is performed below:

    The Power Density at the start of the Far Field region can be calculated by the expression:
                  E-10log(4pR2)                                                                                           18.68 dBW/m2
                  antilog((E-10log(4pR2)/10)/10                                                                            7.38 mW/cm
                                                                                                                                     2




    Evaluation:
                  Controlled Environment (less than 5 mW/cm2 in 6 minutes):                                                 HAZARD
                  Uncontrolled environment (less than 1 mW/cm2 in 30 minutes):                                        Mitigation Required



7   Off-Axis Power Density Levels at the Far Field Limit and Beyond
    In the far field region, the power is distributed in a pattern of sidelobes as a function of the off-axis angle between the
    antenna center line and the point of interest. Off-axis power density in the far field can be estimated using the antenna
    radiation patterns prescribed for the antenna in use. Usually this will correspond to the antenna gain pattern envelope
    defined by the FCC or the ITU, which takes the form of:
                  Goff = 32 - 25log(θ)
                for θ from 1 to 48 degrees; -10 dBi from 48 to 180 degrees
                (Applicable for commonly used satellite transmit antennas)
    For example: At one (1) degree off axis At the far-field limit, we can calculate the power density as:
                  Goff = 32 - 25log(1) = 32 - 0 dBi =                                                                     1585 numeric
                  PD1 deg off-axis = PDffx 1585/G                                                                       0.1407 mW/cm²

    Evaluation:
    Considering that satellite antenna beams are aimed skyward, power density in the far field will usually not be a
    problem except at low look angles. In these cases, off axis gain reduction techniques may be used to further reduce the
    power density levels.



8   Off-Axis Power Density Levels at the Near Field and Transitional Regions
    According to Bulletin 65, off-axis calculations in the near field may be performed as follows: assuming that the point of
    interest is at least one antenna diameter removed from the center of the main beam, the power density at that point is
    at least a factor of 100 (20 dB) less than the value calculated for the near field main beam power density. This may be
    calculated as follows:
                 PDnf(off-axis) = PDnf/100 =                                                                           0.1804 mW/cm²



9   Region Between the Feed Horn and Reflector/Sub-Reflector
    Transmissions from the feed horn are directed toward the main reflector or the sub-reflector depending on the type of
    antenna (prime focus, Gregorian or Cassegrain). The transmission is confined within a conical shape defined by the
    feed horn. The energy between the feedhorn and the reflector/sub-reflector is assumed to be in excess of any limit for


     feed horn. The energy between the feedhorn and the reflector/sub-reflector is assumed to be in excess of any limit for
     permissible exposure. This region is not accessible to the general public, and operators and technicians should be
     suitable trained and procedures in place to preclude access to this region during active transmission.



10   Evaluation of Safe Occupancy Area in Front of the Antenna
     The distance (L) from a vertical axis passing through the dish center to a safe off-axis point in front of the antenna can
     be determined based on the dish diameter. Assuming a flat terrain and a point on the horizontal plane with the center
     point of the antenna, the relationship is determined by the following formula:
                L = (D/sin a) + (2h - D - 2)/(2 tan a)
      Where:    a = minimum elevation angle of antenna
                D = Dish diameter in meters
                h = Maximum height of object to be cleared, meters
     For distances equal to or greater than determined by the equation above, the radiation hazard will be below safe levels

        For:     D=                                                              2.4 meters
                 h=                                                                2 meters
     Safe distance for the following elevation angles (a):
                            a - Elevation Angle (degrees)                 L - Safe Distance
                                          10                              12.69     meters
                                          15                              8.53      meters
                                          20                              6.47      meters
                                          25                              5.25      meters
                                          30                              4.45      meters
                                          40                              3.50      meters
                                          50                              2.97      meters
                                         5.00                             25.25     meters         Site Specific


11   Mitigation Analysis
     Mitigation of accessibility to hazardous regions may take several forms depending on the antenna application and
     location. In instances such as mobile applications, the antenna may be located such that the hazardous region is not
     accessible during operation. An example may be in a mobile configuration where the antenna is located on top of a
     vehicle during operation. In other fixed installation instances the hazardous area may be fenced off to prevent access.
     In areas where only operators and technicians have access, training in safeguards and proper markings of hazardous
     areas may be sufficient. This analysis tool is designed to identify the hazardous exposure regions around an operating
     antenna system in accordance with the defined power density limits in CFR 47, part 1.1310 and OET bulletin 65.


12   Conclusion

     Based upon the above analysis, it is concluded that harmful levels of radiation may exist in those regions noted for
     both the Controlled and Uncontrolled environment.

     The earth station will be surrounded by a barrier, which will restrict any public access. The earth station will be
     marked with standard radiation hazard warnings, as well as the area in the vicinity of the earth station to inform
     those in the general population, who might be working or otherwise present in or near the direct path of the main
     beam.

     The applicant will ensure the main beam of the antenna will be pointed at least one diameter away from any building,
     or other obstacles in those areas that exceed the MPE levels. Since one diameter removed from the center of the main
     beam will lower levels by at least 20 dB, or by a factor of 100, these potential hazards do not exist for either the public,
     or for the earth station personnel.

     Finally, the earth station's operating personnel will not have access to areas that exceed the MPE levels, while the earth
     station is in operation. The transmitter will be turned off during periods of maintenance, so that the MPE standard of