Attachment Radhaz Reports

This document pretains to SES-MOD-20150410-00212 for Modification on a Satellite Earth Station filing.

IBFS_SESMOD2015041000212_1081597

                                                                                  Exhibit
Radiation Hazard Report                                                           Page 1 of 15


     Analysis of Non-Ionizing Radiation for a 11.0-Meter Earth
                  Station System (RSI Satcom)
This report analyzes the non-ionizing radiation levels for a 11.0-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                 Value            Units
     Antenna Diameter                D               Input                  11.0            m
     Antenna Surface Area          Asurface         π D2 / 4               95.03            m2
     Subreflector Diameter          Dsr              Input                 121.9            cm
     Area of Subreflector           Asr             π Dsr 2/4            11670.71           cm2
     Frequency                       F               Input                  6175            MHz
     Wavelength                      λ              300 / F              0.048583           m
     Transmit Power                  P               Input                2454.71           W
     Antenna Gain (dBi)             Ges              Input                  55.4            dBi
     Antenna Gain (factor)           G              10Ges/10             346736.9           n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)               0.69            n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 2 of 15




1. Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 / λ                    (1)
                                                                = 1494.4 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4 π Rff 2)              (2)
                                                                = 30.331 W/m2
                                                                = 3.033 mW/cm2

2. Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 λ)                     (3)
                                                                = 622.6 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0 η P / (π D2)              (4)
                                                                = 70.806 W/m2
                                                                = 7.081 mW/cm2

3. Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                    (5)
                                                               = 7.081 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 3 of 15

Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                 (6)
                                                              = 841.323 mW/cm2

4. Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface              (7)
                                                               = 103.320 W/m2
                                                               = 10.332 mW/cm2


5. Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                  (8)
                                                             = 25.830 W/m2
                                                             = 2.583 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 4 of 15

6. Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1494.4 m)                   Sff        3.033             Potential Hazard
2. Near Field (Rnf = 622.6 m)                   Snf        7.081             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St         7.081              Potential Hazard
4. Between Main Reflector and                   Ssr      841.323             Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface  10.332             Potential Hazard
6. Between Main Reflector and Ground            Sg         2.583             Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1494.4 m)                  Sff         3.033            Satisfies FCC MPE
2. Near Field (Rnf = 622.6 m)                  Snf         7.081             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)          St          7.081             Potential Hazard
4. Between Main Reflector and                  Ssr      841.323              Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface  10.332              Potential Hazard
6. Between Main Reflector and Ground           Sg          2.583            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



7. Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Vernon Valley
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                          Exhibit
Radiation Hazard Report                                                                   Page 5 of 15

Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station
                   tion is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure th that
                                                                                       at the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be ddetermined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line
                       line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, includin
                                                                    including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH
19700 Janelia Farm Boulevard
Ashburn, VA 20147


DATED: March 29, 2015


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 6 of 15

     Analysis of Non-Ionizing Radiation for a 11.0-Meter Earth
                Station System (Scientific-Atlanta)
This report analyzes the non-ionizing radiation levels for a 11.0-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                 Value            Units
     Antenna Diameter                D               Input                  11.0            m
     Antenna Surface Area          Asurface         π D2 / 4               95.03            m2
     Subreflector Diameter          Dsr              Input                 121.9            cm
     Area of Subreflector           Asr             π Dsr 2/4            11670.71           cm2
     Frequency                       F               Input                  6175            MHz
     Wavelength                      λ              300 / F              0.048583           m
     Transmit Power                  P               Input                2454.71           W
     Antenna Gain (dBi)             Ges              Input                  55.0            dBi
     Antenna Gain (factor)           G              10Ges/10             316227.8           n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)               0.63            n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 7 of 15



8. Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 / λ                    (1)
                                                                = 1494.4 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4 π Rff 2)              (2)
                                                                = 27.662 W/m2
                                                                = 2.766 mW/cm2

9. Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 λ)                     (3)
                                                                = 622.6 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0 η P / (π D2)              (4)
                                                                = 64.576 W/m2
                                                                = 6.458 mW/cm2

10.    Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                    (5)
                                                               = 6.458 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 8 of 15

Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                 (6)
                                                              = 841.323 mW/cm2

11.    Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface              (7)
                                                               = 103.320 W/m2
                                                               = 10.332 mW/cm2


12.    Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                  (8)
                                                             = 25.830 W/m2
                                                             = 2.583 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 9 of 15

13.    Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1494.4 m)                   Sff        2.766             Potential Hazard
2. Near Field (Rnf = 622.6 m)                   Snf        6.458             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St         6.458              Potential Hazard
4. Between Main Reflector and                   Ssr      841.323             Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface  10.332             Potential Hazard
6. Between Main Reflector and Ground            Sg         2.583             Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1494.4 m)                  Sff         2.766            Satisfies FCC MPE
2. Near Field (Rnf = 622.6 m)                  Snf         6.458             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)          St          6.458             Potential Hazard
4. Between Main Reflector and                  Ssr      841.323              Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface  10.332              Potential Hazard
6. Between Main Reflector and Ground           Sg          2.583            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



14.    Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Vernon Valley
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                          Exhibit
Radiation Hazard Report                                                                   Page 10 of 15

Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station
                   tion is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure th that
                                                                                       at the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be ddetermined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line
                       line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, includin
                                                                    including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH
19700 Janelia Farm Boulevard
Ashburn, VA 20147


DATED: March 29, 2015


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 11 of 15

     Analysis of Non-Ionizing Radiation for a 13.1-Meter Earth
                     Station System (Vertex)
This report analyzes the non-ionizing radiation levels for a 13.1-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                 Value            Units
     Antenna Diameter                D               Input                  13.1            m
     Antenna Surface Area          Asurface         π D2 / 4               134.78           m2
     Subreflector Diameter          Dsr              Input                  133.0           cm
     Area of Subreflector           Asr             π Dsr 2/4            13892.91           cm2
     Frequency                       F               Input                  6175            MHz
     Wavelength                      λ              300 / F              0.048583           m
     Transmit Power                  P               Input                1778.30           W
     Antenna Gain (dBi)             Ges              Input                  56.8            dBi
     Antenna Gain (factor)           G              10Ges/10             478630.1           n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)               0.67            n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 12 of 15



15.    Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 / λ                     (1)
                                                                = 2119.4 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4 π Rff 2)               (2)
                                                                = 15.079 W/m2
                                                                = 1.508 mW/cm2

16.    Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 λ)                      (3)
                                                                = 883.1 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0 η P / (π D2)               (4)
                                                                = 35.201 W/m2
                                                                = 3.520 mW/cm2

17.    Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                     (5)
                                                               = 3.520 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 13 of 15

Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                  (6)
                                                              = 512.002 mW/cm2

18.    Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface               (7)
                                                               = 52.776 W/m2
                                                               = 5.278 mW/cm2


19.    Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                   (8)
                                                             = 13.194 W/m2
                                                             = 1.319 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 14 of 15

20.    Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 2119.4 m)                   Sff        1.508             Potential Hazard
2. Near Field (Rnf = 883.1 m)                   Snf        3.520             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St         3.520              Potential Hazard
4. Between Main Reflector and                   Ssr      512.002             Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   5.278              Potential Hazard
6. Between Main Reflector and Ground            Sg         1.319             Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 2119.4 m)                  Sff         1.508            Satisfies FCC MPE
2. Near Field (Rnf = 883.1 m)                  Snf         3.520            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)          St          3.520            Satisfies FCC MPE
4. Between Main Reflector and                  Ssr      512.002              Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface    5.278             Potential Hazard
6. Between Main Reflector and Ground           Sg          1.319            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



21.    Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Vernon Valley
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                          Exhibit
Radiation Hazard Report                                                                   Page 15 of 15

Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station
                   tion is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure th that
                                                                                       at the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be ddetermined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line
                       line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, includin
                                                                    including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH
19700 Janelia Farm Boulevard
Ashburn, VA 20147


DATED: March 29, 2015



Document Created: 2015-03-29 08:51:32
Document Modified: 2015-03-29 08:51:32

© 2024 FCC.report