Attachment RadHaz

This document pretains to SES-MOD-20141126-00876 for Modification on a Satellite Earth Station filing.

IBFS_SESMOD2014112600876_1069932

                                                                                         Exhibit B
Radiation Hazard Report                                                                  Page 1 of 5


      Analysis of Non-Ionizing Radiation for a 4.8-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 4.8-meter earth station system. The analysis and
calculations performed in this report comply with the methods described in the FCC Office of Engineering
and Technology Bulletin, No. 65 first published in 1985 and revised in 1997 in Edition 97-01. The radiation
safety limits used in the analysis are in conformance with the FCC R&O 96-326. Bulletin No. 65 and the
FCC R&O specifies that there are two separate tiers of exposure limits that are dependant on the situation in
which the exposure takes place and/or the status of the individuals who are subject to the exposure. The
Maximum Permissible Exposure (MPE) limits for persons in a General Population/Uncontrolled environment
are shown in Table 1. The General Population/Uncontrolled MPE is a function of transmit frequency and is
for an exposure period of thirty minutes or less. The MPE limits for persons in an Occupational/Controlled
environment are shown in Table 2. The Occupational MPE is a function of transmit frequency and is for an
exposure period of six minutes or less. The purpose of the analysis described in this report is to determine
the power flux density levels of the earth station in the far-field, near-field, transition region, between the
subreflector or feed and main reflector surface, at the main reflector surface, and between the antenna edge
and the ground and to compare these levels to the specified MPEs.


                Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                   Frequency Range (MHz)            Power Density (mW/cm2)
                           30-300                                0.2
                          300-1500                    Frequency (MHz)*(0.8/1200)
                        1500-100,000                             1.0

                     Table 2. Limits for Occupational/Controlled Exposure (MPE)
                   Frequency Range (MHz)            Power Density (mW/cm2)
                           30-300                                1.0
                          300-1500                    Frequency (MHz)*(4.0/1200)
                        1500-100,000                             5.0


          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                       Symbol            Formula                   Value            Units
     Antenna Diameter                   D                Input                     4.8            m
     Antenna Surface Area             Asurface          π D2 / 4                  18.10           m2
     Subreflector Diameter             Dsr               Input                    36.6            cm
     Area of Subreflector              Asr              π Dsr 2/4               1052.09           cm2
     Frequency                          F                Input                    6175            MHz
     Wavelength                         λ               300 / F                0.048583           m
     Transmit Power                     P                Input                   200.00           W
     Antenna Gain (dBi)                Ges               Input                    47.9            dBi
     Antenna Gain (factor)              G               10Ges/10                61659.5           n/a
     Pi                                 π              Constant                3.1415927          n/a
     Antenna Efficiency                 η              Gλ2/(π2D2)                 0.64            n/a


                                                                                  Exhibit B
Radiation Hazard Report                                                           Page 2 of 5



1.      Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

     Distance to the Far Field Region                       Rff = 0.60 D2 / λ                   (1)
                                                                = 284.5 m

The maximum main beam power density in the far field can be determined from the following
equation:

     On-Axis Power Density in the Far Field                 Sff = G P / (4 π Rff 2)             (2)
                                                                = 12.121 W/m2
                                                                = 1.212 mW/cm2

2.      Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

     Extent of the Near Field                               Rnf = D2 / (4 λ)                    (3)
                                                                = 118.6 m

The maximum power density in the Near Field can be determined from the following equation:

     Near Field Power Density                               Snf = 16.0 η P / (π D2)             (4)
                                                                = 28.295 W/m2
                                                                = 2.829 mW/cm2

3.      Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

     Transition Region Power Density                        St = Snf Rnf / Rt                   (5)
                                                               = 2.829 mW/cm2


                                                                              Exhibit B
Radiation Hazard Report                                                       Page 3 of 5



4.      Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

     Power Density at the Subreflector                    Ssr = 4000 P / Asr                (6)
                                                              = 760.393 mW/cm2


5.      Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

     Power Density at the Main Reflector Surface      Ssurface = 4 P / Asurface             (7)
                                                               = 44.210 W/m2
                                                               = 4.421 mW/cm2


6.      Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

     Power Density between Reflector and Ground           Sg = P / Asurface                 (8)
                                                             = 11.052 W/m2
                                                             = 1.105 mW/cm2


                                                                             Exhibit B
Radiation Hazard Report                                                      Page 4 of 5



7.     Summary of Calculations

          Table 4. Summary of Expected Radiation levels for Uncontrolled Environment

                                            Calculated Maximum
                                        Radiation Power Density Level
Region                                             (mW/cm2)                Hazard Assessment
1. Far Field (Rff = 284.5 m)                   Sff      1.212                Potential Hazard
2. Near Field (Rnf = 118.6 m)                  Snf      2.829                Potential Hazard
3. Transition Region (Rnf < Rt < Rff)          St       2.829                Potential Hazard
4. Between Main Reflector and                  Ssr    760.393                Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   4.421             Potential Hazard
6. Between Main Reflector and Ground            Sg         1.105             Potential Hazard



           Table 5. Summary of Expected Radiation levels for Controlled Environment

                                            Calculated Maximum
                                           Radiation Power Density
Region                                         Level (mW/cm2)             Hazard Assessment
1. Far Field (Rff = 284.5 m)                   Sff       1.212             Satisfies FCC MPE
2. Near Field (Rnf = 118.6 m)                  Snf       2.829             Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)          St        2.829             Satisfies FCC MPE
4. Between Main Reflector and                  Ssr     760.393              Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   4.421           Satisfies FCC MPE
6. Between Main Reflector and Ground            Sg         1.105           Satisfies FCC MPE




It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.


                                                                                      Exhibit B
Radiation Hazard Report                                                               Page 5 of 5



8.     Conclusions

Based upon the above analysis, it is concluded that FCC RF Guidelines have been exceeded in
the specified region(s) of the Uncontrolled Environment (Table 4). The applicant proposes to
comply with the Maximum Permissible Exposure (MPE) limits of 1.0 mW/cm**2 for the
Uncontrolled Areas, and the MPE limits of 5.0 mW/cm**2 for the Controlled Areas.

The earth station is installed at the Applicants facility in Hauppauge, New York. The earth station is
located on the roof of a 30 foot building, and public access to that roof is restricted.

The applicant will ensure that the main beam of the antenna will be pointed at least one diameter
away from any buildings, or other obstacles in those areas that exceed the MPE levels. Since one
diameter removed from the center of the main beam the levels are down at least 20 dB, or by a
factor of 100, public safety will be ensured.

The earth station will marked with the standard radiation hazard warnings, as well as the area in
the vicinity of the earth station, to inform those in the general population, who may be working, or
otherwise present on the roof, and in or near, the main beam of the antenna.

Finally, occupational exposure will be limited, and the transmitter will be turned off during periods
of maintenance, so that the MPE standard of 5.0 mw/cm**2 will be complied with for those regions
in close proximity to the main reflector, and subreflector, which could be occupied by operating
personnel.

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

       Condition 5208 - The licensee shall take all necessary measures to ensure that the
       antenna does not create potential exposure of humans to radiofrequency radiation
       in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
       wherever such exposures might occur. Measures must be taken to ensure
       compliance with limits for both occupational/controlled exposure and for general
       population/uncontrolled exposure, as defined in these rule sections. Compliance
       can be accomplished in most cases by appropriate restrictions such as fencing.
       Requirements for restrictions can be determined by predictions based on
       calculations, modeling or by field measurements. The FCC's OET Bulletin 65
       (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting
       exposure levels and on methods for ensuring compliance, including the use of
       warning and alerting signs and protective equipment for worker.