Attachment Exhibit A

This document pretains to SES-MOD-20120917-00834 for Modification on a Satellite Earth Station filing.

IBFS_SESMOD2012091700834_966137

                                              Exhibit A

                                     Radiation Hazard Analysis


Per the instructions in the Environmental Policy section of FCC Form 312, a Radiation Hazard Analysis
performed in accordance with The Office of Engineering and Technology (OET) Bulletin No. 65 (August
1997) is attached.


                                                                  Exhibit A - Radiation Hazard Study



                                                       ANALYSIS OF NON‐IONIZING RADIATION
                                                 FOR AN 8.1 METER KU‐BAND EARTH STATION ANTENNA
                                                               Completed 09/10/2012

This report analyzes the non‐ionizing radiation levels for a 8.1m Ku‐band earth station antenna. The analysis and calculations performed in this
report comply with the methods described in the FCC Office of Engineering and Technology Bulletin, No. 65 entitled "Evaluating Compliance with
FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields" ‐ first published in 1985 and revised in 1997 in Edition 97‐01.
Bulletin No. 65 specifies that there are two separate tiers of exposure limits that are dependant on the situation in which the exposure takes place
and/or the status of teh individuals who are subject to the exposure. The Maximum Permissible Exposure (MPE) limits for persons in a General
Population/Uncontrolled Environment are shown in Table 1, below. The General Population/Uncontrolled MPE is a function of the transmit
frequency and is for an exposure period of thirty (30) minutes or less. The MPE limits for persons in an Occupational/Controlled environment are
shown in Table 2, below. The Occupational/Controlled MPE is a function of the transmit frequency and is for an exposure period of six (6) minutes
or less. The purpose of the analysis described in this report is to determine the power flux density levels of the earth station ni the far‐field, near‐
field, transition region, between the subreflector or feed and the main reflector surface, and at the main reflector surface and to compare these
levels to the specified MPE limits.

The results of this analysis are summarized in Table 3 on the last page of this analysis.

                                                Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                                                 Frequency Range (MHz)                                 Power Density(mW/cm2)
                                                        30‐300                                                   0.2
                                                       300‐1500                                         Frequency (MHz)/1500
                                                     1500‐100,000                                               1.0

                                                     Table 2. Limits for Occupational/Controlled Exposure (MPE)
                                                 Frequency Range (MHz)                                 Power Density(mW/cm2)
                                                        30‐300                                                  1.0
                                                       300‐1500                                         Frequency (MHz)/300
                                                     1500‐100,000                                               5.0

The following parameters were used to calculate the various power flux densities for this earth station:

           Location:                                  Anchorage, Alaska
           Latitude:                                  61.188056 °N
           Longitude:                                 149.88167 °W
           Operating Frequency:                          14250 MHz
           Wavelength (λ)                               0.02104 meters
           Antenna Diameter (D):                          8.10   meters
           Antenna Area (A):                             51.53   meters²
           Transmit Antenna Gain:                         59.8   dBi
           Transmit Antenna Gain (G):                  954992.6 numeric
           Maximum 5° Off Axis Gain:                      11.5   dBi
           Maximum 5° Off Axis Gain (G5°):                14.2   numeric
           Antenna Efficiency (ƞ):                       0.653   numeric
           Feed Power (P):                                500    Watts


1. Antenna/Main Reflector Surface Calculation
The power density in the main reflector region can be estimated by
                                                           Antenna Diameter
                                                            8.10   meters
  Power Density at Reflector Surface,        Ssurface = 4P/A
                                             Ssurface =    38.81   W/m²
                                             Ssurface =    3.88    mW/cm²
   Ssurface = maximum power density at antenna surface
         P = power fed to the antenna
         A = physical area of the antenna
2. Near Field Calculations
In the near field region, of the main beam, the power density can reach a maximum before it begins to decrease with distance
The magnitude of the on axis (main beam) power density varies according to location in the near‐field
The distance to the end of the near field can be determined by the following equation:
                                                         Antenna Diameter
                                                         8.10    meters
                  Extent of Near Field,         Rnf = D²/4(λ)
                                                Rnf = 779.66 meters
      Rnf = extent of near field


                                                                                                                                             Exhibit A Page 1 of 3


                                                                         Exhibit A - Radiation Hazard Study

        D = maximum dimension of antenna (diameter if circular)
        λ = wavelength
The maximum near‐field, on‐axis, power density is determined by:
                                                             Antenna Diameter
                                                              8.10   meters
    On Axis Near Field Power Density,                Snf = 16ƞP/πD²
                                                     Snf =   25.33   W/m²
                                                     Snf =    2.53   mW/cm²
The maximum near‐field, 5° off‐axis, power density is determined by:
                                                              Antenna Diameter
                                                               8.10    meters
                Power Density at 5° Off Axis       Snf 5°= (Snf/G)*G5°
                                                   Snf 5°= 0.0000 mW/cm²
       Snf=     maximum near‐field power density
     Snf 5° =   maximum near‐field power density (5° off axis)
         ƞ=     aperture efficiency
         P=     power fed to antenna
        D=      maximum dimension of antenna (diameter if circular)

3. Far Field Calculations

The power density in the far‐field region decreases inversely with the square of the distance

The distance to the beginning of the far field region can be found by the following equation:

                                                           Antenna Diameter
                                                              8.10    meters
      Distance to the Far Field Region,              Rff = 0.6D²/λ
                                                     Rff = 1871.18 meters

       Rff = distance to beginning of far field
        D = maximum dimension of antenna (diameter if circular)
        λ = wavelength

The maximum main beam power density in the far field can be calculated as follows:
                                                              Antenna Diameter
                                                                8.10    meters
                                                                         2
On‐Axis Power Density in the Far Field,              Sff = (P)(G)/4π(Rff)
                                                     Sff =     10.85    W/m²
                                                     Sff =     1.09     mW/cm²
The maximum far‐field, 5° off‐axis, power density is determined by:
                                                               Antenna Diameter
                                                                8.10    meters
            Power Density at 5° Off Axis            Sff 5°= (Sff/G)*G5°
                                                    Sff 5°= 0.0000 mW/cm²
       Sff=     power density (on axis)
     Sff 5°=    power density (5° off axis)
         P=     power fed to antenna
         G=     power gain of antenna in the direction of interest relative to an isotropic radiato
      Rff =     distance to beginning of far field

4. Transition Region Calculations

The transition region is located between the near and far field regions. The power density decreases inversely with distance in the transition region,
while the power density decreases inversely with the square of the distance in the far‐field region. The maximum power density in the transition region
will not exceed that calculated for the near‐field region. The power density in the near field region, as shown above will not exceed:

                                                                  Antenna Diameter
                                                                   8.10      meters
                                                       St=    (Snf*Rnf)/R
                                                    St 5° =   (Snf 5°*Rnf)/R
                                                       St=         2.53      mW/cm²
                                                    St 5° =      0.0000 mW/cm²




                                                                                                                                          Exhibit A Page 2 of 3


                                                                  Exhibit A - Radiation Hazard Study

                                                                           Table 3
                                                         Summary of Expected Radiation Levels
                                         Calculated Maximum                      Distance to           Maximum Permissible Exposure (MPE
Region                                 Radiation Level (mW/cm²                   Region (m)            Occupational       General Population
8.1m Earth Station Antenna
 1. Antenna Surface                         Ssurface=    3.88                                          Satisfies MPE           Potential Hazard
 2. Near Field                                   Snf=    2.53                         779.7            Satisfies MPE           Potential Hazard
 3. Far Field                                    Sff=    1.09                        1871.2            Satisfies MPE           Potential Hazard
 4. Transition Region                             St=    2.53                                          Satisfies MPE           Potential Hazard
 5. Near Field 5° Off Axis                    Snf 5°=    0.0000                                        Satisfies MPE            Satisfies MPE
 6. Far Field 5° Off Axis                     Sff 5°=    0.00                                          Satisfies MPE            Satisfies MPE
 7. Transition Region 5° Off Axis              St 5° =   0.0000                                        Satisfies MPE            Satisfies MPE



7. Conclusions
Based on the above analysis, it is concluded that the OET/FCC Radiofrequency Electromagnetic Fields guidelines for Maximum Permissible Exposure
(MPE) have been exceeded in the region(s) specified in Table 3. However, it should be noted that General Population/Uncontrolled MPE limit is always
satisifed at angles 5° off of boresite or greater. As this earth station antenna will never be operated with an elevation angle of less than the minimum
specified in 47 C.F.R. Ch. 1 §25.205 (namely 5°) and the antenna is located on the roof of a building to which the General Population access is restricted,
then the MPE associated with the General Population/Uncontrolled limits will always be satisied. GCI will post appropriate RF Radiation Hazard placards
and other signage in the areas near these antennas and has advised building management to restrict access to the small area between the front of the
antenna and the side of the building. Finally, access to the antenna surface, as well as the region between the feedhorn and the antenna surface will be
restricted to qualified personnel and the transmitter will be disabled during maintenance activities in these areas to protect personnel from exposure.




                                                                  Andrew F. Rzeszut (9‐10‐2012)
                                                                  Senior Staff Engineer
                                                                  GCI Communication Corp.




                                                                                                                                           Exhibit A Page 3 of 3



Document Created: 2012-09-10 14:03:50
Document Modified: 2012-09-10 14:03:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC