Attachment Revised Rad Had

This document pretains to SES-MOD-20051007-01380 for Modification on a Satellite Earth Station filing.

IBFS_SESMOD2005100701380_460386

FCC OET-65 RF Exposure Study - Satellite Uplink Facility
WVIT Modified Uplink Facility E873926 – 1.5 meter SNG antenna w/ 80 watt antenna mounted amplifier

FCC Maximum Permissible Exposure Levels                   Source                      Units        Notes
Public/uncontrolled area exposure limit                   47CFR §1.1310             1 mW/cm2
Occupational/controlled area exposure limit               47CFR §1.1310             5 mW/cm2

Input Data
Antenna Diameter                                          datasheet              150.0 cm
Antenna surface area                                      calculated            17671 cm2
Feed flange diameter                                      measured               6.350 cm
Feed flange area                                          calculated                32 cm2
Frequency                                                 (entry)               14000 MHz
Wavelength (speed of light = 299,792,458 m/s)             calculated             2.141 cm
Transmit power at flange                                  datasheet             80000 milliwatts
Antenna gain                                              datasheet               45.3 dBi
Antenna gain factor                                       calculated            33884
Height of base of antenna above ground                    measured                2.76 m
Height of center of antenna above ground                  measured                3.51 m
Minimum Elevation Angle                                   (entry)                    5 degrees
Minimum Elevation Angle                                   calculated          0.08727 radians
                                                                                                      FCC Maximum Permissible Exposure (MPE)
Results calculated using FCC Bulletin OET-65 (Edition 97-01 August 1997)                                Uncontrolled            Controlled
Maximum power density at antenna surface               Eq. 11 Pg 27             18.11 mW/cm2           Potential Hazard      Potential Hazard
Power density at feed flange                           Eq. 11 Pg 27          10104.45 mW/cm2           Potential Hazard      Potential Hazard
Extent of near-field                                   Eq. 12 Pg 27              2627 cm
Maximum new-field power density                        Eq. 13 Pg 28             12.67 mW/cm2           Potential Hazard         Potential Hazard
Aperture efficiency                                    Eq. 14 Pg 28                0.7
Distance to beginning of far-field                     Eq. 16 Pg 29           6304.36 cm
Power density at end of the transition regiion         Eq. 17 Pg 29               5.28 mW/cm2          Potential Hazard         Potential Hazard
Maximum far-field power density                        Eq. 18 Pg 29             5.427 mW/cm2           Potential Hazard         Potential Hazard

Main Beam Far-field region safe exposure distances
Minimum distance for public/uncontrolled exposure         Eq. 18 Pg 29         146.87 meters
   Height at minimum antenna elevation angle              calculated            16.31 meters
   Horizontal distance                                    calculated           146.31 meters

Minimum distance for occupational/controlled exposure     Eq. 18 Pg 29          65.68 meters
   Height at minimum antenna elevation angle              calculated             9.23 meters
   Horizontal distance                                    calculated            65.43 meters

Off-Axis Near Field/Transition Region safe exposure distances from antenna
(20 dB reduction in power density at distances greater
than one antenna diameter from the main beam center.)  OET-65 Pg 30
Maximum off-axis near field power density              Eq. 13 Pg 28            0.1267 mW/cm2           Below FCC MPE            Below FCC MPE
Public/uncontrolled exposure off-axis distance         Diam/or Eq 17               1.5 meters
Occupatonal/controlled exposure off-axis distance      Diam/or Eq 17               1.5 meters

Off-Axis Far Field safe exposure distances from the antenna
(Based on side lobe attenuation required by FCC 25.209(a)(2))
Angle off main beam axis (1 to 48 degrees)                (entry)                   5 degree(s)
     Off-axis antenna gain factor                         OET-65 Pg 30*            28
     Minimum distance for public/uncontrolled exposure    Eq. 18 Pg 29 **       63.04 meters
 * Gain converted from dBi to linear multiple
 ** If calculated distance is less than the start of the
   far field region, the distance to the start of the far
   field region is shown.
                                                                                                              Prepared by Doug Lung, October 19, 2005



Document Created: 2005-10-20 10:59:56
Document Modified: 2005-10-20 10:59:56