Attachment RadHazC

This document pretains to SES-LIC-20190620-00791 for License on a Satellite Earth Station filing.

IBFS_SESLIC2019062000791_1742411

Radiation Hazard Report                                                           Page 1 of 5


      Analysis of Non-Ionizing Radiation for a 4.5-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 4.5-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                 Value          Units
     Antenna Diameter                D               Input                   4.5          m
     Antenna Surface Area          Asurface         π D2 / 4                15.90         m2
     Subreflector Diameter          Dsr              Input                  24.3          cm
     Area of Subreflector           Asr             π Dsr 2/4              463.77         cm2
     Frequency                       F               Input                  6175          MHz
     Wavelength                      λ              300 / F              0.048583         m
     Transmit Power                  P               Input                 350.00         W
     Antenna Gain (dBi)             Ges              Input                  45.0          dBi
     Antenna Gain (factor)           G              10Ges/10              31622.8         n/a
     Pi                              π             Constant              3.1415927        n/a
     Antenna Efficiency              η             Gλ2/(π2D2)               0.37          n/a


Radiation Hazard Report                                                           Page 2 of 5




1. Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 / λ                   (1)
                                                                = 250.1 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4 π Rff 2)             (2)
                                                                = 14.082 W/m2
                                                                = 1.408 mW/cm2

2. Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 λ)                    (3)
                                                                = 104.2 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0 η P / (π D2)             (4)
                                                                = 32.874 W/m2
                                                                = 3.287 mW/cm2

3. Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                   (5)
                                                               = 3.287 mW/cm2


Radiation Hazard Report                                                       Page 3 of 5

4. Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                (6)
                                                              = 3018.739 mW/cm2

5. Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface             (7)
                                                               = 88.026 W/m2
                                                               = 8.803 mW/cm2


6. Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                 (8)
                                                             = 22.007 W/m2
                                                             = 2.201 mW/cm2


Radiation Hazard Report                                                           Page 4 of 5

7. Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 250.1 m)                    Sff         1.408            Potential Hazard
2. Near Field (Rnf = 104.2 m)                   Snf         3.287            Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St          3.287             Potential Hazard
4. Between Main Reflector and                   Ssr      3018.739            Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface    8.803             Potential Hazard
6. Between Main Reflector and Ground            Sg          2.201            Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 250.1 m)                   Sff         1.408            Satisfies FCC MPE
2. Near Field (Rnf = 104.2 m)                  Snf         3.287            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)          St          3.287            Satisfies FCC MPE
4. Between Main Reflector and                  Ssr      3018.739             Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface    8.803             Potential Hazard
6. Between Main Reflector and Ground           Sg          2.201            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



8. Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Means of Compliance Uncontrolled Areas

This antenna will be located in a fenced area. The area will be sufficient to prohibit access to the
areas that exceed the MPE limited. The general public will not have access to areas within ½
diameter removed from the edge of the antenna.

Since one diameter removed from the main beam of the antenna or ½ diameter removed from the
edge of the antenna the RF levels are reduced by a factor of 100 or 20 dB. None of the areas
exceeding the MPE levels will be accessible by the general public.

Radiation hazard signs will be posted while this earth station is in operation.


Radiation Hazard Report                                                        Page 5 of 5


The applicant will ensure that no buildings or other obstacles will be in the areas that exceed the
MPE levels.


Means of Compliance Controlled Areas

The earth stations operational will not have access to the areas that exceed the MPE levels while
the earth station is in operation.

The transmitters will be turned off during antenna maintenance.




The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

Condition 5208 - The licensee shall take all necessary measures to ensure that the antenna does
not create potential exposure of humans to radiofrequency radiation in excess of the FCC
exposure limits defined in 47 CFR 1.1307(b) and 1.1310 wherever such exposures might occur.
Measures must be taken to ensure compliance with limits for both occupational/controlled
exposure and for general population/uncontrolled exposure, as defined in these rule sections.
Compliance can be accomplished in most cases by appropriate restrictions such as fencing.
Requirements for restrictions can be determined by predictions based on calculations, modeling or
by field measurements. The FCC's OET Bulletin 65 (available on-line at www.fcc.gov/oet/rfsafety)
provides information on predicting exposure levels and on methods for ensuring compliance,
including the use of warning and alerting signs and protective equipment for worker.



Document Created: 2019-06-19 16:17:40
Document Modified: 2019-06-19 16:17:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC