Attachment PSSI NT 29 - Rad Haz

This document pretains to SES-LIC-20170127-00093 for License on a Satellite Earth Station filing.

IBFS_SESLIC2017012700093_1169512

Radiation Hazard Report                                                                                       Page 1 of 5


               Analysis of Non-Ionizing Radiation for a 2.4 Meter Earth
                                   Station System

This report analyzes the non-ionizing radiation levels for an Avl Technologies 2400K 2.4 meter Ku band earth
station system.The analysis and calculations performed in this report comply with the methods described in the
FCC Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997 in Edition
97-01. The radiation safety limits used in the analysis are in conformance with the FCC R&O 96-326. Bulletin No.
65 and the FCC R&O specifies that there are two separate tiers of exposure limits that are dependent on the
situation in which the exposure takes place and/or the status of the individuals who are subject to the
exposure.The Maximum Permissible Exposure (MPE) limits for persons in a General Population/Uncontrolled
environment are shown in Table 1. The General Population/Uncontrolled MPE is a function of transmit frequency
and is for an exposure period of thirty minutes or less. The MPE limits for persons in an Occupational/Controlled
environment are shown in Table 2. The Occupational MPE is a function of transmit frequency and is for an
exposure period of six minutes or less. The purpose of the analysis described in this report is to determine the
power flux density levels of the earth station in the far-field, near-field, transition region, between the subreflector
or feed and main reflector surface, at the main reflector surface, and between the antenna edge and the ground
and to compare these levels to the specified MPEs.

      Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
     Frequency Range (MHz)                    Power Density (mW/cm2)
              30-300                                       0.2
             300-1500                         Frequency (MHz)*(0.8/1200)
          1500-100,000                                     1.0



       Table 2. Limits for General Population/Controlled Exposure (MPE)
     Frequency Range (MHz)                    Power Density (mW/cm2)
              30-300                                       1.0
             300-1500                         Frequency (MHz)*(4.0/1200)
          1500-100,000                                     5.0


            Table 3. Formulas and Parameters Used for Determining Power Flux Densities
Parameter                           Symbol              Formula                   Value             Units
Antenna Diameter                         D                                         2.4                m
                                                             2
Antenna Surface Diameter             Asurface           (πD )/4               4.523893421            m2
Feed Flange Diameter                    Dfa                                      7.3025              cm
                                                                 2
Area of Feed Flange                     Afa            (πDfa )/4              41.88254007            cm2
Frequency                                F                                        14.25              GHz
Wavelength                               l               300 / F              0.021052632             m
Transmit Power                           P                                         500                W
Antenna Gain (dbi)                      Ges                                       49.6               dBi
Antenna Gain (factor)                    G              10Ges/10              91201.08394
Pi                                       π                                    3.141592654
Antenna Efficiency                       η                                    0.711030975


Radiation Hazard Report                                                                                      Page 2 of 5


 1. Far Field Distance Calculation
 The distance to the beginning of the far field can be determined from the following equation:                      (1)

 Distance to the Far Field Region                      Rff      =      0.60D2/l
                                                                =      57.0634125                m

 The maximum main beam power density in the far field can be determined from the following equation:                (2)

 Distance to the Far Field Region                      Sff      =      G P / (4πRff2)
                                                                =      134.6559206               W/m2
                                                                =       13.46559                 mW/cm2

 2. Near Field Calculation

 Power flux density is considered to be at a maximum value throughout the entire length of the defined Near Field
 region. The region is contained within a cylindrical volume having the same diameter as the antenna. Past the
 boundary of the Near Field region, the power density from the antenna decreases linearly with respect to
 increasing distance.


 The distance to the end of the Near Field can be determined from the following equation:                           (3)

 Extent of the Near Field                              Rnf      =            D2 / (4 l)
                                                                                68.4             m

The maximum power density in the Near Field can be determined from the following equation:                          (4)

 Near Field Power Density                              Snf      =      16.0ηP/ (πD2)
                                                                =      314.3447068               W/m2
                                                                                                         2
                                                                =       31.43447                 mW/cm

 3. Transition Region Calculation
 The Transition region is located between the Near and Far Field regions. The power density begins to decrease
 linearly with increasing distance in the Transition region. While the power density decreases inversely with
 distance in the Transition region, the power density decreases inversely with the square of the distance in the Far
 Field region. The maximum power density in the Transition region will not exceed that calculated for the Near Field
 region. The power density calculated in Section 2 is the highest power density the antenna can produce in any of
 the regions away from the antenna. The power density at a distance Rt can be determined from the following
 equation:
                                                                                                                   (5)
 Near Field Power Density                                 St      =      Snf Rnf / Rt
                                                                  ≤      31.43447068           mW/cm2


Radiation Hazard Report                                                                                    Page 3 of 5


4. Distance to Safe Region Calculation
Since the power density decreases inversely with the square of the distance in the Far Field region, the distance to
the On-axis Power Density of 5 mW/cm2 can be determined from the following equation:
                                                                                                                 (6)
                           2                                                     0.5
Distance to ANSI 5 mW/cm                          Dsafe      =       Rff ((Sff/5) )
                                                             =       269.3984                meters

5. Region between the Feed Assembly and the Antenna Reflector
Transmissions from the feed assembly are directed toward the antenna reflector surface, and are confined within a
conical shape defined by the type of feed assembly. The most common feed assemblies are waveguide flanges,
horns or subreflectors. The energy between the feed assembly and reflector surface can be calculated by
determining the power density at the feed assembly surface. This can be determined from the following equation:
                                                                                                              (7)
Power Density at the Feed Flange                     Sfa     =      4000 P /Afa
                                                             =      47752.5956            mW/cm2

6. Main Reflector Region
The power density in the main reflector is determined in the same manner as the power density at the feed
assembly. The area is now the area of the reflector aperture and can be determined from the following equation:
                                                                                                               (8)
Power Density at the Reflector Surface          Ssurface       =    4 P /Asurface
                                                               =    442.0970641           W/m2
                                                                      44.2097                 mW/cm2

7. Off-axis Evaluation
For off-axis calculations in the Near Field and in the Transition region, it can be assumed that, if the point of
interest is at least one antenna diameter removed from the center of the main beam, the power density at that
point would be at least a factor of 100 (20dB) less than the value calculated for the equivalent distance in the main
beam. For off-axis calculations in the Far Field, the calculated main-beam power density can be multiplied by the
appropriate relative power density factor obtained from the antenna gain pattern. Since the proposed antenna
meets or exceeds the performance specifications under Part 25.209 of the FCC rules, the off-axis gain for this
antenna is equal to or greater than 10dBi less than the on-axis gain in any direction of 48 degrees or more
removed from the centerline of the main beam.

The distance to the end of the Near Field can be determined from the following equation:                          (9)

Near Field Off-axis Power Density              Snf(off)        =      0.01 Snf
                                                               =      0.3143                  mW/cm2

Far Field Off-axis Power Density               Sff(off)        =      .1 Sff                                     (10)
                                                                      1.3466                           2
                                                               =                              mW/cm


Radiation Hazard Report                                                                                    Page 4 of 5


8. Summary of Calculations

                   Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                                 Calculated Maximum Radiation Power
 Region                                                 Density Level (mW/cm2)                 Hazard Assessment
Far Field (Rff = 57.0634125 m)                          Sff        13.4656                       Potential Hazard
Near Field (Rnf = 68.4 m)                              Snf         31.4345                       Potential Hazard
Transition Region (Rnf < Rt < Rff)                      St         31.4345                       Potential Hazard
Safe Distance Region (Dsafe =
269.398434699314 meters)                                Dsafe          269.3984                   Potential Hazard
Between Feed Assembly and Antenna
Reflector                                               Sfa            47752.5956                 Potential Hazard
Main Reflector Surface                                 Ssurface        44.2097                    Potential Hazard
Far Field Off-axis Region                               Sff(off)       1.3466                     Potential Hazard
Near Field Off-axis Region (Between
Reflector and ground)                                  Snf(off)        0.3143                     Potential Hazard


                     Table 5. Summary of Expected Radiation levels for Controlled Environment
                                              Calculated Maximum Radiation Power
 Region                                              Density Level (mW/cm2)               Hazard Assessment
Far Field (Rff = 57.0634125 m)                       Sff            13.4656                  Potential Hazard
Near Field (Rnf = 68.4 m)                            Snf            31.4345                  Potential Hazard
Transition Region (Rnf < Rt < Rff)                   St             31.4345                  Potential Hazard
Safe Distance Region (Dsafe =
269.398434699314 meters)                            Dsafe           269.3984                 Potential Hazard
Between Feed Assembly and Antenna                    Sfa            47752.5956               Potential Hazard
Main Reflector Surface                             Ssurface         44.2097                  Potential Hazard
Far Field Off-axis Region                               Sff(off)       1.3466                     Potential Hazard
Near Field Off-axis Region (Between
Reflector and ground)                                  Snf(off)        0.3143                     Potential Hazard

It is the applicant's responsibility to ensure that the public and operational personnel are not exposed to harmful
levels of radiation.


Radiation Hazard Report                                                                                       Page 5 of 5


8. Summary of Calculations
Based on this analysis it is concluded that the FCC RF Guidelines have been exceeded in the specific regions of
Tables 4 and 5. The applicant proposes to comply with the Maximum Permissible Exposure (MPE) limits of 1
mW/cm2 for the Uncontrolled areas and the MPE limits of 5 mW/cm2 for the Controlled areas by one or more of
the following methods:

Means of Compliance - Uncontrolled Areas

This antenna will be located on a vehicle rooftop. The distance from the ground to the center of the antenna is
approximately 4 meters. The location will be sufficient to prohibit access to the areas that exceed the MPE limits.
The general public will not have access to areas within ½ diameter removed from the edge of the antenna.

Radiation hazard signs will be posted at any rooftop access location. The signs will be completely visible from the
ground.

The applicant will ensure that no buildings or other obstacles will be in the areas that exceed the MPE levels.

Means of Compliance - Controlled Areas

The earth station’s operational personnel will not have access to the areas that exceed the MPE levels while the
earth station is in operation.

The transmitters will be turned off during antenna maintenance.

Means of Compliance – Safety in General

This antenna system is located on a mobile unit and conditions will vary from operating site to operating site.
Because of this, the licensee will establish procedures for the operational personnel to verify that the antenna is
not pointing in the direction of populated areas, and that access to hazardous areas are restricted while the unit is
in operation.

In addition, the transmit power used in these calculations is greater than that which will typically be utilized by the
earth station. During normal operation, the typical power level would generally not exceed more than 50 to 75
percent of the indicated transmitter power. Maximum transmit power would generally only occur in conditions of
extreme inclement weather.



Document Created: 2017-01-19 12:08:36
Document Modified: 2017-01-19 12:08:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC