Radiation Hazard Report
Analysis of Non—lonizing Radiation for a 8.1 m Earth Station
This analysis provides the calculated non—ionizing radiation levels for a 8.1—meter earth station system.

The methods and calculations performed in this analysis are based on the FCC Office of Engineering
and Technology Bulletin, No.65, October1985 as revised in 1997 in Edition 97—01. The radiation safety
limits used in the analysis are in conformance with the FCC R&O 96—326 (Summarized in Annex 1).
There are separate exposure limits applicable to the General Population/Uncontrolled Environment and
the Occupational/Controlled Environment. The Maximum Permissible Exposure (MPE) limits for
persons in a General Population/Uncontrolled environment for the frequency band of this antenna, is 1
mWi/icm2 for a 30 minute or lower time period as shown in Annex 1 (a). The MPE limit for persons in an
Occupational/Controlled environment for the frequency band of this antenna is 5 mW/cm2 for a 6
minute time or lower period as shown in Annex 1 (b). The purpose of this analysis described is to
determine the power flux density levels of the earth station at the main reflector surface, the near—field,
transition region, far—field, between the sub—reflector or feed and, at the main reflector surface, and
between the antenna edge and the ground and to compare these levels to the specified MPEs.



The parameters of the antenna that is the subject of this analysis are shown in Table 1.
intermediate calculated values and constants are provided in Table 2.

 Table 1. Input Parameters Used for Determining Power Flux Densities
                 Parameter                     Symbol      Formula               Value            Units
Antenna Diameter                                       D           Input           8.1             m
Sub—reflector Diameter                                 Ds;         Input         102.87            cm
Frequency                                               F          Input         14250            MHz
Transmit Power                                          P          Input           750             W
Antenna Gain (dBi)                                    Gaes         Input          59.9             dBi

 Table 2. Calculated Values and Constants
                 Parameter                          Symbol       Formula         Value            Units
Antenna Surface Area                                 Asurtace      t1D*/4         51.53           mA2
Area of Sub—reflector                                  Asr        nD,,/4        8311.27           cmA2
Wavelength                                              A          300/F        0.021053            m
Antenna Gain (factor)                                  G          10%=*"       977237.22           wa
Pi                                                     T         Constant      3.1415927           wa
Antenna Efficiency                                      n       GI(TD)            0.67             na


1. Antenna Main Reflector Surface
The power density in the main reflector is determined from the Power level and the area of the main
reflector aperture. This is determined from the following equation:

               Power Density at the Main Reflector Surface:

                                          Ssurfaca = 4P/Agurtace                        (1 )
                                                              =    58.219   W/im
                                                              =    5.822    mWicm*

2. Near Field Calculation
Power Flux density is considered to be at a maximum value throughout the entire length of the defined
Near Field region. The region is contained within a cylindrical volume having the same diameter as the
antenna. Past the boundary of the Near Field region, the power density from the antenna decreases
linearly with respect to increasing distance. The distance to the end of the Near Field is determined
from the following equation:

                                    Extent of the Near Field:

                                                Ry=D*/ (4A)                              (2)
                                                          =        77912    m

The maximum power density in the Near Field is determined from the following equation:

                                         Near Field Density:

                                      Sa = 16.0 1 P / (n D)                              (3)
                                                          =        3.894    mWicm*

3. Transition Region Calculation
The Transition Region is located between the Near and Far Field regions. The power density begins to
decrease linearly with increasing distance in the Transition region. While the power density decreases
inversely with distance in the Transition region, the power density decreases inversely with the square
of the distance in the Far Field region. The power density calculated in Section 1 is the highest power
density the antenna can produce in any of the regions away from the antenna. The power density at a
distance R, is determined from the following equation:

                           Transition Region Power Density:

                                               S, = Su Rar/ Ri                           (4)
                                                              =    3.894    mWicm*


 4. Far Field Distance Calculation
 The distance to the Far Field Region is calculated using the following equation:

                                Distance to Far Field Region:

                                               Ry =0.6 D/ A                              (5)
                                                          = 1869.885 m

 The maximum main beam power density in the far field is determined from the following equation:

                      On—axis Power Density in the Far Field:

                                          S,= GP / (4 m Ry*)                             (6)
                                                            =     1.668     mW/(;m2


— 5. Region between the Main Reflector and the Ground
 Assuming uniform illumination of the reflector surface, the power density between the antenna and the
 ground is determined from the following equation:

               Power Density between Reflector and Ground:

                                               Sg =P /Asutface                           (7)

                                                            =     1.455        mW/icm*

 6. Power Density at the Sub—reflector
 Transmissions from the feed assembly are directed toward the sub—reflector surface, and are reflected
 back toward the main reflector. The most common feed assemblies are waveguide flanges, horns or
 sub—reflectors. The energy between the sub—reflector and the reflector surfaces is calculated by
 determining the power density at the sub—reflector surface. This is determined from the following
 equation:

                           Power Density at the Subreflector:

                                            S,, = 4000 P / Ag,                           (8)
                                                             =    360.956    mW/cm*


7. Summary of Calculations

 Table 3. Summary of Expected Radiation levels for Uncontrolled Environment
                                                                             Calculated
                                                                             Maximum
                                                                              Radiation        H          a
                           Region                               Symbol         Power               azar
                                                                              Density      Assessment
                                                                                Level
                                                                             (mWicm*)
1. Main Reflector                                                ssurface       5.822
                                                                                 *
                                                                                              Potential
                                                                                               Hazard
 —
         4                            (Rm —       779.12 m)        Sni          3.894         Potential
                                                                                               Hazard
2. Near Field


3. Transition Region (R,; <R,< Rp)                                 S,           3.894         P:;il;tlrgl

        4                                    —=                                               Potential
4. Far Field                          (R e        1869.89 m)       Sr¢          1.668          Hazard

5. Between Main Reflector and Subreflector                         Ss,         360.956        Potential
                                                                                               Hazard
6. Between Main Reflector and Ground                               S            1.455         Potential
                                                                                               Hazard

Table 4. Summary of Expected Radiation levels for Controlled Environment
                                                                             Calculated
                                                                              Maximum
                                                                              Radiation        H          d
                           Region                               Symbol         Power               azar
                                                                               Density      Assessment
                                                                                Level
                                                                              ({mWicm*)
      .                                                          Ssurface       5.822         Potential
                                                                                               Hazara
1. Main Reflector

                                      (R ns =     779.12 m)        Sm           3.894       Satlsht;gsEFCC
2. Near Field
                                                                    S,          3.894       Satisht/ilgsEFCC
3. Transition Region (R,,; <R,< Rp)
                                      (Re=        1869.89 m)        Sn          1.668       Satlshij"e:sEFCC
4. Far Field

5. Between Main Reflector and Subreflector                         Ss,         360.956         Pk?;iralflrgl

6. Between Main Reflector and Ground                                S,          1.455       Sat'sh';gfiEFCC

It is the applicant‘s responsibility to ensure that the public and operational personnel are no exposed to
harmful levels of radiation.


8. Conclusion
Based upon the above analysis, it is concluded that harmful levels of radiation may exist in those
regions noted for the Uncontrolled (Table 3) Environment and the Controlled Environment (Table 4).

The antenna is located at an Intelsat License LLC‘s teleport facility in Napa, Califomia.
The teleport is a gated and fenced facility with secured access in and around the proposed antenna.
The earth station will be marked with the standard radiation hazard warnings, as well as the area in the
vicinity of the earth station to inform those in the general population, who might be working or otherwise
present in or near the direct path of the main beam.


The applicant will ensure that the main beam of the antenna will be pointed at least one diameter away
from any building, or other obstacles in those area that exceed the MPE levels. Since one diameter
removed from the center of the main beam the levels are down by at least 20 dB, or by a factor of 100,
these potential hazards do not exist for either the public, or for earth station personnel.


Finally, the earth station‘s operating personnel will not have access to areas that exceed the MPE
levels, while the earth station is in operation. The transmitter will be turned off during those periods of
maintenance, so that the MPE standard of 5.0 mW/cm* will be complied with for those regions in close
proximity to the main reflector, which could be occupied by operating personnel.


 "The licensee shall take all necessary measures to ensure that the antenna does not create potential
exposure of humans to radiofrequency radiation in excess of the FCC exposure limits defined in 47
CFR 1.1307(b) and 1.1310 wherever such exposures might occur. Measures must be taken to ensure
compliance with limits for both occupational/controlled exposure and for general
population/uncontrolled exposure, as defined in these rule sections. Compliance can be accomplished
in most cases by appropriate restrictions such as fencing. Requirements for restrictions can be
determined by predictions based on calculations, modeling or by field measurements. The FCC‘s OET
Bulletin 65 (available on—line at www.fec.gov/oet/rfsafety) provides information on predicting exposure
levels and on methods for ensuring compliance, including the use of warning and alerting signs and
protective equipment for workers."


                                  ANNEX 1
                                  (MPE Levels)

a) Limits for General Population/Uncontrolled Exposure (MPE)
          Frequency Ranfige (MHz)                     Power Density (mWIcmz,
                   30—300                                   0.2
                  300—1500                       Frequency(MHz)*(4.0/1200)
                1500—100,000                                 1

b) Limits for                                MPE
          F                                        Power Dens     mWi/icm
                  30—300                                      1
                  300—1500                       Frequency(MHz)*(4.0/1200)
                1500—100,000                                 §



Document Created: 2016-11-23 13:15:13