FCC OET-65 RF Exposure Study - Satellite Uplink Facility
WRAL 4.5 meter Digital Ku-band uplink

FCC Maximum Permissible Exposure Levels                   Source                           Units
Public/uncontrolled area exposure limit                   47CFR §1.1310                  1 mW/cm2
Occupational/controlled area exposure limit               47CFR §1.1310                  5 mW/cm2

Input Data
Antenna Diameter                                          datasheet                  450.0 cm
Antenna surface area                                      calculated              159043 cm2
Sub-reflector diameter                                    measured          n/a            cm          Prime focus antenna
Sub-reflector area                                        calculated        n/a            cm2
Feed flange diameter                                      datasheet                19.500 cm2
Feed flange area                                          calculated                   299
Frequency                                                 (entry)                   14500 MHz
Wavelength (speed of light = 299,792,458 m/s)             calculated                 2.068 cm
Transmit power at flange                                  Application               18900 milliwatts
Antenna gain                                              datasheet                   53.9 dBi
Antenna gain factor                                       calculated              245471
Height of base of antenna above ground/roof               datasheet                   1.56 m
Height of center of antenna above ground/roof             datasheet                   3.69 m
Minimum Elevation Angle                                   (entry)                       12 degrees
Minimum Elevation Angle                                   calculated              0.20944 radians
                                                                                                           FCC Maximum Permissible Exposure (MPE)
Results calculated using FCC Bulletin OET-65 (Edition 97-01 August 1997)                                     Uncontrolled            Controlled
Maximum power density at antenna surface               Eq. 11 Pg 27            0.48 mW/cm2                 Below FCC MPE          Below FCC MPE
Power density at subreflector                          Eq. 11 Pg 27   N/A            mW/cm2                      N/A                    N/A
Power density at feed flange                           Eq. 11 Pg 27         253.14 mW/cm2                  Potential Hazard       Potential Hazard
Extent of near-field                                   Eq. 12 Pg 27          24486 cm
Maximum near-field power density                       Eq. 13 Pg 28            0.25 mW/cm2                 Below FCC MPE                Below FCC MPE
Aperture efficiency                                    Eq. 14 Pg 28            0.53
Distance to beginning of far-field                     Eq. 16 Pg 29       58765.65 cm
Power density at end of the transition regiion         Eq. 17 Pg 29              0.1 mW/cm2                Below FCC MPE                Below FCC MPE
Maximum far-field power density                        Eq. 18 Pg 29           0.107 mW/cm2                 Below FCC MPE                Below FCC MPE

Main Beam Far-field region safe exposure distances
Minimum distance for public/uncontrolled exposure         Eq. 18 Pg 29             192.14 meters
   Height at minimum antenna elevation angle              calculated                43.64 meters
   Horizontal distance                                    calculated               187.94 meters

Minimum distance for occupational/controlled exposure     Eq. 18 Pg 29              85.93 meters
   Height at minimum antenna elevation angle              calculated                21.56 meters
   Horizontal distance                                    calculated                84.05 meters

Off-Axis Near Field/Transition Region safe exposure distances from antenna
(20 dB reduction in power density at distances greater
than one antenna diameter from the main beam center.)  OET-65 Pg 30
Maximum off-axis near field power density              Eq. 13 Pg 28                0.0025 mW/cm2           Below FCC MPE                Below FCC MPE
Public/uncontrolled exposure off-axis distance         Diam/or Eq 17                   4.5 meters
Occupatonal/controlled exposure off-axis distance      Diam/or Eq 17                   4.5 meters

Off-Axis Far Field safe exposure distances from the antenna
(Based on side lobe attenuation required by FCC 25.209(a)(2))
Angle off main beam axis (1 to 48 degrees)                (entry)                       5 degree(s)
     Off-axis antenna gain factor                         OET-65 Pg 30*                28
     Minimum distance for public/uncontrolled exposure    Eq. 18 Pg 29 **          587.66 meters
 * Gain converted from dBi to linear multiple
 ** If calculated distance is less than the start of the
   far field region, the distance to the start of the far
   field region is used.

Uplink Remote Control Point Data
WRAL 4.5 meter Digital Ku-band uplink

                                                Location: 30 Rockefeller Plaza
                                                          New York, NY 10112

                                    Telephone Number: (212) 664-1900


                                                                                                         Prepared by Doug Lung, NBC Universal, February 12, 2016