                           Radiofrequency (RF) Radiation Hazard Study
                           License No. New: Triunfo Pass (AT&T Corp.)
This report summarizes the non-ionizing radiofrequency (RF) exposure levels associated with the above antenna
system. RF prediction models and associated exposure limits referenced in this study are outlined in the
Federal Communications Commission (FCC) Office of Engineering and Technology (OET) Bulletin 65
Edition 97-01 (August 1997). The FCC-exposure limits define the level of RF energy that a person may be
continuously exposed without experiencing adverse health effects. This "safe" level, herein referred to
as Maximum Permissible Exposure (MPE) limit, is comprised of two-tiers: one for conditions which the public may
be exposed (General Population/Uncontrolled) and the other for exposure situations usually involving workers
(Occupational/Controlled). Therefore, the intent of this study is to define the maximum "worst-case"
RF exposure levels and compare the results relative to the applicable MPE limits.

Based upon the following system parameters, the applicable MPE limits are:            1.0   mW/cm^2 and
    5.0     mW/cm^2 for General Population/Uncontrolled and Occupational/Controlled environments,
respectively, as specified in 47 CFR Part 1.1310.
                                                  System Parameters
          Antenna Diameter (D1):           9.0      meters          Antenna Surface Area (D1a):      63.62   meters^2
       Subreflector Diameter (D2):         1.2      meters       Subreflector Surface Area (D2a):     1.13   meters^2
            Operating Frequency:         14000      MHz                           Wavelength (l):    0.021   meters
 Antenna Gain (G), @ 14250 MHz:           60.1      dBi                           Numerical Gain: 1023292.99
Transmit Power @ Antenna Input*:         300.0      watts
Calculated Aperture Efficiency (n ):      0.59                  Center height above ground level:        4.5         meters

   * Based on a 400 W maximum power rated amplifier (SSPA), where the actual operating power level will
     be reduced by at least a factor of 1.26 (1.0 dB) minimum signal loss. For purposes of
     study, this equates to an aggregate output EIRP for all carriers of     84.87     dBw maximum.

                                                  Hazard Assessment

For parabolic aperture antennas, three (3) regions are defined for predicting maximum RF exposure levels within
the main-beam (on-axis) path: near-field, transition, and far-field regions. RF prediction methods are based
on where the point-of-interest falls within these regions:

       1. The far field (Rff) region is determined by the following equation: 0.6 D^2/l . This equates to a linear
     distance of approximately            2268.00      meters from the antenna. The maximum main beam RF
     exposure level (Sff), in terms of power density units, at this point can be calculated as follows:

                        Sff = PG / 40p(Rff)^2 =        0.47     mW/cm^2

     2. The near field (Rnf) region is determined by the following equation: D^2/ 4l . This equates to a linear
     distance of approximately           945.00        meters from the antenna. The maximum RF exposure level
     (Snf), in terms of power density units, within this region can be calculated as follows:

                          Snf = 0.4n P/ D1a =  1.11   mW/cm^2
                (Assume maximum value maintained throughout the near field region)


 ** The transition (Rt) region is between the near-field and far-field regions, defined as Rff - Rnf. This equates to a
     region extending   1323.00 meters, beginning at           945.00 meters and ending             2268.00    meters
     from the antenna. While the exposure intensity decreases inversely with the square of the distance in the




   February, 2005                                       Page 1 of 3


                  Radiofrequency (RF) Radiation Hazard Study - Continued
                       License No. New: Triunfo Pass (AT&T Corp.)
                                            Hazard Assessment - Continued



     far field region, the exposure intensity decreases inversely with distance in the transition region. Therefore, the
     maximum RF exposure level in the transition region will not exceed the above calculated near field value (Snf).
     If the point-of-interest falls within the transition region, the estimated RF exposure level (St), in terms of power
     density units, can be calculated using the following mid-point (Rt) example:

                                St = Snf * Rnf / R =     0.65    mW/cm^2 - at mid-point of Rt
                                    note: where 'R' is the point-of-interest within the Rt



This dual-reflector (cassegrain) antenna design uses a shaped subreflector to direct RF energy from the feed horn
back towards the main reflector dish. The following calculations are used to predict the RF exposure levels directly in
front of the main reflector surface (rim), and regions between the main reflector and subreflector surfaces:



    3. The maximum RF exposure level (Smain-surface) in front of the main reflector surface (at rim), in terms of
    power density units, can be calculated as follows:

                               Smain-surface = 0.4*P / D1a =         1.89     mW/cm^2

    4. The maximum RF exposure level at the subreflector surface (Ssub-surface), in terms of power density units,
    can be calculated as follows:

                                 Ssub-surface = 0.4*P / D2a =      106.10     mW/cm^2




For evaluating accessible areas outside the main beam path, a practical estimation is to consider the maximum
allowable gain pattern envelope for fixed-satellite services. Specifically, the antenna gain shall lie below the
envelope defined as -10 dBi for angles greater than 48 degrees and less than/equal to 180 degrees from the main
lobe axis. In considering areas immediately below the main reflector rim, the maximum RF exposure levels
directed towards this region (Spoi), in terms of power density units, can be calculated as follows:

    5.                             Spoi = PG/40p(R)^2 =               0.012 mW/cm^2
                        Note : where 'R' is the point-of-interest is just below antenna rim, which
                         equates (in this case) to a centerline distance:          4.5     meters




   February, 2005                                        Page 2 of 3


                   Radiofrequency (RF) Radiation Hazard Study - Continued
                        License No. New: Triunfo Pass (AT&T Corp.)
                                       Hazard Assessment - Summary
                             Summary of Calculated RF Exposure Levels
         Region                           Level (mW/cm^2)                              Assessment
 A.   Far Field (Rff),   2268.00    meters, =           0.47                      Satisfies FCC MPE Limits
 B.   Near Field (Rnf),   945.00    meters, =           1.11      Potential to exceed FCC Public/Uncontrolled MPE Limit
 C.   Rim of Main Reflector =                           1.89      Potential to exceed FCC Public/Uncontrolled MPE Limit
 D.   Subreflector =                                  106.10         Potential to exceed FCC Occupational MPE Limit
 E.   Area below Antenna Rim =                         0.012                      Satisfies FCC MPE Limits



     C                                              D
 Rim of Main                                    Subreflector                                                 A
  Reflector                                                                                               Far Field

                                                                     B
                                                                  Near Field


Feed Horn




                                                                                                    E
                                                                                         Area Below Antenna Rim


                                                        Conclusion

The results of this study indicate that accessible ground level areas, surrounding the antenna base
and horizontal to the main beam axis, do not exceed the most restrictive FCC-General Population/Uncontrolled
MPE limit.

The highest RF exposure levels are isolated to regions located between the feed horn and subreflector surface,
which are typically inaccessible during normal operations. To ensure compliance with the FCC Occupational/Controlled
MPE limit, these areas shall be controlled (restricted access) and the antenna system de-energized during any
maintenance/service activities occurring within the main reflector or subreflector regions.

This study concludes that operation of this satellite earth station will not expose workers or public members
to RF levels in excess of the applicable MPE limits. Therefore, in accordance with 47 CFR Part 1.1307 (b),
preparation and submission of an Environmental Assessment (EA) is not required.


          Performed by:      Kimberly A. Kantner, RRPT                    AT&T / EH&S - Radiation Safety Office