                                         EXHIBIT 1
                                        (Page 1 of 4)

                        NONIONIZING RADIATION COMPLIANCE
                             NewsChannel 5 Network, LLC

     The applicant will take appropriate steps to insure that the operation of the tempo-

rary fixed transmit/receive earth station facilities proposed in the attached application

fully complies with the FCC’s nonionizing radiation exposure standard at all times it is in

operation. The antenna for this earth station is a 1.25 meter diameter steerable dish

which is permanently affixed to the top of a truck with the center of this dish located at a

height of 3.1 meters above ground level. This earth station will transmit in the 14.0 to

14.5 Ghz band with a maximum power at the antenna flange of 87 watts, which will yield

a maximum total main beam EIRP of 62.8 dBw from this antenna system. Under nor-

mal operating conditions, this antenna will operate at elevation angles ranging from 15°

to 50°. In this frequency range, the maximum permitted power density for uncontrolled

exposure is 1 mW/cm2, while the maximum permitted power density for controlled expo-

sure is 5 mW/cm2.

     The procedures and calculation techniques employed to evaluate the power den-

sity levels in the vicinity of an aperture antenna, such as the proposed earth station an-

tenna, are outlined on Pages 27 through 31 of the August, 1997 edition of FCC OET

Bulletin 65. The analysis of such an antenna is divided into four regions - the antenna

surface, the near field region, the transition region, and the far field region.

     The maximum power density at the antenna surface is calculated using Equation

11, found on Page 28 of this OET Bulletin. Substituting the appropriate values from

above into this equation yields a maximum predicted power density of 28.4 mW/cm2 at

any location on the surface of this antenna. Since this exceeds the permitted power

density for both controlled and uncontrolled exposure, it will be necessary for the appli-

                               Carl E. Smith Consulting Engineers


                                           EXHIBIT 1
                                          (Page 2 of 4)

cant to insure that no persons are in proximity to the surface of this dish while it is in

operation.

     Based on Equation 12, also found on Page 28 of this OET Bulletin, the near field

region for the main beam of this antenna extends to a distance ranging from 18.2 me-

ters to 18.9 meters over the frequency range involved. Using Equation 13 found of

Page 29 of this bulletin and a measured aperture efficiency of 0.65, the maximum power

density which will exist anywhere in the near field region of the main beam of this an-

tenna is predicted to be 18.4 mW/cm2, which still exceeds the maximum permitted level

for both controlled and uncontrolled exposure.

     In the main beam of the antenna, the transition region begins at the end of the

near field region and, from Equation 16 found on Page 30 of this OET Bulletin, extends

to a distance ranging from 43.7 meters to 45.3 meters from the antenna over the range

of frequencies involved. Using Equation 17, also found on page 30 of this bulletin, it

was determined that the predicted main beam power densities in the transition region

will range from the near field maximum of 18.4 mW/cm2 at the portion of this region

closest to the antenna to a minimum of 7.8 mW/cm2 at the far end of this transition re-

gion. Based on this data, the predicted main beam power density for this facility will

also exceed the permitted values for both controlled and uncontrolled exposure over the

entire length of the transition region.

     As outlined on Page 31 of this OET Bulletin, however, “...in the near field and tran-

sition regions it can be assumed that, if the point of interest is at least one antenna di-

ameter removed from the center of the main beam, the power density at that point

would be at least a factor of 100 (20 dB) less than the value calculated for the equiva-


                               Carl E. Smith Consulting Engineers


                                         EXHIBIT 1
                                        (Page 3 of 4)

lent distance in the main beam.” Based on this information, the power density calcula-

tions outlined above for the near field and transition regions represent the maximum

power density predicted to occur within a cylinder centered around the main beam of

the antenna and extending from the antenna to the end of the transition region. At all

locations outside this cylinder, the maximum predicted power density will not exceed

0.184 mW/cm2 (1/100th of the maximum predicted power density within this cylinder),

which is well below the permitted exposure level for both controlled and uncontrolled

exposure. Thus, so long as the applicant restricts access to the top portion of this

truck, where the antenna is mounted, and also to all areas in the vicinity of this uplink

truck where any portion of this cylinder lies within two meters of ground level, it will not

be possible for any person in the vicinity of this uplink truck to be exposed to power den-

sities exceeding the permitted level for either controlled or uncontrolled exposure.

Based on the lowest elevation angle of 15° which will be employed during normal opera-

tion, and the fact that the top of the truck is 2.4 meters high, the operator only needs to

restrict access to the roof of the vehicle during times when the transmitter is in opera-

tion, to insure compliance in the immediate vicinity of this vehicle.

     Since the predicted main beam power density at the end of the transition region is

still in excess of the permitted level for both controlled and uncontrolled exposure, it was

necessary to conduct further calculations utilizing Equation 18, found on Page 30 of this

OET Bulletin to evaluate the maximum distance in the main lobe of this antenna in the

far field region at which power densities exceeding those permitted for uncontrolled ex-

posure would occur. These calculations determined that the predicted power density in

the main beam of this antenna will exceed the permitted level for uncontrolled exposure


                               Carl E. Smith Consulting Engineers


                                         EXHIBIT 1
                                        (Page 4 of 4)

out to a distance of 123.1 meters (404 feet) from this antenna. Thus, in order to insure

compliance with this exposure standard at distant locations within the main beam of this

antenna, it will also be necessary for the applicant to insure that there are no buildings

or other occupied structures located in the main beam of this antenna out to a distance

of 123.1 meters from this antenna.

     The applicant will take the necessary steps to restrict access to the areas outlined

above at which excessive power density levels are predicted to occur. By doing so, the

applicant will insure that this uplink facility will fully comply with the FCC’s nonionizing

radiation exposure standard when this uplink facility is in operation.




                               Carl E. Smith Consulting Engineers