Attachment RF Hazard Exhibit

This document pretains to SES-LIC-20130603-00465 for License on a Satellite Earth Station filing.

IBFS_SESLIC2013060300465_998322

Radiation Hazard Report                                                            Page 1 of 5


      Analysis of Non-Ionizing Radiation for a 1.8-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for an AVL Technologies 1.8-meter earth
station system. The analysis and calculations performed in this report comply with the methods
described in the FCC Office of Engineering and Technology Bulletin, No. 65 first published in 1985
and revised in 1997 in Edition 97-01. The radiation safety limits used in the analysis are in
conformance with the FCC R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are
two separate tiers of exposure limits that are dependant on the situation in which the exposure
takes place and/or the status of the individuals who are subject to the exposure. The Maximum
Permissible Exposure (MPE) limits for persons in a General Population/Uncontrolled environment
are shown in Table 1. The General Population/Uncontrolled MPE is a function of transmit
frequency and is for an exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol            Formula                Value          Units
     Antenna Diameter                D                                       1.8          m
     Antenna Surface Area          Asurface           D2 / 4              2.544          m2
     Feed Flange Diameter           Dfa                                     7.62          cm
     Area of Feed Flange            Afa               Dfa 2/4              45.6          cm2
     Frequency                       F                                     14.25          GHz
     Wavelength                                     300 / F               0.0211         m
     Transmit Power                  P                                       150          W
     Antenna Gain (dBi)             Ges                                      45           dBi
     Antenna Gain (factor)           G               10Ges/10              31622
     Pi                                                                 3.1415927
     Antenna Efficiency                                                     0.6


Radiation Hazard Report                                                               Page 2 of 5
1. Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 /                        (1)
                                                                = 92.34 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4  Rff 2)                 (2)
                                                                = 44.26 W/m2
                                                                = 4.42mW/cm2

2. Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 )                        (3)
                                                                = 38.47 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0  P / ( D2)                 (4)
                                                                = 141.4 W/m2
                                                                = 14.14 mW/cm2

3. Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 2 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                       (5)
                                                               ≤ 14.14 mW/cm2


Radiation Hazard Report                                                                  Page 3 of 5
4. Distance to Safe Region Calculation

Since the power density decreases inversely with the square of the distance in the Far Field
region, the distance to the On-axis Power Density of 5 mW/cm2 can be determined from the
following equation:

   Distance to ANSI 5 mW/cm2                               Dsafe = Rff ((Sff / 5) 0.5)                 (6)
                                                                 = 86.88 meters

5. Region between the Feed Assembly and the Antenna Reflector

Transmissions from the feed assembly are directed toward the antenna reflector surface, and are
confined within a conical shape defined by the type of feed assembly. The most common feed
assemblies are waveguide flanges, horns or subreflectors. The energy between the feed assembly
and reflector surface can be calculated by determining the power density at the feed assembly
surface. This can be determined from the following equation:

   Power Density at the Feed Flange                           Sfa = 4000 P / Afa                       (7)
                                                                  = 13156 mW/cm2

6. Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the feed assembly. The area is now the area of the reflector aperture and can be determined from
the following equation:

   Power Density at the Reflector Surface               Ssurface = 4 P / Asurface                      (8)
                                                                 = 235 W/m2
                                                                 = 23.57 mW/cm2

7. Off-axis Evaluation

For off-axis calculations in the Near Field and in the Transition region, it can be assumed that, if
the point of interest is at least one antenna diameter removed from the center of the main beam,
the power density at that point would be at least a factor of 100 (20dB) less than the value
calculated for the equivalent distance in the main beam. For off-axis calculations in the Far Field,
the calculated main-beam power density can be multiplied by the appropriate relative power
density factor obtained from the antenna gain pattern. Since the proposed antenna meets or
exceeds the performance specifications under Part 25.209 of the FCC rules, the off-axis gain for
this antenna is equal to or greater than 10dBi less than the on-axis gain in any direction of 48
degrees or more removed from the centerline of the main beam.

   Near Field Off-axis Power Density                    Snf(off) = 0.01 Snf                            (9)
                                                                 = .141 mW/cm2

   Far Field Off-axis Power Density                     Sff(off)   = 0.1 Sff                           (10)
                                                                   = .4427 mW/cm2


Radiation Hazard Report                                                      Page 4 of 5
8. Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                        Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
Far Field (Rff = 93.34 m)                       Sff          4.42             Potential Hazard
Near Field (Rnf = 38.47 m)                      Snf        14.14              Potential Hazard
Transition Region (Rnf < Rt < Rff)              St         14.14              Potential Hazard
Safe Distance Region (Dsafe=86.88 m)
Between Feed Assembly and Antenna               Sfa        13156             Potential Hazard
   Reflector
Main Reflector Surface                          Ssurface   23.57             Potential Hazard
Far Field Off-axis Region                       Sff(off)   .1415           Meets Ansi Standards
Near Field Off-axis Region                      Snf(off)   .4427           Meets Ansi Standards
(Between reflector and ground)


            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                             (mW/cm2)                Hazard Assessment
Far Field (Rff = 93.34 m)                      Sff          4.42            Meets Ansi Standards
Near Field (Rnf = 38.47 m)                     Snf         14.14              Potential Hazard
Transition Region (Rnf < Rt < Rff)             St          14.14              Potential Hazard
Safe Distance Region (Dsafe=86.88 m)
Between Feed Assembly and Antenna               Sfa        13156             Potential Hazard
   Reflector
Main Reflector Surface                          Ssurface   23.57             Potential Hazard
Far Field Off-axis Region                       Sff(off)   .1414           Meets Ansi Standards
Near Field Off-axis Region                      Snf(off)   .4427           Meets Ansi Standards
(Between reflector and ground)

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.


Radiation Hazard Report                                                            Page 5 of 5
9. Conclusions

Based on this analysis it is concluded that the FCC RF Guidelines have been exceeded in the
specific regions of Tables 4 and 5. The applicant proposes to comply with the Maximum
Permissible Exposure (MPE) limits of 1 mW/cm2 for the Uncontrolled areas and the MPE limits of
5 mW/cm2 for the Controlled areas by one or more of the following methods:


Means of Compliance - Uncontrolled Areas

This antenna will be located on a vehicle rooftop. The distance from the ground to the center of
the antenna is approximately 3 meters. The location will be sufficient to prohibit access to the
areas that exceed the MPE limits. The general public will not have access to areas within ½
diameter removed from the edge of the antenna.

Radiation hazard signs will be posted at any rooftop access location. The signs will be completely
visible from the ground.

The applicant will ensure that no buildings or other obstacles will be in the areas that exceed the
MPE levels.


Means of Compliance - Controlled Areas


The earth station’s operational personnel will not have access to the areas that exceed the MPE
levels while the earth station is in operation.

The transmitters will be turned off during antenna maintenance.


Means of Compliance – Safety in General

This antenna system is located on a mobile unit and conditions will vary from operating site to
operating site. Because of this, the licensee will establish procedures for the operational
personnel to verify that the antenna is not pointing in the direction of populated areas, and that
access to hazardous areas are restricted while the unit is in operation.

In addition, the transmit power used in these calculations is greater than that which will typically be
utilized by the earth station. During normal operation, the typical power level would generally not
exceed more than 50 to 75 percent of the indicated transmitter power. Maximum transmit power
would generally only occur in conditions of extreme inclement weather.