Attachment Exhibit_2_--_RadHaz

This document pretains to SES-LIC-20120315-00265 for License on a Satellite Earth Station filing.

IBFS_SESLIC2012031500265_942778

                                                               Radiation Hazard Analysis



                                                                             13 Meter
                                                                     Mount Airy, Maryland 21771

                     Introduction
                     A radiation hazard anaylsis is presented for a 13 meter C band aperture antenna to be installed in Mount
                     AiryMaryland at the SES WORLD SKIES Woodbine. This Radiation Analysis calculates the non-ionizing radiation
                     levels expected to be emitted from the earth station on a worse cases basis and is performed in accordance with the
                     Federal Communications Commissions Office of Engineering and Technology (OET) Bulletin, No. 65.



                     Requirements
                     OET 65 outlines the maximum permissible exposure limits in two cases for operation in this frequency range.

                         1. The first case is the maximum level that a person may be exposed to in the general population. The exposure
                              limit is defined as a non-ionizing power level equal to 1 milliwatt per centimeter squared averaged over a thirty
                              minute period.
                         2. The second case is a controlled environment where the maximum permissible exposure limit must not exceed 5
                              milliwatts per centimeter squared averaged over any six minute period.

                     Summary
                     The results indicate that no significant hazard will be presented to the general population and will be fully mitigated in
                     the controlled area by the use of procedures that require the removal of transmit power before accessing the area
                     around the main reflector.


                     Analysis
                     This analysis was performed on seven zones with the results shown in Radiation Hazard Zones. The Table labeled
                     Input Values provides the - input data required to perform the analysis. The table labeled OET 65 Calculated Values
                     provides the intermediate calculation used to perform the assessment in accordance with OET 65. The Analysis is
                     performed for each a the each of seven radiation zones as shown in figure 1 – Analysis Zones. These zones are:


                         1. Point between the feed and the sub-reflector
                         2. The power at the surface of the antenna
                         3. The power level between the main reflector and ground
                         4. The near-field or Fresnel region in which the maxima can be reached before the field starts to diminish with
                            distance
                         5. The Transition region where power begins to decrease inversely with distance from the antenna
                         6. The Far Field or Fraunhofer region where power decreases inversely with the square of the distance. This is the
                            point at which the antenna beam is fully collimated
                         7. The off axis level in the near field. This is defined as the area outside of the main beam removed and at least one
                            antenna diameter removed from the main beam




Generated 2/8/2011                                                              1 of 2                                                 rad haz auto report-wdb-ses2


                                                         Radiation Hazard Analysis

                                       Operator:              SES WORLD SKIES
                            Location Designation:             Woodbine                        FCC Callsign:
                                         County:              Prince William                       SES ID:
                                           Town:              Mount Airy                              STA:
                                       State/Zip:             Maryland       21771
                          Input Values                            Value          Unit                              Band          Frequency
                              D = Aperture Diameter               13.00            Meters                           L            1000-2000
                           d = Subreflector Diameter                0.7            Meters                           S            2000-4000
                                  G = Antenna Gain                 57.1                dBi                          C            4000-8000
                                   FCC Designation                   C             Band                             X           8000-12500
                                      F = Frequency               6.000            GHz                              Ku          12500-18000
                        P = Transmitter Power Watts:              2161             Watts                            K           18000-25500
                  R ua = closest point to uncontrolled area         20            meters                            Ka          26500-40000
                  Elevation angle at closest point R ua             11            Degrees                           O           40000-50000
                                        Height (AGL)               3.82           meters                            V           50000-75000

                  OET 65 Calculated Values                      Formula            Value          Unit
                                                                    c
                                       λ= Wavelength                              0.0500     meters
                                                                    F
                                                                    (G/10)
                                   G = Antenna Gain              10             512861.384   (W) linear
                                                                 Gλ2/4π
                          η = Apperture Efficiency                                     77%   percentage
                                                                  πD2/4
                               A = Area of reflector               πR2            132.732    meters 2
                            a = area of subreflector                πr2          3848.451    cm 2
                                                                    D2            845.564    meters
                          R nf = Near-Field Region
                                                                    4λ              161      Meters AGL
                                                                   >Rnf          845.564     >meters
                            R t = Transition Region
                                                                   <Rff          2029.353    <meters
                             R ff = Far Field Region              0.6D2          2029.353    meters
                                                                     λ              387      Meters AGL

                                                                                                                      Exposure Limits
              Radiation Analysis Zone                           Formula            Level          Value       General Public   Occupational
                                                                                                               <1mW/cm2     <5mW/cm2
                                                                    4P                                        >FCC MPE See >FCC MPE See
         1                       Power Subreflector                              2246.098        mW/cm2
                                                                     a                                           Note 1       Note 2
                                                                    4P                                        >FCC MPE See >FCC MPE See
         2                          Antenna Surface                                6.512         mW/cm2
                                                                     A                                           Note 1       Note 2
                                                                     P                                        >FCC MPE See
         3                  Main Reflector Ground                                  1.628         mW/cm2                     <FCC MPE
                                                                     A                                           Note 1
                                                                   4η P                                       >FCC MPE See
         4        S nf =Near-Field Power Density                                   4.999         mW/cm2                     <FCC MPE
                                                                     A                                           Note 1
                                                                                                              >FCC MPE See
         5    S t = Max Transition Power Density                   < Snf           4.999         mW/cm2                     <FCC MPE
                                                                                                                 Note 1
                                                                    PG                                        >FCC MPE See
         6     S ff = Max Far field Power Density                                  2.142         mW/cm2                          <FCC MPE
                                                                  4πRff2                                         Note 3
         7       Off Access Level Near Field                    Snf - 20 dB       0.04999        mW/cm2         <FCC MPE         <FCC MPE

       Notes
         1. The antenna is installed in a controlled location access is restricted to authorized personnel only. The antenna is
            marked with RF Radiation Hazard signage.
         2. Inside the controlled area, MPE levels exceed the MPE exposure for occupational levels. The levels will be
            reduced to safe MPE by removing power to the transmitters when work is performed on or around the antenna.
            This area can only be accessed by qualified personnel.
          3. The field develops 3.82 meters above ground level at the minimum elevation angle which is not accessable to
             the general public.




Generated 2/8/2011                                                            2 of 2                                     rad haz auto report-wdb-ses2